• Title/Summary/Keyword: 3D 재구성

Search Result 482, Processing Time 0.025 seconds

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

Mobile Panorama System via 3D Model Reconstruction (3차원 모델 재구성을 통한 모바일 파노라마 시스템)

  • Kim, Jin-Hee;Choy, Yoon-Chul;Han, Tack-Don;Lim, Soon-Bum
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.8
    • /
    • pp.1094-1107
    • /
    • 2011
  • We can use panorama systems or image based modeling systems when we want to make 3D space model and look around result. Panorama systems make 3D model to stitch images and map cylinder or cube. The structure of 3D model, made by panorama system, is not same as structure of a real room, so user can't infer a real structure. Typically, Image based modeling systems work on a desktop computer. That makes it difficult to reconstruct 3D model in real time and take long time for processing. In this paper, we propose a 3D panorama modeling system that uses images on a mobile device. This system reconstructs a 3D space model, similar with a real room in real time, from multiple images captured part of rooms. Using this system, user can reconstruct various shape of space and look around a 3D space model.

Noise Smoothing using the 2D/3D Magnitude Ratio of Mesh Data (메쉬 데이터의 2D/3D 면적비를 이용한 잡음 평활화)

  • Hyeon, Dae-Hwan;WhangBo, Taeg-Keun
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.4
    • /
    • pp.473-482
    • /
    • 2009
  • Reconstructed 3D data from computer vision includes necessarily a noise or an error. When these data goes through a mesh process, the different 3D mesh data from original shape comes to make by a noise or an error. This paper proposed the method that smooths a noise effectively by noise analysis in reconstructed 3D data. Because the proposed method is smooths a noise using the area ratio of the mesh, the pre-processing of unusable mesh is necessary in 3D mesh data. This study detects a peak noise and Gaussian noise using the ratio of 3D volume and 2D area of mesh and smooths the noise with respect of its characteristics. The experimental results using synthetic and real data demonstrated the efficacy and performance of proposed algorithm.

  • PDF

The Study about Application of LEAP Collimator at Brain Diamox Perfusion Tomography Applied Flash 3D Reconstruction: One Day Subtraction Method (Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구: One Day Subtraction Method)

  • Choi, Jong-Sook;Jung, Woo-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.102-109
    • /
    • 2009
  • Purpose: Flash 3D (pixon(R) method; 3D OSEM) was developed as a software program to shorten exam time and improve image quality through reconstruction, it is an image processing method that usefully be applied to nuclear medicine tomography. If perfoming brain diamox perfusion scan by reconstructing subtracted images by Flash 3D with shortened image acquisition time, there was a problem that SNR of subtracted image is lower than basal image. To increase SNR of subtracted image, we use LEAP collimators, and we emphasized on sensitivity of vessel dilatation than resolution of brain vessel. In this study, our purpose is to confirm possibility of application of LEAP collimators at brain diamox perfusion tomography, identify proper reconstruction factors by using Flash 3D. Materials and methods: (1) The evaluation of phantom: We used Hoffman 3D Brain Phantom with $^{99m}Tc$. We obtained images by LEAP and LEHR collimators (diamox image) and after 6 hours (the half life of $^{99m}Tc$: 6 hours), we use obtained second image (basal image) by same method. Also, we acquired SNR and ratio of white matters/gray matters of each basal image and subtracted image. (2) The evaluation of patient's image: We quantitatively analyzed patients who were examined by LEAP collimators then was classified as a normal group and who were examined by LEHR collimators then was classified as a normal group from 2008. 05 to 2009. 01. We evaluate the results from phantom by substituting factors. We used one-day protocol and injected $^{99m}Tc$-ECD 925 MBq at both basal image acquisition and diamox image acquisition. Results: (1) The evaluation of phantom: After measuring counts from each detector, at basal image 41~46 kcount, stress image 79~90 kcount, subtraction image 40~47 kcount were detected. LEAP was about 102~113 kcount at basal image, 188~210 kcount at stress image and 94~103 at subtraction image kcount were detected. The SNR of LEHR subtraction image was decreased than LEHR basal image about 37%, the SNR of LEAP subtraction image was decreased than LEAP basal image about 17%. The ratio of gray matter versus white matter is 2.2:1 at LEHR basal image and 1.9:1 at subtraction, and at LEAP basal image was 2.4:1 and subtraction image was 2:1. (2) The evaluation of patient's image: the counts acquired by LEHR collimators are about 40~60 kcounts at basal image, and 80~100 kcount at stress image. It was proper to set FWHM as 7 mm at basal and stress image and 11mm at subtraction image. LEAP was about 80~100 kcount at basal image and 180~200 kcount at stress image. LEAP images could reduce blurring by setting FWHM as 5 mm at basal and stress images and 7 mm at subtraction image. At basal and stress image, LEHR image was superior than LEAP image. But in case of subtraction image like a phantom experiment, it showed rough image because SNR of LEHR image was decreased. On the other hand, in case of subtraction LEAP image was better than LEHR image in SNR and sensitivity. In all LEHR and LEAP collimator images, proper subset and iteration frequency was 8 times. Conclusions: We could archive more clear and high SNR subtraction image by using proper filter with LEAP collimator. In case of applying one day protocol and reconstructing by Flash 3D, we could consider application of LEAP collimator to acquire better subtraction image.

  • PDF

Design of Frequency Reconfigurable Antenna with the Vertically Stacked Dipole Structure (수직 적층형 다이폴 구조를 갖는 주파수 재구성 안테나 설계)

  • Jung, Young-Jin;Hong, Ic-Pyo;Eom, Soon-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.5
    • /
    • pp.552-559
    • /
    • 2011
  • In this paper, the frequency reconfigurable antenna is proposed and designed. The proposed antenna is designed using the vertically stacked dipole structures and have the operating band for Cellular, PCS/WCDMA/Wibro/WiFi and WiMAX. The operating frequency band is selected by three pair of PIN diodes using the voltage difference between each dipole antenna and feeding transmission lines. The proposed antenna meets the required operating bandwidth and the maximum gain for each frequency band are measured as 6.3 dBi, 5.4 dBi and 5.8 dBi, respectively. The proposed antenna in this paper can be applied for the future mobile small base station or repeater antenna because this antenna can provide the small size and high gain features.

A New Voxel Coloring Method for 3D Shape Reconstruction (3차원 형상 재구성을 위한 새로운 복셀 칼라링 기법)

  • Ye Sooyoung;Kim Hyosung;Joo Jaeheum;Nam Kigon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.42 no.6
    • /
    • pp.93-100
    • /
    • 2005
  • We propose an optimal thresholding method for the voxel coloring in the reconstruction of a 3D shape. Our purposed method is a new approach to resolve the trade-off error of the threshold value on determining the photo-consistency in the conventional method. Optimal thresholding value is decided to compare the photo-consistency of a surface with inside voxel on the optic ray of the center camera. As iterating the process of the vokels, the threshold is approached to the optimal value for the individual surface voxel. And also, graph cut method is reduced to the surface noise on eliminating neighboring voxel. To verify the proposed algorithm, we simulated in the virtual and real environment. It is advantaged to speed up and accuracy of a 3D face reconstruction by applying the methods of optimal threshold and graph as compare with conventional algorithms.

Surgical Simulation Environment for Replacement of Artificial Knee Joint (CT 영상을 이용한 무릎관절 모의 치환 시술 환경)

  • Kim, Dong-Min
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.119-126
    • /
    • 2003
  • This paper presents a methodology for constructing a surgical simulation environment for the replacement of artificial knee join using CT image data. We provide a user interface of preoperative planning system for performing complex 3-D spatial manipulation and reasoning tasks. Simple manipulation of joystick and mouse has been proved to be both intuitive and accurate for the fitness and the wear expect of joint. The proposed methodology are useful for future virtual medical system where all the components of visualization, automated model generation, and surgical simulation are integrated.

  • PDF

Real-time 3D Feature Extraction Combined with 3D Reconstruction (3차원 물체 재구성 과정이 통합된 실시간 3차원 특징값 추출 방법)

  • Hong, Kwang-Jin;Lee, Chul-Han;Jung, Kee-Chul;Oh, Kyoung-Su
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.12
    • /
    • pp.789-799
    • /
    • 2008
  • For the communication between human and computer in an interactive computing environment, the gesture recognition has been studied vigorously. The algorithms which use the 2D features for the feature extraction and the feature comparison are faster, but there are some environmental limitations for the accurate recognition. The algorithms which use the 2.5D features provide higher accuracy than 2D features, but these are influenced by rotation of objects. And the algorithms which use the 3D features are slow for the recognition, because these algorithms need the 3d object reconstruction as the preprocessing for the feature extraction. In this paper, we propose a method to extract the 3D features combined with the 3D object reconstruction in real-time. This method generates three kinds of 3D projection maps using the modified GPU-based visual hull generation algorithm. This process only executes data generation parts only for the gesture recognition and calculates the Hu-moment which is corresponding to each projection map. In the section of experimental results, we compare the computational time of the proposed method with the previous methods. And the result shows that the proposed method can apply to real time gesture recognition environment.

자기공명영상에서 신호의 dynamic range와 quantization noise 분석

  • 안창범;이정선;김휴정;이흥규
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.75-75
    • /
    • 2002
  • 목적: 고자장 자기공명영상 시스템 등으로 신호대잡음비가 향상됨에 따라 데이터 측정에서 analog-to-digital converter (ADC)의 quantization noise 가 중요한 시스템 사양으로 부각되고 있다. 특히 자기공명영상은 공간주파수 영역에서 데이터를 측정하기 때문에 dc와 ac간의 신호 차이가 매우 크며, 이러한 dynmic range는 3-D 영상에서 더욱 커진다. 본 연구에서는 다양한 자기총명 영상기법 및 실험 파라미터에 따른 신호의 dynamic range와 ADC의 bit 수에 따른 quantization noise를 살펴봄으로써, 주어진 시스템에 적합한 ADC의 bit 수를 분석하고자 한다. 대상 및 방법: 펄스 시퀀스의 종류, 파라미터, 2D/3D 등에 따른 각 신호의 크기를 수학적으로 모델링하여 신호의 크기를 예측하였다. 또한 whole body MRI 시스템에서 실험을 통하여 신호의 크기를 비교하였다. ADC의 quantization noise를 실험과 시뮬레이션을 통하여 살펴보았다. 시뮬레이션은 test 영상을 Inverse FFT 하여 spatial frequency domain data를 만든 후, 다양한 bit 수의 ADC로 quantization을 한 후 다시 영상을 재구성하였다. 재구성된 영상과 원영상 간의 error가 quantization noise가 된다. 또한 이러한 error가 주파수 영역에서의 error 값과 일치하는지를 확인하였다.

  • PDF

Virtual DressUp system by using image deformation method (이미지 변형 기법을 이용한 가상 드레스업 시스템)

  • Kim, Na-Ri;Yoon, Jong-Chul;Lee, In-Kwon
    • Journal of the Korea Computer Graphics Society
    • /
    • v.15 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • This paper introduces a virtual dress up system, according to user's input model and garment image. At first step, we deform the garment image by using skeleton structures and ARAP method. Next step, sampling the boundary points and find their matching vertices which are used for optimizing the boundary fitting. In 2D rendering of the dress up, they have some unrealistic results, so we reconstruct the garment mesh to the 3D mesh. Rendering from the reconstructed 3D mesh, we can get the final dress up result. We present that our system produce a visually plausible and well-fitted virtual dress up results.

  • PDF