Chung Soon Cheol;Sohn Jin Hun;Tack Gye Rae;Yi Jeong Han
Journal of the Korean Society for Precision Engineering
/
v.22
no.4
/
pp.173-180
/
2005
In this study, changes in verbal cognitive performance, blood oxygen saturation and heart rate due to 30% concentration oxygen supply were observed. Five male (24.6±0.9) and five female (22.2±1.9) college students were asked to perform 28 verbal cognitive tasks of the same difficulty during two types of oxygen (concentration 21%, 30%) administration. The experimental sequence consisted of Rest1 (1 min.), Control (1 min.), Task (4 min.), and Rest2 (4 min.) and the physiological signals such as blood oxygen saturation and heart rate were measured throughout the stages. The experimental result showed that the performance increased significantly at 30%'s concentration of oxygen rather than 21%'s, which shows oxygen supply has positive influence on verbal cognitive performance. When 30% concentration oxygen is supplied, the oxygen saturation in the blood significantly increased comparing to 21%. The heart rate showed no significant difference. Significant correlations were found between changes in oxygen saturation and cognitive performance. It is suggested that 30% oxygen can stimulate brain activation by increasing actual blood oxygen concentration in the process of cognitive performance.
In this study, changes in memory performance, blood oxygen saturation and heart rate according to 30% concentration oxygen supply were observed. Ten healthy male and female college students (male:$25.8{\pm}0.8$ years, female: $24.2{\pm}1.9$ years) participated in the study. The experiment was performed as Rest (1min.), Control task (1min.), Word presentation (1min.), Reaction time task (1min.), Distractor (2min.), and Word recall (1min.) and the physiological signals such as blood oxygen saturation and heart rate were measured throughout the stages. Subjects who received 30% oxygen recalled more words than those who received 21% oxygen, which shows 30% oxygen supply has influenced positively on memory cognitive performance. When 30% concentration oxygen is supplied, the blood oxygen saturation in the task phases was increased and the heart rate decreased when comparing to 21%. It means that 30% oxygen can stimulate brain activation by increasing actual blood oxygen concentration in the process of cognitive performance, and the heart rate decreases because enough oxygen is supplied to process the cognitive performance.
You Ji-Hye;Yi Jeong-Han;Sohn Jin-Hun;Chung Soon-Cheol
Science of Emotion and Sensibility
/
v.9
no.1
/
pp.1-7
/
2006
The purpose of this study is to analyze the effects of the inhalation of 30% oxygen on heart rate and oxygen saturation ($SPO_2$) during cycle isokinetic exercise, in comparison with the inhalation of 21% oxygen. This study used oxygen supply equipment that can supply each of 21% and 30% oxygen constantly at a rate of 8 liter/min. Ten healthy male college students ($25.2{\pm}2.2$ years) participated in the experiment twice, one for 21% oxygen and the other for 30% oxygen. Each experiment was composed of three sections (a total of 18 minutes), which were composure (2 minutes), cycle isokinetic exercise at a speed of $20{\pm}1km/h$ (10 minutes) and recovery (6 minutes). 21% or 30% oxygen was supplied only during the sections of isokinetic exercise and restoration. Heart rate during isokinetic exercise and recovery was lower with the inhalation of 30% oxygen than with that of 20% oxygen but no difference was observed in $SPO_2$. $SPO_2$ was not different possibly because the same work load was applied to the group of 21% oxygen and that of 30% oxygen. Heart rate was reduced with the inhalation of 30% oxygen possibly because a larger quantity of oxygen was supplied at the same work load.
In this study, the waste of landfill was treated using advanced enriched oxygen combustion system. The oxygen concentration of this study was 21%, 25%, 30% and 40% and the operating capacity was 200 g/min and the residence time was 10 minutes. As increased the oxygen concentration of combustion air. temperature of the incinerator was increased and the temperature was increased rapidly when the oxygen concentration was 30%. As increased the oxygen concentration, the NOx (ppm) of flue gas increase d for thermal NOx, however the CO (ppm) of flue gas decreased according to the increase of combustion efficiency . The optimum operation condition of incineration was obtained when the oxygen concentration is 30%${\sim}$40%. The unburned carbon of ash decreased from 10% to 4% when the oxygen concentration was increased from 21% to 30%, therefore the high combustion efficiency can be obtained if used the oxygen enriched combustion system.
Proceedings of the Korean Society for Emotion and Sensibility Conference
/
2003.11a
/
pp.81-83
/
2003
The present study attempted to observe what changes the supply of highly concentrated(30%) oxygen cause to people's ability and cerebrum lateralization of verbal cognition, compared to air of normal oxygen concentration(21%). The experiment consisted of two runs, one for verbal cognition test with normal air(21% of oxygen) and for verbal cognition test with more oxygen in the air(30% of oxygen). Functional brain images were taken form 3T MRI using the single-shot EPI method. There were more activations observed at the occipital, parietal, temporal, and frontal lobes, but there were no changes in cerebrum lateralization with 30% oxygen administration. The result of task performance showed the accuracy increased at 30%'s concentration of oxygen rather than 21%'s. It is concluded that the positive effect on the verbal cognitive performance level by the highly concentrated oxygen administration was due to changeless increase of left and right cerebrum activation.
Chung Soon Cheol;Shon Jin Hun;Lee Bongsoo;Lee Soo Yeol
Journal of the Korean Society for Precision Engineering
/
v.22
no.1
/
pp.193-198
/
2005
Changes in visuospatial cognitive performance, blood oxygen saturation and heart rate due to the highly concentrated oxygen administration were observed in this study. Six male ($25.8 \pm$1.0) and six female (($23.8 \pm$ 1.9) adults were asked to perform 20 visuospatial tasks with the same level of difficulties by supplying two different oxygen levels (21%, 30%). Experiment consisted of Rest1 (1 min.), Control (1 min.), Task (4 min.), and Rest2 (4 min.) and physiological signals such as blood oxygen saturation and heart rate were measured through each stage. The result showed the accuracy of task performance increased significantly at 30% oxygen concentration compared with 21%, which means oxygen supply has positive effects on visuospatial cognitive performance. When 30% oxygen was supplied, blood oxygen saturation during control and task phases was increased and heart rate was decreased compared with 21%. It means that 30% oxygen can stimulate brain activities by directly increasing the actual level of blood oxygen concentration during cognitive performance, and enough oxygen supply during cognitive performance make heart rate decrease.
Journal of the Korean Society for Precision Engineering
/
v.21
no.8
/
pp.180-187
/
2004
The present study attempted to investigate the effects of supply of highly concentrated (30%) oxygen on human ability of visuospatial cognition and cerebrum lateralization. compared to air of normal oxygen concentration (21%). The experiment consisted of two runs, one fur visuospatial cognition test with normal air (21% of oxygen) and for visuospatial cognition test with more oxygen in the air (30% of oxygen). Each run was composed of four blocks and each block included eight control tasks and five visuospatial tasks. Functional brain images were taken from 3T MRI using the single-shot EPI method. The result of task performance showed the accuracy increased at 30%'s concentration of oxygen rather than 21%'s. There were more activations observed at the left and right hemisphere, but there was decrease cerebrum lateralization with 30% oxygen administration. Thus, it is concluded that the positive effect on the visuospatial cognitive performance level by the highly concentrated oxygen administration was due to increase of cerebrum activation and decrease of cerebrum lateralization
Journal of Korean Institute of Industrial Engineers
/
v.30
no.1
/
pp.11-16
/
2004
Oxygen is an essential element for human beings' physical and mental activities, and in particular, plays an important role in brain functions. The present study attempted to investigate the effects of supply of highly concentrated (30%) oxygen on human ability of visuospatial cognition, compared to air of normal oxygen concentration (21%). This study sampled eight male university students (the average age: 23.5) as subjects. An equipment that supplies 21% and 30% oxygen at a constant rate of 8L/min was developed. Two types of questionnaire containing 20 questions were developed to measure the ability of visuospatial cognition, and accuracy and reaction time were calculated from the result of task performance. The average accuracy was $50.63{\pm}8.63$ [%] and $62.50{\pm}9.64$[%] for 21%and 30% oxygen respectively, and a statistically significant difference was found in the accuracy between the two types of oxygen. The average reaction time was $6.60{\pm}O.77$ [sec] and $7.23{\pm}0.69$ [sec] for 21%and 30% oxygen respectively, and a statistically significant difference was not found in the reaction time. The results showed that there is no difference in the average reaction time but the average accuracy rises with the supply of highly concentrated (30%) oxygen, indicating that the supply of highly concentrated oxygen has a partially positive effect on the ability of visuospatial cognition.
The present study attempted to observe what changes the supply of highly concentrated (30%) oxygen cause to people's ability of visuospatial cognition, compared to air of normal oxygen concentration (21%). This study sampled eight male university students (the average age : 23.5) as subjects for functional Magnetic Resonance Imaging (MRI) study It also developed equipment that supplies 21% and 30% oxygen) at a constant rate of 8L/min. Two questionnaires containing 20 questions were developed to measure the ability of visuospatial cognition, and accuracy was calculated from the result of task performance. The experiment paradigm consisted of the run conducting tasks at 30%'s concentration of oxygen and another run at 21%'s concentration of oxygen. Each run was composed of four blocks and each block included eight control tasks and five visuospatial taks. 3T MRI was used and fMRI was obtained through the single-shot EPI method. The activation in the occipital-associated area, bilateral superior parietal lobes, bilateral inferior parietal lobes. bilateral precuneus, bilateral postcentral gyri, bilateral middle frontal gyri, bilateral inferior frontal gyri, bilateral medial frontal gyri, bilateral superior frontal gyri, bilateral cingulate gyri was significantly increased at the 30%'s concentration of oxygen rather than 21%'s. Furthermore, the result of task performance showed the accuracy increased at 30%'s concentration of oxygen rather than 21%'s. From the result of this study, it is concluded that the supply of highly concentrated oxygen has a positive effect on the ability of visuospatial cognition.
Chung Soon-Cheol;Kim Ik-Hyeon;Tack Gye-Rae;Lee Soo Yeol;Sohn Jin-Hun
Journal of Biomedical Engineering Research
/
v.26
no.1
/
pp.1-7
/
2005
This study aimed to investigate the hypothesis that administration of the air with 30% oxygen compared with normal air (21% oxygen) enhances cognitive functioning through increased activation in the brain. Seventeen college students (righthanded, average age of 24.3) were selected as subjects for this study. An oxygen supply equipment that provides 21% and 30% oxygen at a constant rate of 8L/min was developed. In order to measure the performance level of visuospatial and verbal cognition, two psychological tests were developed. The experiment consisted of two runs, one for cognition task with normal air (21% oxygen) and the other for cognition task with hyperoxic air (30% oxygen). Visuospatial and verbal tasks were presented while brain images were scanned by a 3T fMRI system using the single-shot EPI method. The results showed that there was an improvement in performance and also increased activation in several brain areas in the higher oxygen condition. These results suggest that while performing cognitive tasks, high concentrations of oxygen administration make oxygen administration sufficient, thus making neural network activate more, and the ability to perform cognitive tasks increase.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.