• Title/Summary/Keyword: 3D 검사

Search Result 1,513, Processing Time 0.034 seconds

Comparative Evaluation of 25-OH-VitD and 25-OH-VitD3 by Radioimmunoassay (방사면역 측정법에 의한 25-OH-VitD와 25-OH-VitD3의 비교 평가)

  • Lee, Young-ji;Park, Ji-hye;Lim, Soo-yeon;Cheon, Jun-hong;Lee, Sun-ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.33-38
    • /
    • 2020
  • Purpose Vitamin D is essential for maintaining bone health, controling cell proliferation or differentiation, strengthening immune function by controlling calcium metabolism in the body. Vitamin D deficiency can lead to increase the risk of rickets, osteoporosis, cardiovascular disease, diabetes and cancer. Especially, South Korea is one of the highest population proportion of vitamin D deficiency. Accurate determination of levels of 25-OH-VitD or 25-OH-VitD3 in blood serum is required for the diagnosis and treatment of vitamin D deficiency. In this study, radioimmunoassay of 25-OH-VitD and 25-OH-VitD3 was performed and compared to evaluate the effectiveness of Vitamin D radioimmunoassay. Materials and Methods Serum 25-OH-VitD and 25-OH-VitD3 levels were measured using radioimmunoassay. The interrelationship, reproducibility and population distribution rate were evaluated. In addition, the internal quality control was performed at Asan Medical Center from April 2017 to June 2019 and the result of external quality control (Interagency proficiency evaluation) of first and second half of 2018 hosted by the Korean Society of Nuclear Medicine Technology (KSNMT). Both tests were measured by same manufacturer's reagent. Results 25-OH-VitD showed a strong positive correlation on 97 samples, as 25-OH-VitD3 x 0.9 + 0.3 (R>0.9). In repeated measurement, the average Diff(%) value of the reproducibility evaluation of 25-OH-VitD and 25-OH-VitD3 were 7.7% and 7.4%, respectively. Population distribution results showed no statistically significant differences(p>0.05). The resultant value of internal quality control, which measured from April, 2017 to June 2019 in Blood test room of Nuclear Medicine at Asan Medical Center, showed average (CV%) 6.2% and 6.8%, respectively. As a result of the external quality control (interagency proficiency evaluation) Z value obtained under 2.0, as shown below; Conclusion The interrelationship, reproducibility, population distribution rate, internal quality control and external quality control between 25-OH-VitD and 25-OH-VitD3 radioimmunoassay shows superior outcome. Radioimmunoassay, which can be alone measured in the blood as 25-OH-VitD or 25-OH-VitD3, is considered suitable screening tests for the diagnosis of vitamin D deficiency.

A Study of Comparison Between Refractive Errors by Fixation Distance Variation with N-vision(open-view type) Auto-refractor and Refractive Error with Canon(Internal Fixation Target Type) Auto-refractor (개방형 자동굴절검사기의 주시거리에 따른 굴절이상도와 가상주시형 자동굴절 검사기의 굴절이상도와의 비교 연구)

  • Kim, Jae-Do;Kim, Tae-Hyun;Jeon, In-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.433-438
    • /
    • 2011
  • Purpose: To investigate the proper distance from patient to target when measuring refractive error using open view target type auto-refractor(OVTAR), it was compared refractive errors between by OVTAR using N-vision-K5001 auto-refractor and internal fixation target type auto-refractor(IFTAR) using Canon auto-refractor. Methods: 21 subjects(42 eyes) aged 22.2(${\pm}$3.4) years old who had over 1.0 of corrected visual acuity and no ocular disease were participated for this study. Noncycloplegic measurements of refractive error were performed using a IFTAR(RK-F1, Canon, Japan) and an OVTAR(N-vision-K5001, Shin-nippon, Japan). The distances from subjects to targets in using the open the view target type auto-refractor were 1 m, 3 m, 4 m and 6 m. The refractive errors were compared between by IFTAR and by 1 m, 3 m, 4 m and 6 m target distances respectively using OVTAR. Results: At 1 m fixation distance the mean of refractive errors for total subjects was not significantly different between by OVTAR(-2.75${\pm}$1.84 D) and by IFTAR(-2.95${\pm}$2.04 D)(p=0.06). However at 3, 4 and 6 m fixation distance refractive errors by OVTAR were significantly lower myopic refractive errors than by IFTAR(p<0.05). Conclusions: The distance from subject to fixation target is needed over 3 m for the measurement of refractive error using OVTAR even not to 5~6 m distance.

Inspection of Composite Working Implement of Tractor using 3D Scanning and Reverse Design (3차원스캐닝과 역설계를 이용한 트랙터 복합작업기 치수 검사)

  • Lee, Choong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.45-53
    • /
    • 2017
  • Disc harrow-type composite working implements of tractors are able to work almost 15km/hr. Soil reversing and plowing of agricultural fields are thereby faster than the existing rotavator speed of 2.5 km/h. In Korea, its supply process is being delayed because of the traditional tillage method of rotavator plowing operations. To develop products suitable for the domestic environment, an analysis and inspection was performed on the products of advanced specifications. 3D modeling was performed on main parts and frames using 3D scanner.

Assessment of Reproducibility and Repeatability for Color Vision Test (색각검사법의 재현성 및 반복성평가)

  • Joo, Seok-Hee;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.109-114
    • /
    • 2008
  • Purpose: To assess the reproducibility and repeatability for each color vision test method. Methods: The subjects for color vision test were 30 students without congenital color vision deficiency and they major in optometry in a university, Korea. The type of color vision test selected for this study were Hans color vision test, Hans 15 hue test and Lanthony D 15 hue test. The Ishihara test was added for assessment of reliability of inter-tester. Results: All of the subjects were classified into normal at pseudoisochromatic plates, but one subject's result showed mild blue-yellow color deficiency at Hue discrimination. Results of 3 repeated test for subjects and inter-tester examination showed no errors at pseudoisochromatic plates. There were differences in mild errors among repeated test at Hue discrimination, but no differences were found in the results of repeated test to classify color vision deficiency. Conclusion: Each tester had better be more skilled to test even simple color vision test for eliminating the possibility of mild errors. Each subject might just as well be careful in color vision test. It is required to test both method of pseudoisochromatic plates and Hue discrimination in screening test.

  • PDF

A 3D Measurement System for the Leads of Semiconductor Chips Using Phase Measuring Profilometry (Phase Measuring Profilometry를 이용한 반도체 칩의 Lead 높이 측정 방법)

  • Kim, Young-Doo;Cho, Tai-Hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.223-226
    • /
    • 2011
  • 반도체 공정에서 부품의 결함을 찾는 것은 완제품의 품질 개선을 위해 중요하다. 현재까지 많은 비전 알고리즘들이 부품의 결함을 찾기 위해 적용되고 있다. 그러나 이런 알고리즘 대부분은 2D 방식의 검사 방식에 머물고 있다. 그러나 이런 2D방식의 검사 방법은 반도체 칩의 Lead나 Pad 그리고 Solder Joint와 같이 3D 정보에 의해 불량 유무를 판결해야 하는 곳에 적용하기 어렵다. 이에 본 논문에서는 PMP(Phase Measuring Profilometry)방법에 의해 반도체 칩의 Lead부분을 검사하기 위한 시스템 구성과 방법을 제안한다.

Study for Field Inspection of Phase-Array Ultrasonic for Electro-fusion Joints of Polyethylene Gas Pipes (폴리에틸렌 가스배관 전기융착부 위상배열초음파검사 현장사례 연구)

  • Kil Seong-Hee;Kwon Jeong-Rock;Park Kyo-Shik
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.2 s.31
    • /
    • pp.61-67
    • /
    • 2006
  • We developed the ultrasonic phased array technique for obtaining ultrasonic images of electrofusion joints of polyethylene piping. And we inspected 4 cases at fields with this technique. First case is for the 300 mm diameter polyethylene electrofusion joint by using 3.5 MHz phased array sensor, second is for the 350 mm diameter saddle electrofusion joint, third is for the 400 mm diameter electrofusion joints and the last one is for the 400 mm diameter piping joints which will be used at 300 kPa suppling pressure.

  • PDF

Study on the 3D Assembly Inspection of Two-Step Variable Valve Lift Modules Using Laser-Vision Technology (레이저 비전을 이용한 2단 가변밸브 리프트 모듈의 3D 조립검사에 대한 연구)

  • Nguyen, Huu-Cuong;Kim, Do-Joong;Lee, Byung-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.10
    • /
    • pp.949-957
    • /
    • 2017
  • A laser-vision-based height measurement system is developed and implemented for the inspection of two-step variable valve lift module assemblies. The proposed laser-vision sensor module is designed based on the principle of laser triangulation. This paper summarizes the work on 3D point cloud data collection and height difference measurements. The configuration of the measurement system and the proposed height measurement algorithm are described and analyzed in detail. Additional measurement experiments on the height differences of valves and lash adjusters of a two-step variable valve lift module were implemented repeatedly to evaluate the accuracy and repeatability of the proposed measurement system. Experimental results show that the proposed laser-vision-based height measurement system achieves high accuracy, repeatability, and stabilization for the inspection of two-step variable valve lift module assemblies.

Evaluation for the Usefulness of Automated Blood Typing Analyzer (혈액은행 자동화 장비 도입의 유용성 평가)

  • Kim, Ha-na;Kim, Hee-Bum;Park, Hyun-Sang;Lee, Hyun-Im;Hong, Myung-Kook;Shin, Gyoung-Sook;Suh, In-Bum
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.6
    • /
    • pp.565-574
    • /
    • 2019
  • In this study, we evaluated the usefulness of an automatic blood typing analyzer using QWALYS-2 up (Diagast, Loos Cedex, France). During a month( 01OCT2013 - 31OCT2013) we performed 1,636 tests for ABO & RhD blood typing, 1,374 tests for antibody screen & identification tests and compared the results by automatic blood type analyzer with previous manual methods and column agglutination tests. And we analyzed the economic performance by comparison the test unit price between automatic blood type analyzer and manual methods. In ABO & RhD blood typing tests, there were complete concordances between manual and automated blood typing analyzer for 200 clinical samples. In Antibody screen tests, the concordance rate between manual and automated blood typing analyzer was 98.5% and more strong reaction in automated blood typing analyzer than manual methods. Therefore, the introduction of an automated blood typing analyzer, reagents costs were increased but labor costs were decreased. Considering the importance of transfusion safety and economic advantages, the introduction of an automated blood typing analyzer was very useful.