• Title/Summary/Keyword: 3D 검사

Search Result 1,513, Processing Time 0.031 seconds

High-Speed Penetration Detection and Correction of the 3-Dimensional(3D) Cloth Models Using a Virtual Cylinder in Geometrical Cloth Simulation (기하학적인 의복시뮬레이션에서 가상원통을 이용한 의복 3차원모델의 고속 관통검사와 수정)

  • Choi, Chang-Seok
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.10
    • /
    • pp.521-528
    • /
    • 2007
  • This paper proposes a new method for the high- speed penetration detection between the 3D human body model and the 3D cloth model using a virtual cylinder, and for the correction of the 3D cloth model. Penetration sometimes occurs locally, when the cloth model is adopted geometrically to the body. This method establishes the virtual cylinder surrounding the body model and the cloth model, and selects at a time the candidates of the penetrated points using the virtual cylinder. Finally, the penetrated points are detected among the candidates. Shift of the vertices or division of the edges in the penetrated points can correct the cloth model geometrically. This method works faster than the physical-based method. The latter requires the repeated detection of the penetrated points using bounding volume and the repeated corrections of the cloth model using dynamics.

Platelet Serotonin Level and Psychological Features of the Suicidal Attempters (자살시도 환자의 혈소판내 세로토닌 농도와 심리학적 특성에 관한 연구)

  • Jeong, Hee Yeon;Kwon, Young Joon;Park, In Joon;Hong, Se Yong;Choi, Eui Jung;Jin, Hyuk-Hee
    • Korean Journal of Biological Psychiatry
    • /
    • v.6 no.1
    • /
    • pp.81-88
    • /
    • 1999
  • Objectives : Significant progress has been made in understanding psychosocial, psychological, and environmental factors associated with suicide. However it is only recently that attention has been paid to the understanding of the neurobiology of suicide. The aim of this study was to examine the relationship between platelet serotonin level and suicidal behavior and psychological features of the suicidal attempters. Methods : After a suicidal attempt platelet serotonin level was measured from 21 patients and compared it with those from depression patients and normal controls. Also MMPI, HAM-D, Barratt impulsiveness scale(BIS) were done to evaluate their psychological features. Results : 1) There was no significant difference in sex ratio of the suicidal attempters. 2) There was no significant difference in platelet serotonin levels among three groups. 3) The analysis of MMPI revealed that the scores of D, Hs, Pt in clinical scales were significantly higher in suicide patients and scores of D, Pa, Si were in depression patients. 4) The HAM-D score was significantly higher in depression and suicide patients, especially in depression patients. 5) The analysis of Barratt impulsiveness scale revealed that the scores of nonplanning, motor and cognitive impulsiveness scale were significantly higher in suicide patients. Conclusions : There was no significant difference in platelet serotonin levels among three groups. However the analysis of psychological features revealed significant differences. Therefore we concluded that psychological examinations are benefit to evaluate the suicidal tendency.

  • PDF

Study on the Development of an Outdoor Radiographic Test Shield Using 3D Printer Filament Materials (3D 프린터 필라멘트 재료를 이용한 야외 방사선투과검사용 차폐체 개발을 위한 연구)

  • Mun, Ik-Gi;Shin, Sang-Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.565-572
    • /
    • 2019
  • In this study, shielding analysis of material and thickness of 3D printer filaments was performed for the manufacture of custom shielding by radiation workers during outdoor radiographic test. The shielding was attached to the ICRU Slab Phantom after selecting the voxel source $^{192}Ir$ and $^{75}Se$ through simulation using MCNPX, and the distance between the source and the slab Phantom was set at 100 cm. The 12 shielding materials were divided into 5 mm units up to 200 mm from the absence of shielding materials to evaluate the energy absorbed per unit mass of each shielding material. The results showed that the shielding effect was high in the order of ABS + Tungsten, ABS + Bismuth, PLA + Copper, PLA + Iron from all sources of radiographic test. However, compared to lead, the shielding effect was somewhat lower. Based on this study in the future, further study of the atomic number and the high density filament material is necessary.

An Efficient k-D tree Traversal Algorithm for Ray Tracing on a GPU (GPU상에서 동작하는 Ray Tracing을 위한 효과적인 k-D tree 탐색 알고리즘)

  • Kang, Yoon-Sig;Park, Woo-Chan;Seo, Choong-Won;Yang, Sung-Bong
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.3
    • /
    • pp.133-140
    • /
    • 2008
  • This paper proposes an effective k-D tree traversal algorithm for ray tracing on a GPU. The previous k-D tree traverse algorithm based on GPU uses bottom-up searching from a leaf to the root after failing to find the ray intersected primitive in the leaf node. During the bottom-up search the algorithm decides the current node is visited or not from the parent node. In such a way, we need to visit the parent node which was already visited and the duplicated bounding box intersection tests. The new k-D tree traverse algorithm reduces the brother and parent duplicated visit by using an efficient method which decides whether the brother node is already visited or not during the bottom-up search. Also the algorithm take place bounding box intersection tests only for the nodes which is not yet done. As a result our experiment shows the new algorithm is about 30% faster than the previous.

Audiological Findings of Congenital Ichthyosiform Dermatosis with Sensorineural Hearing Loss (난청을 동반한 선천성 어린선상 피부병의 청각학적 소견)

  • 한태희;최진택;김광현;박찬일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.40.3-41
    • /
    • 1981
  • The ichthyosiform dermatosis is consisted of a heterogenous group of hereditary disorders. Authors report a case of 26 year old female patient who has congenital ichthyosiform dermatosis associated with sensorineural hearing loss, neovascularization of cornea, partial alopecia and abnormalities of nails and teeth. The audiological findings of this patient were as follows: 1. Bilateral severe sensorineural hearing loss. 2. SISI scores: 100% at 1, 000 Hz and 4, 000 Hz on both ear. 3. Tone decay test: 25 dB decay at 1, 000 Hz and 4, 000 Hz respectively on both ear. 4. SRTs : 85 dB on both ear. 5. Speech discrimination scores : 80% at 95 dB hearing level(MCL) on both ear. With above results, cochlear lesion is suspected in this syndrome.

  • PDF

A Study on Fabrication and Characteristics of PZT Probe for Nondestructive Test (비파괴 검사를 위한 PZT 탐촉자의 제작 및 특성에 관한 연구)

  • 김철수;정규원;송준태
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.8
    • /
    • pp.613-619
    • /
    • 1998
  • Ultrasonic probes of 400kHz, 1MHz were fabricated using PZT-5Z plates. Epoxy was used for backing layer materials onthe plates. Nondestructive Test was carried using these probes. Pulse lobe width of impulse response was reduced 15.4% compare 1MHz with 400kHz and 96.6% compare 3MHz with 400kHz. The attenuation in aluminum was 2.05[dB/m] at 400kHz, 4/91[dB/m] at 1MHz, 7.35[dB/m] at 3HMz. Hole detection error of the first hole was 22.4% at 1HMz, 9.% at 3HMz, The second hole 11.6% at 1HMz, 4.7% at 3HMz. In the result of experiment of the hole detection error and resolution, 3HMz probe was the best among them.

  • PDF

Color Factor Analysis of in Farnsworth Test Panel D-15 (색각 검사용 Farnsworth Test Panel D-15의 칼라 인자 연구)

  • Kim, Yong-Geun;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.31-37
    • /
    • 2000
  • In order to color analyze of in Farnsworth Test Panel D-15 using a Protan, Deutan and Tritan test, we introduced the CIE system so that measured the reflectance light spectrum intensity in the 380~780 nm wavelength regions. The color difference of Panel D-15 was depended on the intensity of reflectance ratio in the 400~450 nm, 500~600 nm and more than 650 nm wavelength regions. From the reflectance spectra, we obtained the tristimulus X, Y, Z values, the $L^*a^*b^*$ and $L^*ab$ values of the 3-Dimension CIELAB system in a complement plane and light-darkness axis, the $U^*V^*$ values and the x, y values of chromaticity coordinates.

  • PDF

Structure and Fatigue Analyses of the Inspection Equipment Frame of a Semiconductor Test Handler Picker (반도체 테스트 핸들러 픽커 검사장비 프레임에 대한 구조 및 피로해석)

  • Kim, Young-Choon;Kim, Young-Jin;Kook, Jeong-Han;Cho, Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.5906-5911
    • /
    • 2014
  • Currently, there are many processes of package assembly and inspections of real fields that examine whether a manufactured semiconductor can be operated regularly and can endure low humidity or high temperatures. As the inspection equipment of a semiconductor test handler picker has been used at the inspection process, these inspection equipment frames were modelled in 3D and these models were analyzed using 3 kinds of fatigue loadings. As the analysis result, maximum deformation occurred at the midparts of the frames at cases 1 and 2. Among the cases of nonuniform fatigue loads, the 'SAE bracket history' with the severest change in load became the most unstable but the 'Sample history' became the most stable. Fatigue analysis result can be used effectively with the design of an inspecting equipment frame of a semiconductor test handler picker to examine the prevention and durability against damage.

Diurnal fluctuations of vision in myopes (근시안의 일일 시럭변동에 관한 연구)

  • Park, Sang-Chul;Sung, A-Young;Kim, Tae-Hyun;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.35-40
    • /
    • 2005
  • Subjective and objective visions were measured on young adults(mean 21 yrs, 126 eyes) who were free of any ocular diseases and laser surgery and none wore contact lenses. The aim of this study was to investigate the diurnal variation of vision through subjective and objective measurements. Subjective visual acuity were measured at 5 m three times a day, morning(8:00 AM-10:00 AM), noon(12:00 PM-2:00 PM) and afternoon(4:00 PM-6:00 PM). The instrument used for objective refraction right after visual acuity measurement was Nvision-K 5001(shin-nippon) which unique in being able to disregard subject's accommodation because of its unrestricted viewing conditions. Also, we measured that three times and then calculated the average values. The result showed that an average subjective visual acuity in the morning, noon, afternoon were 0.256(${\pm}0.263$), 0.266(${\pm}0.276$), 0.242(${\pm}0.249$) respectively. Average spherical equivalent power in objective refraction of right eyes showed -3.416 D(${\pm}2.907$), -3.359 D(${\pm}2.735$), -3.297 D(${\pm}2.709$) respectively and dioptric power was decreased from morning to afternoon. Vision changed throughout the day in both subjective and objective measurements nevertheless its variations were statistically insignificant(p<0.05). Therefore it does not seem to matter of time for either visual acuity test or refraction.

  • PDF