• Title/Summary/Keyword: 3D image analysis

Search Result 1,170, Processing Time 0.045 seconds

The Prediction and Analysis of the Propagation Characteristics in Indoor Environments Using the SBR/Image Method (SBR 및 영상기법을 이용한 실내 환경의 전파특성 예측과 분석)

  • 손호경;김채영;김성진
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.199-207
    • /
    • 2001
  • In this paper, the technique of prediction and analysis on the characteristics of propagation in indoor environment is presented. This technique needs no reception sphere commonly used in 3D-ray tracing scheme, and thereby it lends us easy code realization. The validity of developed code is verified by comparing with the values of image methods and measurement. The developed technique applied to the structure of rectangular corridor with the iron door and we calculated the path loss for the variation of the iron door angle. The path loss decreased about 15 dB at the distance of30 m from the iron door and the delay spread increased approximately by four times. Based on the computation, we confirmed that indoor propagation in PCS is heavily affected by the iron door in corridor.

  • PDF

Multiple cracking analysis of HTPP-ECC by digital image correlation method

  • Felekoglu, Burak;Keskinates, Muhammer
    • Computers and Concrete
    • /
    • v.17 no.6
    • /
    • pp.831-848
    • /
    • 2016
  • This study aims to characterize the multiple cracking behavior of HTPP-ECC (High tenacity polypropylene fiber reinforced engineered cementitious composites) by Digital Image Correlation (DIC) Method. Digital images have been captured from a dogbone shaped HTPP-ECC specimen exhibiting 3.1% tensile ductility under loading. Images analyzed by VIC-2D software and ${\varepsilon}_{xx}$ strain maps have been obtained. Crack widths were computed from the ${\varepsilon}_{xx}$ strain maps and crack width distributions were determined throughout the specimen. The strain values from real LVDTs were also compared with virtual LVDTs digitally attached on digital images. Results confirmed that it is possible to accurately monitor the initiation and propagation of any single crack or multiple cracks by DIC at the whole interval of testing. Although the analysis require some post-processing operations, DIC based crack analysis methodology can be used as a promising and versatile tool for quality control of HTPP-ECC and other strain hardening composites.

3D Simulation of Thin Film using Contour Analysis of Interference Fringe Image and Interpolation Method (간섭무늬 영상 등고선 해석과 보간법을 이용한 박막의 삼차원 정보 형상화)

  • Kim, Jin-Hyoung;Ko, Yun-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.2
    • /
    • pp.8-17
    • /
    • 2012
  • In this paper we proposes a new framework to obtain 3D shape information of thin film rapidly. The conventional equipments based on reflectometry are not suitable for obtaining 3D overall shape information of thin film rapidly since they require more than 30 minutes to measure the absolute thickness for 170 points. The proposed framework is based on an image analysis method that extracts contour lines from interference fringes images using Canny edge detector. The absolute thickness for contour lines are measured and then a height map from the contour lines is obtained by interpolation using Borgefors distance transformation. The extracted height map is visualized using the DirectX 3D terrain rendering method. The proposed framework can provide 3D overall shape information of thin film in about 5 minutes since relatively small number of real measurement for contour lines is required.

Human Face Recognition and 3-D Human Face Modelling (얼굴 영상 인식 및 3차원 얼굴 모델 구현 알고리즘)

  • 이효종;이지항
    • Proceedings of the IEEK Conference
    • /
    • 2000.11c
    • /
    • pp.113-116
    • /
    • 2000
  • Human face recognition and 3D human face reconstruction has been studied in this paper. To find the facial feature points, find edge from input image and analysis the accumulated histogram of edge information. This paper use a Generic Face Model to display the 3D human face model which was implement with OpenGL and generated with 500 polygons. For reality of 3D human face model, we propose Group matching mapping method between facial feature points and the one of Generic Face Model. The personalized 3D human face model which resembles real human face can be generated automatically in less than 5 seconds on Pentium PC.

  • PDF

An Easy Camera-Projector Calibration Technique for Structured Light 3-D Reconstruction (구조광 방식 3차원 복원을 위한 간편한 프로젝터-카메라 보정 기술)

  • Park, Soon-Yong;Park, Go-Gwang;Zhang, Lei
    • The KIPS Transactions:PartB
    • /
    • v.17B no.3
    • /
    • pp.215-226
    • /
    • 2010
  • The structured-light 3D reconstruction technique uses a coded-pattern to find correspondences between the camera image and the projector image. To calculate the 3D coordinates of the correspondences, it is necessary to calibrate the camera and the projector. In addition, the calibration results affect the accuracy of the 3D reconstruction. Conventional camera-projector calibration techniques commonly require either expensive hardware rigs or complex algorithm. In this paper, we propose an easy camera-projector calibration technique. The proposed technique does not need any hardware rig or complex algorithm. Thus it will enhance the efficiency of structured-light 3D reconstruction. We present two camera-projector systems to show the calibration results. Error analysis on the two systems are done based on the projection error of the camera and the projector, and 3D reconstruction of world reference points.

An Hardware Error Analysis of 3D Automatic Face Recognition Apparatus(3D-AFRA) : Surface Reconstruction (3차원 안면자동인식기(3D-AFRA)의 Hardware 정밀도 검사 : 형상복원 오차분석)

  • Seok, Jae-Hwa;Song, Jung-Hoon;Kim, Hyun-Jin;Yoo, Jung-Hee;Kwak, Chang-Kyu;Lee, Jun-Hee;Kho, Byung-Hee;Kim, Jong-Won;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.30-39
    • /
    • 2007
  • 1. Objectives The Face is an important standard for the classification of Sasang Constitution. We are developing 3D Automatic Face Recognition Apparatus(3D-AFRA) to analyse the facial characteristics. This apparatus show us 3D image and data of man's face and measure facial figure data. So we should examine the figure restoration error of 3D Automatic Fare Recognition Apparatus(3D-AFRA) in hardware Error Analysis. 2. Methods We scanned Face status by using 3D Automatic Face Recognition Apparatus(3D-AFRA). And also we scanned Face status by using laser scanner(vivid 9i). We compared facial shape data be restored by 3D Automatic Face Recognition Apparatus(3D-AFRA) with facial shape data that be restorated by 3D laser scanner. And we analysed the average error and the maximum error of two data. 3. Results and Conclusions In frontal face, the average error was 0.48mm. and the maximum error was 4.60mm. In whole face, the average error of was 0.99mm. And the maximum error was 6.64mm. In conclusion, We assessed that accuracy of 3D Automatic Face Recognition Apparatus(3D-AFRA) is considerably good.

  • PDF

Biomedical Applications of Stereoscopy for Three-Dimensional Surface Reconstruction in Scanning Electron Microscopes

  • Kim, Ki Woo
    • Applied Microscopy
    • /
    • v.46 no.2
    • /
    • pp.71-75
    • /
    • 2016
  • The scanning electron microscope (SEM) offers two-dimensional (2D) micrographs of three-dimensional (3D) objects due to its inherent operating mechanisms. To overcome this limitation, other devices have been used for quantitative morphological analysis. Many efforts have been made on the applications of software-based approaches to 3D reconstruction and measurements by SEM. Based on the acquisition of two stereo images, a multi-view technique consists of two parts: (i) geometric calibration and (ii) image matching. Quantitative morphological parameters such as height and depth could be nondestructively measured by SEM combined with special software programs. It is also possible to obtain conventional surface parameters such as roughness and volume of biomedical specimens through 3D SEM surface reconstruction. There is growing evidence that conventional 2D SEM without special electron detectors can be transformed to 3D SEM for quantitative measurements in biomedical research.

Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination (디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가)

  • Kim, Seong Min;Hong, Seon Sook;Lee, Kwan Sup;Ha, Dong Yun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF