• Title/Summary/Keyword: 3D Digital

Search Result 3,383, Processing Time 0.026 seconds

Concha bullosa, nasal septal deviation, and their impacts on maxillary sinus volume among Emirati people: A cone-beam computed tomography study

  • Al-Rawi, Natheer H;Uthman, Asmaa T;Abdulhameed, Elaf;Al Nuaimi, Ahmed S;Seraj, Zahra
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.45-51
    • /
    • 2019
  • Purpose: To determine the prevalence of concha bullosa (CB) and nasal septal deviation (NSD) and their impact on maxillary sinus volume (MSV). Materials and Methods: Cone-beam computed tomographic (CBCT) images of 106 Emirati people were used in this study. The direction and angle of septal deviation were calculated. The presence of CB, which could be unilateral, contralateral, or bilateral in relation to the direction of NSD, was also recorded. MSV was measured using reconstructed Digital Imaging and Communication in Medicine images on Dolphin 3D imaging software version 11.8 premium (Dolphin Imaging, Chatsworth, CA, USA). P values<0.05 were considered to indicate statistical significance. Results: CB was detected in 37.7% of the sample; 20.7% of the sample showed single unilateral CB and 16.6% had single bilateral CB. NSD was seen in 74.5% of the sample. In the participants with CB, 45.5% showed mild deviation, 34.4% showed moderate deviation, and only 12.5% showed severe septal deviation. CB, but not NSD, was associated with significantly higher MSV on the affected side (P=0.001). Conclusion: Although NSD was observed in more than two-thirds of the sample and CB was present in more than one-third of the sample, only CB had a significant impact on MSV.

Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

  • Lee, Suji;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.55-64
    • /
    • 2019
  • PURPOSE. The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS. The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at ${\alpha}=.05$. RESULTS. No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION. The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

Developing Experiential Exhibitions Based on Conservation Science Content of Bronze Mirror

  • Jo, Young Hoon;Kim, Jikio;Yun, Yong Hyun;Cho, Nam Chul;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.37 no.4
    • /
    • pp.362-369
    • /
    • 2021
  • In museums, exhibition content focuses mostly on cultural heritage's historical values and functions, but doing so tends to limit visitors' interest and immersion. To counter this limitation, the study developed an experiential media art exhibition fusing bronze mirrors' traditional production technology and modern conservation science. First, for the exhibition system, scientific cultural heritage contents were projected on the three-dimensional (3D) printed bronze mirror through interactions between motion recognition digital information display (DID) and the projector. Then, a scenario of 17 missions in four stages (production process, corrosion mechanism, scientific analysis and diagnosis, and conservation treatment and restoration) was prepared according to the temporal spectrum. Additionally, various media art effects and interaction technologies were developed, so visitors could understand and become immersed in bronze mirrors' scientific content. A user test was evaluated through the living lab, reflecting generally high levels of satisfaction (90.2 points). Qualitative evaluation was generally positive, with comments such as "easy to understand and useful as the esoteric science exhibition was combined with media art" (16.7%), "wonderful and interesting" (11.7%), and "firsthand experience was good" (9.2%). By combining an esoteric science exhibition centered on principles and theories with visual media art and by developing an immersive directing method to provide high-level exhibition technology, the exhibition induced visitors' active participation. This exhibition's content can become an important platform for expanding universal museum exhibitions on archaeology, history, and art into conservation science.

Development of Curing Process for EMC Encapsulation of Ultra-thin Semiconductor Package (초박형 반도체 패키지의 EMC encapsulation을 위한 경화 공정 개발)

  • Park, Seong Yeon;On, Seung Yoon;Kim, Seong Su
    • Composites Research
    • /
    • v.34 no.1
    • /
    • pp.47-50
    • /
    • 2021
  • In this paper, the Curing process for Epoxy Molding Compound (EMC) Package was developed by comparing the performance of the EMC/Cu Bi-layer package manufactured by the conventional Hot Press process system and Carbon Nanotubes (CNT) Heater process system of the surface heating system. The viscosity of EMC was measured by using a rheometer for the curing cycle of the CNT Heater. In the EMC/Cu Bi-layer Package manufactured through the two process methods by mentioned above, the voids inside the EMC was analyzed using an optical microscope. In addition, the interfacial void and warpage of the EMC/Cu Bi-layer Package were analyzed through C-Scanning Acoustic Microscope and 3D-Digital Image Correlation. According to these experimental results, it was confirmed that there was neither void in the EMC interior nor difference in the warpage at room temperature, the zero-warpage temperature and the change in warpage.

Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer (DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

A study on the improvement of seamless knitwear sleeve design (무봉제 니트웨어의 소매디자인 향상을 위한 연구)

  • Kang, Hee Myung;Ki, Hee-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.23 no.4
    • /
    • pp.57-71
    • /
    • 2021
  • The purpose of the study is to derive an appropriate knitting method that can increase the appearance, wearability, and functionality through empirical research on the sleeve height knitting ratio of seamless knit wear. The study was conducted by producing seven types of experiment clothes according to knitting ratio to examine the characteristics according to the body armhole and sleeve height ratio. Specifically, after fit evaluatins, variance analysis (ANOVA) was performed to analyze the results of the evaluation, and the evaluated contents were converted into data. Among them, the items with significant results were intensively studied using the Duncan-test. The result showed that the height and the width of the sleeves vary depending on the knitting ratio. Test sweater A was the highest at 16cm, followed by test sweater B, test sweater C, test sweater D, test sweater E, test sweater F, and test sweater G at 4cm. The 1:1 ratio of test sweater A, was the highest, which is knitted in the same course as the body. The larger the difference in the ratio of body and sleeve, the lower the height of the sleeves. As a result of the appearance sensory evaluation, a significant difference was confirmed in the result values (p<0.001) from all items on the front, side, and rear. Specifically, the appearance of the test sweater B(2:4:2) on the front and test sweater C(2:4:3) on the side and rear side was the best. When the sleeves height is properly set, the ratio of the arm line to fit the design with a natural curve is analyzed as a very important factor. The results of this study are expected to be of practical use in product development and production that can increase the feeling when wearing and design satisfaction.

Evaluation of Nutritional Quality of Convenience Store Meal Boxes according to Store Company and Meal Price (편의점 기업과 도시락 가격에 따른 편의점 도시락의 영양학적 질 평가)

  • Cho, Changgyu;Nam, Youngmin;Yoo, Hye-Jong
    • Korean Journal of Community Nutrition
    • /
    • v.27 no.2
    • /
    • pp.105-120
    • /
    • 2022
  • Objectives: This study evaluated nutritional quality of convenience store meal boxes according to store company and meal price. Methods: In May 2020, 71 meal boxes from five major convenience store companies were collected. Respective weights of all dishes and food ingredients included in each meal box were measured with a digital scale. Information on nutritional contents was collected from nutrition fact panels on packages. Food group patterns, dietary diversity scores (DDS), and dietary variety scores (DVS) were analyzed. Nutritional contents, i.e., amounts of energy, protein, and sodium, and percentages of energy from carbohydrate, sugar, fat, and saturated fat were compared with respective standards based on the 2020 Dietary Reference Intakes for Koreans. Comparison was made among five companies (Company A, B, C, D, E) and three price groups (≦ 4,200 won, ≧ 4,300 and ≦ 4,500 won, ≧ 4,600 won). Multiple regression analyses were conducted to examine the difference of nutritional contents according to company and price, respectively while holding the other variable constant. Results: DDS, but not DVS, significantly differed among companies. The percentages of meal boxes meeting the nutritional standards of sodium significantly differed among companies; the percentage was highest in companies B (75.0%) and C (73.3%). "Company" was associated with amount of energy, protein, and sodium, and percentage of energy from saturated fat. "Price" was associated with the amount of energy and percentage of energy from carbohydrate. The average number of satisfied standards was highest in companies B (5.0) and C (4.0). About two-thirds of the meal boxes provided less amount of energy than the standard; the percentage of such meal boxes was highest in meal boxes with price of 4,200 won or lower. Conclusions: There were significant differences in the nutritional quality of meal boxes according to "company". Meanwhile, higher-priced meal boxes did not necessarily ensure better nutritional quality.

Caenimonas aquaedulcis sp. nov., Isolated from Freshwater of Daechung Reservoir during Microcystis Bloom

  • Le, Ve Van;Ko, So-Ra;Lee, Sang-Ah;Kang, Mingyeong;Oh, Hee-Mock;Ahn, Chi-Yong
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.5
    • /
    • pp.575-581
    • /
    • 2022
  • A Gram-stain-negative, white-coloured, and rod-shaped bacterium, strain DR4-4T, was isolated from Daechung Reservoir, Republic of Korea, during Microcystis bloom. Strain DR4-4T was most closely related to Caenimonas terrae SGM1-15T and Caenimonas koreensis EMB320T with 98.1% 16S rRNA gene sequence similarities. The average nucleotide identity (ANI) and digital DNA-DNA hybridization (dDDH) values between strain DR4-4T and closely related type strains were below 79.46% and 22.30%, respectively. The genomic DNA G+C content was 67.5%. The major cellular fatty acids (≥10% of the total) were identified as C16:0, cyclo C17:0, summed feature 3 (C16:1ω7c and/or C16:1ω6c), and summed feature 8 (C18:1ω7c and/or C18:1ω6c). Strain DR4-4T possessed phosphatidylethanolamine, diphosphatidylglycerol, and phosphatidylglycerol as the main polar lipids and Q-8 as the respiratory quinone. The polyamine profile was composed of putrescine, cadaverine, and spermidine. The results of polyphasic characterization indicated that the isolated strain DR4-4T represents a novel species within the genus Caenimonas, for which the name Caenimonas aquaedulcis sp. nov. is proposed. The type strain is DR4-4T (=KCTC 82470T =JCM 34453T).

Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: a pilot study

  • Iturrate, Mikel;Amezua, Xabier;Garikano, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.191-204
    • /
    • 2021
  • PURPOSE. The purpose of this study is to present a methodology to evaluate the accuracy of intraoral scanners (IOS) used in vivo. MATERIALS AND METHODS. A specific feature-based gauge was designed, manufactured, and measured in a coordinate measuring machine (CMM), obtaining reference distances and angles. Then, 10 scans were taken by an IOS with the gauge in the patient's mouth and from the obtained stereolithography (STL) files, a total of 40 distances and 150 angles were measured and compared with the gauge's reference values. In order to provide a comparison, there were defined distance and angle groups in accordance with the increasing scanning area: from a short span area to a complete-arch scanning extension. Data was analyzed using software for statistical analysis. RESULTS. Deviations in measured distances showed that accuracy worsened as the scanning area increased: trueness varied from 0.018 ± 0.021 mm in a distance equivalent to the space spanning a four-unit bridge to 0.106 ± 0.08 mm in a space equivalent to a complete arch. Precision ranged from 0.015 ± 0.03 mm to 0.077 ± 0.073 mm in the same two areas. When analyzing angles, deviations did not show such a worsening pattern. In addition, deviations in angle measurement values were low and there were no calculated significant differences among angle groups. CONCLUSION. Currently, there is no standardized procedure to assess the accuracy of IOS in vivo, and the results show that the proposed methodology can contribute to this purpose. The deviations measured in the study show a worsening accuracy when increasing the length of the scanning area.

Simulation of the Stiffness of HTPE Fabric according to the Application of Reactive Pigment DTP Process and Dyeability (반응성 안료의 DTP공정 적용에 따른 HTPE원단의 태 시뮬레이션 및 염색성 연구)

  • Sim, Jee-hyun;Lee, Jong-hyuk;Yu, Seong-Hun;Gwon, Gi-Hwan;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.33 no.4
    • /
    • pp.210-219
    • /
    • 2021
  • It was intended to conduct basic research to reduce development lead time and cost consumed in DTP process technology development. For the simulation of HTPE fabric, virtual engineering software was used to generate fiber model, yarn model, fabric model, and finite element model of HTPE fiber. The purpose of this study is to analyze the correlation and error rate between the stiffness numerical analysis results according to the direct DTP process parameters using reactive dyes in the generated finite element model and the stiffness measurements of the actual sample ac- cording to ASTM D1388. And, after dyeing the HTPE plain fabric according to the direct DTP process parameters, we want to analyze the dyeability of the HTPE fabric fabrics according to the direct DTP process parameters through the color fastness analysis. When looking at the results of the analysis of the finite element model, a higher value was shown when the distance between the nozzle and the fabric was 3mm than when the distance was 10mm. When the distance between the nozzle and the fabric was 10mm and 7mm, the reactive dye did not penetrate sufficiently, resulting in poor clarity when viewed with the naked eye.