• Title/Summary/Keyword: 3D Short

Search Result 1,503, Processing Time 0.031 seconds

Effects of Lactobacillus plantarum CIB 001 on Lipid Metabolism of Hypercholesterolemic Rats (김치에서 분리한 Lactobacillus plantarum CIB 001 급여가 고콜레스테롤혈증 흰쥐의 지질대사에 미치는 영향)

  • Cha, Sang-Do;Yu, Ji-Won;Kim, Tae-Woon;Cho, Ho-Seong;Lee, Dong-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.324-330
    • /
    • 2012
  • The aim of the present study was to assess the anti-hypercholesterolemic effect of bile salt hydrolase-producing Lactobacillus plantarum CIB 001 (KCTC 11717 bp) in rats fed a high-cholesterol diet. Four treatment groups of rats (n=5) were fed experimental diets: a normal diet (ND), a ND plus L. plantarum CIB 001(NDL) at $5.0-7.5{\times}10^9$ colony forming unit (CFU)/day, a high-cholesterol diet (HCD), as well as a HCD plus L. plantarum CIB 001 (HCDL) at $5.0-7.5{\times}10^9$ CFU/day for 6 weeks. Compared with the HCD group, the HCDL group demonstrated a decrease in serum triglyceride (p<0.05), total cholesterol (p<0.05), and the corresponding HDL-cholesterol concentration increased at a rate of 40% (p<0.05). The HCDL group also induced a decrease in liver inflammation and steatosis. The present results suggest that supplementation of L. plantarum CIB 001 can have short-term (6 weeks) effects on blood lipids and liver injury, as well as on the atherogenic index and cardiac risk factors.

Studies on Packaging of Chillies (Capsicum annum) in Flexible Films, and Their Laminates (유연포장재료(柔軟包裝材料)를 이용(利用)한 고추 포장(包裝)에 관(關)한 연구(硏究))

  • Chang, Kyu-Seob;Kim, Ze-Uook
    • Applied Biological Chemistry
    • /
    • v.19 no.3
    • /
    • pp.145-154
    • /
    • 1976
  • Studies have been carried out to design a suitable consumer size package from flexible packaging material to hold 100 grams of Chilli powder and 250 grams of whole chilli which are moisture and color sensitive. 1. Sorption characteristics of the chilli powder has revealed that moisture sorption is rapid above 55 per cent R.H., and the product is fairly hygroscopic. Further, an equilibrium moisture content of about 15 per cent at 70 per cent R.H., appears to be critical from the point of microbial spoilage of chilli powder. 2. Studies on the colour (Capsanthin) changes of chilli powder equilibriated to different moisture content, have revealed that colour changes during storage is greatly influenced by the moisture content and temperature decreases the capsanthin content of chilli during storage. 3. From the studies, it can be inferred that the sunlight exhibits pronounced effect in bleaching of colour and brings about maximum discolouration of the red pigment in chilli. 4. From the packaging and storage studies of chilli powder in different flexible films, it can be concluded that for long-term storage, the aluminium foil laminate is unique in offering maximum protection from various physico-chemical changes. For short-term storage and for fairly good moisture and colour protection, amber or black polyethylene, high-density polyethylene and Saran/Cello/Saran poly laminate pouches appear to be suitable alternatives.

  • PDF

Analysis of Conformability for Cadastral Control Network Using GPS Satellite Surveying (GPS에 의한 지적삼각망의 정합성 분석)

  • Kang, Joon-Mook;Yoon, Hee-Cheon;Kim, Hong-Jin
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.2 no.1 s.3
    • /
    • pp.121-129
    • /
    • 1994
  • A number of existing cadastral control stations have been destroyed and shifted by a long lapse of time and careless management. Also, results of them are partly poor owing to dependence on conventional survey method. Because of these, it is very difficult in use of results. Hereupon, correction of cadastral results is necessary in level of government. But it is very consumable to check and adjust results with existing equipments and related techniques only. It is required that this problem can be resolved efficiently. This study analyzed the conformability for cadastral control network to GPS, GPS, which determine precise 3-D coordinates on a short time, to positioning of cadastral stations. We chose DaeJon city for the test area of this study and analyzed the precision of network composed of sixteen cadastral control stations. We made comparision the old result and the new outcome which obtained from coordinate transformation method and horizontal network adjustment method. As a result of this, we detected the blunder of cadastral stations. Furthermore, we suggested effective network type according to precision analysis of GPS observation network. Therefore, there is no doubt that GPS surveying can be applied to checking and adjustment of cadastral control network. Hereafter, it is expected that the practical use of GPS is advanced in a field of cadastration.

  • PDF

A Linear Change of Leakage Current and Insulation Resistance of 22 kV Cables (22 kV 케이블의 누설전류 및 절연저항의 선형적 변화)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.169-173
    • /
    • 2015
  • This study is to predict the life exponent by measuring, over 7 years, the insulation resistance of high-voltage cables in 22 kV operation for 13 years. We found out the lifetime index in order to determine the time-dependent trend of deteriorating performance of power cables. The insulation resistances decreased according to elapsed time. We found that: the initial measurements of the cable systems were in agreement with the deterioration properties of the Arrhenius Law. By analyzing the life curve of the cable system, we also verified that the value of the life exponent (n) in the v-t characteristics defined by Weibull distribution has values from 10 to 11. When designing the cable system, the initial value of life exponent was chosen as 9 without any grounding. We have verified that the theoretical grounding based on the design safety of n=9 was actually the best one available. In the short term, we apply our research result to the diagnosis and evaluation of the power cables. In the long run, however, we plan to reduce the cost of the installation and management of cable systems in operation at power stations.

A Study on customer satisfaction with self technological - based product (정보화시대의 무인자동화 제품디자인이 고객만족에 미치는 영향에 관한 연구 - 중요사건기법(critical incident technique)을 중심으로 -)

  • 박종찬
    • Archives of design research
    • /
    • v.17 no.3
    • /
    • pp.283-292
    • /
    • 2004
  • Today's fast-paced world is becoming increasingly characterized by technology-facilitated transactions. Growing numbers of customers interact with technology to create service outcomes instead of interacting with a service firm employee. Self-service technologies provide technological interfaces that enable customers to produce a service independent of direct service employee involvement. To investigate on the customer satisfaction with self-technological based product design in Subway. I used the critical incident technique developed by Flanagan(1954) with quantitative measures of attributions. In this research, it results that customers are considered more important the value of technological-function and easy to use than the aspect of automated machine. It is likely that the technological aspect of many self-service options has a unique influence on customer perceptions of self-service encounters. Also, Research has shown that customer's needs are defined as situations in which external environmental factors add a sense of urgency to the transaction and saved time. On the other hand, customers realize that their favorable image of self-technological based product follows as ; first, customers prefer to the simple & modern image on the aspect of product design, secondly, customers prefer to the hitech-functional image to do its job fast in a short time by automated technology on the aspect of functional service, thirdly, customers prefer to the comfortable and sanitary image to be suitable for the underground circumstance.

  • PDF

Relief of Chronic Posterior Neck Pain Depending on the Type of Forest Therapy: Comparison of the Therapeutic Effect of Forest Bathing Alone Versus Forest Bathing With Exercise

  • Kang, Boram;Kim, Taikon;Kim, Mi Jung;Lee, Kyu Hoon;Choi, Seungyoung;Lee, Dong Hun;Kim, Hyo Ryoung;MA, Byol Jun;Park, Seen Young;Lee, Sung Jae;Park, Si-Bog
    • Annals of Rehabilitation Medicine
    • /
    • v.39 no.6
    • /
    • pp.957-963
    • /
    • 2015
  • Objective To compare the pain-reducing effect of forest bathing alone versus forest bathing in combination with stretching and strengthening exercises in patients with chronic posterior neck pain. Methods Sixty-four subjects with posterior neck pain that had lasted more than 3 months were enrolled. They were randomly divided into a forest bathing alone (FBA) group and a forest bathing with exercise (FBE) group; each group included 32 subjects. All subjects from both groups walked every morning in the forest for about 2 hours for 5 days. In the afternoon, the FBE group did a stretching and strengthening exercise for about 4 hours; the FBA group had free time in the woods. Visual analog scale (VAS) on one day, VAS over the previous week, neck disability index (NDI), EuroQol 5D-3L VAS (EQ VAS) and index (EQ index), McGill pain questionnaire (MPQ), the number of trigger points in the posterior neck region (TRPs), and the range of motion of the cervical spine were evaluated on the first and last day of the program and compared between the two groups. Results The number of TRPs were significantly reduced in the FBE group compared with the FBA group (p=0.013). However, the other scales showed no significant difference between the two groups. Conclusion When patients with chronic posterior neck pain underwent a short-term forest bathing (less than 7 days) program, FBE was more effective in the reduction of the number of TRPs than FBA. However, all other pain measurement scales we evaluated showed no statistically significant difference between the two protocols.

Finding Optimal Installation Depth of Strong Motion Seismometers for Seismic Observation (지진 관측을 위한 최적 설치심도 조사 방법 연구)

  • Seokho Jeong;Doyoon Lim ;Eui-Hong Hwang;Jae-Kwang Ahn
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.2
    • /
    • pp.31-40
    • /
    • 2023
  • We installed temporary strong motion seismometers at the ground surface, 1 m, 2 m, and 9 m at an existing seismic station that houses permanent seismometers installed at 20 m and 100 m, to investigate the influence of installation depth on the recorded ambient and anthropogenic noise level and the characteristics of earthquake signals. Analysis of the ambient noise shows that anthropogenic noise dominates where vibration period T < 1 s at the studied site, whereas wind speed appears to be strongly correlated with the noise level at T > 1 s. Frequency-wavenumber analysis of 2D seismometer array suggests that ambient noise in short periods are predominantly body waves, rather than surface waves. The level of ambient noise was low at 9 m and 20 m, but strong amplification of noise level at T < 0.1 s was observed at the shallow seismometers. Both the active-source test result and the recorded earthquake data demonstrated that the signal level is decreased with the increase of depth. Our result also shows that recorded motions at the ground and 1 m are strongly amplified at 20 Hz (T = 0.05 s), likely due to the resonance of the 3 m thick soil layer. This study demonstrates that analysis of ambient and active-source vibration may help find optimal installation depth of strong motion seismometers. We expect that further research considering various noise environments and geological conditions will be helpful in establishing a guideline for optimal installation of strong motion seismometers.

Effect of Shading on Japanese Apricot Fruit Yield and Quality (차광이 매실의 수량 및 품질에 미치는 영향)

  • Jung Gun Cho;Sung Ku Kang;Seung Heui Kim;Sang Kun Park;Yong Bum Kwack
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.25 no.4
    • /
    • pp.84-89
    • /
    • 2024
  • Light is an important component among which plays a crucial role in determining the production and quality of fruit trees. Since the disturbance of light directly leads to reduced photosynthetic efficiency, their damage can be increased especially in fruit trees such as Japanese apricots with a short growing time. In this study, we investigated how the effects of shading condition can affect the production and quality of Japanese apricots according to increased damages by light disturbance in the main orchard complex. The average photosynthetically active radiation (PAR) level in Japanese apricots was rapidly dropped as the shading time was increased compared to the control (304 μmol/m2/s) and the PAR level decreased to 142 μmol/m2/s after shaded for eight hours. The maximum photosynthetic efficiency, with a PAR value of 900 to 1,000 μmol/m2/s, corresponds to the time period without shading and the time period with 2 hours of shading, and these times range from 11 a.m. to 3 p.m. And the time period for shading for 4 hours was from 1:00 p.m. to 2:00 p.m., and under conditions of shading for 6 and 8 hours, the effect was a low amount of light. There was no difference in the weight of Japanese apricots during 2 hours shading time, however, it was significantly reduced as shading time were increased. The difference of the acid content and L/D ratio was not significant on shading time, but the SSC was decreased as times going on. In conclusion, our results indicate that the shading for more than 2 hours make negative effects to decrease the weight and SSC and the yield and affects directly to drop in fruit quality.

The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy (양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증)

  • Hong, Gun-Chul;Jang, Joon-Yung;Park, Se-Joon;Cha, Eun-Sun;Lee, Hyuk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2017
  • Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 mm) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of $0^{\circ}$. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 mm in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 mm) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 mm) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 mm sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 mm and 22 mm, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 mm, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

  • PDF

Investigation of Intertidal Zone using TerraSAR-X (TerraSAR-X를 이용한 조간대 관측)

  • Park, Jeong-Won;Lee, Yoon-Kyung;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.4
    • /
    • pp.383-389
    • /
    • 2009
  • The main objective of the research is a feasibility study on the intertidal zone using a X-band radar satellite, TerraSAR-X. The TerraSAR-X data have been acquired in the west coast of Korea where large tidal flats, Ganghwa and Yeongjong tidal flats, are developed. Investigations include: 1) waterline and backscattering characteristics of the high resolution X-band images in tidal flats; 2) polarimetric signature of halophytes (or salt marsh plants), specifically Suaeda japonica; and 3) phase and coherence of interferometric pairs. Waterlines from TerraSAR-X data satisfy the requirement of horizontal accuracy of 60 m that corresponds to 20 cm in average height difference while current other spaceborne SAR systems could not meet the requirement. HH-polarization was the best for extraction of waterline, and its geometric position is reliable due to the short wavelength and accurate orbit control of the TerraSAR-X. A halophyte or salt marsh plant, Suaeda japonica, is an indicator of local sea level change. From X-band ground radar measurements, a dual polarization of VV/VH-pol. is anticipated to be the best for detection of the plant with about 9 dB difference at 35 degree incidence angle. However, TerraSAR-X HH/TV dual polarization was turned to be more effective for salt marsh monitoring. The HH-HV value was the maximum of about 7.9 dB at 31.6 degree incidence angle, which is fairly consistent with the results of X-band ground radar measurement. The boundary of salt marsh is effectively traceable specifically by TerraSAR-X cross-polarization data. While interferometric phase is not coherent within normal tidal flat, areas of salt marsh where the landization is preceded show coherent interferometric phases regardless of seasons or tide conditions. Although TerraSAR-X interferometry may not be effective to directly measure height or changes in tidal flat surface, TanDEM-X or other future X-band SAR tandem missions within one-day interval would be useful for mapping tidal flat topography.