• Title/Summary/Keyword: 3D deviation

Search Result 722, Processing Time 0.028 seconds

Comparison of asymmetric degree between maxillofacial hard and soft tissue in facial asymmetric subjects using three-dimensional computed tomography (안면비대칭자의 3차원 전산단층사진 분석에서 경$\cdot$연조직간 비대칭 정도 차이)

  • Kim, Wang-Sik;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.163-173
    • /
    • 2005
  • The purpose of this study was to compare the asymmetric degree between maxillofacial hard and soft tissues in individuals with facial asymmetry. Computerized tomographies (CT) of 34 adults (17 male, 17 female) who had facial asymmetry were taken. The CT images were transmitted to personal computers and then reconstructed into three-dimensional (3D) images through the use of computer software. In order to evaluate the degree of facial asymmetry, 6 measurements were constructed as the hard tissue measurements while 6 counterpart measurements were taken as the soft tissue measurements. The means and standard deviations were obtained for each measurement using 3D measure, then t-test was used to investigate the differences between each hard tissue measurement and the corresponding soft tissue measurement All measurements used in the present study showed statistically significant differences between the hard and soft tissues. The degree of soft tissue asymmetry was smaller than that of corresponding hard tissue asymmetry in case of chin deviation, frontal ramal inclination difference, and frontal corpus inclination difference. On the other hand, the degree of soft tissue asymmetry was greater than that of underlying hard tissue asymmetry in the measurement of lip canting and lip cheilion height difference The present study suggests that asymmetric differences of hard and soft tissue is observed nu facial asymmetric subjects and thus soft tissue analysis is needed in addition to hard tissue analysis when making an evaluation of facial asymmetry.

The Analysis of the Lower Part of Dress Forms Using Three-Dimensional Measurement System (3차원 형상 계측에 의한 인대의 하반신 형태 파악)

  • Lee, Myung-Hee;Jung, Hee-Kyeong
    • Korean Journal of Human Ecology
    • /
    • v.14 no.2
    • /
    • pp.303-312
    • /
    • 2005
  • The purpose of this research is to analyze the lower part of dress forms with different sectional rotation-angles ($e.g.\;9^{\circ},\;15^{\circ},\;30^{\circ},\;45^{\circ}$) using three-dimensional measurement system and to investigate measurement properties for dress making. The dress forms used in this experiment were size 8 and six types: four from Korea and two from Japan. The instrument and tools for three-dimensional measurement was Whole Body 3D scanner (Exyma-WBS2H). The analysis program used in this experiment was Rapid Form 2004 PP1 (INUS technology, Inc, Korea). The measurement of dress forms was done three times with different sectional rotation-angles and its data were analyzed using SPSS WIN 10.0 Package. The following results were obtained: 1. With mean and standard deviation of each measured part, it was found out that the dress forms from two countries were different in size per each part. For example, the Japanese one was relatively large in middle hip and hip, compared to the Korean one. 2. The 3D analysis of the sectional rotation-angles revealed some differences between the two dress forms in sectional length per each part. 3. With cluster analysis results, it was found that there were definite differences among measurements per each part, especially in $30^{\circ}\;and\;45^{\circ}$ sections. 4. The proportion of the dress forms showed significant differences in the curvature between center and side section of the lower parts. In addition, the shapes on the horizontal section map of the four levels (waist, middle hip, hip, and bottom) were analyzed.

  • PDF

A Study on the Classification of Lower Body Shape Type for Fit Evaluation of Slacks (슬랙스 맞음새 평가를 위한 하반신 체형 유형화에 관한 연구)

  • Kim, Seonyoung;Nam, Yunja
    • Journal of Fashion Business
    • /
    • v.20 no.2
    • /
    • pp.181-196
    • /
    • 2016
  • This study intended to suggest criteria for selection of subjects by lower body shape types necessary for evaluating slacks. For this, the characteristics were examined by lower body parts which would influence the fit of slacks on 3D human body shape data of the front and sides of the lower body for lower body shaping. The frequency of subjects by lower body shape types and the boundary points for discrimination of each type were suggested so that they could be available in selecting subjects. Using the data from Size Korea(2004), indirect measurement values measured on the front and sides of the lower body among 3D human body shape data of 175 subjects were analyzed. Their height, waist, and hip circumference fell under the range of standard deviation based on the mean of women aged 18~24 years, and then lower body shaping was conducted by combining the front and side shapes of the lower body. The front of the lower body was classified into four sections: average waist/average hip type(F1), average waist/narrow hip tyle(F2), narrow waist/narrow hip type(F3) and narrow waist/wide hip type(F4) and the sides of the lower body were divided into four sections: average abdomen/average hip type(S1), flat abdomen/average hip type(S2), average abdomen/protrude hip type(S3)and round abdomen/flat hip type(S4), and thus total 16 lower body types were created by cross analysis. Besides, discriminant analysis suggested the boundary points for each shape type of the front and sides of the lower body as a criterion for deciding lower body shape type of each subject

2-6 GHz Digital Phase Shifter Module (2-6 GHz 디지털 위상변위기 모듈)

  • Jeong, Myeong-Deuk;So, Jun-Ho;U, Byeong-Il;Im, Jung-Su;Lee, Sang-Won;Park, Dong-Cheol
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.3
    • /
    • pp.158-164
    • /
    • 2002
  • 2-6 GHz digital phase shifter module has been designed and fabricated. For the broadband operation and performance, MMIC phase shifter chip for phase shifter module was designed and fabricated by using the reflection-type circuits with Lange coupler. The fabricated phase shifter module shows 6.1$^{\circ}$RMS phase error, 13.5 dB maximum insertion loss, and 8 dB and 10 dB input and output return losses, respectively. Computer controlled measurement systems are realized in order to get the measured data of 32 phase states. The RMS insertion phase error and the average insertion loss deviation among 8${\times}$8 modules for the phased-array system are less than ${\pm}$0.5$^{\circ}$and ${\pm}$0.5 dB, respectively. The size of fabricated phase shifter module is 45 ${\times}$ 22.5 ${\times}$60㎣.

Construction of Precise Mine Geospatial Information and Ore Modeling for Smart Mining (스마트마이닝을 위한 정밀 광산공간정보 구축 및 광체 모델링)

  • Park, Joon Kyu;Jung, Kap Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.725-731
    • /
    • 2020
  • In mineral resource development, resource exploration is a task to find economical minerals on the surface and underground, and the success rate is low compared to the development and production stages, and it is necessary to collect a lot of data through exploration and accurately analyze the collected information. In this study, mine spatial information was constructed using a 3D (Three-dimensional) laser scanner, and accuracy evaluation was performed to obtain a maximum deviation of 0.140 m and an average of 0.095 m in the X, Y and Z directions, and the possibility of utilizing the construction of mine geospatial information through a 3D laser scanner could be presented. In addition, the ore body modeling was performed by applying the interpolation method of the ore body section using the resource exploration results. The ore body modeling result was superimposed with the modeling result of the mine geospatial information built through the 3D laser scanner to construct the ore body modeling result based on the precise mine geospatial information. The results of ore body modeling based on mine geospatial information built through research can increase the ease of data interpretation and the accuracy of the calculated data, which will greatly increase the efficiency of work related to mineral resource development and mine damage prevention in the future.

Cytomegalovirus Infection in Pediatric Renal Transplant Recipients: A Single Center Experience

  • Kim, Mi Jin;You, Ji Hye;Yeh, Hye Ryun;Lee, Jin A;Lee, Joo Hoon;Park, Young Seo
    • Childhood Kidney Diseases
    • /
    • v.21 no.2
    • /
    • pp.75-80
    • /
    • 2017
  • Purpose: To investigate the frequency, presentation, management, and outcome of cytomegalovirus (CMV) infection in pediatric patients who underwent renal transplantation. Methods: We performed a retrospective chart review of 70 patients under the age of 18, who underwent renal transplantation between January 1990 and November 2014. A diagnosis of CMV infection was based on serology, molecular assays, antigenemia assays, and culture. CMV infection was defined as detection of virus and CMV disease was diagnosed when clinical signs and symptoms were present. Results: The number of patients with CMV infection was 18 (25.7% of renal transplant recipients). Twelve were male (66.7%), and the $mean{\pm}standard$ deviation (SD) age at infection was $13.3{\pm}3.9$ years. Median time of infection after renal transplantation was 4 months (range 1.0-31.0 months). Pretransplantation CMV status in the infected group was as follows: donor (D)+/recipient (R)+, 11 (61.1%); D+/R-, 7 (38.9%); D-/R+, 0; and D-/R- 0. Nine patients had CMV disease with fever, leukopenia, thrombocytopenia, or organ involvement such as enteritis, hepatitis, and pneumonitis. The age of disease occurrence was $13.1{\pm}3.9$ years and the median time to disease onset after renal transplantation was 8 months (range 1.0-31.0). Immunosuppressive agents were reduced or discontinued in 14 patients (77.8%), antiviral agents were used in 11 patients (61.1%), and all patients with CMV infection were controlled. Conclusions: A quarter of the patients had CMV infection about 4 months after renal transplantation. CMV infection was successfully treated with reduction of immunosuppressants or with antiviral agents.

Estimation of Genetic Parameters from Longitudinal Records of Body Weight of Berkshire Pigs

  • Lee, Dong-Hee;Do, Chang-Hee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.6
    • /
    • pp.764-771
    • /
    • 2012
  • Direct and maternal genetic heritabilities and their correlations with body weight at 5 stages in the life span of purebred Berkshire pigs, from birth to harvest, were estimated to scrutinize body weight development with the records for 5,088 purebred Berkshire pigs in a Korean farm, using the REML based on an animal model. Body weights were measured at birth (Birth), at weaning (Weaning: mean 22.9 d), at the beginning of a performance test (On: mean 72.7 d), at the end of a performance test (Off: mean 152.4 d), and at harvest (Finish: mean 174.3 d). Ordinary polynomials and Legendre with order 1, 2, and 3 were adopted to adjust body weight with age in the multivariate animal models. Legendre with order 3 fitted best concerning prediction error deviation (PED) and yielded the lowest AIC for multivariate analysis of longitudinal body weights. Direct genetic correlations between body weight at Birth and body weight at Weaning, On, Off, and Finish were 0.48, 0.36, 0.10, and 0.10, respectively. The estimated maternal genetic correlations of body weight at Finish with body weight at Birth, Weaning, On, and Off were 0.39, 0.49, 0.65, and 0.90, respectively. Direct genetic heritabilities progressively increased from birth to harvest and were 0.09, 0.11, 0.20, 0.31, and 0.43 for body weight at Birth, Weaning, On, Off, and Finish, respectively. Maternal genetic heritabilities generally decreased and were 0.26, 0.34, 0.15, 0.10, and 0.10 for body weight at Birth, Weaning, On, Off, and Finish, respectively. As pigs age, maternal genetic effects on growth are reduced and pigs begin to rely more on the expression of their own genes. Although maternal genetic effects on body weight may not be large, they are sustained through life.

Drift and Volatilization of Some Pesticides Sprayed on Chinese Cabbages (배추에 살포된 몇 가지 농약제제에 따른 성분의 휘산과 비산)

  • Lee, Ja-Young;Han, Il-Keun;Lee, Sang-Yun;Yeo, Ik-Hyun;Lee, Su-Rae
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.4
    • /
    • pp.373-381
    • /
    • 1997
  • In order to investigate the drift of pesticides sprayed on Chinese cabbage, 7 pesticides chlorpyrifos, EPN, pirimiphos-methyl, phenthoate, tetradifon, dicofol and bifenthrin were applied in two sets of field tests. The pesticide residues were quantified bar multiple-residue analysis, in which the recovery rate was 78${\sim}$92% and standard deviation was ${\pm}0.683{\sim}52%$. It was found that most of the tested pesticides were spread by drift to neighbouring area and brought about the contamination of the unsprayed crops. The extent of drift varied depending upon the pesticide, distance and wind direction. The mean residue levels on unsprayed crops were 0.66% at 3 meter distance, 0.10% at 6 m distance and 0.05% at 9 m distance from the applied area and the maximum level was 1.83% of the residue on sprayed crops.

  • PDF

A New Method for Aortic Valve Planimetry with High-Resolution 3-Dimensional MRI and Its Comparison with Conventional Cine MRI and Echocardiography for Assessing the Severity of Aortic Valvular Stenosis

  • Hae Jin Kim;Yeon Hyeon Choe;Sung Mok Kim;Eun Kyung Kim;Mirae Lee;Sung-Ji Park;Joonghyun Ahn;Keumhee C. Carriere
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1266-1278
    • /
    • 2021
  • Objective: We aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique. Materials and Methods: We included 139 consecutive patients (mean age ± standard deviation [SD], 68.5 ± 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 ± 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation. Results: The mean AVA ± SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 ± 0.26 cm2, 0.82 ± 0.34 cm2, and 0.80 ± 0.26 cm2, respectively (p = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94-0.97) and 0.87 (95% CI, 0.82-0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96-0.98) and 0.98 (95% CI, 0.97-0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89-0.94) and 0.91 (95% CI, 0.88-0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82-0.91) vs. 0.85 (95% CI, 0.79-0.89). Conclusion: High-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.

A Compact Rotman Lens with Wide Angle Steering Characteristics (광각 빔조향 특성을 갖는 소형 로트만 렌즈)

  • 이광일;김인선;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.5
    • /
    • pp.500-506
    • /
    • 2002
  • This paper presents a design of wide angle steering microstrip Rotman lens operating over broadband frequency range for Electronic Warfare equipments. It has a compact and simple structure which it is easy to manufacture repetitively. The lens is modelled as a 2-dimension planar circuit, the contour integral method is performed over entire lens contour and the transmission coefficients from 8 beam ports to 8 array ports are found. The measured results are well agreed with those of analysis. Prediction of the multibeam array pattern fed by linear array antenna shows $\pm$65$^{\circ}$ of beam steering and $\pm$5 dB insertion loss deviation over 3:1 frequency range.