• Title/Summary/Keyword: 3D deviation

Search Result 719, Processing Time 0.031 seconds

Reduction Factor of the Site Coefficient due to the Foundation Embedment in the Soft Soil Layer for the Seismic Analysis of a Building (건축물의 지진해석을 위한 연약지반에 묻힌 기초로 인한 지반증폭계수에 대한 저감계수)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.1-15
    • /
    • 2010
  • In this study, the reduction factor of the code-defined site coefficient due to the embedment of a foundation was estimated for the seismic analysis of a building built on a soft soil site. This was done by utilizing the in-house finite element software P3DASS, which has the capability of pseudo 3D seismic analysis with nonlinear soil layers. A 30m thick soft soil site laid on the rock was assumed to be homogeneous, elastic, viscous and isotropic, and equivalent circular rigid foundations with radii of 10-70m were considered to be embedded at 0, 10, 20 and 30m in the soil layer. Seismic analyses were performed with 7 bedrock earthquake records deconvoluted from the outcrop records of which the effective ground acceleration was scaled to 0.1g. The study results showed that the site coefficients are gradually reduced except in the case of a small foundation embedded deeply in the weak soil layer, and it was estimated that the deviation of the site coefficients due to the foundation size was not significant. The standard reduction factor due to the foundation embedment were calculated adding the standard deviation to the average of 5 reduction factors calculated for 5 different foundation radii. Standard reduction factors for the site amplification factor were proposed for the practical amplification and the codes of KBC, etc., in accordance with the average shear wave velocity of the site, and the site class.

Accurate Interpretation of Electron Diffraction Data Acquired by Imaging Plates (Imaging Plate에 기록된 전자회절자료의 해석)

  • Kim, Young-Min;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.33 no.3
    • /
    • pp.195-204
    • /
    • 2003
  • The Experimental calibration method has been investigated to correct d-spacing estimation and to identify phases in the electron diffraction data acquired by imaging plates. When the diffraction data from the imaging plate was corrected by the d-spacing calibration method with the radial intensity distribution plotting in this experiment, The accuracy of d-spacing estimation was significantly increased in errors of about 0.5%. The experimental calibration equation followed up the first order exponential decay function was derived from the trace of d-spacing deviation between the measured and the calculated values. It was applied to the analysis of d-spacing and the phase identification of the transitional phases formed from [001] gibbsite specimen by electron beam irradiation effect. In this case more accurate phase identification and d-spacing evaluation is possible for the transitional phases whose diffraction patterns are complicatedly superimposed. It is concluded that ${\chi}$-alumina, ${\gamma}$-alumina and ${\sigma}$-alumina are clearly identified as the major transitional phases formed from gibbsite by electron beam irradiation for 120 min.

Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose

  • Hee Jong Ki;Bum-soo Kim;Jun-Ki Kim;Jai Ho Choi;Yong Sam Shin;Yangsean Choi;Na-Young Shin;Jinhee Jang;Kook-jin Ahn
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.256-263
    • /
    • 2022
  • Objective: This study aimed to evaluate the image quality and dose reduction of low-dose three-dimensional (3D) rotational angiography (RA) for evaluating intracranial aneurysms. Materials and Methods: We retrospectively evaluated the clinical data and 3D RA datasets obtained from 146 prospectively registered patients (male:female, 46:100; median age, 58 years; range, 19-81 years). The subjective image quality of 79 examinations obtained from a conventional method and 67 examinations obtained from a low-dose (5-seconds and 0.10-μGy/frame) method was assessed by two neurointerventionists using a 3-point scale for four evaluation criteria. The total image quality score was then obtained as the average of the four scores. The image quality scores were compared between the two methods using a noninferiority statistical testing, with a margin of -0.2 (i.e., score of low-dose group - score of conventional group). For the evaluation of dose reduction, dose-area product (DAP) and air kerma (AK) were analyzed and compared between the two groups. Results: The mean total image quality score ± standard deviation of the 3D RA was 2.97 ± 0.17 by reader 1 and 2.95 ± 0.20 by reader 2 for conventional group and 2.92 ± 0.30 and 2.95 ± 0.22, respectively, for low-dose group. The image quality of the 3D RA in the low-dose group was not inferior to that of the conventional group according to the total image quality score as well as individual scores for the four criteria in both readers. The mean DAP and AK per rotation were 5.87 Gy-cm2 and 0.56 Gy, respectively, in the conventional group, and 1.32 Gy-cm2 (p < 0.001) and 0.17 Gy (p < 0.001), respectively, in the low-dose group. Conclusion: Low-dose 3D RA was not inferior in image quality and reduced the radiation dose by 70%-77% compared to the conventional 3D RA in evaluating intracranial aneurysms.

A Study on Automatic Calculation of Earth-volume Using 3D Model of B-Rep Solid Structure (B-Rep Solid 구조의 3차원 모델을 이용한 토공량 자동 산정에 관한 연구)

  • Kim, Jong Nam;Um, Dae Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.5
    • /
    • pp.403-412
    • /
    • 2022
  • As the 4th industrial revolution is in full swing and next-generation ICT(Information & Communications Technology) convergence technology is being developed, various smart construction technologies are being rapidly introduced in the construction field to respond to technological changes. In particular, since the earth-volume calculation process for site design accounts for a large part of the design cost at the construction site, related researches are being actively conducted to improve the efficiency of the process and accurately calculate the earth-volume. The purpose of this study is to present a method for quickly constructing the topography of a construction site in 3D and efficiently calculating earth-volume using the results. For this purpose, the construction site was constructed as a 3D realistic model using large-scale aerial photos obtained from UAV(Unmanned Aerial Vehicle). At this time, since the constructed 3D realistic model has a surface model structure in which volume calculation is impossible, the structure was converted into a 3D solid model to enable volume calculation. And we devised a methodology to calculate earth-volume based on CAD(Computer-Aided Design and Drafting) using the converted solid model. Automatically calculating earth-volume from the solid model by applying the method. As a result, It was possible to confirm a relative deviation of 1.52% from the calculated earth-volume from the existing survey results. In addition, as a result of comparative analysis of the process time required for each method, it was confirmed that the time required is reduced of 60%. The technique presented in this study is expected to be utilized as a technology for smart construction management, such as periodic site monitoring throughout the entire construction process, as well as cost reduction for earth-volume calculation.

A Study on the Digital Drawing of Archaeological Relics Using Open-Source Software (오픈소스 소프트웨어를 활용한 고고 유물의 디지털 실측 연구)

  • LEE Hosun;AHN Hyoungki
    • Korean Journal of Heritage: History & Science
    • /
    • v.57 no.1
    • /
    • pp.82-108
    • /
    • 2024
  • With the transition of archaeological recording method's transition from analog to digital, the 3D scanning technology has been actively adopted within the field. Research on the digital archaeological digital data gathered from 3D scanning and photogrammetry is continuously being conducted. However, due to cost and manpower issues, most buried cultural heritage organizations are hesitating to adopt such digital technology. This paper aims to present a digital recording method of relics utilizing open-source software and photogrammetry technology, which is believed to be the most efficient method among 3D scanning methods. The digital recording process of relics consists of three stages: acquiring a 3D model, creating a joining map with the edited 3D model, and creating an digital drawing. In order to enhance the accessibility, this method only utilizes open-source software throughout the entire process. The results of this study confirms that in terms of quantitative evaluation, the deviation of numerical measurement between the actual artifact and the 3D model was minimal. In addition, the results of quantitative quality analysis from the open-source software and the commercial software showed high similarity. However, the data processing time was overwhelmingly fast for commercial software, which is believed to be a result of high computational speed from the improved algorithm. In qualitative evaluation, some differences in mesh and texture quality occurred. In the 3D model generated by opensource software, following problems occurred: noise on the mesh surface, harsh surface of the mesh, and difficulty in confirming the production marks of relics and the expression of patterns. However, some of the open source software did generate the quality comparable to that of commercial software in quantitative and qualitative evaluations. Open-source software for editing 3D models was able to not only post-process, match, and merge the 3D model, but also scale adjustment, join surface production, and render image necessary for the actual measurement of relics. The final completed drawing was tracked by the CAD program, which is also an open-source software. In archaeological research, photogrammetry is very applicable to various processes, including excavation, writing reports, and research on numerical data from 3D models. With the breakthrough development of computer vision, the types of open-source software have been diversified and the performance has significantly improved. With the high accessibility to such digital technology, the acquisition of 3D model data in archaeology will be used as basic data for preservation and active research of cultural heritage.

Interpretation of androgen and anti-Mullerian hormone profiles in a Hispanic cohort of 5- to 8-year-old girls with premature adrenarche

  • Brar, Preneet Cheema;Dingle, Elena;Ovadia, Daniela;Pivo, Sarah;Prasad, Veeramac;David, Raphael
    • Annals of Pediatric Endocrinology and Metabolism
    • /
    • v.23 no.4
    • /
    • pp.210-214
    • /
    • 2018
  • Purpose: Premature adrenarche (PA) often leads to polycystic ovary syndrome (PCOS). Higher anti-mullerian hormone (AMH) levels are reported in PCOS. We studied the androgen profile and AMH profiles in Hispanic girls with PA (aged 5-8 years) and age and body mass index (BMI) matched controls. Methods: Retrospective review of electronic medical records of girls who met the inclusion criteria for premature adrenarche were done. Results: PA girls (n=76) were matched to control girls (n=12) for age (mean${\pm}$standard deviation) ($6.7{\pm}1years$ vs. $6.2{\pm}1.3years$) and BMI ($20{\pm}10kg/m^2$ vs. $17.8{\pm}2.7kg/m^2$). Dehydroepiandrostenedione sulfate ($63.3{\pm}51.3{\mu}g/dL$ vs. $29.8{\pm}17.3{\mu}g/dL$, P<0.001) and testosterone levels ($11.4{\pm}4.8ng/dL$ vs. $8.2{\pm}2.9ng/dL$, P=0.001) were significantly higher in the PA group than controls. AMH values (<14 years: reference range, 0.49-3.15 ng/mL) were $3.2{\pm}2.2ng/mL$ vs. $4.6{\pm}3.2ng/mL$ respectively in the PA and control groups and were not different (P=0.4). AMH did not show a correlation with bone age (P=0.1), and testosterone (P=0.9) in the PA group. 17-hydroxyprogesterone levels (17-OHP ng/dL) were $39.5{\pm}30.5ng/dL$ vs. $36.8{\pm}19.8ng/dL$ in PA versus control girls. The concentration of 17-OHP was not statistically different between the control and PA groups. Conclusion: Higher AMH was not observed in PA girls and no correlation with BA and androgen levels was observed.

Measurement of Autoignition Temperature of Propionic Acid and 3-Hexanone System (Propionic acid와 3-Hexanone 계의 최소자연발화온도의 측정)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.44-49
    • /
    • 2014
  • The autoignition temperaturs (AIT) of solvent mixture is important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AIT and ignition delay time for Propionic acid and 3-Hexanone system by using ASTM E659 apparatus. The AITs of Propionic acid and 3-Hexanone which constituted binary system were $511^{\circ}C$ and $425^{\circ}C$, respectively. The experimental AIT of Propionic acid and 3-Hexanone system were a good agreement with the calculated AIT by the proposed equations with a few average absolute deviation (A.A.D.). And Propionic acid and 3-Hexanone system was shown the minimum autoignition temperature behavior (MAITB).

Effect of Iterative-metal Artifact Reduction (iMAR) at Tomotherapy: a Phantom Study (토모테라피에서 반복적 금속 인공물 감소 알고리즘의 유용성 평가: 팬톰 실험)

  • Daegun, Kim;Jaehong, Jung;Sungchul, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.709-718
    • /
    • 2022
  • We evaluated the effect of high-density aluminum, titanium, and steel metal inserts on computed tomography (CT) numbers and radiation treatment plans for Tomotherapy. CT images were obtained using a cylindrical TomoPhantom comprising cylindrical rods of various densities and metal inserts. Three CT image sets were evaluated for image quality as the mean CT number and standard deviation. Dose evaluation also performed. The reference values did not significantly differ between the CT image sets with the corrected metal inserts. The higher-density material exhibited the largest difference in the mean CT number and standard deviation. The conformity index at Iterative-Metal Artifact Reduction (iMAR) was approximately 20% better than that of non-iMAR. No significant target or organ at risk dose difference was observed between non-iMAR and iMAR. Therefore, iMAR is helpful for target or organ at risk delineation and for reducing uncertainty for three-dimensional conformal radiation therapy in Tomotherapy.

Characteristics and Influence of Scattering Radiation in Cultural Heritage Radiography (문화재 방사선 조사에서 발생하는 산란 방사선의 특성과 영향)

  • Song, Jung Il;Park, Young Hwan;Yu, Ji Hye
    • Journal of Conservation Science
    • /
    • v.34 no.6
    • /
    • pp.539-548
    • /
    • 2018
  • This study was conducted to evaluate the effects of scattering radiation, which was not considered in the cultural Heritage radiography, by evaluating the relationship between the tube voltage (unit: kVp), film-floor-distance(FFD), and lead screen layout. The density (unit: D) of the test specimens and the scattered radiation increased with the tube voltage. The density of the test specimens showed an average deviation of 1.4 D; it was 0.17 D at 60 kVp, 1.54 D at 160 kVp, and 2.97 D at 220 kVp. The mean density of the scattered radiation was 0.10 D at 60 kVp, 0.40 D at 160 kVp, and 0.46 D at 220 kVp. The density tended to increase when the tube voltage ranged between 60 kVp and 160 kVp, as the FFD distance increased. However, a change in the permeation density was not observed for high voltages(160 kVp-220 kVp). Scattered radiation was observed when FFD was 50 mm, 100 mm, and 200 mm and no lead screen was used and the bottom surface was replaced with the lead screen. No scattered radiation was observed when FFD was 0 mm. The identification rate ranged from 2.08% to 2.67%, according to the FFD, for a 160 kVp tube voltage, and from 2.67% to 3.33% for a 220 kVp tube voltage.

THE 3.3 ㎛ PAH FEATURE AS A SFR INDICATOR: PROBING THE INTERPLAY BETWEEN SF AND AGN ACTIVITIES

  • Kim, Ji Hoon;Im, M.;Kim, D.;Woo, J.H.;Park, D.;Imanishi, M.;AMUSES Team, AMUSES Team;LQSONG Team, LQSONG Team
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.281-284
    • /
    • 2012
  • We utilize AKARI's slitless spectroscopic capability to detect the $3.3{\mu}m$ polycyclic aromatic hydrocarbons (PAHs) emission and measure star formation (SF) activity for various AKARI programs. First, we obtain $2{\sim}5{\mu}m$ spectra of 20 flux-limited galaxies with mixed SED classes in order to calibrate the $3.3{\mu}m$ PAH luminosity ($L_{PAH3.3}$) as a star formation rate (SFR) indicator. We find that $L_{PAH3.3}$ correlates with $L_{IR}$ as well as with the $6.2{\mu}m$ PAH luminosity ($L_{PAH6.2}$). The correlations does not depend on SED classes. We find that ULIRGs deviate from the correlation between PAH luminosities and $L_{IR}$, while they do not for the correlation between PAH luminosities. We suggest possible effects to cause this deviation. On the other hand, how AGN activity is linked to SB activity is one of the most intriguing questions. While it is suggested that AGN luminosity of quasars correlates with starburst (SB) luminosity, it is still unclear how AGN activity is connected to SF activity based on host galaxy properties. We are measuring SFRs for the LQSONG sample consisting of reverberation mapped AGNs and PG-QSOs. This is an extension of the ASCSG program by which we investigated the connection between SB and AGN activities for Seyferts type 1s at z ~ 0.36. While we found no strong correlation between $L_{PAH3.3}$ and AGN luminosity for these Seyferts 1s, $L_{PAH3.3}$ measured from the central part of galaxies correlates with AGN luminosity, implying that SB and AGN activities are directly connected in the nuclear region.