• Title/Summary/Keyword: 3D Printing Sensor

Search Result 48, Processing Time 0.027 seconds

A Study on The Thickness Shrinkage of Injection Molded Parts with The Variation of Injection Mold Core and Molding Materials (사출금형코어 및 성형수지 변화에 따른 두께 방향 수축률에 관한 연구)

  • Shin, Sung-Hyun;Jeong, Eui-Chul;Kim, Mi-Ae;Chae, Bo-Hye;Son, Jung-Eon;Kim, Sang-Yoon;Yoon, Kyung-Hwan;Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.17-21
    • /
    • 2019
  • In this study, selective laser sintered 3D printing mold core and metal core were used to investigate the difference of the thickness shrinkage from the gate of the injection molded part at a constant interval. SLS 3D printing mold core was made of nylon-based PA2200 powder and the metal core was manufactured by conventional machining method. As the PA2200 powder material has low strength, thermal conductivity and high specific heat characteristics compared with metal, molding conditions were set with the consideration of molten temperature and injection pressure. Crystalline resin(PP) and amorphous resin(PS) with low melting temperature and viscosity were selected for the injection molding experiment. Cooling time for processing condition was selected by checking the temperature change of the cores with a cavity temperature sensor. The cooling time of the 3D printing core was required a longer time than that of the metal core. The thickness shrinkage of the molded part compared to the core depth was measured from the gate by a constant interval. It was shown that the thickness shrinkage of the 3D printing core was 2.02 ~ 4.34% larger than that of metal core. In additions, in the case of metal core, thickness shrinkage was increased with distance from the gate, on the contrary, in the case of polymer core showed reversed aspect.

Di(propylene glycol) Methylether (DPGME) Sensing Characteristics of SnO2-ZnO Sensor (SnO2센서의 ZnO 첨가량에 따른 di(propylene glycol) methylether (DPGME)에 대한 반응 특성)

  • Cha G. Y;Baek W. W;Yun K. Y;Lee S. T;Choi N. J;Lee D. D;Huh J. S
    • Korean Journal of Materials Research
    • /
    • v.14 no.3
    • /
    • pp.224-228
    • /
    • 2004
  • Respectively the powder made of ZnO added $SnO_2$ was prepared by coprecipitation method and the thick film gas sensor was fabricated by screen-printing technique, The morphology and phase of the powder and film was investigated by SEM and XRD. The specific area of the particle was linearly increased with ZnO contents. Target gas was di(propylene glycol) methylether ($CH_3$($OC_3$$H_{6}$ )$_2$OH, DPGME), which is simulant gas of blister gas. The gas sensing characteristics for DPGME were examined with flow type measurement system and the concentrations of target gas were controlled from 500 ppb to 1500 ppb. ZnO (2 wt%) added $SnO_2$ showed maximum sensitivity to DPGME at $300^{\circ}C$.

3D Printed Water Strider Robot with Environmental Monitoring (환경모니터링이 가능한 3D 프린팅 소금쟁이 로봇)

  • Shim, Ga-hyun;Lee, Kihak;Chun, Kyunghan;Cho, Chanseob;Kim, Bonghwan
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.407-413
    • /
    • 2019
  • Using 3D printing technology, we created a biomimetic water strider robot that can monitor environments. We found ways to increase the bearing capacity of the fluid-driven water strider robot by conducting experiments then comparing with more stable robots. The controller of the robot is based on Arduino, and can be controlled wirelessly with a Bluetooth module. The speed of the robot is 7.37 cm/s, and the bearing capacity is 29 g. A lithium polymer battery that can be charged with a solar cell was used as a power source, and both the charging and driving times were also explored.

Fabrication and characteristics of La1-xSrxMO3(M = Fe, Co, Mn) formaldehyde gas sensors (La1-xSrxMO3(M = Fe, Co, Mn) 물질을 이용한 포름알데히드 가스센서의 제조와 특성)

  • Kim, H.J.;Choi, J.B.;Kim, S.D.;Yoo, K.S.
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.203-209
    • /
    • 2008
  • Thick film formaldehyde (HCHO) gas sensors were fabricated by using $La_1_{-x}Sr_xMO_3$ (M= Fe, Co, Mn) ceramics. The powders of $La_1_{-x}Sr_xMO_3$ (M=Fe, Co, Mn) were synthesized by conventional solid-state reaction method. By using the $La_1_{-x}Sr_xMO_3$ (M=Fe, Co, Mn) paste, the thick-film formaldehyde sensors were prepared on the alumina substrate by silkscreen printing method. The experimental results revealed that $La_1_{-x}Sr_xMO_3$ (M= Fe, Co, Mn) ceramic powder has a perovskite structure and the thick-film sensor shows excellent gas-sensing characteristics to formaldehyde gas (sensitivity of $La_{0.8}Sr_{0.2}FeO_3$, S= 14.7 at operating temperature of $150^{\circ}C$ in 50 ppm HCHO ambient).

A Study on the Design of Alarms to Maintain the distance in the COVID-19 Era. (코로나19시대의 거리유지를 위한 경보기 디자인에 관한 연구)

  • Kang, Hee-Ra
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.513-518
    • /
    • 2022
  • In the past two years, all sectors of society have been underdeveloped and suffered a significant damage due to COVID-19. In particular, people who were working in many areas of research were unable to do anything due to restrictions on meetings with people and social distancing. The purpose of this study is to develop a social distancing device that allows users to maintain the distance in accordance with the government guidelines through an analysis of people's social distancing methods in the COVID-19 society through UX Design. In order to develop the social distancing device, the distance is expressed by changing the color of LED based on research related to UI design such as ultrasonic distance sensor, battery, charging method, distance display method, etc. The outer form of the social distancing device is designed using 3D, the device is developed by installing ultrasonic distance sensor, neo-pixel module and Arduino after printing a prototype using a 3D printer, and this device is tested to develop a final product that helps the social distancing practice amid COVID-19.

Tape-Type Liquid Leakage Film Sensor (액체누설 감지용 테이프형 필름센서)

  • Yu, D.K.;Kim, K.S.;Yub, H.K.;Han, G.H.;Jin, D.J.;Kim, J.H.;Han, S.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.146-154
    • /
    • 2011
  • The adhesive-tape of a liquid leak film sensor including the alarm system is developed. The sensing film is composed of three layers such as base film layer, conductive line layer, and protection film layer. The thickness of film is 300~500 um, the width is 3.55 cm, and the unit length is 200 m. On the conductive line layer, three conducting lines and one resistive line are formulated by the electronic printing method with a conducting ink of silver-nano size. When a liquid leaks for the electricity to be conducted between the conductive line and the resistive line, the position of leakage is monitored by measuring the voltage varied according to the change of resistance between two lines. The error range of sensing position of 200 m film sensor is ${\pm}1m$.

A Study on Tensile Strength of the 3D Printing Product According to the Nitrogen Concentration of Chamber Inside (챔버 내부의 질소 농도에 따른 3D프린팅 출력물의 인장 강도에 관한 연구)

  • Lee, Song Yeon;Huh, Yong Jeong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.103-107
    • /
    • 2022
  • Scaffolds are the structures that safely protect sensors in various parts of the body. Because of scaffolds must protect sensors from load, the tensile strength of the scaffolds must be higher than 750 kgf/cm2. Currently, the tensile strength of scaffolds made with the 3d printer is 714 kgf/cm2. We confirm that the tensile strength of the scaffolds increase using air with high nitrogen concentration. In this study, we conducted experiments to find nitrogen concentrations in which the tensile strength of the specimen is higher than 750 kgf/cm2. The nitrogen control device and the nitrogen concentration sensor were installed in the chamber type 3d printer. The nitrogen concentration inside the 3d printer was changed by 5 % from 80 % to 100 %. Specimens of ASTM D 638 standard were produced under changed nitrogen concentration. We measured the tensile strength of specimens. We compared the tensile strength of specimens produced under each nitrogen concentration. We confirmed that when air with nitrogen concentration of 90 % was used, the tensile strength of scaffolds were 762 kgf/cm2.

A study on the digitalization of 3D Pen (3D펜의 디지털화에 대한 연구)

  • Kim, Jong-Young;Jeon, Byung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.583-590
    • /
    • 2021
  • This paper is a study on the digitization of an analog 3D pen. The term digital implies features such as homeostasis, transformability, combinability, reproducibility, and convenience of storage. One device that produces a combination of these digital characteristics is a 3D printer, but its industrial use is limited due to low productivity and limitations with materials and physical characteristics. In particular, improvements are required to use 3D printers, such as better user accessibility owing to expertise and skills in modeling software and printers. Complementing this fact is the 3D pen, which is excellent in portability and ease of use, but has a limitation in that it cannot be digitized. Therefore, in order to secure a digitalization capability and ease of use, and to secure the safety of printing materials that pose controversial hazards during the printing process, research problems and alternatives have been derived by combining food, and digitization was demonstrated with a newly developed 3D pen. In order to digitize the 3D pen, a sensor in a structured device detects the motion of an analog 3D pen, and this motion is converted into 3D data (X-Y-Z coordinate values) through a spatial analysis algorithm. To prove this method, the similarity was confirmed by visualization using MeshLab version 1.3.4. It is expected that this food pen can be used in youth education and senior healthcare programs in the future.

Fabrication and characteristics of alcohol sensor using Fe2O3 (Fe2O3후막을 이용한 alcohol sensor 제작 및 감응특성)

  • Lee, Y.S.;Song, K.D.;Lee, S.M.;Shim, C.H.;Choi, N.J.;Joo, B.S.;Lee, D.D.;Huh, J.S.
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.77-83
    • /
    • 2002
  • In order to get low cost and portability, semiconductor gas sensor need to have low operating temperature and high sensitivity. $Fe_2O_3$ based sensors which were doped with metal oxide catalysts($MoO_3$, $V_2O_5$, $TiO_2$, and CdO) were fabricated by screen printing method. To improve electrical stability of sensors, the $Fe_2O_3$ sensors were annealed in $N_2$ at $700^{\circ}C$ for 2 hours. The $V_2O_5$ doped $Fe_2O_3$ sensor showed about $80{\sim}90%$ sensitivity at alcohol 1,000 ppm and have good selectivity to hydrocarbon gas and tobacco odors. The fabricated sensor and PIC-chip were employed for portable alarm system.

Disposable Glucose Sensor Based on Platinised Carbon Paste Electrode (백금 도금된 탄소반죽 전극을 이용한 일회용 글루코오스 센서)

  • Lee Dong Joo;Yoo Jae Hyun;Cui Gang;Choi Moon Hee;Kim Moon Hwan;Ryu Joon Oh;Han Sang-Hyun;Cha Geun Sig;Nam Hakhyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.4
    • /
    • pp.227-231
    • /
    • 1999
  • Disposable, amperometric glucose sensor was constructed using platinised carbon paste electrode. The sensor response was studied by amperometry and cyclic voltammetry applying sample solutions on the strip-type electrode. Platinization of screen-printed carbon paste electrode effectively improved the electrochemical reversibility of a mediator and the analytical characteristics of the sensor. The heterogeneous rate constant for $[Fe(CN)_6]^{4-/3-}$ was $1.45\times10^{-2}cm{\cdot}s^{-1}$. An applied potential of 0.3V vs. Ag/AgCl resulted in the best selectivity for glucose. The apparent Michaelis-Menten constant for glucose on the strip sensor, $K_m^{app}$, was 24.5 mM. To evaluate the analytical performance of the glucose sensor strip, a correlation study was performed with the NOVA S.P, Ultra M analyzer for 30 serum samples containing $80\~297mg/dL$ of glucose: the correlation coefficient value was 0.983. It can be seen that the strip sensor has satisfactory precision and accuracy.