DOI QR코드

DOI QR Code

Performance Estimation and Test of Protype Pulse Tube Cryopump

맥동관형 크라이오펌프 시제품 성능예측과 평가

  • 인상렬 (한국원자력연구원 핵융합공학기술개발센터) ;
  • 강상백 (우성진공(유))
  • Received : 2012.12.20
  • Accepted : 2013.02.19
  • Published : 2013.03.30

Abstract

The cryopump of the pulse tube type has been developed successfully, and manufacturing of a prototype pump is finished under leading of Woosung Vacuum. The target pumping speed of the prototype pump is above 3,600 L/s for nitrogen with the intake port of 14 inches I.D (16 inches O.D). For designing optimally the pump structure including the charcoal array, thermal shield, and baffle, the pumping speed was simulated for various configurations through Monte Carlo method. Pumping performances of the protype cryopump manufactured on the basis of optimal design were conformed experimentally with a standard test system and procedures. The measured $N_2$ pumping speed of the prototype cryopump was 4,600 L/s which agreed well with simulated one and exceeded the target value.

맥동관형 크라이오펌프 개발 사업 2단계를 맞아 우성진공(유)을 중심으로 상용화 시제품 개발이 성공적으로 끝나가고 있다. 최종 크라이오펌프 개발품은 흡기구 직경(내경) 16.5 (14) 인치에 질소 배기속도 3,600 L/s 이상을 목표로 하고 있다. 개발품의 성능확인을 위해 우선 몬테카를로 계산을 통해 배기속도를 예측하고 구조설계를 최적화했으며 이를 바탕으로 가공 조립된 크라이오펌프 시제품의 성능을 표준화된 장치에서 표준화된 절차를 통해 평가하여 설계 목표값과 비교했다. 시제품의 질소 배기속도는 4,600 L/s로 측정되어 설계값과 잘 일치하였으며 개발목표를 훨씬 상회하였다.

Keywords

References

  1. K. M. Welch, B. Andeen, J. E. de Rijke, C. A. Foster, M. H. Hablanian, R. C. Longsworth, W. E. Millikin, Y. T. Sasaki, and C. Tzemos, J. Vac. Sci. Technol. A. 17, 3081 (1999). https://doi.org/10.1116/1.582023
  2. Vacuum pumps acceptance specifications part 5- Refrigerator cooled cryopumps, PNEUROP PN5A SRCC/5 (1989).
  3. R. C. Longsworth and R. J. Webber, J. Vac. Sci. Technol. A. 9, 2766 (1991). https://doi.org/10.1116/1.577196
  4. C. Hayashi, Vacuum Tecnology (in Japanese) (Kyoritsu Shuppan, Tokyo, 1985), p25.
  5. S. R. In and M. Y. Park, J. Korean Vac. Soc. 12, 86 (2003).
  6. L. J. Peng and J. R. Morris, Carbon 50, 1394 (2012). https://doi.org/10.1016/j.carbon.2011.11.012
  7. R. A. Haefer, Cryopumping (Oxford, New York, 1989), p. 144.

Cited by

  1. Measurement of the Ar Recovery Time of a Cryopump and Analysis on the Ar Instability vol.22, pp.5, 2013, https://doi.org/10.5757/JKVS.2013.22.5.225