• Title/Summary/Keyword: 3D image reconstruction

Search Result 591, Processing Time 0.033 seconds

Reconstruction of parametrized model using only three vanishing points from a single image (한 영상으로부터 3개의 소실 점들만을 사용한 매개 변수의 재구성)

  • 최종수;윤용인
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3C
    • /
    • pp.419-425
    • /
    • 2004
  • This paper presents a new method which is calculated to use only three vanishing points in order to compute the dimensions of object and its pose from a single image of perspective projection taken by a camera. Our approach is to only compute three vanishing points without informations such as the focal length and rotation matrix from images in the case of perspective projection. We assume that the object can be modeled as a linear function of a dimension vector v. The input of reconstruction is a set of correspondences between features in the model and features in the image. To minimize each the dimensions of the parameterized models, this reconstruction of optimization can be solved by standard nonlinear optimization techniques with a multi-start method which generates multiple starting points for the optimizer by sampling the parameter space uniformly.

Dosimetric Effects of Low Dose 4D CT Using a Commercial Iterative Reconstruction on Dose Calculation in Radiation Treatment Planning: A Phantom Study

  • Kim, Hee Jung;Park, Sung Yong;Park, Young Hee;Chang, Ah Ram
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.27-32
    • /
    • 2017
  • We investigated the effect of a commercial iterative reconstruction technique (iDose, Philips) on the image quality and the dose calculation for the treatment plan. Using the electron density phantom, the 3D CT images with five different protocols (50, 100, 200, 350 and 400 mAs) were obtained. Additionally, the acquired data was reconstructed using the iDose with level 5. A lung phantom was used to acquire the 4D CT with the default protocol as a reference and the low dose (one third of the default protocol) 4D CT using the iDose for the spine and lung plans. When applying the iDose at the same mAs, the mean HU value was changed up to 85 HU. Although the 1 SD was increased with reducing the CT dose, it was decreased up to 4 HU due to the use of iDose. When using the low dose 4D CT with iDose, the dose change relative to the reference was less than 0.5% for the target and OARs in the spine plan. It was also less than 1.1% in the lung plan. Therefore, our results suggests that this dose reduction technique is applicable to the 4D CT image acquisition for the radiation treatment planning.

Display System of Ultra-view Image using Hybrid Image Pickup System (하이브리드 영상획득 장치를 이용한 초다시점 영상 디스플레이 시스템)

  • Choi, Hyun-Jun;Jang, Seok-Woo;Lee, Suk-Yun;Kim, Jae-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.6
    • /
    • pp.1285-1290
    • /
    • 2012
  • People have been interested in the next generation media and service over 3D by development of 3D industry and generalization of 3D-related content and equipment in recent year. Many researchers predict that a strong candidate is digital hologram. Holographic technology is classified to capture(or generation), processing, and display(or reconstruction). This paper discusses the digital holographic display system using hybrid image pickup system and proposes a new structure of digital holographic display system. Through the proposed method a digital hologram can be scalably serviced according to display equipments with various resolutions, computing power of decoding part, and network bandwidth.

Three Dimensional Target Volume Reconstruction from Multiple Projection Images (다중투사영상을 이용한 표적체적의 3차원 재구성)

  • 정광호;진호상;이형구;최보영;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.167-174
    • /
    • 2003
  • In the radiation treatment planning (RTP) process, especially for stereotactic radiosurgery (SRS), knowing the exact volume and shape and the precise position of a lesion is very important. Sometimes X-ray projection images, such as angiograms, become the best choice for lesion identification. However, while the exact target position can be acquired by bi-projection images, 3D target reconstruction from bi-projection images is considered to be impossible. The aim of this study was to reconstruct the 3D target volume from multiple projection images. It was assumed that we knew the exact target position in advance, and all processes were performed in Target Coordinates, where the origin was the center of the target. We used six projections: two projections were used to make a Reconstruction Box and four projections were for image acquisition. The Reconstruction Box was made up of voxels of 3D matrices. Projection images were transformed into 3D in this virtual box using a geometric back-projection method. The resolution and the accuracy of the reconstructed target volume were dependent on the target size. An algorithm was applied to an ellipsoid model and a horseshoe-shaped model. Projection images were created geometrically using C program language, and reconstruction was also performed using C program language and Matlab ver. 6(The Mathwork Inc., USA). For the ellipsoid model, the reconstructed volume was slightly overestimated, but the target shape and position proved to be correct. For the horseshoe-shaped model, reconstructed volume was somewhat different from the original target model, but there was a considerable improvement in determining the target volume.

  • PDF

Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull (전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교)

  • Kang Bok-Hee;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • Purpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/sup TM/. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.

  • PDF

Image Interpolation Using Iterative Error Elimination (반복적 오차 제거를 이용한 영상 보간법)

  • Kim, Won-Hee;Piao, Fengji;Kim, Jong-Nam;Moon, Kwang-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.8
    • /
    • pp.1000-1009
    • /
    • 2011
  • Image interpolation is a technique which estimates the non-allocated pixel values on image scale-transform. It requires minimum computational complexity and minimum image quality degradation on the interpolated resultant images. In this paper we propose an image interpolation method using iterative error estimation. The proposed method consists of the following five steps: loss-information computational step, loss-information estimation step, loss-information application step, error computation step, and error application step. The experimental results obtained show that the average PSNR is increased by 3.3dB, subjective image quality is enhanced and the minimum computation complexity is decreased by 83%. The proposed image interpolation algorithm may be helpful in various applications such as image reconstruction and enlargement.

Web-based Real-time 3D Video Communication System for Reality Teleconferencing

  • Ko, Jung-Hwan;Kim, Dong-Kyu;Hwang, Dong-Chun;Kim, Eun-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1611-1614
    • /
    • 2005
  • In this paper, a new multi-view 3D video communication system for real-time Reality teleconferencing application is proposed by usin gthe IEEE 1394 digital cameras, Intel Xeon server computer system and Microsoft's DirectShow programming library and its performance is analyzed in terms of image-grabbing frame rate and number of views. The captured two-view image data is compressed by extraction of disparity data between them and transmitted to another client system through the communication network, in which multi-view could be synthesized with this received 2-view data using the intermediate view reconstruction technique and displayed on the multi-view 3D display system. From some experimental results, it is found that the proposed system can display 16-view 3D images with a gray of 8bits and a frame rate of 15fps.

  • PDF

3D Modeling of Building Sides from the Stereo Images for the Realistic Virtual City in 3D GIS

  • Chung, Yun-Koo;Kim, Kyung-Ok;Han, Joon-Hee
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.70-74
    • /
    • 1999
  • Remote sensing (RS) data show the surfaces of the earth only but cannot provide the shape data of building sides. The proposed method recovers a 3D shape of building sides from stereo images. Its result shows a higher possibility for recovering a large shaped object by overcoming the difficulties of traditional stereo matching techniques. The urban area will be visualized more realistically than the current model based on graphic and vector data.

  • PDF

Evaluation of the quality of CGH for 3D image transmission under narrow frequency band

  • Takano, Kunihiko;Kabutoya, Yuta;Noguchi, Mikihiro;Hochido, Syunsuke;Lan, Tian;Sato, Koki;Muto, Kenji
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.673-677
    • /
    • 2009
  • In this paper, a transmitting process of a sequence of holograms describing 3D moving objects over the communicating wireless-network system is presented. A sequence of holograms involves holograms is transformed into a bit stream data, and then it is transmitted over the wireless LAN and Bluetooth. It is shown that applying this technique, holographic data of 3D moving object is transmitted in high quality and a relatively good reconstruction of holographic images is performed.

  • PDF

3D Visualization of Partially Occluded Objects Using Axially Distributed Image Sensing With a Wide-Angle Lens

  • Kim, Nam-Woo;Hong, Seok-Min;Lee, Hoon Jae;Lee, Byung-Gook;Lee, Joon-Jae
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.517-522
    • /
    • 2014
  • In this paper we propose an axially distributed image-sensing method with a wide-angle lens to capture the wide-area scene of 3D objects. A lot of parallax information can be collected by translating the wide-angle camera along the optical axis. The recorded wide-area elemental images are calibrated using compensation of radial distortion. With these images we generate volumetric slice images using a computational reconstruction algorithm based on ray back-projection. To show the feasibility of the proposed method, we performed optical experiments for visualization of a partially occluded 3D object.