• 제목/요약/키워드: 3D body scan

검색결과 189건 처리시간 0.027초

19세기 후반 영국 여성복 상의 착용에 따른 인체 실루엣 변화 (A Study on Body Silhouette Change by Wearing English Women's Upper Garments of the Late $19^{th}$ Century)

  • 차주은;천종숙
    • 복식문화연구
    • /
    • 제19권6호
    • /
    • pp.1205-1220
    • /
    • 2011
  • The purpose of this study is to verify the change of body posture by putting on the late $19^{th}$ century English women's bodice or waistcoat. This study analyzed the female somatotype which puts on upper garments of Victorian era with using 3D body scan technology. Two sets of $19^{th}$ century women's bodice and waistcoat patterns were developed with the $19^{th}$ century model size and those patterns were used for making the experimental garments. The fit of experimental garments was evaluated by the degree of change with posture and waist measurements. Three women with the same waist girth measurements with the model size were participated to the fitting test. The postural change was measured from cross-sectional body diagrams. The result of this study showed that the waist measurement of the late $19^{th}$ century English women's bodice and waistcoat pattern was smaller than the waist girth measurement. These garments compressed the midriff of the body and it made women's distinct body silhouette. The waist girth measurement of 1876 bodice pattern was 9.2cm smaller than presented model size. The subjects' waist girth measurements were shortened by 5.0~6.1cm after wearing the 1876 bodice garment. The waist girth measurement of 1880 waistcoat pattern was 7.1cm smaller than presented model size. The subjects' waist girth measurements were shortened by 2.7~3.7cm after wearing the 1880 waistcoat garment. The back side parts of their waist were compressed and their postures were changed. The neck and shoulders were moved forward after wearing the experimental garments. These results showed that body posture could be changed to "S" shape silhouette as wearing the late $19^{th}$ century English women's bodice or waistcoat.

3차원의 바람직한 유방형상 구현을 위한 Semi-Atomatic Protocol 개발 및 브래지어 컵 패턴으로의 전개 (Development of a Semi-Atomatic Protocol for embodiment of a desirable 3D breast shape and deployment of bra cup pattern)

  • 손부현;권수애
    • 패션비즈니스
    • /
    • 제20권4호
    • /
    • pp.189-206
    • /
    • 2016
  • A breast model was for the human body was devised by studying a body scan and human body index of a desirable breast type. Thus, when manufacturing various 3D models, these results can accordingly become a fundamental basis for realizing a desirable breast model. This study aims to provide a basic data for designing the cup patterns of brassieres in order to improve the function and wearing comfort. The comfort of three kinds of brassieres were compared: one manufactured by the actual measured size; another manufactured as per the ratio of desirable upper and lower breast lengths; and the third manufactured by the 3D model attained by the desirable human body ratio. In this study, we suggest a process for realizing the desirable breast model using the ratio of bust breadth and waist front length, which are the components for deciding the appropriate position and size of breast, and which are easy to measure. The ideal breast shape is an equilateral triangle formed by connecting the nipple with the center of the clavicle. After deciding the interval between the nipples, this value can be used to configure the locations of nipples by drawing a tangent, with equal length, from the anterior neck point (which is the center of clavicle) to the nipple. Also, since inside points of breast do not exist, the outer point of breast, upper point of breast, and below point of breast on the same plane, and the depths from the nipple point to the respective points, are applied to simulate a 3D image, by modifications along the x, y, and z axes. Depending on the type of breast, the length from the center of shoulder to the nipple, the diameter of breast, upper length of breast, and the position of nipple, are different. In conical or protruding breast, the wearing sensation is better when the nipple point of brassiere was lifted, by modifying the upper and lower lengths of breast. Considering the wearing sensation and function of a brassiere, it was better to leave the wearer's size as it is and use a pad within the same cup, rather than increase the basal area of the breast in order to increase the volume.

기능성 전문테니스화의 족저압력분포 분석 (A Study of In-sole Plantar Pressure Distribution in Functional Tennis Shoes)

  • 이중숙;김용재;박승범
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.99-118
    • /
    • 2004
  • The aim of this study is to evaluate tennis shoes's plantar pressure distribution in tennis prayers and to determine the influence of the shoe on various tennis movements. When investigating the biomechanics of movement in tennis, one of the first things to do is to understand the movement patterns of the sport, specifically how these patterns relate to different tennis shoes. Once these patterns are understood, footwear company can design tennis shoes that match the individual needs of tennis players. Plantar pressure measurement is widely employed to study foot function, the mechanical pathogenesis for foot disease and as a diagnostic and outcome measurement tool for many performance. Measurements were taken of plantar pressure distribution across the foot and using F-Scan(Tekscan Inc.) systems respectively. The F-Scan system for dynamic in-shoe foot pressure measurements has enabled us to assess quantitatively the efficacy of different types of footwear in reducing foot pressures. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right, left shoes. For this study 4 university male, high level tennis players were instructed to hit alternated forehand stroke, backhand stroke, forehand volley, backhand volley, smash, service movement in 4 different tennis shoes. 1. When impact in tennis movement, peak pressure distribution of landing foot displayed D>C>B>A, A displayed the best low pressure distribution. A style's tennis shoes will suggest prayer with high impact. If prayer with high impact feeling during pray in tennis wear A style, it will decrease injury, will have performance improvement. 2. When impact in tennis movement, plantar pattern of pressure distribution in landing foot displayed B>A>C>D in stability performance. During tennis, prayer want to stability movement suggest B style tennis shoes when tennis movement impact keep stability of human body. B style tennis shoes give performance improvement 3. When impact in tennis movement, plantar pattern of center of force(C.O.F.)trajectory in landing foot analyzed this : 1) When stroke movement and volley movement in tennis, prayer better to rearfoot movement. 2) when service movement, prayer midfoot strike movement. 3) when smash movement, prayer have forefoot strike movement.

안구차폐체 제작에 필요한 안면부 3차원 정보 구현의 기초연구 (Preliminary Research on the Implementation of Information of Human Facial Part Required for the 3D Printing of Eye Shield)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.955-960
    • /
    • 2019
  • 전산화단층검사는 많은 방사선을 받을 수 있으며, 한 명의 환자에서 반복적으로 시행되는 경우가 위험도는 매우 높다. 어린이의 경우에 방사선에 의한 암 발생률이 더 높다고 보고하고 있다. 3D 프린트는 여러 분야에 적용하기 위해서 연구되고 있으며, 여러 응용 분야중 방사선 차폐체 제작 및 재료에 대한 연구가 최근 진행되고 있다. 3D 프린터의 목적은 기존의 판넬 형태의 차폐체를 대체하고 인체의 형태를 따라 맞춤형 제작을 하는 것이 최종 목적이기 때문에 3D 프린터에 입력할 3차원정보처리에 대한 연구도 매우 중요하다. 본 연구에서는 스테레오 비전의 깊이지도(depth map) 생성 기술을 이용하여 환자 맞춤형 안구차폐체 제작의 전단계인 인체표면의 3차원 데이터를 계산하고 활용 가능성을 연구하고자 하였다. 알려진 3차원 정보처리의 방법들에 비해서 비교적 간단한 방법으로 제안된 결과 안면부 3차원 정보추출을 위한 최소한의 정보가 추출되었다. 본 연구의 결과는 자연광을 적용한 스테레오영상의 장점과 한계점을 제공하였고 향후 안구 차폐체 제작을 위한 기초자료가 될 것으로 판단한다.

3D 가상착의 시스템에 의한 비만 중년여성의 토르소 원형설계에 관한 연구 (A Development of the Torso Pattern for Obese Middle-aged Women from 3D Virtual Garment Simulation)

  • 임지영
    • 한국의류산업학회지
    • /
    • 제12권1호
    • /
    • pp.86-93
    • /
    • 2010
  • The purpose of this study was to develop torso pattern of Middle-aged obese women by using the virtual twin and 3D virtual garment simulation system. The results were as follows; 1. By using 3D Virtual Garment Simulation, new torso pattern considered obese women was development. The basic numerical formula were as follows ; bust girth B/2+5, armhole depth B/6+5, front waist girth W/4+2+0.5, back waist girth W/4+1-0.5, front hip girth H/4+1+0.5, back hip girth H/4+2-0.5, chest width B/6+2.5, back width B/6+2.5 and back neck width B/20+2.5. 2. According to the results of the new torso pattern's appearance evaluation, it estimated more highly than existing pattern in silhouette and ease amount, confirming that new torso pattern is appropriate for the obese women. Also, new torso pattern was evaluated to allow proper space length of bust, waist, abdomen and hip. Virtual models production through 3D body scan data, pattern draft and virtual garment digital program were applied to prototypic design method so as to enhance the fitness of ready-made garments. This study is expected to serve as one of important basic data for ensuing studies that may utilize 3D Virtual Garment Simulation System with 2D patterns, and also for future 3D Pattern Production Program development.

Dual detector system에서 Brain SPECT의 new reconstruction method의 연구 (The Study of New Reconstruction Method for Brain SPECT on Dual Detector System)

  • 이형진;김수미;이홍재;김진의;김현주
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.57-62
    • /
    • 2009
  • 목적 : 기존의 fan-beam을 이용한 triple detector system에서 parallel collimator를 이용한 dual detector system으로 변화에 있어 acquisition과 processing 부분에서 발생할 수 있는 여러 가지의 변수를 phantom과 volunteer test를 통하여 실험해 보았다. 1 day protocol brain spect를 위하여 parallel collimator에서만 적용되는 OSEM2D와 OSEM3D의 비교 분석을 중점으로 하였고, 모든 연구는 동등한 검사시간으로 fan-beam을 사용하였던 Triple gamma camera보다 parallel을 사용한 dual camera에서 보다 우수한 영상을 구현하고자 하는 목표를 지향하였다. 실험재료 및 방법 : Normal time scan과 short time scan을 실시하였고, collimator 변화에 따른 영상의 변화도 알아보았다. Jaczack performance phantom과 Body IEC phantom을 이용하여 SNR과 contrast를 평가해보았고 Hoffman 3D phantom의 실험을 거쳐 volunteer test를 실시하였다. 결과 : Normal time과 short time의 비교에서는 FLASH3D를 제외한 OSEM2D와 FBP는 분석방법으로 부적합하였다. LEAP는 resolution과 sharpness 등 전체적인 영상의 질이 기존의 fan-beam을 이용한 영상과 유사하였고, LEUHR은 감도의 저하로 1 day protocol을 적용하기 위한 scan time에는 부적합하였다. 재구성법의 비교에서는 Flash-3D를 이용한 결과들이 기존의 FBP와 OSEM-2D보다 월등히 정확함을 정성적으로 확인하였다. 결론 : OSEM3D 재구성법으로 Dual detector system에서의 1 day protocol brain SPECT 시 Fan-beam보다 sensitivity가 떨어지는 parallel collimator의 단점을 보완하면서 영상의 질 또한 de-noising과 scatter correction, resolution recovery 등의 효과를 얻을 수 있으므로 1 day protocol brain SPECT의 검사의 적용에 유용할 것으로 사료된다. 그러나 이러한 half-time method라 제공되는 다양한 프로그램의 임상적용에 대한 광범 위한 연구가 현실적으로 필요하며 향후 계속적인 연구가 기대되는 바이다.

  • PDF

F-18 FDG PET/CT로 재구성한 담관암의 3차원 영상 (Three Dimensional Volume Rendering Fusion Images Using F-18 FDG PET/CT in Evaluation of Cholangiocellular Carcinoma)

  • 공은정;조인호;천경아;원규장;이형우;은종열
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권1호
    • /
    • pp.81-81
    • /
    • 2008
  • A 69-year old male with cholangiocellular carcinoma (CCC) was assigned to our department for whole body PET/CT scan. $^{18}F$-FDG PET/CT images showed an intense hypermetabolic lobulating mass(SUVmax = 8.7 / size : 11.4 mm) in the right hepatic lobe with multiple metastatic lung nodules. We made three dimensional volume rendering fusion images by using advantage workstation 4.3 (GE health care) which provide quick anatomic overview and improve the planning process significantly.

볼륨 유방 여성의 흉부체형 분석에 관한 연구 (A Study on the Breast Shape Analysis of Big-breasted Women)

  • 한초희;이경화
    • 패션비즈니스
    • /
    • 제22권5호
    • /
    • pp.32-40
    • /
    • 2018
  • Big breasted women often experience dissatisfaction with ready-made brassieres, that do not account for individual breast types nor provide adequate cup sizes. This study was conducted to provide basic information on common breast shape and measurements of Korean big-breasted women, and to facilitate development of big-breasted women's bras with excellent fit and comfort. The study analyzed direct upper body measurements of 178 women in their 20's whith cup size C or bigger in the 5th, 6th and 7th Size Korea. In addition, 3D body scan data of women with bra size 75 and cup size C were re-collected and their breast types were examined. Average under-bust circumference of big-breasted women was 75 size in brassiere size. The average stature was 159.78 cm and the body weight was 60.33kg, indicating "overweight". Also, it was revealed that common breast types of big-breasted women, were hemispheric and cone types. The study can facilitate better understanding of breast shapes and sizes of standard big-breasted women, and will be useful as reference in selection of subjects in future studies.

Application of Lower Body Girth Change Analysis Using 3D Body Scanning to Pants Patterns

  • Choi, Sun-Yoon;Ashdown, Susan P.
    • 한국의류학회지
    • /
    • 제34권6호
    • /
    • pp.955-968
    • /
    • 2010
  • Three-dimensional body data has been used in many industry fields including the apparel industry. This research used data from a study of the changes in lower body girth measurements from a 3D scan study of 25 female subjects aged 18 to 24 in four postures; a standing posture, a $120^{\circ}$ knee bend posture, a one pace stepping posture, and a sitting posture with a $90^{\circ}$ knee bend. We used the information on the difference between standing and seated measurements to adjust ease values for pants patterns an evaluation of the appearance, and the comfort of the pants. Waist girth in the sitting posture increased 8% compared to a standing posture and the hip girth measurement increased 7%. A basic pants pattern (pants A) with 2.4cm ease at the waist and 2.6cm ease at the hip was developed and a pants pattern (pants B) was developed using the rates of lower body girth change with a 5.7cm ease (8% change) at the waist and 7cm ease (7% change) at the hip. The appearance assessment items of pants A in a standing posture were higher than pants B. On the other hand, most appearance assessment items of pants B in a sitting posture were higher than pants A, especially the ease of pants back waistline and the appearance of the whole back. Comfort assessment items of pants B in both standing and sitting postures were higher than the comfort assessment items for pants A, especially the location of pants waistline, the ease of pants at the waistline, and the ease at the abdomen. In order to find the best level of ease for better appearance and comfort in both standing and sitting postures, 20 pants were constructed with ease values at the waist and hip in increments of 1.1cm in the range between the ease values of pants A and pants B. A fit test was conducted to compare the average appearance and comfort ratings that identified the pants with the best ease values at the waist and hip. The highest total mean was achieved in the pants with a waist ease of 4.6cm and hip ease of 4.8cm.

피부길이변화를 고려한 3차원 다리보호대 모델링 (3D Modeling of Safety Leg Guards Considering Skin Deformation and shape)

  • 이효정;엄란이;이예진
    • 한국생활과학회지
    • /
    • 제24권4호
    • /
    • pp.555-569
    • /
    • 2015
  • During a design process of a protective equipment for sports activities, minimizing movement restrictions is important for enhancing its functions particularly for protection. This study presents a three-dimensional(3D) modeling methodology for designing baseball catcher's leg guards that will allow maximum possible performance, while providing necessary protection. 3D scanning is performed on three positions frequently used by a catcher during the course of a game by putting markings on the subject's legs at 3cm intervals : a standing, a half squat with knees bent to 90 degrees and 120 degrees of knee flexion. Using data obtained from the 3D scan, we analyzed the changes in skin length, radii of curvatures, and cross-sectional shapes, depending on the degree of knee flexion. The results of the analysis were used to decide an on the ideal segmentation of the leg guards by modeling posture. Knee flexions to 90 degrees and to $120^{\circ}$ induced lengthwise extensions than a standing. In particular, the vertical length from the center of the leg increases to a substantially higher degree when compared to those increased from the inner and the outer side of the leg. The degree of extension is varied by positions. Therefore, the leg guards are segmented at points where the rate of increase changed. It resulted in a three-part segmentation of the leg guards at the thigh, the knee, and the shin. Since the 120 degree knee-flexion posture can accommodate other positions as well, the related 3D data are used for modeling Leg Guard (A) with the loft method. At the same time, Leg Guard (B) was modeled with two-part segmentation without separating the knee and the shin as in existing products. A biomechanical analysis of the new design is performed by simulating a 3D dynamic analysis. The analysis revealed that the three-part type (A) leg guards required less energy from the human body than the two-part type (B).