• 제목/요약/키워드: 3D deviation

Search Result 719, Processing Time 0.034 seconds

A Study on DCT Hierarchical LMS DFE Algorithm to Improve the Performance of ATSC Digital TV Broadcasting (ATSC 디지털 TV 방송수신 성능개선을 위한 DCT 계층적 LMS DFE 알고리즘 연구)

  • 김재욱;서종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.7A
    • /
    • pp.529-536
    • /
    • 2003
  • In this Paper, a new DCT HLMS DFE(Discrete Cosine Transform Hierarchical Least Mean Square Decision Feedback Equalizer) algorithm is proposed to improve the convergence speed and MSE(Mean Square Error) performance of a receive channel equalizer in ATSC(Advanced Television System Committee) 8VSB(Vestigial Side Band) digital terrestrial TV system. The proposed algorithm reduces the eigenvalue range of input data autocorrelation by transforming LMS (Least Mean Square) DFE into the subfilter of hierarchical structure. Moreover, the use of DCT and power estimation algorithm makes it possible to reduce the eigenvalue deviation of input data which results from distortion and delay of the receive signal in the miulti-path environment. Simulation results show that proposed DCT HLMS DFE has SNR improvement of approximately 3.8dB, 5dB and 2dB as compared to LMS DFE when the equalized symbol error rate is 0.2 in ATTC defined digital terrestrial TV broadcasting channels A, B and F, respectively.

Adhesion properties and Breakdown behaviors of LSR Interface (LSR 계면의 접착특성 및 절연파괴거동)

  • Yoon, Seung-Hoon;Nam, Jin-Ho;Lee, Gun-Ju;Choi, Soo-Geol;Shin, Doo-Sung;Ji, Eung-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.232-235
    • /
    • 2002
  • Recently developed liquid silicone rubber (LSR) can be cured by platinum catalyzed additional hydrosilylation mechanism and has the advantage of no byproduct compared to traditional millable peroxide curing silicone rubber. We investigated the characteristics of dielectric breakdown of silicone rubber and adhesion properties between semi-conductive LSR and insulating LSR for high voltage application of pre-molded joint (PMJ). In order to understand the dielectric breakdown characteristics, we used the sheet samples and the paired type rogowski insert electrode system. The breakdown strength and adhesion strength of LSR (E-3) were superior to those of several silicone rubbers. Adhesion strength could be improved by curing at high temperature without post-curing process or enhanced by post-curing process. When LSR (E-3) was cured at $(150^{\circ}C{\times}10min$ semi-conductive )${\times}$ ($175^{\circ}C{\times}10min$ insulation), it showed the high breakdown strength with low standard deviation, and good adhesion strength. In this results, we could apply this process to the fabrication of PMJ without post-curing.

  • PDF

The Singular Position Detection Method from the Measured Path Loss Data for the Cellular Network (이동 통신 망에서 측정하여 계산된 경로 손실의 급격한 변동 위치 추출 방법)

  • Park, Kyung-Tae;Bae, Sung-Hyuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2014
  • The path loss data was re-calculated according to the distance between the base station and a mobile station in the mobile telecommunications network. In this paper, the averaged path loss data was plotted with the conventional path loss models(free space, plane earth, Hata model ${\ldots}$). The standard deviations for the 2 Km, 1 Km, 0.5 Km-interval averaged path loss were 2.29 dB, 3.39 dB, 4.75 dB, respectively. Additionally, the derivative values for the 2 Km, 1 Km, 0.5 Km-interval averaged path loss were evaluated to find the positions with more than 1 times or 2times of the standard deviation. The situations with the sharply fluctuated path loss were calculated to 5 positions in the 2 Km interval, to 7 positions in the 1 Km interval, to 19 positions in the 0.5 Km interval, respectively. And, the exact distances between the base station and a mobile station were found with the sharply fluctuated path loss.

The Immediately Effects of PNF Combined Pattern Movement on Balance, Proprioception and Flexibility Using 3D Newton Box (3D Newton Box를 이용한 PNF 통합패턴운동이 균형, 고유감각, 유연성에 미치는 즉각적 효과)

  • Kim, Jeong-Ja;Kim, Dae-Hyoung;Kim, Jae-Hee;Bae, Jin-Seon;Seo, Jin-Ju;Song, Yoon-A;Jang, Hyeon-Ju
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.1
    • /
    • pp.159-166
    • /
    • 2020
  • This study was conducted on 20 healthy adults in their 20s to identity the immediate effects of balance, proprioception and flexibility after conducting the PNF combined patterns using 3D Newton box. The data collected in this study were analyzed using the SPSS Window 19.0 statistical program, and the general characteristics of the subjects were calculated by calculating the mean and standard deviation using the technical statistics, and the differences before and after in-group balance, proprioception and flexibility were analyzed by the paired t-test. The balance, proprioception and flexibility of the subjects were measured using Y-balance, one-leg standing, and finger bottom contact. The exercise was applied with an combined pattern of PNF in the 3D Newton box. After exercise, balance, proprioception and flexibility all increased significantly. The results show that combined pattern of PNF using the 3D Newton box immediately works for the balance, proprioception and flexibility of adults in their 20s. Therefore, it is considered to be an exercise that can be actively utilized for adults or patients at high risk of damage due to reduced balance, proprioception and flexibility.

The Structure and Energy of D-Sorbitol from an Empirical force-Field (Empirical Force-Field 방법에 의한 D-Sorbitol 의 구조와 에너지에 관한 연구)

  • Park Young Ja
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.104-110
    • /
    • 1985
  • Empirical force-field method has been applied to D-sorbitol, the crystal structure of which has been studied by the single crystal X-ray and neutron diffraction analyses. The calculated C-C bond lengths agree with those observed within 0.009${\AA}$. The C-O bond lengths show a larger deviation of 0. 023${\AA}$. The calculated C-C-C and C-C-O valence angles agree with those observed within $2.3^{\circ}$ and $1.9^{\circ}$respectively. Because torsion angles are influenced by packing forces, they show considerably flarger r. m. s. deviations. Calculations of the conformational energies of the model compound at selected C(1)-C(2)-C(3)-C(4) torsion angles made with the program MMI, produced result that the prediction of the observed preferred conformation of the carbon chain appeares to be less satisfactory.

  • PDF

Determination of In-Vivo Glenohumeral Translation During Loaded and Unloaded Arm Elevation

  • Nishinaka, Naoya;Mihara, Kenichi;Suzuki, Kazuhide;Makiuchi, Daisuke;Matsuhisa, Takayuki;Tsutsui, Hiroaki;Kon, Yoshiaki;Banks, Scott A.
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.44-44
    • /
    • 2009
  • The purpose of this study was to investigate humeral translation relative to the glenoid invivo during loaded and unloaded shoulder abduction. CT scans of 9 healthy shoulders were acquired and 3D models were created. The subject was positioned in front of a fluoroscope and motions were recorded during active abduction. The subjects performed two trials of holding a 3kg weight and unload. 3D motions were determined using model-based 3D-to-2D registration to obtain 6 degrees of freedom kinematics. Glenohumeral translation was determined by finding the location on the humeral head with the smallest separation from the glenoid. Humeral translation was referenced to the glenoid center in the superior/inferior direction. The humerus moved an average of 2 mm, from inferior to central on the glenoid, during arm abduction for both conditions. The humeral head was centered within 1mm from the glenoid center above $70^{\circ}$. There were no statistically significant differences for both conditions. The standard deviation decreased gradually over the motion, with significantly lower variability at the end of abduction compared to the initial unloaded position. We assumed that the humeral translation to the center of the glenoid provides maximum joint congruency for optimal shoulder function and joint longevity. We believe this information will lead to better strategies to prevent shoulder injuries, enhance rehabilitation, and improve surgical treatments.

  • PDF

Comparing volumetric and biological aspects of 3D-printed interim restorations under various post-curing modes

  • Song, Gun;Son, Ji-Won;Jang, Ji-Hyun;Choi, Sung-Hyeon;Jang, Woo-Hyung;Lee, Bin-Na;Park, Chan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose. This study aims to compare the volumetric change, degree of conversion (DOC), and cytotoxicity of 3D-printed restorations post-cured under three different conditions. Materials and Methods. 3D-printed interim restorations were post-cured under three different conditions and systems: 5 min, 30 min, and 24 h. Three-unit and six-unit fixed dental prostheses (n = 30 for each case) were printed; ten specimens from each group were post-cured and then scanned to compare their volumetric changes. Root-mean-squared (RMS) values of the data were acquired by superimposing the scanned files with original files. Thirty disk-shaped specimens were printed to evaluate the DOC ratio. Fourier transform infrared spectroscopy was used to compare the DOCs of 10 specimens from each group. Human gingival fibroblasts were used to measure the cell viability of every specimen (n = 7). The data from this experiment were employed for one-way analysis of variance and Tukey's post-hoc comparisons. Results. Differences between the three-unit restorations were statistically insignificant, regardless of the post-curing conditions. However, for the six-unit restorations, a high RMS value was acquired when the post-curing duration was 30 min. The average DOC was approximately 56 - 62%; the difference between each group was statistically insignificant. All the groups exhibited cell viability greater than 70%, rendering them clinically acceptable. Conclusion. The post-curing conditions influenced the volume when the length of the restoration was increased. However, this deviation was found to be clinically acceptable. Additionally, post-curing did not significantly influence the DOC and cytotoxicity of the restorations.

Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based

  • Graf, Tobias;Guth, Jan-Frederik;Diegritz, Christian;Liebermann, Anja;Schweiger, Josef;Schubert, Oliver
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.351-360
    • /
    • 2021
  • PURPOSE. The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS. A titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (P < .05). RESULTS. Median and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (±SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 ± 7 ㎛ in group CF and 34 ± 6 ㎛ in group PC. RMSE of total adjustments was 61 ± 11 ㎛ in group PC. Quality of occlusal contacts was better in group CF. CONCLUSION. Time effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable.

Evaluation of marginal and internal accuracy of provisional crowns manufactured using digital light processing three-dimensional printer (DLP 방식의 3D 프린터로 제작된 임시 보철물의 변연 및 내면 정확도 평가)

  • Noh, Mi-Jun;Lee, Ha-Bin;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.44 no.2
    • /
    • pp.31-37
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the accuracy of provisional crowns manufactured using a milling machine and a digital light processing (DLP) printer. Methods: A full-contour crown was designed using computer-aided design software. Provisional crowns of this design were manufactured using a milling machine and using a DLP three-dimensional (3D) printer (N=20). The provisional crowns were digitized with an extraoral scanner, and 3D deviation analysis was applied to the scanned data to confirm their accuracy. An independent t-test was performed to detect the significant differences, and the Kolmogorov-Smirnov test was used for analysis (α=0.05). Results: No significant differences were found among the precision of marginal surface between the printed and milled crowns (p=0.181). The trueness of marginal and internal surfaces of the milled crowns were statistically higher than those of the printed crowns (p=0.024, p=0.001; respectively). Conclusion: The accuracy of provisional crowns manufactured using a milling machine and a 3D printer differed significantly except with regards to the precision of the internal surface. However, all the crowns were clinically acceptable, regardless of the manufacturing method used.

Effect of Air-circulation Ways on Air Uniformity and Mushroom Quality in a Cultivation Facility for Oyster Mushroom (공기순환 방법이 느타리버섯 재배사 공기균일도 및 버섯품질에 미치는 영향)

  • Yum, Sung-Hyun;Park, Hye-Sung
    • Journal of Mushroom
    • /
    • v.20 no.3
    • /
    • pp.127-137
    • /
    • 2022
  • Effects of substrate bed interior environments on mushroom qualities were investigated in oyster mushroom cultivation facilities in which either Reversible Air-Circulation Fans (RACF) blowing air in two directions (upwards and downwards) or customary Convection Fans (CF) with air blowing only upwards were operated throughout the cultivation period. Two days before harvest, the deviation ranges of the bed interior temperature and relative humidity in the facility using RACF were in the ranges of 1.0-1.3℃ and 7.8-9.0% in the first growing cycle, and within 0.7-1.1℃ and 10.0-11.4% in the second cycle. In the facility using CF, the ranges of variation in the indoor environment parameters (5.8-6.4℃ and 21.3-23.1% in the first growing cycle, and 3.4-5.7℃ and 14.6-18.3% in the second growing cycle) were much enlarged compared to those associated with RACF. These results strongly indicate that RACF significantly enhances air uniformity. Some mushroom qualities differed between growing cycles. For instance RACF in the first cycle gave somewhat better qualities than CF, but some qualities, like pileus diameter and stipe length, were slightly lower than those described for CF in the second cycle when the cultivation substrate weakened. The observation that some qualities worsened under RACF conditions, despite better air uniformity during the growing cycle, revealed the possibility that downward wind may exert a non-negligible negative effect on mushroom growth. Therefore in the future, making wind measurements on the interior and exterior of substrate beds is necessary to obtain insights into their influences on mushroom qualities. The RACF operation manual needs to be edited to convey this necessity.