• 제목/요약/키워드: 3-way Mixing Valve

검색결과 1건 처리시간 0.015초

주거건물의 급탕방식별 급수.급탕헤더시스템 적용방안에 관한 연구 (A Study on the Application Method of Cold & Hot Water Manifold System for Hot Water Supply System in Residential Buildings)

  • 차민철;제성호;석호태
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.79-88
    • /
    • 2008
  • Hot water is used by having a wash, dishes, taking tub and drinking water in residential buildings, and the use objective is to raise comfort of human body sense, washing and sterilization effect and so on. Cold & hot water supply system is understanded simpler than HVAC systems relatively, so it is true that pace of performance improvement is slower than other systems for plan and technical development. In this study, the performance evaluations are conducted under the condition of composition ratio by 1:1 for cold & hot water supply manifold system using functionally complex valves such as constant flow regulating valve and 3-way mixing valve in the area of $105.6m^2$ apartment which consist of the largest part of the whole apartment. Also, flow rate related to simultaneous use of faucets and change of hot water temperature are compared with the existing method.