• Title/Summary/Keyword: 3D Volumes

Search Result 233, Processing Time 0.031 seconds

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

Hepatic Vessel Segmentation using Edge Detection (Edge Detection을 이용한 간 혈관 추출)

  • Seo, Jeong-Joo;Park, Jong-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.51-57
    • /
    • 2012
  • Hepatic vessel tree is the key structure for hepatic disease diagnosis and liver surgery planning. Especially, it is used to evaluate the donors' and recipients' liver for the LDLT(Living Donors Liver Transplantation) and estimate the volumes of left and right hepatic lobes for securing their life in the LDLT. In this study, we propose a method to apply canny edge detection that is not affected by noise to the liver images for automatic segmentation of hepatic vessels tree in contrast abdominal MDCT image. Using histograms and average pixel values of the various liver CT images, optimized parameters of the Canny algorithm are determined. It is more time-efficient to use the common parameters than to change parameters manually according to CT images. Candidates of hepatic vessels are extracted by threshold filtering around the detected the vessel edge. Finally, using a system which detects the true-negatives and the false-positives in horizontal and vertical direction, the true-negatives are added in candidate of hepatic vessels and the false-positives are removed. As a result of the process, the various hepatic vessel trees of patients are accurately reconstructed in 3D.

The Existence and Role of Ji-chong for Medical Exchange in Ancient Korea (지총(知聰)의 실존(實存)과 고대 한국 의학 교류(古代 韓國 醫學 交流)에 대한 역할(役割))

  • Kim, Jae-Hyo;Kim, Seong-Chul;Chung, Heon-Young;Kim, Ryong;Kwon, Oh-Sang;Kim, Kyung-Sik;Sohn, In-Chul
    • The Journal of Korean Medicine
    • /
    • v.28 no.3 s.71
    • /
    • pp.70-85
    • /
    • 2007
  • Objectives : Considering the indigenousness of Korean medicine, the historical record was first introduced in 1946 as follows; a Chinese person, Ji-chong (知聰), brought 164 volumes of medical books to Japan via Goguryeo (高句麗) in A.D. 562. Since this event happened, Korean Oriental Medicine has been derived from Traditional Chinese Medicine because ancient Korean Medicine originated and was developed in China. The purpose of this study was to investigate the existence and role of Ji-chong in the history of medical exchanges between ancient Korea and Japan. Methods : We studied Ji-chong through ancient and modern historical literatures such as Nihon Shoki (日本書紀), the record of $Shinsen-sh{\bar{o}}jiroku$ (新撰姓氏錄), Korean Medical History (韓國醫學史), Japanese Medical History (日本醫學史), Samguk Sagi (三國史記), etc. Results : We found indications of the existence of Ji-chong and the import of Chinese medical literature to the ancient Korean peninsula by examining domestic and foreign historical literature. Especially, he was closely related to historical assumptions about the Japanese conquest of Goguryeo in A.D. 562, although without objective historical evidence and described only in modern Japanese historical records and Korean Medical History. However, substantial medical exchange toward Japan was accomplished by Korean medicine of either Goguryeo, Baekje (百濟), or Silla (新羅) dynasty until the late A.D. 6 century. Conclusions : Based on the above investigation, the idea that Ji-chong carried medical literature via Goguryeo in A.D. 562 needs to be reconsidered and the role of Ji-chong as recorded in a variety of literature and databases should be amended., Korean Oriental Medicine has been derived from Traditional Chinese Medicine because ancient Korean Medicine originated and was developed in China. The purpose of this study was to investigate the existence and role of Ji-chong in the history of medical exchanges between ancient Korea and Japan. Methods : We studied Ji-chong through ancient and modern historical literatures such as Nihon Shoki (日本書紀), the record of Shinsen-$sh{\bar{o}}jiroku$ (新撰姓氏錄), Korean Medical History (韓國醫學史), Japanese Medical History (日本醫學士), Samguk Sagi (三國史記), etc. Results : We found indications of the existence of Ji-chong and the import of Chinese medical literature to the ancient Korean peninsula by examining domestic and foreign historical literature. Especially, he was closely related to historical assumptions about the Japanese conquest of Goguryeo in A.D. 562, although without objective historical evidence and described only in modern Japanese historical records and Korean Medical History. However, substantial medical exchange toward Japan was accomplished by Korean medicine of either Goguryeo, Baekje (百濟), or Silla (新羅) dynasty until the late A.D. 6 century. Conclusions : Based on the above investigation, the idea that Ji-chong carried medical literature via Goguryeo in A.D. 562 needs to be reconsidered and the role of Ji-chong as recorded in a variety of literature and databases should be amended.

  • PDF

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

The effects of PEP-1-FK506BP on dry eye disease in a rat model

  • Kim, Dae Won;Lee, Sung Ho;Ku, Sae Kwang;Lee, Ji Eun;Cha, Hyun Ju;Youn, Jong Kyu;Kwon, Hyeok Yil;Park, Jong Hoon;Park, Eun Young;Cho, Sung-Woo;Han, Kyu Hyung;Park, Jinseu;Eum, Won Sik;Choi, Soo Young
    • BMB Reports
    • /
    • v.48 no.3
    • /
    • pp.153-158
    • /
    • 2015
  • As FK506 binding proteins (FK506BPs) are known to play an important role in the regulation of a variety of biological processes related to cell survival, this study was designed to examined the protective effects of FK506 binding protein 12 (FK506BP) on low humidity air flow induced dry eye in a rat model using transduced PEP-1-FK506BP. After the topical application of PEP-1-FK506BP, tear volumes were markedly increased and significant prevention of cornea damage was observed compared with dry eye rats. Further, immunohistochemical analysis demonstrated that PEP-1-FK506BP markedly prevented damage to the cornea, the bulbar conjunctiva, and the palpebral conjunctiva epithelial lining compared with dry eye rats. In addition, caspase-3 and PARP expression levels were found to be decreased. These results demonstrated that topical application of PEP-1-FK506BP significantly ameliorates dry eye injury in an animal model. Thus, we suggest that PEP-1-FK506BP can be developed as a new ophthalmic drop to treat dry eye diseases.

A Study on Men's Costumes of the Parthian Period in Persia (페르시아 파르티아[Parthia]왕조 남자복식 연구)

  • YiChang Young-Soo
    • Journal of the Korean Society of Costume
    • /
    • v.56 no.4 s.103
    • /
    • pp.65-81
    • /
    • 2006
  • This is the study on the costumes of Parthian Period in Persia which had powerful influences on the Occidental and Western cultures in B.C 3 to A.D 3. With different types of Parthian costumes in each period, this study shows what types of costumes people used to wear and how they were co-related with its surrounding cultures. The ancient costumes of Korea had something to do with the elements of the Northern part at that time. To make an intensive study of Korean ancient costumes, these Parthian costumes which are known to those of northern nomadic tribes are studied to provide basis elements for study between the Korean styles and the exotic styles. The basic forms of the Parthian styles were jackets and trousers. They consisted of three kinds of jackets such as those to be adjusted In the front, tunics and coats. As for trousers, they were divided into three types such as those with horizontal pleats, round-side pleats and vertical pleats. 1) The jacket to be adjusted in the front was long enough to reach the hip and fit the body reasonably tight, and its neckline was shaped into V-type. It was a very popular style among the people of high and low classes. 2) The tunics had narrow sleeves. It was a one-piece pattern which reached the knees. It was settled with a belt on the waist. Its neckline was shaped into the round but its slit was not cleat. Its styles were into tight-fit and drapery ones. 3) The coats were almost similar to the jacket to be adjusted in the front with short length, but they were entirely long and open. They appeared later than the short jackets and the people of high class seemed to wear these styles. 4) 1'rousers with horizontal pleats - They had almost horizontal pleats on them, and they were a little tight. They seemed to be the early style in the Parthian period. 5) Trousers with round side-pleats - With saggy side pleats on them, these trousers had round pleats like a drapery style. This pattern was also considered Hellenistic elements shown in the Parthian costumes. The trousers consisted of the underdrawers and the leggings (called salwar or shalwar), which is thought to emphasize its functionality for its wearer to mount a horse with more ease. 6) Trousers with vertical pleats - With straight vertical pleats on them, these trousers had some volumes and bias decorations in the middle of them. These styles were thought to be worn by the ruling class of the Parthia from early to late period.

Surfactant Enhanced In-Situ Soil Flushing Pilot Test for the Soil and Groundwater Remediation in an Oil Contaminated Site (계면활성제 원위치 토양 세정법을 이용한 유류 오염 지역 토양.지하수 정화 실증 시험)

  • 이민희;정상용;최상일;강동환;김민철
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.77-86
    • /
    • 2002
  • Surfactant enhanced in-situ soil flushing was performed to remediate the soil and groundwater at an oil contaminated site, where had been used as a military vehicle repair area for 40 years. A section from the contaminated site (4.5 m $\times$ 4.5 m $\times$ 6.0 m) was selected for the research, which was composed of heterogeneous sandy and silt-sandy soils with average $K_d$ of 2.0$\times$$10^{-4}$cm/sec. Two percent of sorbitan monooleate (POE 20) and 0.07% of iso-prophyl alcohol were mixed for the surfactant solution and 3 pore volumes of surfactant solution were injected to remove oil from the contaminated section. Four injection wells and two extraction wells were built in the section to flush surfactant solution. Water samples taken from extraction wells and the storage tank were analyzed on a gas-chromatography (GC) for TPH concentration in the effluent with different time. Five pore volumes of solution were extracted while TPH concentration in soil and groundwater at the section were below the Waste Water Discharge Limit (WWDL). The effluent TPH concentration from wells with only water flushing was below 10 ppm. However, the effluent concentration using surfactant solution flushing increased to 1751 ppm, which was more than 170 times compared with the concentration with only water flushing. Total 18.5 kg of oil (TPH) was removed from the soil and groundwater at the section. The concentration of heavy metals in the effluent solution also increased with the increase of TPH concentration, suggesting that the surfactant enhanced in-situ flushing be available to remove not only oil but heavy metals from contaminated sites. The removal efficiency of surfactant enhanced in-situ flushing was investigated at the real contaminated site in Korea. Results suggest that in-situ soil flushing could be a successful process to remediate contaminated sites distributed in Korea.

A Study of Characteristics of MicroLion Liquid Ionization Chamber for 6 MV Photon Beam (6 MV 광자빔에 대한 MicroLion 액체이온함의 특성 연구)

  • Choi, Sang-Hyoun;Huh, Hyun-Do;Kim, Seong-Hoon;Ji, Young-Hoon;Kim, Kum-Bae;Kim, Woo-Chul;Kim, Hun-Jeong;Shin, Dong-Oh;Kim, Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.216-223
    • /
    • 2011
  • Recently PTW developed a MicroLion liquid ionization chamber which is water_equivalent and has a small sensitive volume of $0.002cm^3$. The aim of this work is to investigate such dosimetric characteristics as dose linearity, dose rate dependency, spatial resolution, and output factors of the chamber for the external radiotherapy photon beam. The results were compared to those of Semiflex chamber, Pinpoint chamber and Diode chamber with the sensitive volumes of $0.125cm^3$, $0.03cm^3$ and $0.0025cm^3$, respectively and evaluated to be suitable for small fields. This study was performed in the 6MV photon energy from a Varian 2300 C/D linac accelerator and the MP3 water phantom (PTW, Freiburg) was used. Penumbras in the varios field sizes ranged from $0.5{\times}0.5cm^2$ to $10{\times}10cm^2$ were used to evaluate the spatial resolution. Output factors were measured in the field sizes of $0.5{\times}0.5$ to $40{\times}40cm^2$. Readings of the chamber was linearly proportional to dose. Dose rate dependency was measured from 100 MU/min to 600 MU/min, showed a maximum difference of 5.0%, and outputs decreased with dose rates. The spatial resolutions determined with comparing profiles for the field sizes of $0.5{\times}0.5cm^2$ to $10{\times}10cm^2$ agreed between every detector except the Semiflex chamber to within 2%. Outputs of detectors were compared to that of Semiflex chamber and showed good agreements within 2% for every chamber. This study shows that MicroLion chamber characterized by a high signal-to-noise ratio and water equivalence could be suitable for the small field dosimetry.

Treatment of Human Thyroid Carcinoma Cells with the G47delta Oncolytic Herpes Simplex Virus

  • Wang, Jia-Ni;Xu, Li-Hua;Zeng, Wei-Gen;Hu, Pan;Rabkin, Samuel D.;Liu, Ren-Rin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1241-1245
    • /
    • 2015
  • Background: Thyroid carcinoma is the most common malignancy of the endocrine organs. Although the majority of thyroid cancer patients experience positive outcomes, anaplastic thyroid carcinoma is considered one of the most aggressive malignancies. Current therapeutic regimens do not confer a significant survival benefit, and new therapies are urgently needed. Oncolytic herpes simplex virus (oHSV) may represent a promising therapy for cancer. In the present study, we investigated the therapeutic effects of a third-generation HSV vector, $G47{\Delta}$, on various human thyroid carcinoma cell lines in vitro. Two subcutaneous (s.c.) models of anaplastic thyroid carcinoma were also established to evaluate the in vivo anti-tumor efficacy of $G47{\Delta}$. Materials and Methods: The human thyroid carcinoma cell line ARO, FRO, WRO, and KAT-5, were infected with $G47{\Delta}$ at different multiplicities of infection (MOIs) in vitro. The survival rates of infected cells were calculated each day. Two s.c. tumor models were established using ARO and FRO cells in Balb/c nude mice, which were intratumorally (i.t.) treated with either $G47{\Delta}$ or mock. Tumor volumes and mouse survival times were documented. Results: $G47{\Delta}$ was highly cytotoxic to different types of thyroid carcinomas. For ARO, FRO, and KAT-5, greater than 30% and 80% of cells were killed at MOI=0.01 and MOI=0.1, respectively on day 5. WRO cells displayed modest sensitivity to $G47{\Delta}$, with only 21% and 38% of cells killed. In the s.c. tumor model, both of the anaplastic thyroid carcinoma cell lines (ARO and FRO) were highly sensitive to $G47{\Delta}$; $G47{\Delta}$ significantly inhibited tumor growth and prolonged the survival of mice bearing s.c. ARO and FRO tumors. Conclusions: The oHSV $G47{\Delta}$ can effectively kill different types of human thyroid carcinomas in vitro. $G47{\Delta}$ significantly inhibited growth of anaplastic thyroid carcinoma in vivo and prolonged animal survival. Therefore, $G47{\Delta}$ may hold great promise for thyroid cancer patients.

Dosimetric Advantages of the Field-in-field Plan Compared with the Tangential Wedged Beams Plan for Whole-breast Irradiation (유방암 환자의 방사선치료에 있어서 순치료계획 세기변조방사선치료법과 쐐기접선조사기법의 선량측정 비교)

  • Kim, Suzy;Choi, Yunseok
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.199-204
    • /
    • 2014
  • The purpose of this study is to evaluate the dosimetric outcome of the field-in-field (FIF) plans compared with tangential wedged beams (TWB) plans for whole breast irradiation of breast cancer patients. Twenty patients with right-sided breast cancer and 10 patients with left-sided breast cancer were retrospectively enrolled in this study. We generated a FIF plan and a TWB plan for each patient to compare dosimetric outcomes. The dose the homogeneity index (HI), the conformity index (CI) and the uniformity index (UI) were defined and used for comparison of the dosimetric outcome of the planning target volume (PTV). To compare the dosimetric outcome of the organs at risk, the mean dose ($D_{mean}$) and the percentage of volumes receiving more than 10, 20 and 30 Gy of the ipsilateral lung and heart were used. The FIF plans had significantly lower HI (p=0.002), higher UI (p=0.000) and CI (p=0.000) than those of the TWB plans, which means that the FIF plans were better than the TWB plans in the dosimetric comparisons of the PTV. The $V10_{lung}$ ($17.1{\pm}7.1$ vs. $18.6{\pm}6.6%$, p=0.020) and $V30_{lung}$ ($10.3{\pm}5.1%$ vs. $10.7{\pm}5.2%$, p=0.000) were lower with the FIF plans compared with those of the TWB plans, with statistical significance. For the left-sided breast cancer patients, $D_{mean}$ of the heart ($2.6{\pm}1.3$ vs. $3.2{\pm}1.4$ Gy, p=0.000), $V20_{heart}$ ($3.4{\pm}2.6$ vs. $3.6{\pm}2.8%$, p=0.005) and $V30_{heart}$ ($2.6{\pm}2.3%$ vs. $2.9{\pm}2.4%$, p=0.004) were significantly lower for the FIF plans in comparison with those of the TWB plans. The FIF plans increased the dose homogeneity, conformity and uniformity of the target volume for the whole-breast irradiation compared with the TWB plans. Moreover, FIF plans reduced the doses to the ipsilateral lung and heart.