• Title/Summary/Keyword: 3D DCT

Search Result 110, Processing Time 0.028 seconds

Relation of Expression Levels of Melanin Synthesis Genes according to the MC1R Genotypes with the Coat Color Patterns in Hanwoo, Jeju Black Cattle and Holstein (한우와 제주흑우, 홀스타인에서 MC1R 유전자형에 따른 melanin 생합성 유전자들의 발현수준과 모색 출현양상의 관계)

  • Lee, Sung-Soo;Yang, Young-Hoon;Cho, In-Cheol;Kim, Nam-Young;Ko, Moon-Suck;Jung, Ha-Yeon;Han, Sang-Hyun
    • Journal of Life Science
    • /
    • v.19 no.3
    • /
    • pp.384-389
    • /
    • 2009
  • This study was carried out to elucidate the relation between expression levels of three melanin synthesis genes (Tyrosinase, Tyrosinase-related protein 1 and Dopachrome tautomerase) according to the Melanocortin-1 receptor genotypes with coat color patterns in Hanwoo cattle, Jeju black cattle and Holsteins. Using real-time semiquantitative reverse transcription-PCR assay (RT-PCR), the expression levels of these three genes were analyzed in skin tissues from four representative coat colored areas: yellowish-brown from MC1R e/e Hanwoo, wild type black from $E^+/E^+$ Jeju black cattle (JBC), and dominant black and white pied regions from $E^D/E^D$ Holstein. The TYR, TYRP1 and DCT genes showed higher expression levels of 4.5, 2.3 and 2.5 times higher in the black skin area of Holsteins than those of from JBC, respectively (p<0.001). In addition, the expression levels of these three genes from JBC were significantly higher than those from Hanwoo cattle (p<0.001). These results show that coat color phenotypes in Hanwoo cattle, JBC and Holsteins is directly correlated with TRY, TYRP1 and DCT transcription levels, which probably reflected involvement with MC1R genotypes; e/e in Hanwoo, $E^+/E^+$ in JBC and $E^D/E^D$ in Holsteins. Consequently, this study suggested that the status of MC1R protein may not only induce the transcription activities of a series of TYR and its related genes responsible for melanin synthesis, but also determine the levels of total melanin contents in bovine skin.

An Efficient Coding Technique of Holographic Video Signal using 3D Segment Scanning (분할영역의 3차원 스캐닝을 이용한 홀로그래픽 비디오 신호의 효율적인 부호화 기술)

  • Seo, Young-Ho;Choi, Hyun-Jun;Kim, Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2C
    • /
    • pp.132-140
    • /
    • 2007
  • In this paper, we proposed a new technique to encode and decode the digital hologram. Since the digital hologram (or fringe pattern) is generated by interference of light, it has much different property from natural 2D (2 dimensional) images. First, we acquisite optical-sensed or computer-generated hologram by digital type, and then extract a chrominance component. The extracted digital hologram for coding is separated into segments to use multi-view properties. The segmented hologram shows the similar characteristics with picturing an object with 2D cameras in various point of view. Since fringe pattern is visually observed like as noise, we expect that the fringe pattern has poor coding efficiency. To obtain high efficiency, the segment is transformed with DCT (Discrete Cosine Transform) which resembles hologram generation process with high performance. Each transformed segment passes the 3D scanning process according to time and spatial correlation, and is organized into a video stream. Since the segment which correspond to frame of a video stream consists of the transformed coefficients with wide range of value, it is classified and re-normalized. Finally it is compressed with coding tools. The proposed algorithm illustrated that it has better properties for reconstruction of 16 times higher compression rate than the previous researches.

Error-Resilience Enhancement based on Polyphase Down Sampling for the H.264 Video Coding Technology (에러 강인성 향상을 위한 다상 다운 샘플링 적용 H.264 동영상 부호화 기술)

  • Jung, Eun Ku;Jia, Jie;Kim, Hae Kwang;Choi, Hae Chul;Kim, Jae Gon
    • Journal of Broadcast Engineering
    • /
    • v.10 no.3
    • /
    • pp.340-347
    • /
    • 2005
  • This paper presents a polyphase down sampling based multiple description coding applied to H.264 video coding standard. For a given macroblock, a residual macroblock is calculated by motion estimation, and before applying DCT, quantization and entrophy coding of the H.264 coding process, the polyphase down sampling is applied to the residual macroblock to code in four separate descriptions. Experiments were performed for all the 9 test sequences of JVT SVC standardization in various packet loss patterns. Experimental results show that the proposed one gives 0.5 to 5 dB enhancement over an error-concealment based on the slice group map technolgoy.

A Collusion-secure Fingerprinting Scheme for Three-dimensional Mesh Models (삼차원 메쉬 모델에 적용한 공모방지 핑거프린팅 기법)

  • Hur, Yung;Jeon, Jeong-Hee;Ho, Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.4
    • /
    • pp.113-123
    • /
    • 2004
  • This paper presents a new collusion-secure fingerprinting scheme to embed fingerprints into three-dimensional(3-D) mesh models efficiently. In the proposed scheme, we make the same number of fingerprints as the number of customers based on the finite projective geometry, partition a 3-D mesh model related to the number of bits assigned to each fingerprint and then embed a watermark representing copyright information into each submesh to be marked. Considering imperceptibility and robustness of the watermarking algorithm we embed the watermark signal into mid-frequency DCT coefficients obtained by transforming vertex coordinates in the triangle strips which are generated from the submeshes to be marked. Experimental results show that our scheme is robust to additive random noises, MPEG-4 SNHC 3-D mesh coding, geometrical transformations, and fingerprint attacks by two traitors' collusion. In addition, we can reduce the number of bits assigned to each fingerprint significantly.

Hierachical 3-D Shape Reconstruction from Shading Using Genetic Algorithm (유전자 알고리즘을 이용한 밝기 정보로부터 3차원 표면 형상의 재구성)

  • 안은영;박현남;조형제
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10c
    • /
    • pp.476-478
    • /
    • 1998
  • 본 논문에서는 영상의 밝기 정보로부터 물체의 표면 형상을 재구성하는 새로운 접근 방법을 제시한다. 이미지 모델은 기존의 Lambertian surface model에 거리 요소를 포함시켜 보다 현실과 비슷한 제약 조건을 주고, 국지 해(local minima)에 빠지기 쉬운 기존의 iteration 방법을 탈피하기 위해 유전자 알고리즘(genetic algorithm)을 도입한다. 표면의 깊이 정보를 이산여현변환(discrete cosine transform)하고 이 DCT 공간상에서 유전자 알고리즘을 적용함으로써 큰 형상을 먼저 결정한 후 미세한 형상을 찾아내는 계층적인 표면 형상의 재구성이 가능하도록 하였으며 간단한 실험으로 그 타당성을 보인다.

  • PDF

3-D Data Modeling from Shading (영상로부터의 효과적인 3차원 데이터 모델링 방안)

  • 안은영
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2002.05c
    • /
    • pp.186-190
    • /
    • 2002
  • 영상의 밝기로부터 표면의 높이를 효과적으로 재구성하기 위한 방안으로 먼저 DCT공간상에서 표면의 형태를 구성한다. 이렇게 구성된 표면형태에 대한 정보를 기초로 축소된 영상과 입력영상에 대해 단계별로 표면을 구성한다. 표면 재구성 과정에서 생성되는 물체의 대략적인 표면정보는 버려지지 않고 게임 등 실시간으로 빠르게 처리해야하는 그래픽을 제공하기 위한 LOD(Level of Detail) 정보를 구성한다. 멀리 있는 물체에 대한 빠른 렌더링을 위해 표면 재구성 초기에 구성된 LOD 메쉬정보를 이용하고 가까운 물체의 경우에는 세밀한 표면의 형태를 표현하는 LOD 메쉬를 사용함으로써 그래픽 처리의 효율을 높일 수 있게 된다.

  • PDF

Production of Antimicrobial Compounds and Cloning of a dctA Gene Related Uptake of Organic Acids from a Biocontrol Bacterium Pseudomonas Chlororaphis O6 (생물적 방제균 Pseudomonas chlororaphis O6의 길항 물질 생산 및 유기산 흡수에 관련된 dctA 유전자의 클로닝)

  • Han, Song-Hee;Nam, Hyo-Song;Kang, Beom-Ryong;Kim, Kil-Yong;Koo, Bon-Sung;Cho, Baik-Ho;Kim, Young-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.3
    • /
    • pp.134-144
    • /
    • 2003
  • A rhizobacterium Pseudomonas cholororaphis O6 produced several secondary metabolites, such as phenazines, protease, and HCN that may be involved in inhibition of the growth of phytopathogenic fungi. In field study, P. chlororaphis O6 treatment on wheat seed suppressed root rot disease caused by Fusarium culmorum. The major organic acids of cucumber root exudates were fumaric acid, malic acid, benzoic acid, and succinic acid. Glucose and fructose were major monosaccharides in cucumber root exudates. The total amount of organic acids was ten times higher than that of the sugars. P. chlororaphis O6 grew well on cucumber root exudates. The dctA gene of P. chlororaphis O6 consisted of a 1,335 bp open reading frame with a deduced amino acid sequence of 444 residues, corresponding to a molecular size of about 47 kD and pI 8.2. The deduced dctA sequence has ten putative transmembrane domains, as expected of a membrane-embedded protein. Our results indicated that organic acids in cucumber root exudates may play an important role in providing nutrient source for root colonization of biological control bacteria, and the dctA gene of P. chlororaphis O6 may be an important bacterial trait that is involved in utilization of root exudates.

Evaluating Correlation between Geometrical Relationship and Dose Difference Caused by Respiratory Motion Using Statistical Analysis

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Cho, Min-Seok;Noh, Yu-Yoon;Yoon, Do-Kun;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.203-212
    • /
    • 2016
  • Dose differences between three-dimensional (3D) and four-dimensional (4D) doses could be varied according to the geometrical relationship between a planning target volume (PTV) and an organ at risk (OAR). The purpose of this study is to evaluate the correlation between the overlap volume histogram (OVH), which quantitatively shows the geometrical relationship between the PTV and OAR, and the dose differences. 4D computed tomography (4DCT) images were acquired for 10 liver cancer patients. Internal target volume-based treatment planning was performed. A 3D dose was calculated on a reference phase (end-exhalation). A 4D dose was accumulated using deformation vector fields between the reference and other phase images of 4DCT from deformable image registration, and dose differences between the 3D and 4D doses were calculated. An OVH between the PTV and selected OAR (duodenum) was calculated and quantified on the basis of specific overlap volumes that corresponded to 10%, 20%, 30%, 40%, and 50% of the OAR volume overlapped with the expanded PTV. Statistical analysis was performed to verify the correlation with the OVH and dose difference for the OAR. The minimum mean dose difference was 0.50 Gy from case 3, and the maximum mean dose difference was 4.96 Gy from case 2. The calculated range of the correlation coefficients between the OVH and dose difference was from -0.720 to -0.712, and the R-square range for regression analysis was from 0.506 to 0.518 (p-value <0.05). However, when the 10% overlap volume was applied in the six cases that had OVH value ${\leq}2$, the average percent mean dose differences were $34.80{\pm}12.42%$. Cases with quantified OVH values of 2 or more had mean dose differences of $29.16{\pm}11.36%$. In conclusion, no significant statistical correlation was found between the OVH and dose differences. However, it was confirmed that a higher difference between the 3D and 4D doses could occur in cases that have smaller OVH value.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Digital Hologram Coding Technique using Block Matching of Localized Region and MCTF (로컬영역의 정합기법 및 MCTF를 이용한 디지털 홀로그램 부호화 기술)

  • Seo, Young-Ho;Choi, Hyun-Jun;Kim, Dong-Wook
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.415-416
    • /
    • 2006
  • In this paper, we proposed a new coding technique of digital hologram video using 3D scanning method and video compression technique. The proposed coding consists of capturing a digital hologram to separate into RGB color space components, localization by segmenting the fringe pattern, frequency transform using $M{\tiems}N$ (segment size) 2D DCT (2 Dimensional Discrete Cosine Transform) for extracting redundancy, 3D scan of segment to form a video sequence, motion compensated temporal filtering (MCTF) and modified video coding which uses H.264/AVC.

  • PDF