• 제목/요약/키워드: 3-way valve

검색결과 104건 처리시간 0.022초

고속 온-오프 전자 밸브를 사용한 유압 실린더의 압력 제어 (Pressure Control of Hydraulic Cylinder using high Speed On-Off Solenoid Valve)

  • 김상수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권1호
    • /
    • pp.69-78
    • /
    • 1999
  • In this study a new pattern of pressure control of hydraulic cylinder using high speed On-Off solenoid valve in the electro-hydraulic system has been suggested. The control valve is 3-way high speed On-Off solenoid valve which is operated by PWM(Pulse Width Modulation)control signal. The high speed On-Off solenoid valve has a tendency to induce severe pressure fluctuation in the hydraulic actuator so it has not been used for the purpose of closed loop control with direct pres-sure feedback. In this study closed loop control with direct pressure feedback is enabled by using a digital filter which has linear minimum mean square filter algorithm. Through some experiments it is confirmed that stable pressure control can be realized by the proposed control technique.

  • PDF

개비온 끝단 소둔선 결합용 이송 가이드 장치 개발 연구 (Development of Transportational Guide System for Joining Small Wire with Gabion)

  • 이종길;김종태
    • 대한공업교육학회지
    • /
    • 제31권1호
    • /
    • pp.211-225
    • /
    • 2006
  • 개비온은 일반적으로 도로 유실 방지나 사방공사용으로 사용된다. 그러나 개비온의 끝단과 소둔선의 결합은 수동 작업으로 이루어지고 있다. 본 논문에서는 개비온 끝단을 소둔선과 자동으로 결합하기 위한 자동 이송 가이드 장치를 개발하고 이를 시험하였다. 자동 이송 가이드 장치는 공압 회로를 이용하여 설계하고 실린더의 이송 변위를 시뮬레이션 하였다. 이송 가이드 장치는 주로 3/2 방향 수동제어밸브와 5/2 방향 수동제어밸브 그리고 8개의 복동 실린더를 사용하였고 공압 회로를 완성하여 실제 제작하였다. 이송 장치의 한 사이클 작동시간은 46.48초로 계측되었고 가이드 장치의 작동으로 인한 작업장내의 추가적인 환경소음진동의 유발은 없는 것으로 나타나 제작된 장치가 설계사양을 만족함을 검증하였다. 본 결과는 2006년도에 특허출원 되었다.

다중 제어밸브 구조의 압력제어기 설계에 관한 연구 (A study on the pressure controller design of multiple control valve structure)

  • 신석신;박종호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.404-408
    • /
    • 2013
  • 본 연구에서는, 대형 증기유량이 요구되는 플랜트에서 정밀한 압력제어의 요구를 충족시키기 위한 다른 방법으로 3단계의 다중 제어밸브 구조를 이용하여 압력을 제어하는 제어기를 설계하는 내용이다. 본 연구의 핵심은 전기 유압시스템 외부에 별도의 PID 제어기를 이용하여 제어밸브의 위치를 정확하게 제어하는 것이다. 시뮬레이션 및 실험을 통해 제어기의 성능을 검증한다.

스크러버 연계 배기가스 배출제어용 3방향 댐퍼밸브의 구조 안전성 평가 (Structural Safety Evaluation of a 3-way Damper Valve for Scrubber-linked Exhaust Gas Control)

  • 김영훈
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.1007-1014
    • /
    • 2020
  • IMO(International Maritime Organization) continues to strengthen environmental regulations on exhaust gases such as CO2, NOx, SOx. As for sulfur oxides, from 1 January 2020, all ships on international voyages must use fuel with a sulfur content of 0.5% or less. Or, it is obligatory to use an exhaust gas treatment device that has the same effect. Shipping companies are using low-sulfur oil, replacing them with LNG fuel, or installing scrubbers that suppress sulfur oxide emissions. In the case of ships using bunker C oil, the load on the engine is lower when entering and departing, so the exhaust gas pressure is lowered and the scrubber cannot be properly utilized. Therefore, diesel oil with low sulfur content is used when entering and leaving the coast. When diesel oil is used, exhaust gas is directly discharged through the control system and piping system, and when bunker C oil is used, sulfur oxides are reduced by scrubbers through other control systems and piping systems to discharge exhaust gas. Accordingly, a company has developed a system called a three-way damper valve that can control exhaust gas emissions while integrating these two control systems and piping systems into one. In this study, the control characteristics of the integrated exhaust gas control system and structural safety against external loads in a high-temperature exhaust gas environment were reviewed.

태양광 모듈이 부착된 PTC 집열기 및 3웨이 밸브를 이용한 온열 시스템 설계 (Design of thermal system using 3-way valve and PTC to which a solar module)

  • 송제호;이인상;이유엽
    • 한국산학기술학회논문지
    • /
    • 제18권1호
    • /
    • pp.454-459
    • /
    • 2017
  • 본 논문에서는 최근 매장량의 한계로 인한 화석연료의 가격 상승과 그에 따른 환경적인 문제를 해결하고자 태양광 모듈이 부착된 PTC 집열기 및 3웨이 밸브를 이용한 온열 시스템을 설계 하고자 한다. 온열 시스템은 태양광 모듈이 부착된 태양열 PTC 집열기 사용을 전제로 3웨이 밸브를 이용한 온풍 및 난방 제어 시스템으로써 온도 센서부, 모드 설정부(온풍 및 난방 모드부), 공급부, 온열 시스템 제어부를 포함하여 구성된다. 온도 센서부는 배관 및 실내 온도 표시, 온도 설정부 다중 모니터링 기능이 있으며 모드 설정부는 온풍 및 난방모드 전환, 온풍 및 난방모드 온도 설정 기능을 수행한다. 또한, 온열 시스템 제어부는 PTC 제어 및 온도 설정, PTC 주야 및 시간 선택, 온풍 및 난방 제어, 3웨이 밸브 선택, 등의 기능을 수행한다. 따라서, 태양광 모듈이 부착된 태양열 PTC 집열기 및 3웨이 밸브을 이용한 온열 시스템 설계에 대한 연구 결과 온도 센서부는 $680{\mu}s$, 모드 설정부는 $700{\mu}s$, 온열 시스템 제어부는 $610{\mu}s$의 안정적인 동작 속도로 구동되는 것을 확인 할 수 있었다.

LOW FUEL CONSUMPTION AND LOW EMISSIONS - ELECTROMECHANICAL VALVE TRAIN IN VEHICLE OPERATION

  • Pischinger, M.;Salber, W.;Staay, F.V.D.;Baumgarten, H.;Kemper, H.
    • International Journal of Automotive Technology
    • /
    • 제1권1호
    • /
    • pp.17-25
    • /
    • 2000
  • The electromechanical valve train (EMV) technology allows for a reduction in fuel consumption while operating under a stoichiometric air-fuel-ratio and preserves the ability to use conventional exhaust gas aftertreatment technology with a 3-way-catalyst. Compared with an engine with a camshaft-driven valve train, the variable valve timing concept makes possible an additional optimization of cold start, warm-up and transient operation. In contrast with the conventionally throttled engine, optimized control of load and in-cylinder gas movement can be used for each individual cylinder and engine cycle. A load control strategy using a "Late Intake Valve Open" (LIO) provides a reduction in start-up HC emissions of approximately 60%. Due to reduced wall-wetting, the LIO control strategy improves the transition from start to idle. "Late Exhaust Valve Open" (LEO) timing during the exhaust stroke leads to exhaust gas afterburning and, thereby, results in high exhaust gas temperatures and low HC emissions. Vehicle investigations have demonstrated an improved accuracy of the air-fuel-ratio during transient operation. Results in the New European Driving Cycle have confirmed a reduction in fuel consumption of more than 15% while meeting EURO IV emission limits.

  • PDF

Design of a Two-Dimensional Proportional Solenoid for Miniature Directional Control Pneumatic Valves

  • Hong, Yeh-Sun;Ha, Dong-Hyun;Yeom, Myung-Ki
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.978-985
    • /
    • 2003
  • In this paper, a new proportional solenoid invented for pneumatic directional control valves is introduced. The new proportional solenoid has two-dimensional structure and a pivoting armature on which the friction force is inherently negligible. Another advantageous feature of this solenoid is that its mechanical parts can be easily manufactured and assembled. The working principle and design example of the now proportional solenoid, its application to the activation of a 4/3-way directional control valve, and the evaluation of its control performance in a position control loop are reported.

공동현상 가시화 실험을 통한 절환밸브 바텀플러그 형상 최적화 (Cavitation Visualization Test for Shape Optimization of Bottom Plug in Reversing Valve)

  • 김태안;이명곤;한승호
    • 대한기계학회논문집A
    • /
    • 제40권11호
    • /
    • pp.913-918
    • /
    • 2016
  • 자동차 엔진과 변속기 블록 등의 가공과정에서 잔류하는 기름때를 제거하기 위한 부품 세척장비는 정교한 제어장치 없이도 정확한 수류방향 절환이 원활히 이루지는 3 방향 절환밸브를 사용한다. 그러나, 밸브의 복잡한 유로 및 바텀플러그 형상으로 인해 유속변화가 심하게 발생하여 공동현상이 나타날 수 있다. 본 연구에서는 3 방향 절환밸브 내의 유동특성을 해석적으로 평가하였으며, 바텀플러그 하부에서 나타나는 공동현상을 공동화지표와 POC(Percent of cavitation)를 도입하여 정량화하였다. 공동현상의 저감을 위해 바텀플러그 형상을 매개변수화하고, 해석의 수렴성 개선과 해석시간을 단축시킬 수 있는 단순 유한요소모델을 이용하여 유동해석을 통한 형상최적설계를 실시하였다. 또한, 연구팀에서 보유하고 있는 유동시험설비와 ISA-RP75.23 규격에 맞게 제작된 시편을 이용하여 공동현상 가시화 실험을 실시하여 해석결과를 검증하였다.

차동PWM방식에 의한 유압실린더의 위치제어 (Position Control of a Hydraulic Cylinder by a Differential PWM Method)

  • 권기수;이창돈;이진걸
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권4호
    • /
    • pp.54-69
    • /
    • 1991
  • This study deals with the position control of a hydraulic cylinder system operated by two port 3-way high speed solenoid valve in Pulse-Width-Modulation mode, instead of using conventional electro-hydraulic servovalve. Due to the complexity and the relatively poor reliability of the servovalve, an actuator using simpler and more study high speed solenoid valve will be presented. The high speed solenoid valve acts as converters of electronic pulse signal to hydraulic ones. It has been pointed out that there are practical problems to be solved in the PWM system, that is (1) accuracy of positioning control becomes considerably insufficient because the system is affected by on/off action of the solenoid valves, and (2) serious nonlinerality appears in the valve characteristics as a result of the switching behavior of the valves. As a method to overcome these defects, the differential PWM driving method of a hydraulic cylinder that improved the steady-state-error, flow rate nonlinearity in simple PWM, and the hydraulic hunting of dead time compensated-PWM driving is proposed in this study.

  • PDF

제동장치에서 고주파수 PWM 제어에 의한 맥동특성 연구 (Study on the Characteristics of Surge Pressure by High Frequency PWM Control in Braking System)

  • 김병우
    • 한국정밀공학회지
    • /
    • 제25권3호
    • /
    • pp.109-114
    • /
    • 2008
  • The solenoid valve of ABS hydraulic modulator is a two directional on-off valve and is controlled by around 100Hz on-off control. When the on-off valve is switched from open state to closed state, there are braking force deterioration, noise and vibration due to surge pressure in the wheel cylinder. In this study, identifies surge pressure in the braking process of ABS, and investigates the way to reduce the phenomenon. To reduce the surge pressure, PWM(Pulse Width Modulation) control with high frequency of 20kHz was attempted. In conclusion, by using the results of this study for the pressure surge prediction, we could expect enhancement of braking performance in ABS.