• 제목/요약/키워드: 3-mask

Search Result 1,005, Processing Time 0.033 seconds

Dry Etching of Flexible Polycarbonate and PMMA in O2/SF6/CH4 Discharges (O2/SF6/CH4 플라즈마를 이용한 플렉시블 Polycarbonate와 PMMA의 건식 식각)

  • Joo, Y.W.;Park, Y.H.;Noh, H.S.;Kim, J.K.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.85-91
    • /
    • 2009
  • There has been a rapid progress for flexible polymer-based MEMS(Microelectromechanical Systems) technology. Polycarbonate (PC) and Poly Methyl Methacrylate (PMMA), so-called acrylic, have many advantages for optical, non-toxic and micro-device application. We studied dry etching of PC and PMMA as a function of % gas ratio in the $O_2/SF_6/CH_4$ temary plasma. A photoresist pattern was defined on the polymer samples with a mask using a conventional lithography. Plasma etching was done at 100 W RIE chuck power and 10 sccm total gas flow rate. The etch rates of PMMA were typically 2 times higher than those of PC in the whole experimental range. The result would be related to higher melting point of PC compared to that of PMMA. The highest etch rates of PMMA and PC were found in the $O_2/SF_6$ discharges among $O_2/SF_6$, $O_2/CH_4$ and $SF_6/CH_4$ and $O_2/SF_6/CH_4$ plasma composition (PC: ${\sim}350\;nm/min$ at 5 sccm $O_2/5$ sccm $SF_6$, PMMA: ${\sim}570\;nm/min$ at 2.5 sccm $O_2/7.5$ sccm $SF_6$). PC has smoother surface morphology than PMMA after etching in the $O_2/SF_6/CH_4$ discharges. The surface roughness of PC was in the range of 1.9$\sim$3.88 nm. However, that of PMMA was 17.3$\sim$26.1 nm.

The Survey of Dentists: Updated Knowledge about Basic Life support and Experiences of Dental Emergency in Korea

  • Cho, Kyoung-Ah;Kim, Hyuk;Lee, Brian Seonghwa;Kwon, Woon-Yong;Kim, Mi-Seon;Seo, Kwang-Suk;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.1
    • /
    • pp.17-27
    • /
    • 2014
  • Background: Various medical emergency situations can occur during dental practices. Cardiac arrest is known to comprise approximately 1% of emergency situation. Thus, it is necessary for dentists to be able to perform cardiopulmonary resuscitation (CPR) to increase the chance of saving patient's life in emergency situation. In this paper, we conducted a survey study to evaluate to what extent dentists actually understood CPR practice and if they had experience in handling emergency situations in practice. Method: The survey was done for members of the Korean Dental Society of Anesthesiology (KDSA), who had great interest in CPR and for whom survey-by-mail was convenient. We had selected 472 members of the KDSA with a dental license and whose office address and contact information were appropriate, and sent them a survey questionnaire by mail asking about the degree of their CPR understanding and if they had experience of handling emergency questions before. Statistical analyses -frequency analysis, chi-square test, ANOVA, and so on- were performed by use of IBM SPSS Statistics 19 for each question. Result: Among 472 people, 181 responded (38.4% response rate). Among the respondents were 134 male and 47 female dentists. Their average age was $40.4{\pm}8.4$. In terms of practice type, there were 123 private practitioners (68.0%), 20 professors (11.0%), 16 dentists-in-service (8.8%), 13 residents (specialist training) (7.2%) and 9 military doctors (5%). There were 125 dentists (69.1%) who were specialists or receiving training to be specialist, most of whom were oral surgeon (57, 31.5%) and pediatric dentists (56, 30.9%). There were 153 people (85.0%) who received CPR training before, and 65 of them (35.9%) were receiving regular training. When asked about the ratio of chest pressure vs mouth-to-mouth respiration when conducting CPR, 107 people (59.1%) answered 30:2. However, only 27.1% of them answered correctly for a question regarding CPR stages, C(Circulation)- A(Airway)- B(Breathing)- D(Defibrillation), which was defined in revised 2010 CPR practice guideline. Dentists who had experience of handling emergency situations in their practice were 119 (65.6%). The kinds of emergency situations they experienced were syncope (68, 37.6%), allergic reactions to local anesthetic (44, 24.3%), hyperventilation (43, 23.8%), seizure (25, 13.8%), hypoglycemia (15, 8.3%), breathing difficulty (14, 7.8%), cardiac arrest (11, 6.1%), airway obstruction (6, 3.3%), intake of foreign material and angina pectoris (4, 2.2%), in order of frequency. Most respondents answered that they handled the situation appropriately under the given emergency situation. In terms of emergency equipment they had blood pressure device (70.2%), pulse oximetry (69.6%), Bag-Valve-Mask (56.9%), emergency medicine (41.4%), intubation kit (29.8%), automated external defibrillator (23.2%), suction kit (19.3%) and 12 people (6.6%) did not have any equipment. In terms of confidence in handling emergency situation, with 1-10 point scale, their response was $4.86{\pm}2.41$ points. The average point of those who received regular training was $5.92{\pm}2.20$, while those who did not was $4.29{\pm}2.29$ points (P<0.001) Conclusion: The result showed they had good knowledge of CPR but the information they had was not up-to-date. Also, they were frequently exposed to the risk of emergency situation during their dental practice but the level of confidence in handling the emergency situation was intermediate. Therefore, regular training of CPR to prepare them for handling emergency situation is deemed necessary.

Technical Review of Target Volume Delineation on the Posterior Fossa Tumor : An Optimal Head and Neck Position (후두와 종양의 방사선치료 시 표적용적의 결정을 위한 적절한 치료자세 연구)

  • Yoon Sang Min;Lee Sang-wook;Ahn Seung Do;Kim Jong Hoon;YE Byong Yong;Ra Young Shin;Kim Tae Hyung;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.94-99
    • /
    • 2003
  • Purpose : To explore a 3D conformal radiotherapy technique for a posterior fossa boost, and the potential advantages of a prone position for such radiotherapy. Materials and Methods :A CT simulator and 3D conformal radiotherapy Planning system was used for the posterior fossa boost treatment on a 13-year-old medulloblastoma patient. He was placed In the prone position and Immobilized with an aquaplast mask and immobilization mold. CT scans were obtained of the brain from the top of the skull to the lower neck, with IV contrast enhancement. The target volume and normal structures were delineated on each slice, with treatment planning peformed using non-coplanar conformal beams. Results : The CT scans, and treatment In the prone position, were peformed successfully. In the prone position, the definition of the target volume was made easier due to the well enhanced tentorium, In audition, the posterior fossa was located anteriorly, and with the greater choice of beam arrangements, more accurate treatment planning was possible as the primary beams were not obstructed by the treatment table. Conclusion : .A posterior fossa boost, in the prone position, Is feasible in cooperating patients, but further evaluation is needed to define the optimal and most comfortable treatment positions.

CT Simulation Technique for Craniospinal Irradiation in Supine Position (전산화단층촬영모의치료장치를 이용한 배와위 두개척수 방사선치료 계획)

  • Lee, Suk;Kim, Yong-Bae;Kwon, Soo-Il;Chu, Sung-Sil;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.165-171
    • /
    • 2002
  • Purpose : In order to perform craniospinal irradiation (CSI) in the supine position on patients who are unable to lie in the prone position, a new simulation technique using a CT simulator was developed and its availability was evaluated. Materials and Method : A CT simulator and a 3-D conformal treatment planning system were used to develop CSI in the supine position. The head and neck were immobilized with a thermoplastic mask in the supine position and the entire body was immobilized with a Vac-Loc. A volumetrie image was then obtained using the CT simulator. In order to improve the reproducibility of the patients' setup, datum lines and points were marked on the head and the body. Virtual fluoroscopy was peformed with the removal of visual obstacles such as the treatment table or the immobilization devices. After the virtual simulation, the treatment isocenters of each field were marked on the body and the immobilization devices at the conventional simulation room. Each treatment field was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR)/digitally composite radiography (DCR) images from the virtual simulation. The port verification films from the first treatment were also compared with the DRR/DCR images for a geometrical verification. Results : CSI in the supine position was successfully peformed in 9 patients. It required less than 20 minutes to construct the immobilization device and to obtain the whole body volumetric images. This made it possible to not only reduce the patients' inconvenience, but also to eliminate the position change variables during the long conventional simulation process. In addition, by obtaining the CT volumetric image, critical organs, such as the eyeballs and spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. The differences between the DRRs and the portal films were less than 3 mm in the vertebral contour. Conclusion : CSI in the supine position is feasible in patients who cannot lie on prone position, such as pediatric patienta under the age of 4 years, patients with a poor general condition, or patients with a tracheostomy.

Histamine Bronchial Provocation Test -Timed Tidal Breathing Technique- (히스타민 기관지유발 검사 -일정시간 흡입법-)

  • Chung, Yeon-Tae;Won, Kyung-Sook;Park, Hae-Shim
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.3
    • /
    • pp.270-276
    • /
    • 1994
  • Background: The measurement of nonspecific bronchial hyperreactivity is valuable for diagnosis and management of bronchial asthma. Methacholine or histamine is used for the pharmacologic provocation test. Usually a methacholine bronchial provocation test is performed by a dosing technique with counted number of breaths. A dosimeter is indispensable in the dosing technique. Recently a timed tidal breathing technique which dose not need an expensive dosimeter was introduced. We measured the degree of nonspecific bronchial hyperreactivity to histamine using a simple timed tidal breathing technique. Method: Forty two healthy volunteers, 12 patients with bronchial asthma(BA), 10 patients with rhinitis(RH) and 10 patients with upper respiratory infection(URI) participated in the study. The subject's nose was clipped and inhalation continued during tidal breathing for 2 minutes via a face mask. $FEV_1$ was measured at 30 seconds, 90 seconds after inhalation and inhalation of next solution was continued until there was a fall in $FEV_1$ of 20%. Histamine PC20 was defined as the concentration at 20% fall of $FEV_1$ and it was obtained from the log dose-response curve by linear interpolation. Results: Inhalation of serial dilution of histamine could be performed in all patients without significant side effects. The geometric mean${\pm}$standard deviation of histamine PC20 in healthy volunteers is $8.27{\pm}2.22mg/ml$, BA group $0.33{\pm}3.02mg/ml$, RH group $0.85{\pm}3.24mg/ml$, and URI group $1.47{\pm}1.98mg/ml$. Conclusion: Histamine bronchial provocation test using timed tidal breath method is a simple and suitable tool for management of patients with bronchial hyperreactivity.

  • PDF

Evaluation of Foodservice Hygiene in Middle School Students by Meal Service Area in Busan (배식장소에 따른 부산지역 일부 중학생의 급식위생 평가)

  • Kim, Yeo Kyeong;Choi, Hee Sun;Lyu, Eun Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.1
    • /
    • pp.145-151
    • /
    • 2015
  • The purpose of this study was to evaluate foodservice hygiene in middle school students by analyzing the importance and performance of school foodservice by meal service area in Busan. Questionnaires were administered to 826 students in 10 middle schools (five schools for classroom service, five schools for dining room service). The average importance and performance scores were 4.11/5.00 and 3.38/5.00 for classroom service and 4.34/5.00 and 3.89/5.00 for dining room service. Dining room service had significantly (P<0.001) higher average scores importance and performance of food hygiene, environment hygiene, equipment hygiene, and employee hygiene than those of classroom service. The gap average score of dining room service was significantly (P<0.001) lower than those of classroom service. In the importance-performance analysis, 'cleanliness of tray' showed high importance and low performance for classroom service and dining room service. Areas of low importance and low performance were 'tray drying', 'cleanliness of employee' clothes', 'wearing sanitary gown, cap', 'wearing sanitary mask', and 'wearing sanitary gloves' for the classroom service, whereas 'tray drying', 'comfortable atmosphere in diningroom', 'well ventilated', 'no odor of the food in classroom', and 'cleanliness around rubbish bins' were relevant for dining room service. These findings suggest that employee hygiene management should be intensively managed for classroom service, and equipment hygiene management must be improved for classroom service and dining room service, especially cleanliness of tray. Meal service places should be changed to the dining room with support the government and private sector.

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.

Exposure Assessment of Apple Orchard Workers to the Insecticide Imidacloprid Using Whole Body Dosimetry During Mixing/Loading and Application (전신복장법을 이용한 농약 조제 및 살포 과정 중 살충제 Imidacloprid에 대한 사과 과수원 농작업자의 노출 평가)

  • Lee, Jae Yun;Noh, Hyun Ho;Park, Hyo Kyoung;Jeong, Hye Rim;Jin, Me Jee;Park, Kyung-Hun;Kim, Jeong-Han;Kyung, Kee Sung
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.3
    • /
    • pp.271-279
    • /
    • 2016
  • To evaluate exposure characteristics of the insecticide imidacloprid to apple orchard workers during treatment on orchard fields and evaluate its potential risk using a whole body dosimetry (WBD) method, 1,000-time diluted acephate+imidacloprid 25(20+5)% solutions were sprayed on 10 apple orchard fields in Cheongju with a speed sprayer at a rate of 3,000 L/ha/person, after put on clothes such as inner/outer clothes, personal air pump with a IOM sampler, nitrile glove and mask. Exposure test included mixing, loading and application steps. The test pesticide imidacloprid residues in the collected samples were analyzed with a HPLC-DAD. Recoveries ranged from 81.5 to 108.6% for analytical method validation and from 73.8 to 86.7% for field recovery. Total exposed amounts to mixer/loader and applicator were found to be 0.0014-0.0279% of total applied active ingredient of imidacloprid. Glove exposure of both mixer/loader and applicator was higher than the other parts. Margins of safety of mixer/loader and applicator were calculated to be 97-355 and 46-196, respectively, indicating that exposure risk of imidacloprid to apple orchard workers by spraying with a speed sprayer was very low.

The Sensitivity Analysis according to Observed Frequency of Daily Composite Insolation based on COMS (관측 빈도에 따른 COMS 기반의 일 평균 일사량 산출의 민감도 분석)

  • Kim, Honghee;Lee, Kyeong-Sang;Seo, Minji;Choi, Sungwon;Sung, Noh-Hun;Lee, Darae;Jin, Donghyun;Kwon, Chaeyoung;Huh, Morang;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.733-739
    • /
    • 2016
  • Insolation is an major indicator variable that can serve as an energy source in earth system. It is important to monitor insolation content using remote sensing to evaluate the potential of solar energy. In this study, we performed sensitivity analysis of observed frequency on daily composite insolation over the Korean peninsula. We estimated INS through the channel data of Communication, Ocean and Meteorological Satellite (COMS) and Cloud Mask which have temporal resolution of 1 and 3 hours. We performed Hemispherical Integration by spatial resolution for meaning whole sky. And we performed daily composite insolation. And then we compared the accuracy of estimated COMS insolation data with pyranometer data from 37 points. As a result, there was no great sensitivity in the daily composite INS by observed frequency of satellite that accuracy of the calculated insolation at 1 hour interval was $28.6401W/m^2$ and 3 hours interval was $30.4960W/m^2$. However, there was a great difference in the space distribution of two other INS data by observed frequency of clouds. So, we performed sensitivity analysis with observed frequency of clouds and distinction between the two other INS data. Consequently, there was showed sensitivity up to $19.4392W/m^2$.