• 제목/요약/키워드: 3D baffle

검색결과 50건 처리시간 0.035초

Conceptual Design of Cylindrical Hydrophone Arrays for Stabilization of Receiving Characteristics under Ocean Ambient Noise (해양 배경 소음 하의 수신 특성 안정화를 위한 원통형 하이드로폰 배열의 개념 설계)

  • Noh, Eunghwy;Lee, Hunki;Ohm, Won-Suk;Chang, Woosuk
    • The Journal of the Acoustical Society of Korea
    • /
    • 제34권3호
    • /
    • pp.200-209
    • /
    • 2015
  • An underwater sound surveillance system detects and tracks enemy ships in real-time using hydrophone arrays, in which seabed-mounted sensor arrays play a pivotal role. In this paper the conceptual design of seabed-mounted, cylindrical hydrophone arrays for use in shallow coastal waters is performed via finite element calculations. To stabilize the receiving characteristics under the ocean ambient noise, a technique for whitening the ambient noise spectrum using a metal baffle is proposed. Optimization of the array configuration is performed to achieve the directivity in the vertical and azimuthal directions. And the effects of the sonar dome shape and material on the structural vibration and sound scattering properties are studied. It is demonstrated that a robust hydrophone array, having a sensitivity deviation less than 4 dB over the frequency range of interest, can be obtained through the whitening of the ambient noise, the optimization of the array configuration, and the design of acoustically transparent sonar domes.

A successful Mustard operation for complete transposition of the great arteries combined with VSD, ASD, dextrocardia and PS: a report of one case (심실중격결손, 심방중격결손, 폐동맥협착과 우심증을 동반한 완전대혈관전위증의 치험)

  • 조중구
    • Journal of Chest Surgery
    • /
    • 제15권3호
    • /
    • pp.346-354
    • /
    • 1982
  • A Complete transposition of the great arteries combined with V.S.D, A.S.D, dextrocardia, and P.S is a rare congenital anomaly. The patient was a 10 year-old female whose complaints were frequent URI, exertional dyspnea, and cyanosis at rest since birth. Cheat X-ray films showed Dextrocardia ; situs inversus, moderate cardiomegaly, and Characteristic egg-shape heart shadow. E.K.G, Echocardiography, Cardiac Catheterization, and Angio-Cardiography were performed. Open heart Surgery was done under diagnosis of d-TGA, Dextrocardia, V.S.D, A.S.D, and P.S. At the time of Operation, Dextroeardia, T.G.A, Secndum type A.S.D, A.S.D, and P.S. At the time of Operation, Dextroeardia, T.G.A, Secndum type A.S.D. ($2.0{\times}2.0cm$. in diameter), V.S.D. type II ($1.5cm{\times}1.5cm$ in diameter), and pulmonary valvular stenosis were noted. Mustard operation using pericardial Baffle in the atrium for T.G.A. was perforsned. Teflon patch graft for closure of V.S.D. through tricuspid orifice and pulmonary Valvulotomy through pulmonary arteriotomy were performed. The post-op, low cardiac output Syndrome and dysrhythmicawere developed till Postoperative day #7, so that was controlled by inotropic and antiarrhythmic agents. After that, patient's conditions were Uneventful.

  • PDF

Numerical Analysis of the Turbulent Flow through an Oil-Grit Separator (3차원 모형을 이용한 유류-유사분리기내에서의 난류흐름해석)

  • Lee, Jin-Woo;Lee, Seung-Oh;NamGung, Don;Cho, Yong-Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.1254-1257
    • /
    • 2007
  • 본 연구에서는 유류-유사 분리기내에서 유체의 흐름거동을 상용 3차원 수치모형인 FLOW-3D를 이용하여 해석하였다. 유류-유사 분리기는 도심지의 우수로 인한 유출발생시 동반되는 이물질을 여과시키는 기능을 가진 지하구조물이다. 우수로 인한 유출이 발생하여 유류-유사 분리기내로 흘러들어오는 유입수는 3차원적 거동을 하고 다양한 흐름특성을 갖는다. 따라서, 분리기내에서의 흐름거동을 정확히 해석하는데 많은 어려움이 있다. 본 연구에서는 정류판(baffle)과 유류흡착기(oil skimmer)로 구성된 유류-유사 분리기에서의 유류와 유사를 포함하고 있는 유출수의 복잡한 거동을 해석하기 위해 수치모의를 실시하였다. 유류와 유사에 대한 포착률(oil and grit trap)은 유류-유사 분리기내에서 유체의 흐름거동과 관계된다. 따라서, 본 연구에서는 유류와 유사의 포착률을 향상시키기 위한 수치모의의 기초적인 단계로서 유류-유사 분리기내에서 유류흡착기(oil skimmer)를 설치한 경우와 설치하지 않은 경우에 대한 유체의 흐름거동을 FLOW-3D를 이용하여 3차원 수치모의를 실시하였다. 수치모의를 통해 유류흡착기의 유무에 따른 유류-유사 분리기내에서의 흐름거동을 알 수 있었으며, 유류흡착기를 설치한 경우엔 유류 흡착기에 의해 여과될 수 있는 유류와 유사에 대한 각각의 포획률이 높아짐을 알 수 있었다.

  • PDF

Comparison and Evaluation of Clothing Insulation of Newly-Developed Air-Filled Baffle Jackets and Down Padded Jackets (새롭게 개발된 겨울용 공기주입형 배플 패딩 재킷과 기존 방한 패딩 재킷들의 보온력 비교 평가)

  • Kwon, JuYoun;Kim, Siyeon;Baek, Yoon Jeong;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • 제23권2호
    • /
    • pp.261-272
    • /
    • 2021
  • The purpose of the present study was to evaluate the thermal insulation of air-filled winter jackets according to the amount of air-filler using a thermal manikin. The insulation of these jackets' was compared to a down padded jacket with an identical design and size. The amounts of air-filler were 100% (26,219 cm3), 70% (18,645 cm3), 50% (13,110 cm3), and 0% (0 cm3). The results showed that a clothing insulation (Icl) of 0%, 50%, 70%, and 100% air, and 100% down jackets was 0.208, 0.243, 0.207, 0.176, and 0.315 clo, respectively. In addition, the down jacket with waisttaped had a clothing insulation of 0.369 clo. However, the highest value of clothing insulation per clothing weight was the 50% air-filled jacket in all conditions. In terms of regional power consumption of the thermal manikin, the down jacket consumed less power for the shoulder and chest than the air-filled jackets. In conclusion, in order to maximize the thermal insulation of air-filled jackets, an optimal amount of air-filler, that is, an amount which does not compromise (break) the layer of inner air between the surface of manikin and the lining of the jacket, should be explored. Further studies on lining materials, end-closed design, and changes in thermal insulation under the conditions of strong wind or heavy snow are recommended.

Complete Transposition of the Great Arteries with Atrial Septal Defect -One Case Report- (대혈관 전위증 1예 보고)

  • 조건현
    • Journal of Chest Surgery
    • /
    • 제12권3호
    • /
    • pp.197-206
    • /
    • 1979
  • The most common abnormal relationship between the great arteries and ventricle is transposition of great arteries, among which complete D-transposition is a common and lethal malformation. Without appropriate treatment, the infant born with transposition of the great arteries rarely survives the first year of life. In contrast to the grim hopelessness of only a few years ago, modern aggressive palliative and corrective surgical interventions can provide such infants with considerable hope for adolescent and adult life. Up until this time, intraatrial baffle technique for re-direction of venous return, which was proposed by Mustard originally, has been successfully applied to infants and children in many foreign clinics with decreasing trend of the operative risk. In this report, we present one case of a 4 year-old girl having complete D-transposition of the great arteries with atrial septal defect, and reviewed the relevant literatures.

  • PDF

Structural Optimization of Water Treatment System for Initial Runoff (초기 유출수 처리를 위한 수처리 시설의 구조적 최적화)

  • Cho, Hun-Sik;Yeo, Chang-Guen;Lee, Seung-Oh;Song, Jae-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.668-672
    • /
    • 2009
  • 상대오염도가 높은 초기유출수에 대한 1차 처리의 화학적인 효율성 증대에 대한 연구는 많이 진행되어온 반면 동수역학적 분석에 관한 연구는 미흡한 실정이다. 본 연구에서는 수처리 시설에 대해서 수리모형 및 수치모의의 결과를 비교 분석하였다. 연구에 사용된 수처리 시설은 내부 격벽(baffle)의 배열에 변화를 주어 흐름제어를 유도하여 초기유출수의 처리 효율에 변화를 줄 수 있도록 시설을 고안하였다. 수리모형 및 수치모의 실험을 통해 구조물 내에 복잡한 난류흐름을 관찰하였고, 주입된 염수의 농도분포 양상을 시간변화에 따라 분석하였다. 수치모의를 위해서 3차원 수치모형 프로그램인 FLOW-3D를 사용하였으며 LES 난류모형과 질량생성(mass source)모형을 적용하여 수처리 시설 내에서의 동수역학적 거동분석 및 오염원(source)의 농도분포를 모의하였다. 실험 결과 수처리 시설의 3차원 난류흐름을 통해 오염원이 지체 및 확산되고 이에 따라 배출되는 농도가 현격하게 차이 냄을 확인하였다. 또한 추후 본 연구에서 제시된 바와 같이 다양한 내부구조에 대한 수치모의 결과를 분석하게 되면 초기 유출수 처리 효율을 증가시킬 수 있는 수처리 시설모형의 최적화 방안을 고려할 수 있을 것이다.

  • PDF

NUMERICAL ANALYSIS ON THE HEAT TRANSFER AND FLOW IN THE SHELL AND TUBE HEAT EXCHANGER (Shell & Tube 열교환기 Shell 측 열전달 및 유동에 대한 수치해석)

  • Lee, Sang-Hyuk;Lee, Myung-Sung;Hur, Nahm-Keon
    • Journal of computational fluids engineering
    • /
    • 제12권3호
    • /
    • pp.13-19
    • /
    • 2007
  • A numerical simulation on the heat transfer and flow field was carried out to improve the performance of the shell and tube heat exchanger. The steady incompressible 3-D Navier-Stokes solution is obtained with the actual operational condition and geometry of the heat exchanger. Based on this study, it is noted that the present geometry of the heat exchanger causes poor heat transfer since the air inside shell does not flow through the tube bundle, but around it. The enhancement of the heat transfer can be achieved by the variation of the design factor like the sealing strip located on the top/bottom and middle of the baffle, but it causes the increasement of the pressure drop. In this paper, the effects of the location and size of the sealing strips and flow rate through the heat exchanger on the heat transfer and pressure drop are studied.

A Numerical Analysis of the Baffled Silencer for the Noise Diminution of Tank Gun (전차포 소음 저감을 위한 배플형 소음기의 수치해석)

  • Ko, Sung-Ho;Lee, Dong-Su;Kang, Kuk-Jeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제31권3호
    • /
    • pp.217-224
    • /
    • 2007
  • A numerical analysis for a silencer with three baffles of 120mm tank gun has been performed. The Reynolds-Averaged Wavier-Stokes equations with Baldwin-Lomax turbulence model were employed to compute unsteady, compressible flow inside the tank gun and the silencer. An axisymmetric computational domain was constructed by using 12 multi block chimera grids. The resolution of flow field is observed by depicting calculated pressure and muzzle brake force. The peak blast pressure and noise through the silencer reduced approximately 99% and 41dB in comparison to the tank gun without the silencer at near filed.

Evaluation of the Effect of Sedimentation Basin Structure on Hydrodynamic Behavior Using CFD (II): The Effect of Trough (CFD를 이용한 침전지 구조가 수리거동에 미치는 영향 평가(II): 트라프의 영향 중심으로)

  • Park, No-Suk;Lim, Jae-Lim;Lee, Sun-Ju;Kwon, Soon-Bum;Min, Jin-Hui
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제19권6호
    • /
    • pp.758-766
    • /
    • 2005
  • This study was conducted to evaluate the effect of the transverse troughs on hydrodynamic behavior within the a certain full-scale sedimentation basin (flow rate/one basin; $10,000m^3/d$) using CFD simulation and ADV technique. In order to verify the CFD simulation, we measured the factual velocity at 36 points in the full-scale sedimentation basin, whose outlet structure is inadequate, with ADV technique. Both the CFD simulation and the ADV measurement results were in good accordance with each other. From the CFD simulation results of the existing basin, it was investigated that extreme upward flow occurs in the near of two transverse troughs. It was suspected that since the transverse troughs converted the open channel flow into the local closed pipe flow, the increased pressure in this local closed pipe flow region made the extreme upward flow. For solving this problems, it was suggested to modify transverse-typed launder into finger-typed launder and to install a longitudinal baffle in the center in this study. The CFD simulation results of all suggested amendments told us that the extreme upward flow, had occurred especially in the beneath of transverse troughs, was much less in the case of finger typed launder basin than that in the existing basin. Also, it was predicted that installing a longitudinal baffle made the fully developed flow which is more effective for sedimentation.

Performance Estimation and Test of Protype Pulse Tube Cryopump (맥동관형 크라이오펌프 시제품 성능예측과 평가)

  • In, Sang Ryul;Kang, Sang Paek
    • Journal of the Korean Vacuum Society
    • /
    • 제22권2호
    • /
    • pp.45-54
    • /
    • 2013
  • The cryopump of the pulse tube type has been developed successfully, and manufacturing of a prototype pump is finished under leading of Woosung Vacuum. The target pumping speed of the prototype pump is above 3,600 L/s for nitrogen with the intake port of 14 inches I.D (16 inches O.D). For designing optimally the pump structure including the charcoal array, thermal shield, and baffle, the pumping speed was simulated for various configurations through Monte Carlo method. Pumping performances of the protype cryopump manufactured on the basis of optimal design were conformed experimentally with a standard test system and procedures. The measured $N_2$ pumping speed of the prototype cryopump was 4,600 L/s which agreed well with simulated one and exceeded the target value.