• Title/Summary/Keyword: 3D direct measurement

Search Result 142, Processing Time 0.02 seconds

Men's Work Clothes Jumper Pattern-making and Its Appearance Evaluation through 3-D Clothing Simulation (3차원 가상착의 시뮬레이션을 이용한 20~50대 연령별 남성 작업복 점퍼 패턴 설계 및 외관평가)

  • Park, Gin-Ah;Lee, Woo-Kyoung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.103-120
    • /
    • 2012
  • The study aimed to evaluate the appearance of the men's work clothes jumpers developed to suggest the prototype work clothes jumper patterns by using the 3-D clothing simulation technology. The 3-D simulated clothing images considered the upper body features of men in the age range between 20 and 59 in South Korea. A questionnaire survey conducted previously suggested a basic jumper style with shirt collar and snap opening cuffs for the heavy industry workers; and discomforting parts of the work clothes jumper of the subject workers have been referred to for the experimental jumper appearance test. Besides, defining the measurements of men's upper bodies enabled to generate the men's 3-D virtual models representing each age group's average body feature. The significant body measurement factors for men's 3-D body modeling and jumper pattern-making were stature for the height factor; chest, waist and hip circumferences for the circumference factor; waist back, hip and arm lengths and interscye front/back for the length factor; and back neck breadth for the breadth factor and armscye and scye depths for the depth factor. The men's body measurements of 30's were implemented to three experimental jumper pattern-making methods, i.e. the 1st method using the relations based on stature and chest circumference; the 2nd method using the direct body measurements; and the 3rd method adopting the maximum ease amount of given body measurements whether relations or direct measurements except the direct measurement of scye depth. A comparison among the three experimental jumpers' simulated images highlighted that the appropriate ease amount of the jumper gained higher scores in terms of the jumpers' front, side, back and sleeve parts and the total silhouettes. Therefore the 3rd experimental jumper was finally selected for the heavy industry workers.

An Approach to Measure Anthropometric Data of Simulated Human Hand Using Photogrammetry (시뮬레이션 환경에서 사진측량기법을 이용한 손 치수 측정 방법에 대한 연구)

  • Chang, Ji Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.5
    • /
    • pp.511-517
    • /
    • 2016
  • Anthropometric data of the hand is one of the important issues for the product design related with hand and manual operation in terms of user-centered design. Direct measurement, which traditionally uses anthropometric measuring tool, has a few disadvantages in cumulation of measuring time, possible errors in raw data, doubtful reliability between inspectors. Newly introduced 3D scanning technology overcomes those disadvantages; however, another disadvantages, such as, hight cost and immovability, have been introduced. In this study, photogrammetric approach was introduced for the measurement of anthropometric data in hand. In order to minimize the possibility of error during direct and indirect measurement, a simulated object was used and effectiveness of photogrametric measurement was confirmed for the collection of anthropometric data in hand.

Linear accuracy of cone-beam computed tomography and a 3-dimensional facial scanning system: An anthropomorphic phantom study

  • Oh, Song Hee;Kang, Ju Hee;Seo, Yu-Kyeong;Lee, Sae Rom;Choi, Hwa-Young;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.111-119
    • /
    • 2018
  • Purpose: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. Materials and Methods: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. Results: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements(P<.05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. Conclusion: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.

Three-dimensional Crush Measurement Methodologies Using Two-dimensional Data (2차원 데이터를 활용한 3차원 충돌 변형 측정 방법)

  • Han, Inhwan;Kang, Heejin;Park, Jong-Chan;Ha, Yongmin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.3
    • /
    • pp.254-262
    • /
    • 2015
  • This paper presents 3D collision deformation modelling methodologies using photogrammetry for reconstruction of vehicle accidents. A vehicle's deformation shape in collision provides important information on how the vehicle collided. So effective measurement(scanning) and construction of a corresponding appropriate model are essential in the analysis of collision deformation shape for obtaining much information related to collision accident. Two measurement methods were used in this study: Indirect-photogrammetry which requires relatively small amount of photos or videos, and direct-photogrammetry which requires large amount of photos directly taken for the purpose of 3D modelling. When the indirect-photogrammetry method, which was mainly used in this study, lacked enough photographic information, already secured 2D numerical deformation data was used as a compensation. This made 3D collision deformation modelling for accident reconstruction analysis possible.

3D Inspection of Printed Circuit Boards (PCB의 3차원 검사)

  • 조홍주;박현우;이준재
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2375-2378
    • /
    • 2003
  • In manufacture of printed circuit boards, one important issue is precisely to measure the three-dimensional shape of the solder paste silk-screened prior to direct surface mounting of chips. This paper presents the 3D shape reconstruction of solder paste using the optical triangulation method based on structured light or slit beam and the measurement algorithm for height, volume. area, and coplanarity on component pads from the 3D range image. Futhermore, statistical process control function is incorporated for process capability analysis.

  • PDF

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

Design of Dual-Band GPS Array Antenna Using In-Direct Feeding Pad (간접급전 패드를 이용한 이중 대역 GPS 배열 안테나 설계)

  • Kang, Seung-Seok;Seo, Seung-Mo;Byun, Gangil;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.355-365
    • /
    • 2017
  • In this paper, we propose the design of a dual-band GPS antenna using in-direct feeding pads. The antenna consists of an upper patch for the GPS L1 band, a lower patch for the GPS L2 band, and two pads on the middle layer for feeding the two radiating patches. A hybrid chip coupler with a phase difference of $90^{\circ}$ is employed at the two feeding ports for achieving a broad circular polarization (CP) bandwidth. The proposed antenna shows bore-sight gains of 3.0 dBic(L1) and 5.1 dBic(L2), and axial ratios of 3.3 dB(L1) and 0.3 dB(L2) by measurement. The active element patterns of the fabricated array with 7 elements show bore-sight gains of -0.4 dBic (L1) and -2.4 dBic(L2), respectively. It proves that the proposed antenna structure is suitable for use in GPS array applications.

Lower Body Type Classification of Women Aged 20-30 for the Development of Riding Breeches (승마바지 개발을 위한 20~30대 성인여성의 하반신 유형 분류)

  • Lee, Ji-Eun;Kwon, Young-Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.8
    • /
    • pp.1075-1094
    • /
    • 2013
  • This study analyzed the lower body type of women aged 20 to 30 to understand their respective characteristics. The research method was restricted to the use of direct measurements data and 3D measurements data of the Sixth Size Korea. Factor analysis, cluster analysis, ANOVA, Duncan's test, discriminant analysis, t-test, and ${\chi}^2$-test were performed for the statistical analysis of the data using SPSS Win 20.0 program. The results of this study are as follows. Lower body type based on 3D measurements were classified into 3 types (obese lower body, long lower body, and small lower body). Lower body type based on direct measurements were classified into 3 types (obese lower body, thick and long lower body, and small lower body). Lower body type based on the direct measurement of sitting pose were classified into 3 types (obese lower body, long and thin lower body, and short lower body). The age differences in the lower body types could be analyzed by an evaluation of the 3D simulation of the lower body.

Optimal pressure and temperature for Cu-Cu direct bonding in three-dimensional packaging of stacked integrated circuits

  • Seunghyun Yum;June Won Hyun
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.3
    • /
    • pp.180-184
    • /
    • 2023
  • Scholars have proposed wafer-level bonding and three-dimensional (3D) stacked integrated circuit (IC) and have investigated Cu-Cu bonding to overcome the limitation of Moore's law. However, information about quantitative Cu-Cu direct-bonding conditions, such as temperature, pressure, and interfacial adhesion energy, is scant. This study determines the optimal temperature and pressure for Cu-Cu bonding by varying the bonding temperature to 100, 150, 200, 250, and 350 ℃ and pressure to 2,303 and 3,087 N/cm2. Various conditions and methods for surface treatment were performed to prevent oxidation of the surface of the sample and remove organic compounds in Cu direct bonding as variables of temperature and pressure. EDX experiments were conducted to confirm chemical information on the bonding characteristics between the substrate and Cu to confirm the bonding mechanism between the substrate and Cu. In addition, after the combination with the change of temperature and pressure variables, UTM measurement was performed to investigate the bond force between the substrate and Cu, and it was confirmed that the bond force increased proportionally as the temperature and pressure increased.

Customized 3D Printed Bolus for Breast Reconstruction for Modified Radical Mastectomy (MRM)

  • Ha, Jin-Suk;Jung, Jae Hong;Kim, Min-Joo;Jeon, Mi Jin;Jang, Won Suk;Cho, Yoon Jin;Lee, Ik Jae;Kim, Jun Won;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.196-202
    • /
    • 2016
  • We aim to develop the breast bolus by using a 3D printer to minimize the air-gap, and compare it to commercial bolus used for patients undergoing reconstruction in breast cancer. The bolus-shaped region of interests (ROIs) were contoured at the surface of the intensity-modulated radiation therapy (IMRT) thorax phantom with 5 mm thickness, after which the digital imaging and communications in mdicine (DICOM)-RT structure file was acquired. The intensity-modulated radiation therapy (Tomo-IMRT) and direct mode (Tomo-Direct) using the Tomotherapy were established. The 13 point doses were measured by optically stimulated luminescence (OSLD) dosimetry. The measurement data was analyzed to quantitatively evaluate the applicability of 3D bolus. The percentage change of mean measured dose between the commercial bolus and 3D-bolus was 2.3% and 0.7% for the Tomo-direct and Tomo-IMRT, respectively. For air-gap, range of the commercial bolus was from 0.8 cm to 1.5 cm at the periphery of the right breast. In contrast, the 3D-bolus have occurred the air-gap (i.e., 0 cm). The 3D-bolus for radiation therapy reduces the air-gap on irregular body surface that believed to help in accurate and precise radiation therapy due to better property of adhesion.