• 제목/요약/키워드: 3D Image Reconstruction

검색결과 591건 처리시간 0.031초

Reconstruction of Head Surface based on Cross Sectional Contours (단면 윤곽선을 기반으로 한 두부표변의 재구성)

  • 한영환;성현경;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • 제18권4호
    • /
    • pp.365-373
    • /
    • 1997
  • In this paper, a new method of the 3D(dimensional) image reconstruction is proposed to build up the 3D image from 2D images using digital image processing techniques and computer graphics. First, the new feature extraction algorithm that doesn't need various input parameters and is not affected by threshold is adopted This new algorithm extracts feature points by eliminating some undesirable points on the ground of the connectivity. Second, as the cast function to reconstruct surfaces using extracted feature points, the minimum distance measure between two plane images has been adopted According to this measure, the surface formation algorithm doesn't need complex calculation and takes the form of triangle or trapezoid To investigate usefulness, this approach has been applied to a head CT image and compared with other methods. Experimental comparisons show that the suggested algorithm yields better performance on feature extraction than others. In contrast with the other methods, the complex calculation for surface formation in the proposed algorithm is not necessary.

  • PDF

Fundamental Matrix Estimation and Key Frame Selection for Full 3D Reconstruction Under Circular Motion (회전 영상에서 기본 행렬 추정 및 키 프레임 선택을 이용한 전방향 3차원 영상 재구성)

  • Kim, Sang-Hoon;Seo, Yung-Ho;Kim, Tae-Eun;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제46권2호
    • /
    • pp.10-23
    • /
    • 2009
  • The fundamental matrix and key frame selection are one of the most important techniques to recover full 3D reconstruction of objects from turntable sequences. This paper proposes a new algorithm that estimates a robust fundamental matrix for camera calibration from uncalibrated images taken under turn-table motion. Single axis turntable motion can be described in terms of its fixed entities. This provides new algorithms for computing the fundamental matrix. From the projective properties of the conics and fundamental matrix the Euclidean 3D coordinates of a point are obtained from geometric locus of the image points trajectories. Experimental results on real and virtual image sequences demonstrate good object reconstructions.

Quantitative Measurements of 3-D Imaging with Computed Tomography using Human Skull Phantom

  • Kim, Dong-Wook;Kim, Hee-Joung;Haijo Jung;Soonil Hong;Yoo, Young-Il;Kim, Dong-Hyeon;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.506-508
    • /
    • 2002
  • As an advancement of medical imaging modalities and analyzing software with multi-function, active researches to acquire high contrast and high resolution image being done. In recently, development of medical imaging modalities like as Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) is aiming to display anatomical structure more accuracy and faster. Thus, one of the important areas in CT today is the use of CT scanner for the quantitative evaluation of 3-D reconstruction images from 2-D tomographic images. In CT system, the effective slice thickness and the quality of 3-D reconstructed image will be influenced by imaging acquisition parameters (e.g. pitch and scan mode). In diagnosis and surgical planning, the accurate distance measurements of 3-D anatomical structures play an important role and the accuracy of distance measurements will depend on the acquisition parameters such as slice thickness, pitch, and scan mode. The skull phantom was scanned with SDCT for various acquisition parameters and acquisition slice thicknesses were 3 and 5 mm, and reconstruction intervals were 1, 2, and 3 mm to each pitch. 3-D visualizations and distance measurements were performed with PC based 3-D rendering and analyzing software. Results showed that the image quality and the measurement accuracy of 3-D SDCT images are independent to the reconstruction intervals and pitches.

  • PDF

User-friendly 3D Object Reconstruction Method based on Structured Light in Ubiquitous Environments (유비쿼터스 환경에서 구조광 기반 사용자 친화적 3차원 객체 재구성 기법)

  • Jung, Sei-Hwa;Lee, Jeongjin
    • The Journal of the Korea Contents Association
    • /
    • 제13권11호
    • /
    • pp.523-532
    • /
    • 2013
  • Since conventional methods for the reconstruction of 3D objects used a number of cameras or pictures, they required specific hardwares or they were sensitive to the photography environment with a lot of processing time. In this paper, we propose a 3D object reconstruction method using one photograph based on structured light in ubiquitous environments. We use color pattern of the conventional method for structured light. In this paper, we propose a novel pipeline consisting of various image processing techniques for line pattern extraction and matching, which are very important for the performance of the object reconstruction. And we propose the optimal cost function for the pattern matching. Using our method, it is possible to reconstruct a 3D object with efficient computation and easy setting in ubiquitous or mobile environments, for example, a smartphone with a subminiature projector like Galaxy Beam.

Evaluation of Knee Joint after Double-Bundle ACL Reconstruction with Three-Dimensional Isotropic MRI

  • Jung, Min ju;Jeong, Yu Mi;Lee, Beom Goo;Sim, Jae Ang;Choi, Hye-Young;Kim, Jeong Ho;Lee, Sheen-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.95-104
    • /
    • 2016
  • Purpose: To evaluate the knee joint after double-bundle anterior cruciate ligament (ACL) reconstruction with three-dimensional (3D) isotropic magnetic resonance (MR) image, and to directly compare the ACL graft findings on 3D MR with the clinical results. Materials and Methods: From January 2009 to December 2014, we retrospectively reviewed MRIs of 39 patients who had reconstructed ACL with double bundle technique. The subjects were examined using 3D isotropic proton-density sequence and routine two-dimensional (2D) sequence on 3.0T scanner. The MR images were qualitatively evaluated for the intraarticular curvature, graft tear, bony impingement, intraosseous tunnel cyst, and synovitis of anteromedial and posterolateral bundles (AMB, PLB). In addition anterior tibial translation, PCL angle, PCL ratio were quantitatively measured. KT arthrometric values were reviewed for anterior tibial translation as positive or negative. The second look arthroscopy results including tear and laxity were reviewed. Results: Significant correlations were found between an AMB tear on 3D-isotropic proton density MR images and arthroscopic proven AMB tear or laxity (P < 0.05). Also, a significant correlation was observed between increased PCL ratio on 3D isotropic MRI and the arthroscopic findings such as tear, laxities of grafts (P < 0.05). KT arthrometric results were found to be significantly correlated with AMB tears (P < 0.05) and tibial tunnel cysts (P < 0.05). Conclusion: An AMB tear on 3D-isotropic MRI was correlated with arthroscopic results qualitatively and quantitatively. 3D isotropic MRI findings can aid the evaluation of ACL grafts after double bundle reconstruction.

3D Microwave Imaging Technology for Damage Detection of Concrete Structures (콘크리트 구조물의 결함발견을 위한 3차원 초단파 영상처리기법의 개발)

  • Kim, Yoo-Jin;Kim, Yong-Gon
    • Journal of the Korean Society of Safety
    • /
    • 제18권4호
    • /
    • pp.98-104
    • /
    • 2003
  • Various nondestructive evaluation (NDE) techniques have been studied to locate steel rebars of dowel, and to detect invisible damage such as voids and cracks inside concrete and debonding between rebars and concrete caused by corrosions and earthquakes. In this study, the aurhors developed 3-dimensional (3D) electromagnetic (EM) imaging technology to detect such damage and to identify exact location of steel rebars of dowel. The authors have developed sub-surface two-dimensional (2D) imaging technique using tomographic antenna array in previous works. In this study, extending the earlier analytical and experimental works on 2D image reconstruction, a 3D microwave imaging system using tomographic antenna array was developed, and multi-frequency technique was applied to improve quality of the reconstructed image and to reduce background noises. This paper presents the analytical expressions of numerical focusing procedures for 3D image reconstruction and numerical simulation to study the resolution of the system and the effectiveness of multi-frequency technique. Also, the design of 4?4 antenna array with switching devices is introduced as a preliminary study for the final design of whole array.

The Measurement of Size of the Pedicle Using 3 Dimensional Reconstruction Image in Idiopathic Scoliosis (특발성 척추측만증 환자에서의 3차원적 재구성을 이용한 척추경의 크기 측정)

  • Heo, Jae-Hee;Ahn, Myun-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • 제21권1호
    • /
    • pp.40-50
    • /
    • 2004
  • Background: This study was conducted to analyze the height and width of the pedicle of the upper and lower levels on the concave and the convex sides. In addition, we checked for the appropriate pedicle screw size which could be screwed in without complications. Materials and Methods: Taking a simple AP radiography in a standing position, 99 vertebrae on the major curve with the possibility of 3-D reconstruction were analyzed after checking the CT in a supine position of 22 idiopathic scoliosis. We measured Cobb's angle from a simple radiograph, and measured the size of the isthmus by the Inner Space 3-D Editor after 3-D reconstruction with the Inner Space 3-D program in the DICOM file transformed from CT image. We then analyzed the size of pedicles of the upper and lower levels on the concave and the convex sides by measuring the height and width of the pedicle. Results: All pedicles on the concave side were smaller than those on the convex side. Their size increased as the measurement moved from the upper to lower vertebra, except for the upper thoracic vertebra. When the width of the pedicle through 3-D reconstruction was compared with the narrowest width of the pedicle measured by using CT, the width of the pedicles through 3-D reconstruction was statistically smaller (P<0.01). Most of the pedicles were tear-drop or kidney shaped rather than cylindrical. Conclusion: These results suggest that the use of the coronal plane through 3-D reconstruction would be necessary for an accurate measurement of the size of the pedicle. It is important to pay careful attention to the screw size and the screwing method considering the pedicle shape through 3-D reconstruction.

  • PDF

Computational integral imaging reconstruction by use of scale-variant magnification technique

  • Shin, Dong-Hak;Yoo, Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.726-729
    • /
    • 2008
  • In this paper, we present an interference problem among elemental images in computational integral imaging reconstruction. To overcome the interference problem, we propose a method to calculate a minimum magnification factor and the preliminary experiments are performed.

  • PDF

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제13권1호
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

A Study on the Voxel Mesh Technique for Finite Element Modeling of Human Bone (인체 골(bone)의 유한요소 모델링을 위한 VOXEL MESH 기법에 관한 연구)

  • 변창환;오택열;백승민;채경덕
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1081-1084
    • /
    • 2002
  • In this study, we perform 3-D reconstruction of human proximal femur from DICOM files by using voxel mesh algorithm. After 3-D reconstruction, the model converted to Finite Element model which developed for automatically making not only 3-D geometrical model but also FE model from medical image dataset. During this job, trabecular pattern, one of characteristic of human bone can be added to the model by means of giving it's own elastic property calculated from intensity in CT scanned image to the each voxel. And then another model is made from same image dataset which have two material properties - one corresponds to cortical bone, another to trabecular bone. Finally, validity of voxel mesh technique is verified through comparing results of FE analysis, free vibration and stress analysis.

  • PDF