• 제목/요약/키워드: 3D deviation

검색결과 714건 처리시간 0.04초

Effects of inter-implant distance on the accuracy of intraoral scanner: An in vitro study

  • Thanasrisuebwong, Prakan;Kulchotirat, Tharathip;Anunmana, Chuchai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.107-116
    • /
    • 2021
  • PURPOSE. Several studies focused on the accuracy of intra-oral scanners in implant dentistry, but the data of inter-implant distances were not widely mentioned. Therefore, this study aimed to evaluate the effect of distance between two implants on the surface distortion of scanned models generated by intra-oral scanners. MATERIALS AND METHODS. Three models with the distances between two fixed scan bodies of 7, 14, and 21 mm were fabricated and scanned with a highly precise D900L dental laboratory scanner as reference models. Fifteen scans were performed with TRIOS3 and CEREC Omnicam intra-oral scanners. Trueness, precision, and angle deviation of the test models were analyzed (α=.05). RESULTS. There was a significant difference among inter-implant distances in both intraoral scanners (P<.001). The error of trueness and precision increased with the increasing inter-implant length, while the angle deviation did not show the same trend. A significant difference in the angle deviation was found among the inter-implant distance. The greatest angle deviation was reported in the 14-mm group of both scanners (P<.05). In contrast, the lowest angle deviation in the 21-mm group of the TR scanner and the 7-mm of the CR scanner was reported (P<.001). CONCLUSION. The inter-implant distance affected the accuracy of intra-oral scanner. The error of trueness and precision increased along with the increasing distance between two implants. However, the distortions were not clinically significant. Regarding angle deviation, the clinically significant angle deviation may be possible when using intra-oral scanners in the partially edentulous arch.

3D 가상착의를 이용한 스마트 스포츠웨어의 밀착성 평가 (Tightness Evaluation of Smart Sportswear Using 3D Virtual Clothing)

  • 김소영;이희란
    • 한국의류학회지
    • /
    • 제47권1호
    • /
    • pp.123-136
    • /
    • 2023
  • To develop smart sportswear capable of measuring biometric data, we created a close-fitting pattern using two- and three-dimensional (2D and 3D, respectively) methods. After 3D virtual fitting, the tightness of each pattern was evaluated using image processing of contact points, mesh deviation, and cross-sectional shapes. In contact-point analysis, the 3D pattern showed high rates of contact with the body (84.6% and 93.1% for shirts and pants, respectively). Compared with the 2D pattern, the 3D pattern demonstrated closer contact at the lower chest, upper arm, and thigh regions, where electrocardiography and electromyography were primarily carried out. The overall average gap was also lower in the 3D pattern (5.27 and 4.66 mm in shirts and pants, respectively). In the underbust, waist, thigh circumference, and mid-thigh circumference, the cross-section distance between clothing and body was showed a statistically significant difference and evenly distributed in the 3D pattern, exhibiting more closeness. The tightness and fit of the 3D smart sportswear sensor pattern were successfully evaluated. We believe that this study is critical, as it facilitates the comparison of different patterns through visualization and digitization through 3D virtual fitting.

Effect of building volume and opening size on fluctuating internal pressures

  • Ginger, John D.;Holmes, John D.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • 제11권5호
    • /
    • pp.361-376
    • /
    • 2008
  • This paper considers internal pressure fluctuations for a range of building volumes and dominant wall opening areas. The study recognizes that the air flow in and out of the dominant opening in the envelope generates Helmholtz resonance, which can amplify the internal pressure fluctuations compared to the external pressure, at the opening. Numerical methods were used to estimate fluctuating standard deviation and peak (i.e. design) internal pressures from full-scale measured external pressures. The ratios of standard deviation and peak internal pressures to the external pressures at a dominant windward wall opening of area, AW are presented in terms of the non-dimensional opening size to volume parameter, $S^*=(a_s/\bar{U}_h)^2(A_W^{3/2}/V_{Ie})$ where $a_s$ is the speed of sound, $\bar{U}_h$ is the mean wind speed at the top of the building and $V_{Ie}$ is the effective internal volume. The standard deviation of internal pressure exceeds the external pressures at the opening, for $S^*$ greater than about 0.75, showing increasing amplification with increasing $S^*$. The peak internal pressure can be expected to exceed the peak external pressure at the opening by 10% to 50%, for $S^*$ greater than about 5. A dominant leeward wall opening also produces similar fluctuating internal pressure characteristics.

아미노산의 라세미화 반응을 이용한 치아로부터의 연령감정에 관한 연구 (The Study of Age Estimation from Tooth using the Racemization of Aminoacid)

  • Hee-Kyung Kim;Chong-Youl Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제14권1호
    • /
    • pp.43-55
    • /
    • 1989
  • The need of age estimation for identification was increased by complexity of society, and the tooth was used widely for age estimation because of less individual deviation than the other organ. The age estimation using the tooth had several methods. Recently, the one using the racemization of aminoacid in the tooth was admitted more accurate than the other methods, especially in old age. But, this study was not tried in our country, and I would report the result of experiment about age estimation using racemization of dentine. I selected 40-Whole dentine sample from extracted teeth, those were reserved in natural dried condition for 2 weeks~ 1year and calculated the estimation of age from the ratio of D-aminoacid and L-aminoacid (D/L ratio) using gaschromatography and the results were below. 1. The aminoacids showed apparent K/L ratio in dentine were aspartic acid, serine. 2. The aspartic acid showed the highest racemic rate and its rate was 0.0012$\pm$0.0003/yr. 3. The relation between the actual age and K/L ratio was very positive correlation(r+0.954) in the estimation of age using aspartic acid. 4. The deviation between the estimated age using D/L ratio of aspartic acid and actual age was $\pm$3.32.

  • PDF

Accuracy of three-dimensional printing for manufacturing replica teeth

  • Lee, Keun-Young;Cho, Jin-Woo;Chang, Na-Young;Chae, Jong-Moon;Kang, Kyung-Hwa;Kim, Sang-Cheol;Cho, Jin-Hyoung
    • 대한치과교정학회지
    • /
    • 제45권5호
    • /
    • pp.217-225
    • /
    • 2015
  • Objective: Three-dimensional (3D) printing is a recent technological development that may play a significant role in orthodontic diagnosis and treatment. It can be used to fabricate skull models or study models, as well as to make replica teeth in autotransplantation or tooth impaction cases. The aim of this study was to evaluate the accuracy of fabrication of replica teeth made by two types of 3D printing technologies. Methods: Fifty extracted molar teeth were selected as samples. They were scanned to generate high-resolution 3D surface model stereolithography files. These files were converted into physical models using two types of 3D printing technologies: Fused deposition modeling (FDM) and PolyJet technology. All replica teeth were scanned and 3D images generated. Computer software compared the replica teeth to the original teeth with linear measurements, volumetric measurements, and mean deviation measurements with best-fit alignment. Paired t-tests were used to statistically analyze the measurements. Results: Most measurements of teeth formed using FDM tended to be slightly smaller, while those of the PolyJet replicas tended to be slightly larger, than those of the extracted teeth. Mean deviation measurements with best-fit alignment of FDM and PolyJet group were 0.047 mm and 0.038 mm, respectively. Although there were statistically significant differences, they were regarded as clinically insignificant. Conclusions: This study confirms that FDM and PolyJet technologies are accurate enough to be usable in orthodontic diagnosis and treatment.

골프선수의 3차원적 척추구조, 골반변위 및 족압에 관한 연구 (A Study on the Structure of Three Dimentional Spine, Pelvic Deviation and Foot Pressure in Golf Players)

  • 양대중
    • 한국운동역학회지
    • /
    • 제22권2호
    • /
    • pp.151-158
    • /
    • 2012
  • The purpose of this study was to investigate variables of significantly difference as the structure of the spine, pelvic deviation and foot pressure between undergraduates and golf player subjects. The subjects of study were composed of 20 male golf players and 20 male undergraduates. Both groups were right handed persons. The measurement tools of this study were Formetric 4D(Diers, Germany) which is a three dimensional measure. The result are the follows: there were a significant difference between golf players and general students of trunk imbalance, pelvic tilt, pelvic torsion, pelvic rotation, surface rotation, lumbar lordotic curve, foot pressure(fore & behind foot), weight distribution(right & left foot). In conclusion, golf players might cause transform of spine and foot pressure due to golf exercise for several years. Such as imbalance affect to induce functional impairment and pain of musculoskeletal system, and appropriate evaluation and treatment were necessary for golf players.

연속용융도금라인에서 에어나이프 특성이 도금편차에 미치는 영향 (A Study on Coating Deviation Effect by Air Knife Characteristics in CGL)

  • Bae, Y.H.;Ahn, D.S.;Lee, S.H.
    • 한국정밀공학회지
    • /
    • 제10권3호
    • /
    • pp.57-68
    • /
    • 1993
  • Air Wiping technique is widely used because of easy and efficient coating control in present CGL. Coaring weight is decided by nozzle header pressure, strip line speed and distance between strip and nozzle. Coating defects are results from unbalance of these factors and coating equipment calibration inaccuracy. Therefore, this study is mainly dealing with the cause of coating defects such as edge overcoating and coating deviation. The coptimum working condition is suggested by formulated coating model using collected working data. We developed two demension analysis program for air flow in nozzle and calculated dynamic pressure and air velocity with this program. The productivity and coating guality are improved by applying the result of this reserach.

  • PDF

나선형 인덕터의 디임베드 검증을 통한 CMOS LNA 설계 및 제작 (The Design and Fabrication of CMOS LNA through De-embedded Verification of the Spiral Inductor)

  • 이한영;유영길
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2269-2275
    • /
    • 2008
  • This paper examined the simulation results after applying not only spiral inductor's 3D EM simulation but also de-embedding technique to reduce the pad's RF effects. When calculating standard deviation with measurement results not only the gain at 0.5GHz${\sim}$4GHz but also noise figure at 1.8GHz${\sim}$4GHz, the simulation results includes de-embedded inductor' model improved gain deviation by 0.171 and noise figure deviation by 0.151 than the results from simulation with foundry inductor equivalent circuit models.

Frequency Responses of Ambulatory ECG Systems and Their Correction by a Compensation Circuit

  • Iwao, K.;Yokoi, A.;Suzuki, S.;Goto, T.;Doniwa, K.;Okajima, M.
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.13-18
    • /
    • 1990
  • Frequency responses of ambulatory electrocardiogram systems were measured. Phase shift was assessed by our improved Wagner's method. The characteristics of the systems were found much worse than that of ordinary ECG equipment both in gain and phase responses. The decay of -3dB in amplitude observed in 0.2Hz and the lead of 45 dog in phase was observed in 0.6Hz. In order to investigate which of these 2 responses play major role in generating false S -T deviation, mathe- matical filters were Composed in a computer and actual ECGs were fed. The false S-T deviation were found to be caused mostly by enormous lead in phase, and then, the compensation circuit to diminish the lead in phase was inserted in the commercial systemes. The compensated systems showed no false deviation in S-T segment.

  • PDF

Application of Three-dimensional Scanning, Haptic Modeling, and Printing Technologies for Restoring Damaged Artifacts

  • Jo, Young Hoon;Hong, Seonghyuk
    • 보존과학회지
    • /
    • 제35권1호
    • /
    • pp.71-80
    • /
    • 2019
  • This study examined the applicability of digital technologies based on three-dimensional(3D) scanning, modeling, and printing to the restoration of damaged artifacts. First, 3D close-range scanning was utilized to make a high-resolution polygon mesh model of a roof-end tile with a missing part, and a 3D virtual restoration of the missing part was conducted using a haptic interface. Furthermore, the virtual restoration model was printed out with a 3D printer using the material extrusion method and a PLA filament. Then, the additive structure of the printed output with a scanning electron microscope was observed and its shape accuracy was analyzed through 3D deviation analysis. It was discovered that the 3D printing output of the missing part has high dimensional accuracy and layer thickness, thus fitting extremely well with the fracture surface of the original roof-end tile. The convergence of digital virtual restoration based on 3D scanning and 3D printing technology has helped in minimizing contact with the artifact and broadening the choice of restoration materials significantly. In the future, if the efficiency of the virtual restoration modeling process is improved and the material stability of the printed output for the purpose of restoration is sufficiently verified, the usability of 3D digital technologies in cultural heritage restoration will increase.