• Title/Summary/Keyword: 3D Sensitivity Curve

Search Result 56, Processing Time 0.023 seconds

Predictive Value of Baseline Plasma D-dimers for Chemotherapy-induced Thrombocytopenia in Patients with Stage III Colon Cancer: A Pilot Study

  • Tanriverdi, Ozgur
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.293-297
    • /
    • 2013
  • Background: : Chemotherapy-induced thrombocytopenia (CIT) is an important cause of morbitity in patients with cancer. Aim: To investigate the effect of the baseline plasma D-dimer level, an important marker for thrombotic activity, on chemotherapy-induced thrombocytopenia in patients with stage III colon cancer. Materials and Methods: A total of 43 (28 men) eligible patients were divided into two groups according to whether they exhibited chemotherapy-induced thrombocytopenia: Group 1 (n=21) and Group 2 (n=22). Comparison was made using demographic, histopathologic, and laboratory variables. Additionally, baseline plasma D-dimer levels underwent receiver operation characteristics curve analysis, and areas under the curve were calculated. Sensitivity, specificity, and positive and negative likelihood rates were then determined. Results: The incidence of chemotherapy-induced thrombocytopenia had a significant correlation with baseline platelet count (r=0.568, P=0.031) and baseline plasma D-dimer levels (r=0.617, P=0.036). When the cut-off point for the latter was set as 498 ng/mL, the area under the curve was 0.89 (95%CI: 0.74-0.93), the sensitivity was 91.4%, the specificity was 89.7%, the positive likelihood rate was 3.64 and the negative likelihood rate was 0.24 for chemotherapy-induced thrombocytopenia diagnosis. Conclusions: The baseline level of plasma D-dimer could help to differentiate high-risk patients for chemotherapy-induced thrombocytopenia.

Study of the Annoyance Sensitivity for the Frequency Band of Road Traffic Noise (도로교통소음의 주파수에 따른 불쾌도 민감도 연구)

  • Jo, Kyoung-Sook;Hwang, Dae-Sun;Cho, Yeo;Hur, Deog-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.5 s.122
    • /
    • pp.398-404
    • /
    • 2007
  • In this study, the sensitivity of annoyance was investigated by the subjective jury test for the variations of the frequency components along with various sound pressure levels of sixteen environmental noise sources. Annoyance was, also, evaluated for the road traffic noises. Sound pressure levels were $54{\sim}84\;dB$ which individually divided frequency components with eight bands of equally three bark bands. The results show that vehicle traffic noise is recognized as the most serious environment noise source. The sensitivity of human perception of annoyance in frequency bands is quite different from A-weighting curve. The annoyance found out to be more sensitive in high frequency region and reached its maximum in 3.4 kHz.

Repeaterless Transmission of 2.5Gbps Signal Over 98Km Optical Fibers (2.5 Gbps 신호의 98km 무중계 광섬유 전송)

  • 윤태열;한정희;이창희;심창섭
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.2
    • /
    • pp.26-38
    • /
    • 1994
  • We demonstrate a repeatless transmission of 2.5 Gbps digital signal over 98 km opticla filbers using optical transmitter and optcial receiver which are designed and implemented using commercially available devices. The optical transmitter is realized by using a distributed feedback(DFB) laser. Temperature of the laser is thermoelectrically stabilized and the output optical power is also stabilized by using negative feedback. The output power of the transmitter is 0 dBm. The optical receiver consists of an InGaAs avalanche photodiode, a preamplifier. an automatic gain control amplifier, and a clock/data regenerator. We find an optimum decision threshold that gives the best receiver sensitivity form the measured V curve. The best sensitivity is -35.5dBm( BER-1*10S010T, PRBS=2S023T -1 ) and the overload power is -9 dBm. Finally, we achieve error free optical transmission with 98 km optical fibers. The exinction ration penalty of 2 dB. the chromatic dispersion penalty of 1 dB, and the total power penalty of 3.0 dB are measured. These results satisfy CCITT recommendation.

  • PDF

Accuracy of the 2008 Simplified Criteria for the Diagnosis of Autoimmune Hepatitis in Children

  • Arcos-Machancoses, Jose Vicente;Busoms, Cristina Molera;Tatis, Ecaterina Julio;Bovo, Maria Victoria;Bernabeu, Jesus Quintero;Goni, Javier Juamperez;Martinez, Vanessa Crujeiras;Martin de Carpi, Javier
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.2
    • /
    • pp.118-126
    • /
    • 2018
  • Purpose: Classical criteria for diagnosis of autoimmune hepatitis (AIH) are intended as research tool and are difficult to apply at patient's bedside. We aimed to study the accuracy of simplified criteria and the concordance with the expert diagnosis based on the original criteria. Methods: A cohort of children under study for liver disorder was selected through consecutive sampling to obtain the prevalence of AIH within the group of differential diagnoses. AIH was defined, based on classical criteria, through committee review of medical reports. Validity indicators of the simplified criteria were obtained in an intention to diagnose approach. Optimal cut-off and the area under the receiver operating characteristic (ROC) curve were calculated. Results: Out of 212 cases reviewed, 47.2% were AIH. For the optimal cut-off (6 points), the simplified criteria showed a sensitivity of 72.0% and a specificity of 96.4%, with a 94.7% positive and a 79.4% negative predictive value. The area under the ROC curve was 94.3%. There was a good agreement in the pre-treatment concordance between the classical and the simplified criteria (kappa index, 0.775). Conclusion: Simplified criteria provide a moderate sensitivity for the diagnosis of AIH, but may help in indicating treatment in cases under suspicion with 6 or more points.

Role of Multislice Computerized Tomographic Angiography after Clip Placement in Aneurysm Patients Based on Comparison with Three Dimensional Digital Subtraction Angiography

  • Han, Myung-Hwan;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.103-111
    • /
    • 2007
  • Objective : We evaluated the accuracy of multislice computerized tomographic angiography (MCTA) in the postoperative evaluation of clipped aneurysms by comparising it with three dimensional digital subtraction angiography (3D-DSA). Methods : Between May 2004 and September 2006, we included patients with ruptured cerebral aneurysm of the anterior circulation that was surgically clipped and evaluated by both postoperative MCTA and postoperative 3D-DSA. We measured the diagnostic performance and calculated the sensitivity and specificity of postoperative MCTA compared to 3D-DSA in the detection of aneurysm remnants. Results : A total of 11 neck remnants among the 92 clipped aneurysms (11.9%) were confirmed by 3D-DSA. According to Sindou's classification of aneurysm remnants, 8.7% of clipped aneurysms (8/92) had only neck remnant on 3D-DSA and 3.2% (3/92 aneurysms) had residuum of the neck and sac on 3D-DSA. There were 12 (13.04%) equivocal cases that were difficult to interpret based on the postoperative MCTA. The reasons for the equivocal cases included multiple clips (6 cases, 50.0%). beam-hardening effect (4 cases, 33.3%), motion artifact (1 case, 8.3%), fenestrated clip (1 case, 8.3%) and other combined causes. The sensitivity and specificity of the postoperative MCTA was 81.8% and 88.9%, respectively by ROC curve (p=0.000). Conclusion : MCTA is an accurate noninvasive imaging method used for the assessment of clipped aneurysms in the anterior circulation. If the image quality of postoperative MCTA is good quality and the patient has been treated with a single titanium clip, except a fenestrated clip, the absence of an aneurysm remnant can be diagnosed by MCTA alone and the need for postoperative DSA can be reduced in a large percentage of cases.

Diagnostic value of eosinopenia and neutrophil to lymphocyte ratio on early onset neonatal sepsis

  • Wilar, Rocky
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.6
    • /
    • pp.217-223
    • /
    • 2019
  • Purpose: To determine the diagnostic value of eosinopenia and the neutrophil-to-lymphocyte ratio (NLR) in the diagnosis of early onset neonatal sepsis (EONS). Methods: This cross-sectional study was conducted in the Neonatology Ward of R.D. Kandou General Hospital Manado between July and October 2017. Samples were obtained from all neonates meeting the inclusion criteria for EONS. Data were encoded using logistic regression analysis, the point-biserial correlation coefficient, chi-square test, and receiver operating characteristic curve analysis, with a P value <0.05 considered significant. Results: Of 120 neonates who met the inclusion criteria, 73 (60.8%) were males and 47 (39.2%) were females. Ninety (75%) were included in the sepsis group and 30 (25%) in the nonsepsis group. The mean eosinophil count in EONS and non-EONS groups was $169.8{\pm}197.1cells/mm^3$ and $405.7{\pm}288.9cells/mm^3$, respectively, with statistically significant difference (P<0.001). The diagnostic value of eosinopenia in the EONS group (cutoff point: $140cells/mm^3$) showed 60.0% sensitivity and 90.0% specificity. The mean NLR in EONS and non-EONS groups was $2.82{\pm}2.29$ and $0.82{\pm}0.32$, respectively, with statistically significant difference (P<0.001). The diagnostic value of NLR in the EONS group (cutoff point, 1.24) showed 83.3% sensitivity and 93.3% specificity. Conclusion: Eosinopenia has high specificity as a diagnostic marker for EONS and an increased NLR has high sensitivity and specificity as a diagnostic marker for EONS.

Hydrocephalus: Ventricular Volume Quantification Using Three-Dimensional Brain CT Data and Semiautomatic Three-Dimensional Threshold-Based Segmentation Approach

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.435-441
    • /
    • 2021
  • Objective: To evaluate the usefulness of the ventricular volume percentage quantified using three-dimensional (3D) brain computed tomography (CT) data for interpreting serial changes in hydrocephalus. Materials and Methods: Intracranial and ventricular volumes were quantified using the semiautomatic 3D threshold-based segmentation approach for 113 brain CT examinations (age at brain CT examination ≤ 18 years) in 38 patients with hydrocephalus. Changes in ventricular volume percentage were calculated using 75 serial brain CT pairs (time interval 173.6 ± 234.9 days) and compared with the conventional assessment of changes in hydrocephalus (increased, unchanged, or decreased). A cut-off value for the diagnosis of no change in hydrocephalus was calculated using receiver operating characteristic curve analysis. The reproducibility of the volumetric measurements was assessed using the intraclass correlation coefficient on a subset of 20 brain CT examinations. Results: Mean intracranial volume, ventricular volume, and ventricular volume percentage were 1284.6 ± 297.1 cm3, 249.0 ± 150.8 cm3, and 19.9 ± 12.8%, respectively. The volumetric measurements were highly reproducible (intraclass correlation coefficient = 1.0). Serial changes (0.8 ± 0.6%) in ventricular volume percentage in the unchanged group (n = 28) were significantly smaller than those in the increased and decreased groups (6.8 ± 4.3% and 5.6 ± 4.2%, respectively; p = 0.001 and p < 0.001, respectively; n = 11 and n = 36, respectively). The ventricular volume percentage was an excellent parameter for evaluating the degree of hydrocephalus (area under the receiver operating characteristic curve = 0.975; 95% confidence interval, 0.948-1.000; p < 0.001). With a cut-off value of 2.4%, the diagnosis of unchanged hydrocephalus could be made with 83.0% sensitivity and 100.0% specificity. Conclusion: The ventricular volume percentage quantified using 3D brain CT data is useful for interpreting serial changes in hydrocephalus.

Comparison of Diagnostic Accuracies of Serum HE-4 Levels and 3D Power Doppler Angiography Parameters between Benign Endometrial Pathologies and Endometrial Cancer

  • Erenel, Hakan;Bese, Tugan;Sal, Veysel;Demirkiran, Fuat;Arvas, Macit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2507-2511
    • /
    • 2016
  • Purpose: To study the diagnostic accuracies of serum human epididymis protein 4 (HE-4) levels, virtual organ computer-aided analysis (VOCAL) parameters and endometrial volume in endometrial cancer cases. Materials and Methods: One hundred and seven patients (37 with endometrial cancer and 70 with benign endometrial pathology) were included in this study. VOCAL parameters and serum HE-4 levels were compared between the groups. Results: Area under the curve (AUC) values were 0.702, 0.658, 0.706 for vascularization index (VI), the flow index (FI) and the vascularization flow index (VFI), respectively. A cut off value of 0.568 for VI demonstrated 70% sensitivity, 72% specificity, 56% positive predictive value (PPV) and a81% negative predictive value (NPV). A cut off value of 25.8 for showed a senitivith of 70% and a specificity of 58% with aPPV of 46% and NPV of 78%, and with a cut off value of 0.12 for VFI 70%, 69%, 54% and 81%, respectively. The area under the curve for HE-4 was 0.814. A cut off value of 458 pmol/L was predictive of malignancy with 86% sensitivity and 63% specificity. Conclusions: VOCAL parameters and serum HE-4 levels were statistically significantly higher in the endometrial cancer patients. Serum HE-4 levels provided a greater sensitivity compared to power doppler angiography for predicting malignancy or benign endometrial pathology.

Development an Artificial Neural Network to Predict Infectious Bronchitis Virus Infection in Laying Hen Flocks (산란계의 전염성 기관지염을 예측하기 위한 인공신경망 모형의 개발)

  • Pak Son-Il;Kwon Hyuk-Moo
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.105-110
    • /
    • 2006
  • A three-layer, feed-forward artificial neural network (ANN) with sixteen input neurons, three hidden neurons, and one output neuron was developed to identify the presence of infectious bronchitis (IB) infection as early as possible in laying hen flocks. Retrospective data from flocks that enrolled IB surveillance program between May 2003 and November 2005 were used to build the ANN. Data set of 86 flocks was divided randomly into two sets: 77 cases for training set and 9 cases for testing set. Input factors were 16 epidemiological findings including characteristics of the layer house, management practice, flock size, and the output was either presence or absence of IB. ANN was trained using training set with a back-propagation algorithm and test set was used to determine the network's capability to predict outcomes that it has never seen. Diagnostic performance of the trained network was evaluated by constructing receiver operating characteristic (ROC) curve with the area under the curve (AUC), which were also used to determine the best positivity criterion for the model. Several different ANNs with different structures were created. The best-fitted trained network, IBV_D1, was able to predict IB in 73 cases out of 77 (diagnostic accuracy 94.8%) in the training set. Sensitivity and specificity of the trained neural network was 95.5% (42/44, 95% CI, 84.5-99.4) and 93.9% (31/33, 95% CI, 79.8-99.3), respectively. For testing set, AVC of the ROC curve for the IBV_D1 network was 0.948 (SE=0.086, 95% CI 0.592-0.961) in recognizing IB infection status accurately. At a criterion of 0.7149, the diagnostic accuracy was the highest with a 88.9% with the highest sensitivity of 100%. With this value of sensitivity and specificity together with assumed 44% of IB prevalence, IBV_D1 network showed a PPV of 80% and an NPV of 100%. Based on these findings, the authors conclude that neural network can be successfully applied to the development of a screening model for identifying IB infection in laying hen flocks.

Feasibility and reliability of various morphologic features on magnetic resonance imaging for iliotibial band friction syndrome

  • Jin Kyem Kim;Taeho Kim;Hong Seon Lee;Dong Kyu Kim
    • The Korean Journal of Pain
    • /
    • v.36 no.2
    • /
    • pp.208-215
    • /
    • 2023
  • Background: To evaluate the feasibility, inter-reader reliability, and intra-reader reliability for various morphological features reported to be related to iliotibial band friction syndrome (ITBFS) on knee magnetic resonance imaging (MRI). Methods: A total of 145 patients with a clinical diagnosis and knee MRI findings consistent with ITBFS were included in the "study group" and 232 patients without knee pathology on both physical examination and MRI were included in the "control group". Various morphologic features on knee MRI were assessed including the patella shape, patella height, lateral epicondyle anterior-posterior (AP) width, lateral epicondyle height, ITB diameter (ITB-d), and ITB area (ITB-a). Results: Patients in the study group had significantly higher lateral epicondyle height (13.9 mm vs. 12.92 mm, P = 0.003), ITB-d (2.9 mm vs. 2.0 mm, P = 0.022), and ITB-a (38.5 mm2 vs. 23.8 mm2, P < 0.001) than the control group. ITB-a showed higher area under the curve index (0.849 with 74.1% sensitivity and 72.4% specificity at a 30.3 mm2 cutoff) than ITB-d (0.710 with 70.8% sensitivity and 61.2% specificity at 2.4 mm cutoff) and lateral epicondyle height (0.776 with 72.4% sensitivity and 67.8% specificity at 13.4 mm cutoff). However, only the inter-reader agreement for ITB-a (intraclass correlation coefficient = 0.65) was moderate, while the agreements for other morphologic features were good or excellent. Conclusions: Lateral epicondyle height seems to be a reliable and feasible morphologic feature for diagnosis of ITBFS.