• Title/Summary/Keyword: 3D Beam

Search Result 1,695, Processing Time 0.028 seconds

Realization of 1D-2DEG Composite Nanowire FET by Selective Area Molecular Beam Epitaxy (선택적 분자선 에픽택시 방법에 의한 1D-2DEG 혼성 나노선 FET의 구현)

  • Kim, Yun-Joo;Kim, Dong-Ho;Kim, Eun-Hong;Seo, Yoo-Jung;Roh, Cheong-Hyun;Hahn, Cheol-Koo;Ogura, Mutsuo;Kim, Tae-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1005-1009
    • /
    • 2006
  • High quality three-dimensional (3D) heterostructures were constructed by selective area (SA) molecular beam epitaxy (MBE) using a specially patterned GaAs (001) substrate to improve the efficiency of tarrier transport. MBE growth parameters such as substrate temperature, V/III ratio, growth ratio, group V sources (As2, As4) were varied to calibrate the selective area growth conditions and the 3D GaAs-AlGaAs heterostructures were fabricated into the ridge type and the V-groove type. Scanning micro-photoluminescence $({\mu}-PL)$ measurements and the following analysis revealed that the gradually (adiabatically) coupled 1D-2DEG (electron gas) field effect transistor (FET) system was successfully realized. These 3D-heterostructures are expected to be useful for the realization of high-performance mesoscopic electronic devices and circuits since it makes it possible to form direct ohmic contact onto the (quasi) 1D electron channel.

Vibration analysis of a Timoshenko beam carrying 3D tip mass by using differential transform method

  • Kati, Hilal Doganay;Gokdag, Hakan
    • Structural Engineering and Mechanics
    • /
    • v.65 no.4
    • /
    • pp.381-388
    • /
    • 2018
  • Dynamic behaviour of beam carrying masses has attracted attention of many researchers and engineers. Many studies on the analytical solution of beam with concentric tip mass have been published. However, there are limited works on vibration analysis of beam with an eccentric three dimensional object. In this case, bending and torsional deformations of beam are coupled due to the boundary conditions. Analytical solution of equations of motion of the system is complicated and lengthy. Therefore, in this study, Differential Transform Method (DTM) is applied to solve the relevant equations. First, the Timoshenko beam with 3D tip attachment whose centre of gravity is not coincident with beam end point is considered. The beam is assumed to undergo bending in two orthogonal planes and torsional deformation about beam axis. Using Hamilton's principle the equations of motion of the system along with the possible boundary conditions are derived. Later DTM is applied to obtain natural frequencies and mode shapes of the system. According to the relevant literature DTM has not been applied to such a system so far. Moreover, the problem is modelled by Ansys, the well-known finite element method, and impact test is applied to extract experimental modal data. Comparing DTM results with finite element and experimental results it is concluded that the proposed approach produces accurate results.

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

A 3D Face Modeling Method Using Region Segmentation and Multiple light beams (지역 분할과 다중 라이트 빔을 이용한 3차원 얼굴 형상 모델링 기법)

  • Lee, Yo-Han;Cho, Joo-Hyun;Song, Tai-Kyong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.6
    • /
    • pp.70-81
    • /
    • 2001
  • This paper presents a 3D face modeling method using a CCD camera and a projector (LCD projector or Slide projector). The camera faces the human face and the projector casts white stripe patterns on the human face. The 3D shape of the face is extracted from spatial and temporal locations of the white stripe patterns on a series of image frames. The proposed method employs region segmentation and multi-beam techniques for efficient 3D modeling of hair region and faster 3D scanning respectively. In the proposed method, each image is segmented into face, hair, and shadow regions, which are independently processed to obtain the optimum results for each region. The multi-beam method, which uses a number of equally spaced stripe patterns, reduces the total number of image frames and consequently the overall data acquisition time. Light beam calibration is adopted for efficient light plane measurement, which is not influenced by the direction (vertical or horizontal) of the stripe patterns. Experimental results show that the proposed method provides a favorable 3D face modeling results, including the hair region.

  • PDF

Seismic Performance Evaluation of Curved Bridges by Gyeong-Ju Earthquakes (경주지진에 의한 곡선교량의 내진 안전성 평가)

  • Jeon, Jun-Tai
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2018
  • This study presented 3D Finite Element (FE) analysis of curved beam structures subjected to static and dynamic loading conditions, which is particularly strong ground motions. It was shown that the results obtained from 3D FE analyses was similar to the theoretical solution within 1% convergency error, in order to validate the 3D solid FE models in this study. In particular, it was focusing on development of dynamic characteristics of curved beam structures subjected to three-different seismic ground motions: GyeongJu, Lomaprieta and Northridge earthquakes. Consequently, It was interesting to find that the results obtained from GyeongJu earthquake was detuned due to high frequency effect, but the Von-Mises of the curved beam structure under Lomaprieta earthquake was 647.824 MPa at 45 curvature degree.

Effect of Proton Beam Radiation on Bulbil Yield and Gibberellins of Chinese Yam (Dioscorea opposita Thunb.)

  • Kim, Sang-Kuk;Choi, Hong-Jib;Kim, Kye-Ryung;Lee, In-Jung;Kim, Hak-Yoon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.56 no.3
    • /
    • pp.250-254
    • /
    • 2011
  • The study was carried out to evaluate the affect of proton beam radiation on production of bulbil and tuber including change of endogenous gibberellins, of Dioscorea opposita Thunb. The yield of bulbils and tubers from non- and irradiated D. opposita Thunb at doses of 5, 10, 15 and 20 Gy were determined. Endogenous gibberellins were also quantified by GC/MS analysis. D. opposita tubers irradiated at 15 Gy produced higher bulbil production than non-irradiated plants. Enlarged bulbil (above size diameter 4 mm) was significantly increased at 15 Gy. Bioactive endogenous $GA_4$ was dominant in bulbils and tubers irradiated with proton beam rather than $GA_1$. Major gibberellins biosynthetic pathways in bulbils and tubers of D. opposita plants were non C-13 hydroxylation route. From the results of this study, 15 Gy proton beam radiation was suggested as an optimal dose that can produce high amounts of bulbil for mass production of D. opposita plant.

Active Focusing of Light in Plasmonic Lens via Kerr Effect

  • Nasari, Hadiseh;Abrishamian, Mohammad Sadegh
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.305-312
    • /
    • 2012
  • We numerically demonstrate the performance of a plasmonic lens composed of an array of nanoslits perforated on thin metallic film with slanted cuts on the output surface. Embedding Kerr nonlinear material in nanoslits is employed to modulate the output beam. A two dimensional nonlinear-dispersive finite-difference time-domain (2D N-D-FDTD) method is utilized. The performance parameters of the proposed lens such as focal length, full-width half-maximum, depth of focus and the efficiency of focusing are investigated. The structure is illuminated by a TM-polarized plane wave and a Gaussian beam. The effect of the beam waist of the Gaussian beam and the incident light intensity on the focusing effect is explored. An exact formula is proposed to derive electric field E from electric flux density D in a Kerr-Dispersive medium. Surface plasmon (SPs) modes and Fabry-Perot (F-P) resonances are used to explain the physical origin of the light focusing phenomenon. Focused ion beam milling can be implemented to fabricate the proposed lens. It can find valuable potential applications in integrated optics and for tuning purposes.

Nonlocal integral elasticity analysis of beam bending by using finite element method

  • Taghizadeh, M.;Ovesy, H.R.;Ghannadpour, S.A.M.
    • Structural Engineering and Mechanics
    • /
    • v.54 no.4
    • /
    • pp.755-769
    • /
    • 2015
  • In this study, a 2-D finite element formulation in the frame of nonlocal integral elasticity is presented. Subsequently, the bending problem of a nanobeam under different types of loadings and boundary conditions is solved based on classical beam theory and also 3-D elasticity theory using nonlocal finite elements (NL-FEM). The obtained results are compared with the analytical and numerical results of nonlocal differential elasticity. It is concluded that the classical beam theory and the nonlocal differential elasticity can separately lead to significant errors for the problem under consideration as distinct from 3-D elasticity and nonlocal integral elasticity respectively.

Preliminary Test of 3D Printed Plastic Scintillators for Proton Beam (3D 프린팅 플라스틱 섬광체의 양성자 빔에 대한 적용)

  • Sung-Hwan, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.681-686
    • /
    • 2022
  • In this study, a scintillation resin for 3D printing was fabricated with 1.0 wt% of PPO organic scintillator, 5.0 wt% of MMA, and commercial acrylic resin. Using the scintillation resin, 3D-shaped plastic scintillator radiation sensors were successfully fabricated quickly and inexpensively with a commercial 3D DLP printer. The 3D printed plastic scintillator has a good dose-output linearity of R-square 0.998 was obtained in the range of 1 to 10 nA of beam current of the 45 MeV proton beam. The developed 3D plastic scintillator has low light output, so there is a limit to its use in low-dose-rate gamma-ray or X-ray dosimetry. However, it was confirmed that the tissue equivalent material could be usefully used for measuring high energy or high dose rates radiation, such as proton beams and ultra-high dose rate beams.

The Efficiency of 3D Design in the PSC Beam Bridge (PSC Beam 교에서의 3D 설계 효용성)

  • Shin, Wook-Beom;Ahn, Do-Hwan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.104-107
    • /
    • 2008
  • A case study is conducted by between using 3D integrated automatic design software(ABeamDeck, AAbutPier) and using autocad without program to validate the method. As a result, there are many profits introducing the 3D design in the construction, especially, to make up for defect of existing design method. 3D design will enhance the efficiency of construction tasks by supporting a system of sharing and exchanging information throughout all the stages of construction, from design, production and installation to maintenance.

  • PDF