• Title/Summary/Keyword: 3D Short

Search Result 1,510, Processing Time 0.031 seconds

Effects of Artificial Leg Length Discrepancies on the Dynamic Joint Angles of the Hip, Knee, and Ankle During Gait

  • Kim, Yong-Wook;Jo, Seung-Yeon;Byeon, Yeoung-In;Kwon, Ji-Ho;Im, Seok-Hee;Cheon, Su-Hyeon;Kim, Eun-Joo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.1
    • /
    • pp.53-61
    • /
    • 2019
  • PURPOSE: This study examined the dynamic range of motion (ROM) of the hip, knee, and ankle joint when wearing different shoe sole lifts, as well as the limb asymmetry of the range according to the leg length discrepancy (LLD) during normal speed walking. METHODS: The participants were 40 healthy adults. A motion analysis system was used to collect kinematic ROM data. The participants had 40 markers attached to their lower extremities and were asked to walk on a 6 m walkway, under three different shoe lift conditions (without an insole, 1 cm insole, and 2 cm insole). Visual3D professional software was used to coordinate kinematic ROM data. RESULTS: Most of the ROM variables of the short limbs were similar under each insole lift condition (p>.05). In contrast, when wearing a shoe with a 2 cm insole lift, the long limbs showed significant increases in flexion and extension of the knee joint as well as; plantarflexion, dorsiflexion, pronation, eversion, and inversion of the ankle joint (p<.05). Of the shoes with the insole lifts, significant differences in all ROM variables were observed between the left and right knees, except for the knee internal rotation (p<.05). CONCLUSION: As the insole lift was increased, more ROM differences were observed between the left and right limbs, and the asymmetry of the bilateral lower limbs increased. Therefore, appropriate interventions for LLD are needed because an artificial mild LLD of less than 2.0 cm could lead to a range of musculoskeletal problems of the lower extremities, such as knee and ankle osteoarthritis.

Industrial analysis according to lithography characteristics of digital micromirror device and polygon scanner (Digital Micromirror Device와 Polygon scanner의 Lithography 특성에 따른 산업적 분석)

  • Kim, Ji-Hun;Park, Kyu-Bag;Park, Jung-Rae;Ko, Kang-Ho;Lee, Jeong-woo;Lim, Dong-Wook
    • Design & Manufacturing
    • /
    • v.15 no.4
    • /
    • pp.65-71
    • /
    • 2021
  • In the early days of laser invention, it was simply used as a measuring tool, but as lasers became more common, they became an indispensable processing tool in the industry. Short-wavelength lasers are used to make patterns on wafers used in semiconductors depending on the wavelength, such as CO2 laser, YAG laser, green laser, and UV laser. At first, the hole of the PCB board mainly used for electronic parts was not thin and the hole size was large, so a mechanical drill was used. However, in order to realize product miniaturization and high integration, small hole processing lasers have become essential, and pattern exposure for small hole sizes has become essential. This paper intends to analyze the characteristics through patterns by exposing the PCB substrate through DMD and polygon scanner, which are different optical systems. Since the optical systems are different, the size of the patterns was made the same, and exposure was performed under the optimal conditions for each system. Pattern characteristics were analyzed through a 3D profiler. As a result of the analysis, there was no significant difference in line width between the two systems. However, it was confirmed that dmd had better pattern precision and polygon scanner had better productivity.

Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer

  • Park, Jinsoo;Jung, Bongsu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.129-143
    • /
    • 2022
  • Background: Patient-controlled analgesia (PCA) has been widely used as an effective medical treatment for pain and for postoperative analgesia. However, improper dose errors in intravenous (IV) administration of narcotic analgesics from a PCA infusion pump can cause patient harm. Furthermore, opioid overdose is considered one of the highest risk factors for patients receiving pain medications. Therefore, accurate delivery of opioid analgesics is a critical function of PCA infusion pumps. Methods: We designed a microbalance method that consisted of a closed acrylic chamber containing a layer and an oil layer with an electronic balance. A commercially available infusion analyzer (IDA-5, Fluke Co., Everett, WA, USA) was used to measure the accuracy of the infusion flow rate from a commercially available smart PCA infusion pump (PS-1000, UNIMEDICS, Co., Ltd., Seoul, Korea) and compared with the results of the microbalance method. We evaluated the uncertainty of the flow rate measurement using the ISO guide (GUM:1995 part3). The battery life, delay time of the occlusion alarm, and bolus function of the PCA pump were also tested. Results: The microbalance method was good in the short-term 2 h measurement, and IDA-5 was good in the long-term 24 h measurement. The two measurement systems can complement each other in the case of the measurement time. Regarding battery performance, PS-1000 lasted approximately 5 days in a 1 ml/hr flow rate condition without recharging the battery. The occlusion pressure alarm delays of PS-1000 satisfied the conventional alarm threshold of occlusion pressure (300-800 mmHg). Average accuracy bolus volume was measured as 63%, 95%, and 98.5% with 0.1 ml, 1 ml, and 2 ml bolus volume presets, respectively. A 1 ml/hr flow rate measurement was evaluated as 2.08% of expanded uncertainty, with a 95% confidence level. Conclusion: PS-1000 showed a flow accuracy to be within the infusion pump standard, which is ± 5% of flow accuracy. Occlusion alarm of PS-1000 was quickly transmitted, resulting in better safety for patients receiving IV infusion of opioids. PS-1000 is sufficient for a portable smart PCA infusion pump.

Development of GK2A Convective Initiation Algorithm for Localized Torrential Rainfall Monitoring (국지성 집중호우 감시를 위한 천리안위성 2A호 대류운 전조 탐지 알고리즘 개발)

  • Park, Hye-In;Chung, Sung-Rae;Park, Ki-Hong;Moon, Jae-In
    • Atmosphere
    • /
    • v.31 no.5
    • /
    • pp.489-510
    • /
    • 2021
  • In this paper, we propose an algorithm for detecting convective initiation (CI) using GEO-KOMPSAT-2A/advanced meteorological imager data. The algorithm identifies clouds that are likely to grow into convective clouds with radar reflectivity greater than 35 dBZ within the next two hours. This algorithm is developed using statistical and qualitative analysis of cloud characteristics, such as atmospheric instability, cloud top height, and phase, for convective clouds that occurred on the Korean Peninsula from June to September 2019. The CI algorithm consists of four steps: 1) convective cloud mask, 2) cloud object clustering and tracking, 3) interest field tests, and 4) post-processing tests to remove non-convective objects. Validation, performed using 14 CI events that occurred in the summer of 2020 in Korean Peninsula, shows a total probability of detection of 0.89, false-alarm ratio of 0.46, and mean lead-time of 39 minutes. This algorithm can be useful warnings of rapidly developing convective clouds in future by providing information about CI that is otherwise difficult to predict from radar or a numerical prediction model. This CI information will be provided in short-term forecasts to help predict severe weather events such as localized torrential rainfall and hail.

Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: a pilot study

  • Iturrate, Mikel;Amezua, Xabier;Garikano, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.191-204
    • /
    • 2021
  • PURPOSE. The purpose of this study is to present a methodology to evaluate the accuracy of intraoral scanners (IOS) used in vivo. MATERIALS AND METHODS. A specific feature-based gauge was designed, manufactured, and measured in a coordinate measuring machine (CMM), obtaining reference distances and angles. Then, 10 scans were taken by an IOS with the gauge in the patient's mouth and from the obtained stereolithography (STL) files, a total of 40 distances and 150 angles were measured and compared with the gauge's reference values. In order to provide a comparison, there were defined distance and angle groups in accordance with the increasing scanning area: from a short span area to a complete-arch scanning extension. Data was analyzed using software for statistical analysis. RESULTS. Deviations in measured distances showed that accuracy worsened as the scanning area increased: trueness varied from 0.018 ± 0.021 mm in a distance equivalent to the space spanning a four-unit bridge to 0.106 ± 0.08 mm in a space equivalent to a complete arch. Precision ranged from 0.015 ± 0.03 mm to 0.077 ± 0.073 mm in the same two areas. When analyzing angles, deviations did not show such a worsening pattern. In addition, deviations in angle measurement values were low and there were no calculated significant differences among angle groups. CONCLUSION. Currently, there is no standardized procedure to assess the accuracy of IOS in vivo, and the results show that the proposed methodology can contribute to this purpose. The deviations measured in the study show a worsening accuracy when increasing the length of the scanning area.

Fabrication of 250 m class Bi-2223/Ag HTS Tapes (250 m 급 Bi-2223/Ag 고온 초전도선재 제조)

  • Ha, H.S.;Oh, S.S.;Ha, D.W.;Jang, H.M.;Kim, S.C.;Song, K.J.;Park, C.;Kwon, Y.K.;Ryu, K.S.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.130-133
    • /
    • 2001
  • A multifilamentary Bi-2223 HTS tape for superconducting power applications was studied through the fabrication of 250-meter long tapes by the PIT(powder in tube) process. To fabricate continuous long wire, a drawing machine, a two-drum bull block and a rolled tape winding machine were developed. Especially, 250-meter long tapes were heat treated in the shape of pancake coil to reduce the heat affect zone and to achieve the high critical current. Engineering critical current density was improved through both the enhancements of critical current density by control of thermal process and the increase of filling factor by using thin Ag alloy sheath tubes less than 1.5 mm in thickness. We have made successfully 250-meter long 37 filamentary tapes with high filling factor up to 31 % employing the modified drawing and rolling technique. The critical current of 250-meter long tapes with pancake coil type was measured by transport method at self-field up to 250 gauss of center field. The measured values, based on the transport critical current at self-field, $I_{c}$ -B characteristics and magnetic field analysis, are 34 A of I$_{c}$ and 4.0 $kA/\textrm{cm}^2$ of $J_{e}$ at 250 m, 77 K, and 0 T. We also have achieved the 56 A of I$_{c}$ and 7.0 $0 kA/\textrm{cm}^2$ of$ J_{e}$ in short tapes at 77K, self-field, and 1$mutextrm{V}$/cm.

  • PDF

Engineering Critical Assessement for an Independent Type-B LNG Cargo Tank (독립형 LNG 화물창의 공학적 결함 평가)

  • Jae Hoon Seo;Kyu-Sik Park;Inhwan Cha;Joonmo Choung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.4
    • /
    • pp.213-221
    • /
    • 2023
  • The demand for Liquefied Natural Gas (LNG) carriers and LNG-fueled ships has significantly increased in recent years due to the sulfur-oxide emission regulations by the International Maritime Organization (IMO). The main goal of this paper is to introduce the process for the Engineering Critical Assessment (ECA) of IMO independent type-B cargo tanks made from 9% nickel alloy. A methodology proposed by the British Standard was used to conduct ECA for any structure with initial flaws. Based on this standard, a Matlab code was developed to perform ECA. Coarse mesh Finite Element Analysis (FEA) was performed on an independent type-B LNG cargo tank with a capacity of 15,000 m3. The location with the highest development of maximum principal stress was identified at the bottom of the cargo tank. Fine mesh FEA was performed to obtain the stress range required for ECA. The dynamic cargo tank loads used for FEA were determined using some ship rules presented by Det Norske Veritas. As a result of performing a 20-year long-term crack propagation analysis with a semi-elliptical surface crack, the fracture-to-yield ratio exceeded the Fracture Assessment Line (FAL) and some structural reinforcement was necessary. Performing a 15-day short-term crack propagation analysis, the fracture-to-yield ratio remained within the FAL, and no significant LNG leaks were expected. This paper is believed to provide a guide for performing ECA of LNG cargo tanks in the future by providing the basic theory and application sample necessary to perform ECA.

Chloride and lactate as prognostic indicators of calf diarrhea from eighty-nine cases

  • Gencay Ekinci;Emre Tufekci;Youssouf Cisse;Ilknur Karaca Bekdik;Ali Cesur Onmaz;Oznur Aslan;Vehbi Gunes;Mehmet Citil;Ihsan Keles
    • Journal of Veterinary Science
    • /
    • v.25 no.3
    • /
    • pp.38.1-38.16
    • /
    • 2024
  • Importance: Deaths due to neonatal calf diarrhea are still one of the most critical problems of cattle breeding worldwide. Determining the parameters that can predict diarrhea-related deaths in calves is especially important in terms of prognosis and treatment strategies for the disease. Objective: The primary purpose of this study was to determine mortality rates and durations, survival status, and predictive prognosis parameters based on vital signs, hematology, and blood gas analyses in neonatal diarrheic calves. Methods: The hospital automation system retrospectively obtained data from 89 neonatal diarrheic calves. Results: It was found that 42.7% (38/89) of the calves brought with the complaint of diarrhea died during hospitalization or after discharge. Short-term and long-term fatalities were a median of 9.25 hours and a median of 51.50 hours, respectively. When the data obtained from this study is evaluated, body temperature (℃), pH, base excess (mmol/L), and sodium bicarbonate (mmol/L) parameters were found to be lower, and hemoglobin (g/dL), hematocrit (%), lactate (mmol/L), chloride (mmol/L), sodium (mmol/L) and anion gap (mmol/L) parameters were found to be higher in dead calves compared to survivors. Accordingly, hypothermia, metabolic acidosis, and dehydration findings were seen as clinical conditions that should be considered. Logistic regression analysis showed that lactate (odds ratio, 1.429) and CI- (odds ratio, 1.232) concentration were significant risk factors associated with death in calves with diarrhea. Conclusions and Relevance: According to the findings obtained from this study, the determination of lactate and Cl- levels can be used as an adjunctive supplementary test in distinguishing calves with diarrhea with a good prognosis.

MORPHOLOGY OF THE TERMINAL ARBORS FROM THE MASSETERIC MUSCLE SPINDLE AFFERENTS IN THE TRIGEMINAL MOTOR NUCLEUS (삼차신경 운동핵에서 교근 근방추 구심성 신경섬유 종말지의 미세구조)

  • Lee, Kyung-Woo;Bae, Yong-Chul;Kim, Chin-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.3
    • /
    • pp.321-347
    • /
    • 1994
  • Muscle spindle afferents from masseter muscle were labelled by the intra-axonal HRP injection and were processed for light microscopic reconstruction. Regions containing terminal arbors scattered in the central portion of the masseteric motor neuron pool (type I a) and those restricted to 2-3 small portion of it (type II) were selected and processed for electronmicroscopic analysis with serial sections. The shape of the labelled boutons was dome or elongated shape. Scalloped or glomerulus shape with peripherial indentation containing pre or postsynaptic neuronal propiles, which is occasionally found in the trigeminal main sensory nucleus and spinal dorsal horn, was not observed. Both type Ia and type II boutons had pale axoplasm and contained clear, spherical vesicles of uniform size(dia : 49-52nm) and occasionally large dense cored vesicles(dia : 87-118nm). The synaptic vesicles were evenly distributed throughout the boutons although there was a slight tendency of vesicles to accumulate at the presynaptic site. The average of short and long diameter(short D. + long D./2) of type I a bouton was smaller than that of type II bouton. All the labelled boutons, which showed prominent postsynaptic density, large synaptic area and multiple synaptic contact, made asymmetrical synaptic contact with postsynaptic neuronal propiles. Most of the type Ia and type II boutons made synaptic contact with only one neuronal propile and boutons which shows synaptic contact or more neuronal propiles was not observed. Most of the type Ia boutons(87.2%) were presynaptic to the soma or proximal dendrite and a few remainder(12.8%) made synaptic contact with dendritic shaft or distal dendrite. In contrast, majority of type II boutons showed synaptic contact with dendritic shaft and remainder with soma or proximal dendrite. In conclusion, terminal boutons which participate in the excitatory monosynaptic jaw jerk reflex made synaptic contact with more proximal region of the neuron, and showed very simple synaptic connection, compared with those from the primary afferenst in the other region of the central nervous system such as spinal dorsal horn and trigeminal main sensory nucleus which assumed to be responsible for the mediating pain, tactile sensation, sensory processing or sensory discrimination.

  • PDF

Inhibitory Effects of Functional Sujeonggwa Drinks on Hepatic Lipid Accumulation in Hypercholesterolemic ApoE Knockout Mice (고콜레스테롤혈증 ApoE Knockout Mice에서 기능성 수정과의 간지질 축적 억제 효과)

  • Baek, Aran;Kim, Mijeong;Jung, Koeun;Kim, Seulki;Lee, Jeehyun;Song, Yeong Ok
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.11
    • /
    • pp.1648-1657
    • /
    • 2014
  • In this study, the hepatic lipid-lowering effects and related mechanism of action of sujeonggwa were examined in hypercholesterolemia-induced apoprotein E knockout (apo E ko) mice. Sujeonggwa drink was prepared with cinnamon, ginger, and sugar by modifying the traditional recipe of sujeonggwa. Sugar was partially substituted with either stevia or short chain fructooligosaccharide (scFOS) in order to reduce the calorie content of sujeonggwa, which was measured by descriptive analysis. Apo E ko mice (n=42) were induced to have hypercholesterolemia (plasma total cholesterol concentration >1,000 mg/dL) by administration of a high cholesterol diet for 4 weeks, followed by division into six groups. Experimental groups were orally administered water as a vehicle (normal group), sugar solution (control group), commercially available 'V' sujeonggwa drink (positive control group), or three different types of sujeonggwa drinks (S-sugar, S-stevia, and S-scFOS group) for 6 weeks while high cholesterol diet was provided to all animals. Compared to the control group, concentrations of hepatic triglycerides, total cholesterol, thiobarbituric acid reactive substances, and reactive oxygen species in S-sugar, S-stevia, S-scFOS were significantly reduced (P<0.05), indicating that sujeonggwa had inhibitory effects on hepatic lipid accumulation. Protein expression levels of fatty acid synthase (FAS) and its transcription factor, sterol regulatory element-binding protein (SREBP)-1 responsible for triglyceride synthesis, as well as 3-hydroxy-3-methylglutaryl-CoA reductase (HMGCR) and its transcription factor, SREBP-2 responsible for cholesterol synthesis, were also reduced in S-sugar, S-stevia, and S-scFOS groups (P<0.05). These benefits of sujeonggwa were even greater in S-stevia and S-scFOS compared to S-sugar. The beneficial effects of S-stevia on regulation of hepatic lipid metabolism were slightly greater than those of S-scFOS although the differences were not significant. In conclusion, sujeonggwa drinks, especially functional sujeonggwa drinks in which sugar was partially substituted with stevia or scFOS, inhibited hepatic lipid accumulation via suppressing FAS and HMGCR protein expression through down-regulation of SREBP-1 and 2.