• Title/Summary/Keyword: 3D File Format

Search Result 87, Processing Time 0.022 seconds

Web-Based 3D Model Management System for Virtual Training Contents Production (가상훈련 컨텐츠 제작을 위한 웹 기반 3D 모델 관리 시스템)

  • Kim, Yeon-U;Yoon, Ji-Yean;Kang, Hyeong-Ju
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.4 no.1
    • /
    • pp.72-79
    • /
    • 2012
  • Recently, the growth of the computer-related industries lead to the growth of the computer-aided education. Virtual training (VT) is one of the most interesting education methods. Many 3D models for the VT contents have been produced, but little research has been performed for the unified management system to promote the reuse of 3D models. This paper proposes the unified 3D model management system. The 3D model file formats are surveyed to find a format that can be easily used by many VT content production softwares. The 3D model files will be stored in a central DB server. The structure of the DB system will be designed for 3D models. The system provides an easy way to search and download a 3D model. With the proposed system, the reuse of 3D models is expected to be promoted.

  • PDF

State-of-the-art 3D GIS: System Development Perspectives

  • Kim, Kyong-Ho;Lee, Ki-Won;Lee, Jong-Hun;Yang, Young-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.153-158
    • /
    • 1998
  • Since the mid-1990′s, researches on 3D GIS have been regarded as one of main issues both in the academic sites and commercial vendors; recently, some prototyped systems or the first versioned software systems of commercial basis are being reported and released. Unlike conventional 2D GIS, which consists in intelligent structured GIS or desktop GIS, every 3D GIS has its own distinguished features according to data structure-supporting capability, GIS-styled functionality, external database accessibility, interfacing extents with 2D GIS, 3D visualization/texture mapping ability, and so forth. In this study, technical aspects related to system development, SERI-Web3D GIS ver. 1.2, are explained. Main features in this revised 3D GIS can be summarized: 2-tier system model(client-server), VGFF(Virtual GIS File Format), internal GIS import, Feature manager(zoning, layering, visualization evironment), Scene manager(manage 3D geographic world), Scene editor, Spatial analyzer(Intersect, Buffering, Network analysis), VRML exporter. While, most other 3D GISes or cartographic mapping systems may be categorized into 3D visualization systems handling terrain height-field processing, 2D GIS extension modules, or 3D geometric feature generation system using orthophoto image: actually, these are eventually considered as several parts of "real 3D GIS". As well as these things, other components, especially web-based 3D GIS, are being implemented in this study: Surface/feature integration, Java/VRML linkage, Mesh/Grid problem, LOD(Level of Detail)/Tiling, Public access security problem, 3-tier architecture extension, Surface handling strategy for VRML.

  • PDF

A Study on Constant-Speed Position Control of Solid Freeform Fabrication System (임의형상가공시스템의 정속위치제어)

  • Jung, Yong-Rae;Ko, Min-Kook;Kim, Seung-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.75-78
    • /
    • 2002
  • SFFS(Solid Freeform Fabrication System) is commercializing to rapid prototyping concept in world-wide some corporations including the States, have much technological problems yet and need new mode for agile solid freeform fabrication as well as prototyping. In this paper, we design an automatic control algorithm that the cutting path of laser beam, on the SFFS, is controlled with constant speed. The designed algorithm for constant-speed path control is implemented and experimented in the $CAFL^{VM}$ (Computer Aided Fabrication of Lamination for Various Material) system, the new SFFS which is developed in this paper. Its process is an automated fabrication method in which a 3D object is constructed from STL(SToreoLithography) 2D data, derived from CAD 3D image, by sequentially laminating the part cross-sections. The constant-speed path control is started from the STL data. After STL file is modified in data format to be available for control. The fabrication of the 2D part is, with constant speed, conducted from the 23 position data by laser beam. we confirm its high-performance through experiment results from the application into $CAFL^{VM}$ system.

  • PDF

TAH(Total Artificial Heart) Virtual Surgery Using Multi-Volume Visualizing Technique (다중 체적 가시 기법을 이용한 완전인공심장의 가상 수술)

  • Lee, D.H.;Kim, J.H.;Kim, N.K.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.587-589
    • /
    • 1997
  • The virtual surgical trial of TAH is very important in some points as follows. The chests of patients who is under heart-disease are various types of undefine form. It is hard to say that there exist the standard shape of TAH and the position to surgern. So, the virtual surgery system is very important in realizing TAH surgery of human. We have implemented virtual surgery system of TAH that supporting multi volume fitting trial. We have acquired CT images of patients with DICOM format. Each organ of patients was segmented in 2-dimensional CT images. 3-dimensional objects were made with marching cube algorithm and save as file in VRML format. Virtual fitting trial was performed on Cosmo-World; a VRML editor. The collision points of TAH with other organs were well observed. And the best position and angles were determined and saved or each case. We believed that this virtual surgery will be helpful in TAH surgery and TAH customizing.

  • PDF

Specification of VRML in Color Rapid Prototyping

  • Ming, Ling Wai;Gibson, Ian
    • International Journal of CAD/CAM
    • /
    • v.1 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • The STL or Stereolithography format, established by 3D systems, gathers the geometric data of the model in a number of triangular surfaces. It can be in ASCII or binary format, and is a de facto standard in the Rapid Prototyping (RP) world. RP has developed greatly over the last ten years. In particular, improvement in materials has meant greater part accuracy and strength, which in turn has increased the range of functional applications. Future applications of RP will focus on rapid tooling and direct manufacturing. Direct manufacturing in particular may see much benefit from the incorporation of color into models. For color RP, besides designing new hardware to add color into the prototypes, it is necessary to redefine the CAD software for adding and accurately positioning color onto the model. STL cannot effectively store this kind of information. Among the existing data file formats, VRML is an acceptable one that is complimentary to existing RP processes. This paper acts as a review to discuss several methods of using VRML for coloring model data. This paper will also discuss the problems occurred in coloring the layer contours of the RP model.

Automatic real-time system of the global 3-D MHD model: Description and initial tests

  • Park, Geun-Seok;Choi, Seong-Hwan;Cho, Il-Hyun;Baek, Ji-Hye;Park, Kyung-Sun;Cho, Kyung-Suk;Choe, Gwang-Son
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.26.2-26.2
    • /
    • 2009
  • The Solar and Space Weather Research Group (SOS) in Korea Astronomy and Space Science Institute (KASI) is constructing the Space Weather Prediction Center since 2007. As a part of the project, we are developing automatic real-time system of the global 3-D magnetohydrodynamics (MHD) simulation. The MHD simulation model of earth's magnetosphere is designed as modified leap-frog scheme by T. Ogino, and it was parallelized by using message passing interface (MPI). Our work focuses on the automatic processing about simulation of 3-D MHD model and visualization of the simulation results. We used PC cluster to compute, and virtual reality modeling language (VRML) file format to visualize the MHD simulation. The system can show the variation of earth's magnetosphere by the solar wind in quasi real time. For data assimilation we used four parameters from ACE data; density, pressure, velocity of solar wind, and z component of interplanetary magnetic field (IMF). In this paper, we performed some initial tests and made a animation. The automatic real-time system will be valuable tool to understand the configuration of the solar-terrestrial environment for space weather research.

  • PDF

MIMS: Web-based Micro Machining Service (MIMS: 웹기반 마이크로 머시닝 서비스)

  • Chu W.-S.;Ahn S.-H.;Kim D.-S.;Jun C.-S.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.9 no.3
    • /
    • pp.246-252
    • /
    • 2004
  • Presented in this Paper is a Micro Machining Service .(MIMS) based on the World Wide Web technologies. In order to ensure easy access to the service, the web browsers are used as the user interface. The pan geometry as an STL file is uploaded with process parameter for 3-axis CNC milling. Depending on the predefined user level, novice or expert, the user interface requires different parameters for process planning. An STL-based CAM resides in the server and automatically provides NC codes upon user's request. Tool-paths for scanning and pencil-cut, which are interference-free and precise, are created by the curve-based polyhedral machining method. A couple of sample parts were fabricated by a micro endmill with 127 fm diameter. From the tests, the parts fabricated by scanning followed by pencil-cut resulted in less error(within 2%) than the parts machined only by scanning tool-path.

A Study on Virtual Reality Management of 3D Image Information using High-Speed Information Network (초고속 정보통신망을 통한 3차원 영상 정보의 가상현실 관리에 관한 연구)

  • Kim, Jin-Ho;Kim, Jee-In;Chang, Chun-Hyon;Song, Sang-Hoon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.12
    • /
    • pp.3275-3284
    • /
    • 1998
  • In this paper, we deseribe a Medical Image Information System. Our system stores and manages 5 dimensional medical image data and provides the 3 dimensional medical data via the Internet. The Internet standard VR format. VRML(Virtual Reality Modeling Language) is used to represent the 3I) medical image data. The 3D images are reconstructed from medical image data which are enerated by medical imaging systems such ans CT(Computerized Tomography). MRI(Magnetic Resonance Imaging). PET(Positron Emission Tomograph), SPECT(Single Photon Emission Compated Tomography). We implemented the medical image information system shich rses a surface-based rendering method for the econstruction of 3D images from 2D medical image data. In order to reduce the size of image files to be transfered via the Internet. The system can reduce more than 50% for the triangles which represent the surfaces of the generated 3D medical images. When we compress the 3D image file, the size of the file can be redued more than 80%. The users can promptly retrieve 3D medical image data through the Internet and view the 3D medical images without a graphical acceleration card, because the images are represented in VRML. The image data are generated by various types of medical imaging systems such as CT, MRI, PET, and SPECT. Our system can display those different types of medical images in the 2D and the 3D formats. The patient information and the diagnostic information are also provided by the system. The system can be used to implement the "Tele medicaine" systems.

  • PDF

An Efficient Method for Aneurysm Volume Quantification Applicable in Any Shape and Modalities

  • Chung, Jaewoo;Ko, Jung Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.514-523
    • /
    • 2021
  • Objective : Aneurysm volume quantification (AVQ) using the equation of ellipsoid volume is widely used although it is inaccurate. Furthermore, AVQ with 3-dimensional (3D) rendered data has limitations in general use. A novel universal method for AVQ is introduced for any diagnostic modality and application to any shape of aneurysms. Methods : Relevant AVQ studies published from January 1997 to June 2019 were identified to determine common methods of AVQ. The basic idea is to eliminate the normal artery volume from 3D model with the aneurysm. After Digital Imaging and Communications in Medicine (DICOM) data is converted and exported to stereolithography (STL) file format, the 3D STL model is modified to remove the aneurysm and the volume difference between the 3D model with/without the aneurysm is defined as the aneurysm volume. Fifty randomly selected aneurysms from DICOM database were used to validate the different AVQ methods. Results : We reviewed and categorized AVQ methods in 121 studies. Approximately 60% used the ellipsoid method, while 24% used the 3D model. For 50 randomly selected aneurysms, volumes were measured using 3D Slicer, RadiAnt, and ellipsoid method. Using 3D Slicer as the reference, the ratios of mean difference to mean volume obtained by RadiAnt and ellipsoid method were -1.21±7.46% and 4.04±30.54%, respectively. The deviations between RadiAnt and 3D Slicer were small despite of aneurysm shapes, but those of ellipsoid method and 3D Slicer were large. Conclusion : In spite of inaccuracy, ellipsoid method is still mostly used. We propose a novel universal method for AVQ that is valid, low cost, and easy to use.

Analysis of Building Energy using Automated Weather System Data (자동 기상관측 자료를 이용한 건축물 에너지 분석)

  • Lee, Kwi-Ok;Kang, Dong-Bae;Lee, Kang-Yoel;Jung, Woo-Sik;Sim, Je-Hean;Yoon, Seong-Hwan
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.493-502
    • /
    • 2014
  • EnergyPlus is a whole building energy simulation program that engineers, architects, and researchers use to model energy and water use in buildings. Modeling the performance of a building with EnergyPlus enables building professionals to optimize the building design to use less energy and water. This program provides energy analysis of building and needs weather data for simulation. Weather data is available for over 2,000 locations in a file format that can be read by EnergyPlus. However, only five locations are avaliable in Korea. This study intends to use AWS data for having high spatial resolution to simulate building energy. The result of this study shows the possibility of using AWS data for energy simulation of building.