• Title/Summary/Keyword: 3D Volumes

Search Result 233, Processing Time 0.024 seconds

The Writing of 'HyangYakJipSungBang(鄕藥集成方)' and Medical Exchanges between Korea and China during the 15th Century (15세기 "향약집성방(鄕藥集成方)"의 편찬 과정에 드러난 한중(韓中) 의학교류)

  • Kang, Yeon-Seok
    • The Journal of Korean Medicine
    • /
    • v.29 no.4
    • /
    • pp.213-217
    • /
    • 2008
  • Since at least the late 12th century, medical herbs grown naturally or cultivated in Korea have been referred to as 'HyangYak'(鄕藥, $Xi\bar{a}ngY\grave{a}o$). Herbs from other countries are referred to as 'DangYak'(唐藥, $D\bar{a}ngY\grave{a}o$). Some senior historians claim medicines made solely from HyangYak are purely Korean, since they originated and were developed fully within Korea. However, these localized medicines became abundant as the result of exchanges between Korea and other countries. Originally published in 1433, 'HyangYakJipSungBang' is the authoritative result of earlier writings of medical books using HyangYak. Comprised of a total of 85 volumes, it was large in scale and divided into three main sections: 1) a detailed description of the 703 kinds of HyangYak, 2) explanations of the 10,706 different herbal formulae and 959 types of symptoms or diseases, and 3) descriptions of the 1,416 various acupuncture and moxibustion formulae. It's noted that 'HyangYakJipSungBang' was not written all at once. In the process of its writing, the number of formulae increased through medical exchanges between Korea and China during the 15th century.

  • PDF

Development of New Rapid Prototyping System Performing both Deposition and Machining (II) (적층과 절삭을 복합적으로 수행하는 새로운 개념의 판재 적층식 쾌속 시작 시스템의 개발(II) - 공정계획 시스템 -)

  • Heo, Jeong-Hun;Lee, Geon-U
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2235-2245
    • /
    • 2000
  • The necessity of using rapid prototyping(RP) for short-run manufacturing is continuously driving a development of a cost-effective technique that will produce completely-finished quality parts in a very short time. To meet these demands, the improvements in production speed, accuracy, materials, aid cost are crucial. Thus, a new hybrid-RP system performing both deposition and machining in a station is proposed. For the new hybrid RP process to maintain the same degree of process automation as in currently available processes like SLA or FDNI, a sophisticated process planning system is developed. In the process planner, CAD models(STEP AP203) are partitioned into 3D manufacturable volumes called 'Ueposition feature segment"(DFS) after machining features called "machining feature segmenf'(MFS) are extracted from the initial CAD model. Once MFS and DFS are identified, the process planner arranges them into a chain of processes and automatically generates machining information for each DFS and MFS. The goal of this paper is to present a framework for a process planning system for hybrid RP processes and to outline the geometric algorithms involved in developing such an environment.

Optimal Miniaturization of Desk-Top Computer by Thermal Design (열유동 해석을 이용한 컴퓨터 구조의 소형화 설계)

  • 박성관
    • Korean Journal of Computational Design and Engineering
    • /
    • v.4 no.4
    • /
    • pp.318-326
    • /
    • 1999
  • Recently, electronic systems including computers have been rapidly shrinking in size while at the same time the complexity and the capability of these systems continue to grow/sup [1]/. Thus, system volumes have decreased as system power has increased, resulting in dramatic increases in system heat density. The high temperature of the computer system is considered as the major reason for low performance and shortening life of the product. It is necessary to solve this problem due to the heat density increased and to develop the design skill of the computer cabinet according to miniaturization. M4500 desk-top computer was selected for analyzing the thermal management inside cabinet. The cabinet volume, the configuration of the heating devices, the size and location of air ventilation, and the fan selection have been investigated as the important parameters to find out an optimal cabinet design. The objectives of this project were to analyze which design parameters would affect cooling performance by thermal strategy, to design an optimal model, and to measure the temperatures of the main parts to confirm the effect of the thermal design. The temperatures of each part of the optimal model were compared with those of the existing model. As a result. the volume of this miniaturized model was about 16% smaller than that of M4500 without any change in operating performance.

  • PDF

Investigation of Narrow Pore Size Distribution on Carbon Dioxide Capture of Nanoporous Carbons

  • Meng, Long-Yue;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3749-3754
    • /
    • 2012
  • Nanoporous carbons with a high specific surface area were prepared directly from thermoplastic acrylic resin as carbon precursor and MgO powder as template by carbonization over the temperature range, $500-1000^{\circ}C$. The effect of the carbonization temperature on the pore structure and $CO_2$ adsorption capacity of the obtained porous carbon was examined. The textural properties and morphology of the porous carbon materials were analyzed by $N_2/-196^{\circ}C$ and $CO_2/0^{\circ}C$ adsorption/desorption isotherms, SEM and TEM. The $CO_2$ adsorption capacity of the prepared porous carbon was measured at $25^{\circ}C$ and 1 bar and 30 bar. The specific surface area increased from 237 to $1251m^2/g$, and the total pore volumes increased from 0.242 to $0.763cm^3/g$ with increasing the carbonization temperature. The carbonization temperature acts mainly by generating large narrow micropores and mesopores with an average pore size dependent on the level of carbonization of the MgO-templated nanoporous carbons. The results showed that the MgO-templated nanoporous carbons at $900^{\circ}C$ exhibited the best $CO_2$ adsorption value of 194 mg/g at 1 bar.

A Study on the Pulse Conditions and Symptoms of Diseases Related with Pathogenic Factor of Deficiency Type, Excess Type, Zei Pathogenic Factor and Indistinct Pathogenic Factor of the Five Viscera in the Third Volume in the Maek Kyoung(脈經) III (맥경(脈經) 권삼(卷三) 오장(五臟)의 허(虛).실(實).적(賊).미사(微邪)에 따른 맥상(脈象)과 병증(病證)에 대(對)한 연구(硏究) III)

  • Sung, Back-Man;Park, Kyung
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.57-71
    • /
    • 2005
  • Background and purpose: Maek Kyoung(脈經) is a book written, compiled, and edited by Wang Hui circa 3 A.D. This book is the first technical book devoted to the diagnostics. These are very important data but never make a special study and translate. so I hope this treatise can be great help to understand diagnosis study. Methods: Maek Kyoung(脈經) consists of ten volumes, and the third volume consists of the five chapters, including inter-generation and inter-restriction of the five viscera and the six entrails and prognosis of diseases. This treatise is made up of principal, notes, study and conclusion, we tried to make a translation faithful to the original. Results and Conclusion: Chapter 5 refers to three things. The first is relation between kidney and urinary bladder, the second is ordinary and extraordinary pulse condition of kidney, and the third is how to treat diseases related to kidney.

  • PDF

A Preliminary Evaluation on CO2 Storage Capacity of the Southwestern Part of Ulleung Basin, Offshore, East Sea (동해 울릉분지 남서 주변부의 이산화탄소 저장 용량 예비 평가)

  • Kim, Yu-Lee;Lee, Keum-Suk;Jo, So-Hyun;Kim, Min-Jun;Kim, Jong-Soo;Park, Myong-Ho
    • Economic and Environmental Geology
    • /
    • v.45 no.1
    • /
    • pp.41-48
    • /
    • 2012
  • A theoretical $CO_2$ storage capacity is estimated on the southwestern continental shelf margin of Ulleung Basin, offshore Korea using 2D/3D multi-channel seismic and wellbore data acquired in the area over the two decades since the late 1980s. For the first time in Korea, the present study applies an efficiency factor to the capacity calculation, together with the other required parameters. For possible $CO_2$ storage volume estimation of the study area, we interpreted the seismic data in the Gorae area from 800 m to 3,000 m below the seafloor integrated with the well data, and identified five different seismic units; the limited depth interval is considered because of fluid state of $CO_2$ and tightness of the formation. The total volumes of each seismic unit were converted with a time-depth relation inferred from the checkshot surveys before the other required parameters including porosity and density were applied to compute the potential storage capacity. The accumulated possible storage volume from the five depositional units in the study area is estimated to be approximately 5,100 Mton ($P_{50}$). The approaches made in this study will be applied to the rest area of the basin and other continental shelves (i.e., Yellow Sea and northern part of East China Sea) in the next phase.

A cosmic ray muons tomography system with triangular bar plastic scintillator detectors and improved 3D image reconstruction algorithm: A simulation study

  • Yanwei Zhao;Xujia Luo;Kemian Qin;Guorui Liu;Daiyuan Chen;R.S. Augusto;Weixiong Zhang;Xiaogang Luo;Chunxian Liu;Juntao Liu;Zhiyi Liu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.681-689
    • /
    • 2023
  • Purpose: Muons are characterized by a strong penetrating ability and can travel through thousands of meters of rock, making them ideal to image large volumes and substances typically impenetrable to, for example, electrons and photons. The feasibility of 3D image reconstruction and material identification based on a cosmic ray muons tomography (MT) system with triangular bar plastic scintillator detectors has been verified in this paper. Our prototype shows potential application value and the authors wish to apply this prototype system to 3D imaging. In addition, an MT experiment with the same detector system is also in progress. Methods: A simulation based on GEANT4 was developed to study cosmic ray muons' physical processes and motion trails. The yield and transportation of optical photons scintillated in each triangular bar of the detector system were reproduced. An image reconstruction algorithm and correction method based on muon scattering, which differs from the conventional PoCA algorithm, has been developed based on simulation data and verified by experimental data. Results: According to the simulation result, the detector system's position resolution is below 1 ~ mm in simulation and 2 mm in the experiment. A relatively legible 3D image of lead bricks in size of 20 cm × 5 cm × 10 cm used our inversion algorithm can be presented below 1× 104 effective events, which takes 16 h of acquisition time experimentally. Conclusion: The proposed method is a potential candidate to monitor the cosmic ray MT accurately. Monte Carlo simulations have been performed to discuss the application of the detector and the simulation results have indicated that the detector can be used in cosmic ray MT. The cosmic ray MT experiment is currently underway. Furthermore, the proposal also has the potential to scan the earth, buildings, and other structures of interest including for instance computerized imaging in an archaeological framework.

Radiographic evaluation of the symphysis menti as a donor site for an autologous bone graft in pre-implant surgery

  • Bari, Roberto Di;Coronelli, Roberto;Cicconetti, Andrea
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.135-143
    • /
    • 2013
  • Purpose: This study was performed to obtain a quantitative evaluation of the cortical and cancellous bone graft harvestable from the mental and canine regions, and to evaluate the cortical vestibular thickness. Materials and Methods: This study collected cone-beam computed tomographic (CBCT) images of 100 Italian patients. The limits of the mental region were established: 5 mm in front of the medial margin of each mental foramen, 5 mm under the apex of each tooth present, and above the inferior mandibular cortex. Cortical and cancellous bone volumes were evaluated using SimPlant software (SimPlant 3-D Pro, Materialize, Leuven, Belgium) tools. In addition, the cortical vestibular thickness (minimal and maximal values) was evaluated in 3 cross-sections corresponding to the right canine tooth (3R), the median section (M), and the left canine tooth (3L). Results: The cortical volume was $0.71{\pm}0.23mL$ (0.27-1.96 mL) and the cancellous volume was $2.16{\pm}0.76mL$ (0.86-6.28 mL). The minimal cortical vestibular thickness was $1.54{\pm}0.41mm$ (0.61-3.25 mm), and the maximal cortical vestibular thickness was $3.14{\pm}0.75mm$ (1.01-5.83 mm). Conclusion: The use of the imaging software allowed a patient-specific assessment of mental and canine region bone availability. The proposed evaluation method might help the surgeon in the selection of the donor site by the comparison between bone availability in the donor site and the reconstructive exigency of the recipient site.

Magnetite Nanoparticles Containing Nanoporous Carbon for the Adsorption of Ibuprofen (마그네타이트 나노입자를 포함한 탄소나노세공체 합성과 아이부프로펜 흡착거동)

  • Park, Sung Soo;Ha, Chang-Sik
    • Journal of Adhesion and Interface
    • /
    • v.14 no.2
    • /
    • pp.82-87
    • /
    • 2013
  • Preliminary studies on the synthesis of magnetic nanoparticles including nanoporous carbon materials have been done via a direct carbonization process from resol, ferric nitrate and triblock copolymer F127. The results show that the nanoporous magnetite/carbon ($Fe_3O_4$/carbon) with a low $Fe_3O_4$ content (1 wt%) possesses an ordered 2-D hexagonal (p6mm) structure, uniform nanopores (3.6 nm), high surface areas (up to 635 $m^2/g$) and pore volumes (up to 0.48 $cm^3/g$). Magnetite nanoparticles with a small particle size (10.2 nm) were confined in the matrix of amorphous carbon frameworks with superparamagnetic property (7.7 emu/g). The nanoporous magnetite/carbon showed maximum adsorption amount (995 mg/g) of ibuprofen after 24 h at room temperature. The nanoporous magnetite/carbon was separated from solution easily by using a magnet. The nanoporous magnetite/carbon material is a good adsorbent for hydrophobic organic drug molecules, i.e. ibuprofen.

Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom (간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증)

  • Kim, Jin-Sung;Cho, June-Sik;Shin, Kyung-Sook;Kim, Jin-Hwan;Jeon, Ho-Sang;Cho, Gyu-Seong
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

  • PDF