• Title/Summary/Keyword: 3D(three-dimensional)

Search Result 4,304, Processing Time 0.03 seconds

A Study on Development of Three-Dimensional Chocolate Printer (초콜릿 소재의 3차원 프린터 개발에 관한 연구)

  • Kim, Kyu Eon;Park, Keun;Lee, Chibum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.4
    • /
    • pp.293-298
    • /
    • 2017
  • In this study, we developed a 3D chocolate printer and studied the conditions needed for chocolate printing. Because chocolate is a mixture of cocoa mass, cocoa butter and sugar particles, its properties vary with temperature, and care is required in melting and extrusion. A chocolate supply unit is composed of a heating block and a syringe pump. It is integrated with a 3-axis linear robot. In order to be more accurate than the existing 3D chocolate printer is, the system was configured so that the printing line width became $430{\mu}m$. Printing performance was studied according to various parameters. The condition needed for printing lines with a stable width was discovered by the experimental design method and has been confirmed by a 2D line test. These 3D printing experiments showed that it was possible to build a 3D shape with an inclination angle of up to $45^{\circ}$ without support. Further, chocolate printing of a 3D shape has been successfully verified with the developed system.

A Study of Standard Head Model for Korean Adults by 3D Measurement (한국 성인의 3차원 표준 머리모형)

  • Kim Hye-Soo;Yi Kyong-Hwa;Park Se-Jin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.4 s.152
    • /
    • pp.542-553
    • /
    • 2006
  • The purpose of this study were to analyse of craniofacial shape by 3D and to develope of head models for Korean adults with gender and age groups. The 3D measurement technique adapted in this study was a novel approach compared that the same technique has been commonly used in measuring human bodies. The data and the model of head analysis can be used as a basic reference in developing various head related items such as hat, helmet, gas mask, ear phone, and etc. In this study, heads of 836 Korean adults were measured in 3D, analyzed by statistical methods, and modelized in 3D by gender and age groups. From the basic statistical data analysis, vertex-tragion and the length between the pupils were the longest in their twenties for both men and women, and grew shorter in elderly groups. In all categories, a significant difference appeared between men and women in their 20's, but the differences were less noticeable in elderly groups. Compared to the one size standard head model of the Korea Occupational Safety and Health Agency, the above three-dimensional standard head model would provide a more through fit because gender and age groups were sub-divided and analyzed in 3D.

Three Dimensional Building Construction Based on LIDAR Data (LIDAR 자료기반의 3차원 건물정보 구축)

  • Yoo, Hwan-Hee;Kim, Kyung-Whan;Kim, Seong-Sam
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.14 no.3 s.37
    • /
    • pp.13-22
    • /
    • 2006
  • Realistic 3D building construction in urban area has become an important issue because of increasing demand of 3D geo-spatial information in many application. Contrary to the conventional 3D building model construction approach using aerial images and high-resolution satellite imagery, it has been researched widely in building reconstruction using high-accuracy aerial LIDAR data in the latest. This paper presents a method for 3D building construction through building outlines extraction by LoG operator's Zero-crossing and line generation and refinement by Douglas-Peucker algorithm.

  • PDF

Generalized Kinematic Analysis for the Motion of 3-D Linkages using Symbolic Equation (기호방정식을 이용한 3차원 연쇄기구 운동해석의 일반화)

  • 김호룡
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.102-109
    • /
    • 1986
  • Based on the Hartenberg-Denavit symbolic equation, which is one of equations for the kinematic analysis of three dimensional (3-D) linkage, a generalized kinematic motion equation is derived utilizing Euler angles and employing the coordinates transformation. The derived equation can feasibly be used for the motion analysis of any type of 3-D linkages as well as 2-D ones. In order to simulate the general motion of 3-D linkgages on digital computer, the generalized equation is programmed through the process of numerical analysis after converting the equation to the type of Newton-Raphson formula and denoting it in matrix form. The feasibility of theoretically derived equation is experimentally proved by comparing the results from the computer with those from experimental setup of three differrent but generally empolyed 3-D linkages.

Dosimetric Comparison of Three-Dimensional Conformal, Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Dynamic Conformal Arc Therapy Techniques in Prophylactic Cranial Irradiation

  • Ismail Faruk Durmus;Dursun Esitmez;Guner Ipek Arslan;Ayse Okumus
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.41-47
    • /
    • 2023
  • Purpose: This study aimed to dosimetrically compare the technique of three-dimensional conformal radiotherapy (3D CRT), which is a traditional prophylactic cranial irradiation method, and the intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques used in the last few decades with the dynamic conformal arc therapy (DCAT) technique. Methods: The 3D CRT, VMAT, IMRT, and DCAT plans were prepared with 25 Gy in 10 fractions in a Monaco planning system. The target volume and the critical organ doses were compared. A comparison of the body V2, V5, and V10 doses, monitor unit (MU), and beam on-time values was also performed. Results: In planned target volume of the brain (PTVBrain), the highest D99 dose value (P<0.001) and the most homogeneous (P=0.049) dose distribution according to the heterogeneity index were obtained using the VMAT technique. In contrast, the lowest values were obtained using the 3D CRT technique in the body V2, V5, and V10 doses. The MU values were the lowest when DCAT (P=0.001) was used. These values were 0.34% (P=0.256) lower with the 3D CRT technique, 66% (P=0.001) lower with IMRT, and 72% (P=0.001) lower with VMAT. The beam on-time values were the lowest with the 3D CRT planning (P<0.001), 3.8% (P=0.008) lower than DCAT, 65% (P=0.001) lower than VMAT planning, and 76% (P=0.001) lower than IMRT planning. Conclusions: Without sacrificing the homogeneous dose distribution and the critical organ doses in IMRTs, three to four times less treatment time, less low-dose volume, less leakage radiation, and less radiation scattering could be achieved when the DCAT technique is used similar to conventional methods. In short, DCAT, which is applicable in small target volumes, can also be successfully planned in large target volumes, such as the whole-brain.

The Efficacy of Three-Dimensional Sweeping Mode Extracorporeal Shockwave Treatment for Plantar Fasciitis (3차원 동적집속모드 체외충격파 기기를 이용한 족저근막염 치료의 유용성)

  • Lim, Joo Ae;Lee, Chan Hee;Park, Jae Han
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.2
    • /
    • pp.84-87
    • /
    • 2022
  • Purpose: This was a pilot study to examine the clinical usefulness of the newly developed three-dimensional sweep mode extracorporeal shockwave treatment (ESWT) in patients with plantar fasciitis. Materials and Methods: Three-dimensional sweep mode ESWT was performed once a week for 5 weeks in patients with plantar fasciitis who showed no improvement with the conventional conservative treatment. A 100-mm visual analogue scale (VAS) reading for pain from walking and at rest after walking were collected before the treatment and 8 and 16 weeks after the initial treatment. In addition, the Foot and Ankle Outcome Score (FAOS) and EuroQol-5-dimension (EQ-5D) scores before and 16 weeks after the treatment were evaluated. Results: VAS for pain for walking improved from 50.60±8.38 to 19.80±15.61 at 8 weeks after the initial treatment (p=0.008) and 9.80±9.62 at 16 weeks after the treatment (p<0.001). VAS for pain at rest after walking improved from 36.60±19.55 to 11.80±12.95 at 8 weeks after the initial treatment (p=0.052) and 8.80±8.87 at 16 weeks after the treatment (p=0.024). Preoperative FAOS increased from an average of 74.80±9.73 before the treatment to an average of 81.00±8.86 at week 16 after the procedure (p=0.49) and compared to pre-treatment levels, there was a decrease of one level in the anxiety/depression domain of the EQ-5D, post-treatment. Conclusion: The results of this preliminary study confirmed that the newly developed EWST with the smart forging sweep mode was effective in improving pain and function in plantar fasciitis.

Intensity Modulation in Radiation Therapy (선량강도 조절법을 이용한 방사선치료)

  • 김성규;김명세
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.27-34
    • /
    • 1997
  • In radiation therapy, the goal of three dimensional conformal radiation therapy(3DCRT) is to conform the apatial distribution of the prescribed radiation dose to the precise 3D configuration of the tomor, and at the same time, to minimize the dose to the surrounding normal tissues. To optimize treatment volume of tomor, treatment volume will be same tomor volume. Biological considerations need to be incorporated in the intensity modulation optimization process. Planning of intensity modulated treatment can irradiate more 20% in tomor compare to conventional 3DCRT. In lung cancer and rectal cancer, planning of intensity modulated treatment showed optimizing dose distribution.

  • PDF

Quantitative Analysis of the Facial Nerve Using Contrast-Enhanced Three Dimensional FLAIR-VISTA Imaging in Pediatric Bell's Palsy

  • Seo, Jin Hee;You, Sun Kyoung;Lee, In Ho;Lee, Jeong Eun;Lee, So Mi;Cho, Hyun-Hae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.162-167
    • /
    • 2015
  • Purpose: To evaluate the usefulness of quantitative analysis of the facial nerve using contrast-enhanced three-dimensional (CE 3D) fluid-attenuated inversion recovery-volume isotopic turbo spin echo acquisition (FLAIR-VISTA) for the diagnosis of Bell's palsy in pediatric patients. Materials and Methods: Twelve patients (24 nerves) with unilateral acute facial nerve palsy underwent MRI from March 2014 through March 2015. The unaffected sides were included as a control group. First, for quantitative analysis, the signal intensity (SI) and relative SI (RSI) for canalicular, labyrinthine, geniculate ganglion, tympanic, and mastoid segments of the facial nerve on CE 3D FLAIR images were measured using regions of interest (ROI). Second, CE 3D FLAIR and CE T1-SE images were analyzed to compare their diagnostic performance by visual assessment (VA). The sensitivity, specificity, and accuracy of RSI measurement and VA were compared. Results: The absolute SI of canalicular and mastoid segments and the sum of the five mean SI (total SI) were higher in the palsy group than in the control group, but with no significant differences. The RSI of the canalicular segment and the total SI were significantly correlated with the symptomatic side (P = 0.028 and 0.015). In 11/12 (91.6%) patients, the RSI of total SI resulted in accurate detection of the affected side. The sensitivity, specificity, and accuracy for detecting Bell's palsy were higher with RSI measurement than with VA of CE 3D FLAIR images, while those with VA of CE T1-SE images were higher than those with VA of CE 3D FLAIR images. Conclusion: Quantitative analysis of the facial nerve using CE 3D FLAIR imaging can be useful for increasing the diagnostic performance in children with Bell's palsy when difficult to diagnose using VA alone. With regard to VA, the diagnostic performance of CE T1-SE imaging is superior to that of CE 3D FLAIR imaging in children. Further studies including larger populations are necessary.

Time-lapse 3-dimensional Seismic Study to Evaluate the Effect of Ground Reenforcement (지반보강 효과 평가를 위한 시차 3차원 탄성파 탐사)

  • Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.141-144
    • /
    • 2002
  • Three-dimensional seismic data, recorded with an interval of one year, indicate a velocity changes in the medium at the near surface. During that period of a year, the ground reinforcement work has been conducted at the railroad base in the study area. The time-thickness to the first reflector of the two data were picked and compared. The result showed that the velocity of the medium decreased at large part of the study area; however, no velocity decrease at the railroad base.

Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors (삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가)

  • Park, Myung-Hwan;Lee, Jin-Wan;Lee, Kang-Won;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.161-170
    • /
    • 2009
  • Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Methods : With a 3 Tesla MRI system and an 8-channel phase-array sensitivity-encoding (SENSE) coil, three 3D MRI techniques of 3D T1-weighted imaging (3D T1WI), 3D T2-weighted imaging (3D T2WI) and 3D fluid attenuated inversion recovery (3D FLAIR) imaging were optimized with adjusting SESNE factors in a water phantom and three human brains. The 2D SENSE factor was applied on the phase-encoding and the slice-encoding directions. Signal-to-noise ratio(SNR), percent signal reduction rate(%R), and contrast-to-noise ratio(CNR) were calculated by using signal intensities obtained in specific regions-of-interest (ROI). Results : In the phantom study, SENSE factor = 3 was provided in 0.2% reduction of signals against without using SENSE with imaging within 5 minutes for 3D T1WI. SENSE factor = 2 was provided in 0.98% signal reduction against without using SENSE with imaging within 5 minutes for 3D T2WI. SENSE factor = 4 was provided in 0.2% signal reduction against without using SENSE with imaging around 6 minutes for 3D FLAIR. In the human brain study, SNR and CNR were higher with SENSE factors = 3 than 4 for all three imaging techniques. Conclusion : This study was performed to optimize 2D SENSE factors in the three 3D MRI techniques that can be scanned in clinical time limitations with minimizing SNR reductions. Without compromising SNR and CNR, the optimum 2D SENSE factors were 3 and 4, yielding the scan time of about 5 to 6 minutes. Further studies are necessary to optimize 3D MRI techniques in other areas in human body.

  • PDF