• Title/Summary/Keyword: 3D imaging system

Search Result 498, Processing Time 0.032 seconds

The Vectra M3 3-dimensional digital stereophotogrammetry system: A reliable technique for detecting chin asymmetry

  • Hansson, Stina;Ostlund, Emil;Bazargani, Farhan
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.43-51
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the reliability of the Vectra M3 (3D Imaging System; Canfield Scientific, Parsippany, NJ, USA) in detecting chin asymmetry, and to assess whether the automatic markerless tracking function is reliable compared to manually plotting landmarks. Materials and Methods: Twenty subjects (18 females and 2 males) with a mean age of 42.5±10.5 years were included. Three-dimensional image acquisition was carried out on all subjects with simulated chin deviation in 4 stages (1-4 mm). The images were analyzed by 2 independent observers through manually plotting landmarks and by Vectra software auto-tracking mode. Repeated-measures analysis of variance and the Tukey post-hoc test were performed to evaluate the differences in mean measurements between the 2 operators and the software for measuring chin deviation in 4 stages. The intraclass correlation coefficient (ICC) was calculated to estimate the intra- and inter-examiner reliability. Results: No significant difference was found between the accuracy of manually plotting landmarks between observers 1 and 2 and the auto-tracking mode (P=0.783 and P=0.999, respectively). The mean difference in detecting the degree of deviation according to the stage was <0.5 mm for all landmarks. Conclusion: The auto-tracking mode could be considered as reliable as manually plotted landmarks in detecting small chin deviations with the Vectra® M3. The effect on the soft tissue when constructing a known dental movement yielded a small overestimation of the soft tissue movement compared to the dental movement (mean value<0.5 mm), which can be considered clinically non-significant.

Nonuniformity Correction Scheme Based on 3-dimensional Visualization of MRI Images (MRI 영상의 3차원 가시화를 통한 영상 불균일성 보정 기법)

  • Kim, Hyoung-Jin;Seo, Kwang-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.948-958
    • /
    • 2010
  • Human body signals collected by the MRI system are very weak, such that they may be easily affected by either external noise or system instability while being imaged. Therefore, this paper analyzes the nonuniformity caused by a design of the RF receiving coil in a low-magnetic-field MRI system, and proposes an efficient method to improve the image uniformity. In this paper, a method for acquiring 3D bias volume data by using phantom data among various methods for correcting such nonuniformity in MRI image is proposed, such that it is possible to correct various-sized images. It is shown by simulations that images obtained by various imaging methods can be effectively corrected using single bias data.

Photocatalytic Hydrogen Production in Water-Methanol Mixture over Iron-doped CaTiO3

  • Jang, J. S.;Borse, P. H.;Lee, J. S.;Lim, K. T.;Jung, O. S.;Jeong, E. D.;Bae, J. S.;Kim, H. G.
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.95-99
    • /
    • 2011
  • $CaTi_{1-x}Fe_xO_3(0{\leq}x{\leq}0.4)$ solid solution photocatalysts were synthesized by iron doping during the conventional solid state reaction at $1100^{\circ}C$ for 5 h and characterized by ultraviolet-visible (UV-vis) absorption spectroscopy, X-ray diffraction, morphological analysis. We found that $CaTi_{1-x}Fe_xO_3$ samples not only absorb UV but also the visible light photons. This is because the Fe substitution at Ti-site in $CaTi_{1-x}Fe_xO_3$ lattice induces the band transition from Fe3d to the Fe3d + Ti3d hybrid orbital. The photocatalytic activity of Fe doped $CaTiO_3$ samples for hydrogen production under UV light irradiation decreased with the increase in the Fe concentration. There exists an optimized concentration of iron in $CaTiO_3$, which yields a maximum photocatalytic activity under visible light ($\lambda\geq420nm$) photons.

A Mechanism Study of a HyperSpectral Image Sensor for Nadir and Slant Range Operation (직하방과 빗각 촬영 운용을 위한 초분광 영상센서 구동방식에 관한 연구)

  • Lee, Kyeongyeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.484-491
    • /
    • 2019
  • General Hyperspectral Image Sensor acquires an image of line form such as a thin rectangle shape because of using 1D array Push Broom or Whisk Broom scanning method. A special mechanism is required for a Hyperspectral Image Sensor to operate for nadir and slant range. To design the mechanism, the characteristics of the flight motion and the overlap rate between consecutive frames were analyzed. Also, system requirements were proposed through modeling and simulation.

The correlation of the skin color to the blood circulation on the face of Korean female between the ages of 30 and 45 (30${\sim}$40대 한국 여성의 안색과 혈행의 상관성 연구)

  • Kim, Eun-Joo;Roh, Ho-Sik;Kim, Su-Jong;Moon, Eun-Jeong;Kim, Duck-Hee;Kim, Han-Kon;Cho, Ga-Young
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.14 no.2
    • /
    • pp.73-79
    • /
    • 2008
  • Objectives : We investigated the correlation of the skin color to blood circulation on the face of Korean female by noninvasive-skin measuring devices. Methods : Korean female(37.47${\pm}$3.66 years, n=36) aged 30-45 years were participated in this study. We measured the skin color of the face with Spectrophotometer CM2600d (Minolta, Japan) and the skin blood flow with Laser Doppler Imaging-Periscan PIM II (Perimed AB, Sweden). The skin color and blood circulation of three groups (30-35 years, 36-40 years, 41-45 years) divided on age were analyzed by paired-t test and regression analysis. Results : The L* values of the skin were decreased and the a* values were increased significantly with age. This means that the more age increase, the more the skin is dark and red. But the skin blood flow was not significantly different with age and skin color. Conclusions : In the oriental medicine, It was reported that the face of the female over 35 years is changed gradually haggard and the blood circulation is decreased. In our study, the blood circulation was not changed and the skin color was dark and red with increasing the age. We think this symptom resulted from the better nutrition than the past, the change of the blood-quality and this changes were too sensitive to be measured by Laser Doppler Imaging system.

  • PDF

카바졸 전자 공여기를 포함한 D-${\pi}$-A 유도체의 결정 구조

  • Kim, Byung-Soon;Kim, Su-Ho;Matsumoto, Shinya;Son, Young-A
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.63-63
    • /
    • 2011
  • The donor-${\pi}$-acceptor (D-${\pi}$-A) chromophoric dye system has received great attention in variety fields such as electroluminescent materials, sensors and optoelectronic devices. There are many research activities focused on the development for abovementioned application materials with the high-performance properties. In the previous work, we are reported that novel D-${\pi}$-A dye, 2-[4-(9H-carbazol-9-yl)benzylidene]-2,3-dihydroinden-1-one, is successfully attained and exhibited a positive fluorescence solvatochromism. In this work, the molecular structure and packing geometry of 2-[4-(9H-carbazol-9-yl)benzylidene]-2,3-dihydroinden-1-one was discussed by their conformational structure. Their single yellow prism crystal having approximate dimensions of $0.30{\times}0.10{\times}0.10$ mm was carried out with a Rigaku RAXIS RAPID imaging plate area detector with graphite monochromated $CuK_{\alpha}$ radiation. Their crystal structure were solved by using the CrystalStructure crystallographic software package.

  • PDF

Fabrication of a PMN-PZT needle hydrophone for photoacoustic imaging (광음향 영상화를 위한 PMN-PZT 바늘형 수중청음기 제작)

  • Fan, Xiaofeng;Cao, Yonggang;Ha, Kanglyeol;Kim, Moojoon;Kang, Hyun Wook;Oh, Junghwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.175-182
    • /
    • 2016
  • For application to several MHz photoacoustic imaging systems, a needle hydrophone was designed and fabricated by using PMN-PZT piezoelectric single crystal, and its characteristics were evaluated through comparison with a commercial PVDF(Polybinylidene Fluoride) hydrophone of which receiving sensitivity is known. The simulation using the KLM model results show that the peak receiving impulse response for $50{\Omega}$ terminating impedance of the fabricated hydrophone is -261.6 dB re $1V/{\mu}Pa$ and the frequency response is relatively flat over 2 ~ 12 MHz with fluctuation less than 5 dB. The measurement results using tone burst signals also show that it has higher (ave. 10.9 dB) sensitivity than the commercial hydrophone in 2 ~ 8 MHz, and the receiving sensitivity of $-255.8{\pm}2.8$ dB re $1V/{\mu}Pa$ was measured for the fabricated hydrophone. In addition, it is known that the photoacoustic signals and the image of a hair obtained by a mechanical scanned photoacoustic imaging system with the fabricated hydrophone were bigger and better than those obtained with the commercial hydrophone.

Web based 3-D Medical Image Visualization System on the PC (웹 기반 3차원 의료모델 시각화 시스템)

  • Kim, Nam-Kug;Lee, Dong-Hyuk;Kim, Jong-Hyo;Kang, Heung-Sik;Min, Byung-Goo;Kim, Young-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.201-205
    • /
    • 1997
  • With the recent advance of Web and its associated technologies, information sharing on distribute computing environments has gained a great amount of attention from many researchers in many application areas, such as medicine, engineering, and business. One basic requirement of distributed medical consultation systems is that geographically dispersed, disparate participants are allowed to exchange information readily with each other. Such software also needs to be supported on a broad range of computer platforms to increase the software's accessibility. In this paper, the development of world-wide-web based medical consultation system or radiology imaging is addressed to provide the platform independence and great accessibility. The system supports sharing of 3-dimensional objects. We use VRML (Virtual Reality Modeling Language), which is the de-facto standard in 3-D modeling on the Web. 3-D objects are reconstructed from CT or MRI volume data using a VRML format, which can be viewed and manipulated easily in Web-browsers with a VRML plug-in. A Marching cubes method is used in the transformation of scanned volume data set to polygonal surfaces of VRML. A decimation algorithm is adopted to reduce the number of meshes in the resulting VRML file. 3-D volume data are often very large-sized, and hence loading the data on PC level computers requires a significant reduction of the size of the data, while minimizing the loss of the original shape information. This is also important to decrease network delays. A prototype system has been implemented (http://netopia.snu.ac.kr/-cyber/). and several sessions of experiments are carried out.

  • PDF

Construction of Branching Surface from 2-D Contours

  • Jha, Kailash
    • International Journal of CAD/CAM
    • /
    • v.8 no.1
    • /
    • pp.21-28
    • /
    • 2009
  • In the present work, an attempt has been made to construct branching surface from 2-D contours, which are given at different layers and may have branches. If a layer having more than one contour and corresponds to contour at adjacent layers, then it is termed as branching problem and approximated by adding additional points in between the layers. Firstly, the branching problem is converted to single contour case in which there is no branching at any layer and the final branching surface is obtained by skinning. Contours are constructed from the given input points at different layers by energy-based B-Spline approximation. 3-D curves are constructed after adding additional points into the contour points for all the layers having branching problem by using energy-based B-Spline formulation. Final 3-D surface is obtained by skinning 3-D curves and 2-D contours. There are three types of branching problems: (a) One-to-one, (b) One-to-many and (c) Many-to-many. Oneto-one problem has been done by plethora of researchers based on minimizations of twist and curvature and different tiling techniques. One-to-many problem is the one in which at least one plane must have more than one contour and have correspondence with the contour at adjacent layers. Many-to-many problem is stated as m contours at i-th layer and n contours at (i+1)th layer. This problem can be solved by combining one-to-many branching methodology. Branching problem is very important in CAD, medical imaging and geographical information system(GIS).

Realization of Fairy Tale - Robot Aquarium Display System with Visitor Interaction (관람객과 상호 교감하는 전래동화-로봇의 수중무대 연출시스템 구현)

  • Shin, Kyoo-Jae
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1180-1187
    • /
    • 2018
  • This paper had implemented the underwater stage through interaction with fish robots and visitors in the background of traditional fairy tales using 3D floating hologram in an aquarium. The recognition of the object position of the spectator and the underwater robot were performed using the color recognition algorithm. Also, the position tracking algorithm was proposed to follow the object of the visitor and the original fairy tale. This experimental system consists of fish robot, camera, KIOSK for underwater robot control and beam project for underwater imaging. This experiment was carried out by the National Busan Science Museum, and it had satisfied the performance of the underwater stage.