• 제목/요약/키워드: 3D Image Scan

검색결과 233건 처리시간 0.03초

실시간 3 차원 링클 측정 시스템 (Development of Online 3D Wrinkle Measurement System)

  • 호앙후평;토호앙밍;고성림
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1255-1258
    • /
    • 2008
  • Roll to roll (R2R) system, known as 'web processing', is the process of producing these electronic devices on a roll of flexible plastic. With the need of improved performance and productivity in R2R industry, effective control and on-line supervision for web quality is essential. In this report, we present a system for on-line measurement of wrinkles, one of defects incurring due to compressive stresses developed in the web. This system is able to capture an image generated when a well defined line shape laser beam passes through a transparent web. The system calculates 3D shape information, including the height of the wrinkle on the web, and displays the images for the shape information of the web in real time. By using area scan camera and machine vision laser, this system takes more advantages of setting up as a simple and low cost system compared to the line scan camera systems that widely used in web manufacturing. Specific calibration method and analysis on the achievable accuracy will be discussed.

  • PDF

딥러닝을 이용한 구강 스캐너 이미지 내 치아 영역 실시간 검출 (Real-time Tooth Region Detection in Intraoral Scanner Images with Deep Learning)

  • 박나윤;김지훈;김태민;송경진;변유진;강민주;전경구;김재곤
    • 산업경영시스템학회지
    • /
    • 제46권3호
    • /
    • pp.1-6
    • /
    • 2023
  • In the realm of dental prosthesis fabrication, obtaining accurate impressions has historically been a challenging and inefficient process, often hindered by hygiene concerns and patient discomfort. Addressing these limitations, Company D recently introduced a cutting-edge solution by harnessing the potential of intraoral scan images to create 3D dental models. However, the complexity of these scan images, encompassing not only teeth and gums but also the palate, tongue, and other structures, posed a new set of challenges. In response, we propose a sophisticated real-time image segmentation algorithm that selectively extracts pertinent data, specifically focusing on teeth and gums, from oral scan images obtained through Company D's oral scanner for 3D model generation. A key challenge we tackled was the detection of the intricate molar regions, common in dental imaging, which we effectively addressed through intelligent data augmentation for enhanced training. By placing significant emphasis on both accuracy and speed, critical factors for real-time intraoral scanning, our proposed algorithm demonstrated exceptional performance, boasting an impressive accuracy rate of 0.91 and an unrivaled FPS of 92.4. Compared to existing algorithms, our solution exhibited superior outcomes when integrated into Company D's oral scanner. This algorithm is scheduled for deployment and commercialization within Company D's intraoral scanner.

자기공명영상을 이용한 두개부내 표적의 3차원적 위치결정 (Determination of Stereotactic Target Position with MR Localizer)

  • 최태진;김옥배;주양구;서수지;손은익
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.67-77
    • /
    • 1996
  • 목적 : 전신자기공명영상장치의 두개부코일링에 삽입할 수 있는 뇌정위표적기를 제작하고, 횡단면, 시상면 및 관상면에서 표적의 입체적 위치를 결정하여 비교하였다. 방법 : 고강도 합성수지를 이용하여 1.5T 의 전신자기공명 영상장치에서 뇌정위시술용 두 개 부고정환에 부착하여 두개부내 표적위치를 결정할 수 있는 뇌정위표적기를 시험제작하였다. 본 연구에서 시험제작된 뇌정위표적기는 자기공명장치 Magnetom 1.5T(Siemens사, 독일)의 두부코일(외경이 260mm) 내에 설치할 수 있도록 하였으며, 횡단면이나 시상면 또는 관상면에서 표적의 위치를 3차원적으로 결정할 수 있게 하여 각 단면에서 결정된 가상표적의 위치를 비 교하였다. 결과 : 위치가 서로 다른 2개의 가상표적에 대한 모의실험 결과, 횡단면에서 x축의 최대오차는 -1.4mm, y축 -0.7mm, z축 1.lmm를 얻었으며, 시상면에서는 X축 1.3, Y축 1.0mm, Z축 1.lmm, 관상면에서는 X축 -1.4mm, Y축 1.1mm, Z축 -1.5mm로 나타나 횡단면, 시상면 및 관상면에서 구한 표적값이 실험오차범위에서 거의 일치하였다. 결론 : 고강도 합성수지를 이용하여 시험제작한 자기공명영상용 뇌정위표적기를 이용하여 두개부내 표적에 대한 모의실험결과 횡단면, 시상면 및 관상면에서 구해진 표적의 위치가 2mm의 오차범위내에서 실제값에 거의 일치함을 얻었다.

  • PDF

3차원 디지털 영상과 CAD/CAM 시스템을 활용한 전악 임플란트 수복 증례 (Full mouth rehabilitation with dental implant utilizing 3D digital image and CAD/CAM system: case report)

  • 강세하;정승미;신재옥;방정환;김대환;최병호
    • 구강회복응용과학지
    • /
    • 제31권2호
    • /
    • pp.158-168
    • /
    • 2015
  • 본 증례는 상 하악 완전 무치악 환자에서 진단, 식립 그리고 보철물 제작에 디지털 방식을 활용하는 방법에 대해 제시하였다. 상악은 구개 부위, 하악은 기존 의치에 방사선 불투과성 마커를 부착한 후 구강스캔 및 CBCT 촬영을 시행하였다. 구강스캔 이미지와 CBCT 이미지를 중첩시켜 진단 및 수술가이드와 임시보철물을 제작하였다. 골유착 후에는 스캔바디를 이용한 구강스캔을 통해 최종보철물을 제작하였다. 임플란트를 이용한 전악수복에서 디지털 방식을 다양하게 활용하였으며 정확성과 환자의 불편감 최소화라는 목적에 만족할만한 결과를 얻었기에 이 증례를 보고하고자 한다.

평행투영 기반의 고해상도 위성영상 에피폴라 재배열 (Epipolar Resampling for High Resolution Satellite Imagery Based on Parallel Projection)

  • 노명종;조우석;장휘정;정지연
    • 대한공간정보학회지
    • /
    • 제15권4호
    • /
    • pp.81-88
    • /
    • 2007
  • 선형 CCD 센서에 의해 획득되는 위성영상의 기하는 프레임 카메라 영상의 기하와는 차이점을 가지고 있다. 이는 각 스캔 선마다 영상의 외부표정요소가 다르기 때문에 발생한다. 따라서 기존의 프레임 영상에 사용되었던 에피폴라 기하와는 다른 기하가 필요하게 된다. 이와 같은 관점에서, 본 연구에서는 대표적인 선형 CCD 센서를 사용하여 촬영된 IKONOS 위성영상을 이용하여 에피폴라 영상을 제작하기 위한 영상 재배열 방법에 대한 연구를 수행하였으며, 영상의 투영조건을 중심투영이 아닌 평행투영으로 간주하여 구성된 2D 부등각 센서모델을 적용하였다. 이센서 모델에 의해 구성된 에피폴라 선식으로부터 유도된 정규 매개변수와 부등각 변환을 적용하여 에피폴라 재배열영상을 제작하였다. 결과로써, 2D 부등각 센서모델의 정확도가 검증되었으며, 제작된 에피폴라 영상을 사용하여 추출된 3차원 위치정확도는 IKONOS의 RFM 위치정확도와 유사하게 도출되었다.

  • PDF

하지기형 교정 수술을 위한 2D-3D 영상 정합기술 (Development of 2D-3D Image Registration Techniques for Corrective Osteotomy for Lower Limbs)

  • 라인찬;봉재환;박신석
    • 한국정밀공학회지
    • /
    • 제30권9호
    • /
    • pp.991-999
    • /
    • 2013
  • Lower limbs deformity is a congenital disease and can also be occurred by an acquired factor. This paper suggests a new technique for surgical planning of Corrective Osteotomy for Lower Limbs (COLL) using 2D-3D medical image registration. Converting to a 3D modeling data of lower limb based on CT (computed tomography) scan, and divide it into femur, tibia and fibula; which composing the lower limb. By rearranging the model based on the biplane 2D images of X-ray data, a 3D upright bone structure was acquired. There are two ways to array the 3D data on the 2D image: Intensity-based registration and feature-based registration. Even though registering Intensity-based method takes more time, this method will provide more precise results, and will improve the accuracy of surgical planning.

3D 이미지 스캔 데이터 기반 SWEEPING 형상 역설계 알고리즘 (3D Image Scan Data-based Sweeping Shape Reconstruction Algorithm)

  • 강태욱
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 춘계학술발표대회
    • /
    • pp.896-897
    • /
    • 2015
  • 본 연구는 3D 이미지 스캔 데이터 기반으로, SWEEPING 형상을 효과적으로 역설계하는 기술에 관한 것이다. 사용자가 미리 정의한 형상 단면 모델 데이터베이스를 이용해, 3차원 SWEEPING 형상을 자동으로 역설계하는 알고리즘을 제안한다. 이를 위해, 3D 이미지 스캔 데이터인 포인트 클라우드에서 자동으로 추출한 단면 포인트들을 처리해, 파라메터 정보를 추출하고, 미리 정의된 형상 단면들과 상호간 유사도를 비교한 후, 가장 유사한 형상 단면을 획득한다. 이러한 기술은 SWEEPING 형상 모델의 역설계 과정을 자동화하는 데 도움을 줄 것이다.

DIR 영상을 이용한 피질두께 측정: GRAPPA 인자 2를 이용한 비교 (Cortical Thickness Estimation Using DIR Imaging with GRAPPA Factor 2)

  • 최나래;남윤호;김동현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권1호
    • /
    • pp.56-63
    • /
    • 2010
  • 목적 : 본 논문에서는 DIR 영상을 이용하여 두뇌의 피질두께측정 연구를 수행하는 한편 평행 영상기법 중 하나인 GRAPPA (generalized autocalibrating partially parallel acquisitions)를 이용하여 GRAPPA 인자 (reduction factor, R)가 2일 때와 평행 영상기법을 이용하지 않았을 때의 결과 비교를 통해 3D DIR 영상의 획득시간 단축 가능성을 제시하고자 한다. 대상 및 방법 : 3.0T 자기공명영상장치 (Siemens Tim Trio MRI scanner)의 3D DIR 펄스열을 이용하여 6명(남자 3명, 여자 3명, $25.33{\pm}2.25$살)의 정상인 뇌에 대한 3차원 영상을 얻었다. GRAPPA 시뮬레이션은 R=2 일 때를 가정하여 수행되었고 두뇌 피질두께측정을 위해 Analyze 9.0과 Freesurfer v.4.3.0 프로그램을 사용하였다. 결과로 얻은 데이터를 T-검증을 이용하여 비교분석 하였다. 결과 : GRAPPA 기법을 통하여 복원한 영상이 잡음이 증가하는 경향을 보였으나 두뇌 피질두께 측정에는 별다른 영향을 미치지 않았다. 통계분석을 통해 비교한 결과 대부분의 두뇌 영역에서 참조영상과 GRAPPA 기법을 이용한 영상의 차이가 유의하지 않았다. 결론 : 피질두께측정 연구에 있어서 3D DIR영상의 문제점 중 하나는 긴 영상획득시간이다. 따라서 평행영상 기법 중 하나인 GRAPPA 영상기법을 적용하면 피질두께측정 연구결과의 큰 차이없이 영상 획득 시간을 단축시킬 수 있다.

휘도와 수직 위치 정보를 이용한 입체 변환 알고리즘 구현 (Implementation of Real-time Stereoscopic Image Conversion Algorithm Using Luminance and Vertical Position)

  • 윤종호;최명렬
    • 한국산학기술학회논문지
    • /
    • 제9권5호
    • /
    • pp.1225-1233
    • /
    • 2008
  • 본 논문은 2D/3D 변환 알고리즘을 제안하였다. 제안된 알고리즘은 2차원 영상의 단일 프레임을 이용한 것으로 실시간 처리가 가능한 알고리즘이다. 제안된 알고리즘은 하나의 프레임에서 객체의 수직 위치 정보를 이용하여 깊이 지도를 생성한다. 실시간 처리와 하드웨어 복잡도를 개선하기 위해 영상 샘플링, 표준 휘도화를 이용한 객체 분할, 그리고 경계 스캔을 이용한 깊이지도 생성 등을 수행하였다. 동영상, 정지영상 모두 적용이 가능하며, 수직 위치 정보를 이용하므로 원거리 영상 혹은 풍경, 파노라마 사진과 같은 영상도 효과적인 입체 효과를 보여줄 수 있다. 제안된 알고리즘은 객체의 움직임 방향 혹은 속도 또는 장면 전환 등에 제약 없이 입체 효과가 가능하다. 제안 알고리즘 검증은 시각적인 방법과 APD(Absolute Parallax Difference)를 이용하여 MTD (Modified Time Difference)방식과의 비교를 수행하였다.

뇌전산화단층검사에서 방사선량 저감을 위한 최적화 프로토콜 연구 (Optimization of Brain Computed Tomography Protocols to Radiation Dose Reduction)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권3호
    • /
    • pp.116-123
    • /
    • 2018
  • This study is a model experimental study using a phantom to propose an optimized brain CT scan protocol that can reduce the radiation dose of a patient and remain quality of image. We investigate the CT scan parameters of brain CT in clinical medical institutions and to measure the important parameters that determine the quality of CT images. We used 52 multislice spiral CT (SOMATOM Definition AS+, Siemens Healthcare, Germany). The scan parameters were tube voltage (kVp), tube current (mAs), scan time, slice thickness, pitch, and scan field of view (SFOV) directly related to the patient's exposure dose. The CT dose indicators were CTDIvol and DLP. The CT images were obtained while increasing the imaging conditions constantly from the phantom limit value (Q1) to the maximum value (Q4) for AAPM CT performance evaluation. And statistics analyzed with Pearson's correlation coefficients. The result of tube voltage that the increase in tube voltage proportionally increases the variation range of the CT number. And similar results were obtained in the qualitative evaluation of the CT image compared to the tube voltage of 120 kVp, which was applied clinically at 100 kVp. Also, the scan conditions were appropriate in the tube current range of 250 mAs to 350 mAs when the tube voltage was 100 kVp. Therefore, by applying the proposed brain CT scanning parameters can be reduced the radiation dose of the patient while maintaining quality of image.