• Title/Summary/Keyword: 3-mask

Search Result 1,005, Processing Time 0.03 seconds

The Lines Extraction and Analysis of The Palm using Morphological Information of The Hand and Contour Tracking Method (손의 형태학적 정보와 윤곽선 추적 기법을 이용한 손금 추출 및 분석)

  • Kim, Kwang-Baek
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.243-248
    • /
    • 2011
  • In this paper, we propose a new method to extract palm lines and read it with simple techniques from one photo. We use morphological information and 8-directional contour tracking algorithm. From the digitalized image, we transform original RGB information to YCbCr color model which is less sensitive to the brightness information. The palm region is extracted by simple threshold as Y:65~255, Cb:25~255, Cr:130~255 of skin color. Noise removal process is then followed with morphological information of the palm such that the palm area has more than quarter of the pixels and the rate of width vs height is more than 2:1 and 8-directional contour tracking algorithm. Then, the stretching algorithm and Sobel mask are applied to extract edges. Another morphological information that the meaningful edges(palm lines) have between 10 and 20 pixels is used to exclude noise edges and boundary lines of the hand from block binarized image. Main palm lines are extracted then by labeling method. This algorithm is quite effective even reading the palm from a photographed by a mobile phone, which suggests that this method could be used in various applications.

Design for Access Control System based on Voice Recognition for Infectious Disease Prevention (전염성 확산 차단을 위한 음성인식 기반의 출입통제시스템 설계)

  • Mun, Hyung-Jin;Han, Kun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.7
    • /
    • pp.19-24
    • /
    • 2020
  • WHO declared a global pandemic on March 11th for Corona 19. However, there is a situation where you have to go to building for face-to-face education or seminars for economic and social activities. The first check method of COVID-19 infection is to measure body temperature, so the primary entrance and exit is blocked for near-field body temperature measurement. However, since it is troublesome to check directly, thermal camera is installed at the entrance of the building, and body temperature is measured indirectly using the infrared camera to control access. In case of middle and high schools, universities, and lifelong education center, we need a system that is possible to interoperate with attendance checks and automatically recognizes whether to wear masks and can authenticate students. We proposed the system that is to confirm whether to wear a mask with a camera that is embedded in a smart mirror, and that authenticates the user through voice recognition of the user who wants to enter the building by using voice recognition technology and determines whether to enter them or not. The proposed system can check attendance if it is linked with near-field temperature measurement and attendance check APP of student's smart phone.

The Effects of Interrelationship after Wearing between Respirators and Glasses Simultaneously (안면부 여과식 방진 마스크와 안경 동시 착용 시 상호 영향)

  • Eoh, Won Souk;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.47-53
    • /
    • 2018
  • This study compares the interrelation of fit factor(FF) and visual acuity test by the order of wearing preference between Particulate filtering face piece respirators(PFFR) and glasses for 54 participants. Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA) or Visual acuity. We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038 and compared the result of preference of wearing order between respirators and glasses. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis, peason correlation(P=0.05) Fit factor was increased when the respirator was worn before wearing the glasses(p=0.000) and decreased for visual acuity(p=0.000) The negative correlation was showed between OH and Overall fit factor(r=-0.409, p=0.002). Among 54 participants, 11 participants(20.3%) were worn respirator before wearing glasses and 1 participant(1.9%) was worn glasses before wearing respirator. The overall fit test showed the higher level was investigated for the group of participants wearing respirator before wearing glasses in 6 exercises. Also, overall fit factor were increased when participants wore glasses prior to respirator(16.6) to respirator prior to glasses(36.6). Visual acuity were increased when participants wore respirator prior to glasses(93.8) to glasses prior to respirator(106.0). Finally, comparison result of overall fit factor and visual acuity were glasses first choice from mask first choice. The results showed that higher overall fit factor was investigate when the participants wore the respirator prior to glassess at all. The results implied that it is important to maintain the overall fit factor and visual acuity according to the consideration of OH for glasses fitting when worker wore respirator and glasses at the same time.

A Study for Individual Identification by Discriminating the Finger Face Image (손가락 면 영상 판별에 의한 개인 식별 연구)

  • Kim, Hee-Sung;Bae, Byung-Kyu
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.3
    • /
    • pp.378-391
    • /
    • 2010
  • In this paper, it is tested that an individual is able to be identified with finger face images and the results are presented. Special operators, FFG(Facet Function Gradient) masks by which the gradient of a facet function fit on a gray levels of image patches can be computed are used and a new procedure named F-algorithm is introduced to match the finger face images. The finger face image is divided into the equal subregions and each subregions are divided into equal patches with this algorithm. The FFG masks are used for convolution operation over each patch to produce scalar values. These values from a feature matrix, and the identity of fingers is determined by a norm of the elements of the feature matrices. The distribution of the norms shows conspicuous differences between the pairs of hand images of the same persons and the pairs of the different persons. This is a result to prove the ability of discrimination with the finger face image. An identification rate of 95.0% is obtained as a result of the test in which 500 hand images taken from 100 persons are processed through F-algorithm. It is affirmed that the finger face reveals to be such a good biometrics as other hand parts owing to the ability of discrimination and the identification rate.

Methodology for Quantitative Monitoring of Agricultural Worker Exposure to Pesticides (농작업자에 대한 농약 노출의 정량적 측정 방법)

  • Kim, Eun-Hye;Lee, Hye-Ri;Choi, Hoon;Moon, Joon-Kwan;Hong, Soon-Sung;Jeong, Mi-Hye;Park, Kyung-Hun;Lee, Hyo-Min;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.507-528
    • /
    • 2011
  • Agricultural workers who mix/loads and spray pesticide in fields expose to pesticide through dermal and inhalation routes. In such situation, exposed amount should be measured quantitatively for reasonable risk assessment. Patch, gloves, socks and mask will be good materials for monitoring for dermal exposure while personal air monitor equipped with solid adsorbent and air pump will be a tool for inhalation exposure. For extrapolation of absorbed amount in dermal exposure matrices and of trapped amount in solid sorbent to total deraml or inhalation exposure, Korean standard body surface area and respiration rate were proposed in substitution of EPA data. Important exposure factors such as clothing and skin penetration ratio of dermal and inhalation exposure were suggested based on Spraying time for exposure monitoring must be long enough that the amount of pesticide to get absorbed/trapped in exposure matrices results in reasonable analytical value. In domestic case for the both of speed sprayer and power spray machine, spraying time of 20~40 minutes (0.1~0.2 ha) will be reasonable per single replicate before extrapolating to 4 hours a day with triplicates experiment.

Fast information extraction algorithm for object-based MPEG-4 conversion from MPEG-1,2 (MPEG-1,2로부터 객체 기반 MPEG-4 변환을 위한 고속 정보 추출 알고리즘)

  • 양종호;박성욱
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.3
    • /
    • pp.91-102
    • /
    • 2004
  • In this paper, a fast information extraction algorithm for object-based MPEG-4 application from MPEG-1,2 is proposed. For object-based MPEG-4 conversion, we need to extract such information as object-image, shape-image, macro-block motion vector, and header information from MPEG-1,2 bit-stream. If we use the extracted information, fast conversion for object-based MPEG-4 is possible. The proposed object extraction algerian has two important steps, namely the motion vector extraction from MPEG-1,2 bit-stream and the watershed algerian The algorithm extracts objects using user's assistance in the intra frame and tracks then in the following inter frames. If we have an unsatisfactory result for a fast moving object the user can intervene to connect the segmentation. The proposed algorithm consist of two steps, which are intra frame object extracting processing and inter frame tracking processing. Object extracting process is the step in which user extracts a semantic object directly by using the block classification and watersheds. Object tracking process is the step of the following the object in the subsequent frames. It is based on the boundary fitting method using motion vector, object-mask and modified watersheds. Experimental results show that the proposed method can achieve a fast conversion from the MPEG-1,2 bit-stream to the object-based MPEG-4 input.

Automatic Skin Basal Cell Carcinoma Detection Using Protophorphyrin IX((PpIX) Fluorescence Image (PpIX 형광영상을 이용한 피부 기저세포암 자동검출)

  • Yu, Hong-Yeon;Jun, Do-Young;Kim, Min-Sung;Hong, Sung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.1
    • /
    • pp.47-54
    • /
    • 2008
  • In this paper, we propose an auto-detection algorithm of basal cell carcinoma(BCC) from the protophorphyrin IX(PpIX) fluorescence image induced by appling the methyl 5-aminolaevulinate(MAL) ointment-induced protophorphyrin IX(PpIX) to the skin tumour area and then shining the wood lamp on the area. The proposed algorithm first generates 3 mask areas-tumor area, suspected tumor area and tumor free area and then applies local watershed algorithm to the turner and the suspected tumor areas to make small watershed regions that include similar luminance value pixels. Next, small watershed regions are merged by hierarchical queue based fast region merging that uses the difference between the average luminance values of adjacent watershed regions as a region merging criterion and finally BCC regions are detected. 50 tissue samples are acquired from the tumour regions of 10 patients with BCC that are extracted by using the proposed algorithm and are performed pathological examination by expert dermatologist. Experiment result shows the rate of tumor detection from BCC lesion using presurgical in vivo of MAL-indeuced PpIX fluorescence has high sensitivity 94.1% and relatively high specificity 82.6%.

A Study on the level of Recognition and Practices of 119 Emergency Medical Technician about Infection Control (119구급대원의 감염관리에 대한 인지도와 수행도 관계 연구)

  • Yun, Hyeong-Wan;Jung, Ji-Yeon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.99-113
    • /
    • 2008
  • In order to protect Rescue 119 workers exposed on the spot from potential infection, this study identified their awareness and practices of infection control so that it could help preventing them from infection and also provide basic materials necessary for pre-hospital infection control. This study applied questionnaire survey to total 215 Rescue 119 workers at fire stations in Jeonbuk province, Jeonnam province and Gwangju city from July 14 to Sept. 14, 2006 for the benefit of data collection. The questionnaire about possible associations between awareness and practices of infection control consisted of total 46 times across 6 categories such as washing hands during emergency activities ; fluid therapy and injection ; respirator maintenance; individual hygienics ; disinfectant supplies and equipments maintenance ; and control of infectious wastes. And collected data were processed using SPSS statistic program to analyze frequency and percentage, mean and standard deviation, Pearson's correlation coefficient, t-test and one-way ANOVA. As a result, this study came to the following conclusions : In terms of awareness about infection control, our respondents showed highest awareness about infectious waste control, and also showed highest level of practices in washing hands during emergency activities. Throughout all domains, awareness means were higher than practice means. In particular, infectious waste control was the domain of significant differences between awareness and practices. In terms of associations between awareness and individual characteristics, it was found that female rescue worker group and hospital/general hospital career group (before joining the Rescue 119) showed significantly higher awareness on statistic level. In regard to associations between individual characteristics and practices, it was found that female rescue worker group showed higher level of practices than male group on statistic level. This study also analyzed correlations between rescue workers' awareness and practice of infection control. As a result, it was found that the higher awareness was in correlations with the higher practices across all 6 domains including washing hands. In addition, the higher awareness of a questionnaire item was in significantly positive correlations with the higher practice of other items. However, our respondents showed high awareness about anti-infection, but low practices in reality. This indicates necessity of devising possible solutions to improve the practices as much as awareness. Especially, it was noted that major reasons for insufficient practices of infection control guideline come from unhabituated practices and lack of supports for infection-preventing supplies and protective device (mask, etc). Hence, it is necessary to provide more infection-preventing supplies for local rescue workers sufficiently, in parallel with steady habituation of infection control. Furthermore, it is required to manage and study infection control policies even at pre-hospital step in efforts for effective infection control, education and activities.

  • PDF

Reduction of the residual stress of various oxide films for MEMS structure fabrication (MEMS 공정을 위한 여러 종류의 산화막의 잔류응력 제거 공정)

  • Yi, Sang-Woo;Kim, Sung-Un;Lee, Sang-Woo;Kim, Jong-Pal;Park, Sang-Jun;Lee, Sang-Chul;Cho, Dong-Il
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.265-273
    • /
    • 1999
  • Various oxide films are commonly used as a sacrificial layer or etch mask in the fabrication of microelectromechanical systems (MEMS). Large residual strain of these oxide films causes the wafer to bow, which can have detrimental effects on photolithography and other ensuing processes. This paper investigates the residual strain of tetraethoxysilane (TEOS), low temperature oxide (LTO), 7 wt% and 10 wt% phosphosilicate glass (PSG). Euler beams and a bent-beam strain sensor are used to measure the residual strain. A poly silicon layer is used as the sacrificial layer, which is selectively etched away by $XeF_2$. First, the residual strain of as-deposited films is measured, which is quite large. The residual strain of the films is also measured after annealing them not only at $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}$ and $800^{\circ}C$ in $N_2$ environment for 1 hour but also at the conditions for depositing a $2\;{\mu}m$ thick polysilicon at $585^{\circ}C$ and $625^{\circ}C$. Our results show that the 7 wt% PSG is best suited as the sacrificial layer for $2\;{\mu}$ thick polysilicon processes.

  • PDF

Capnographic Monitoring of End-Tidal Partial Pressure of Carbon Dioxide in Anesthetized Cinereous vultures (Aegypius monachus) (독수리(Aegypius monachus)의 흡입마취에서 Capnography를 이용한 호기말 이산화탄소분압 모니터링)

  • Park, Won-Kyu;Seok, Seong-Hoon;Park, Se-Jin;Lee, Seung-Yong;Kim, Young-Ki;Hwang, Jae-Min;Jeong, Dong-Hyuk;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.380-384
    • /
    • 2015
  • The relationships between end-tidal partial pressure of carbon dioxide ($P_{ET}CO_2$) and arterial partial pressure of carbon dioxide ($P_aCO_2$), and between $P_{ET}CO_2$ and blood pH in isoflurane-anesthetized cinereous vultures were evaluated. Nine cinereous vultures (weighing 7.3-9.5 kg) were anesthetized via mask with isoflurane, intubated, and connected to a mechanical ventilator. By mechanical ventilator, respiratory rate was altered to achieve a $P_{ET}CO_2$ randomly selected among 30 to 35 mmHg. $P_aCO_2$ and blood pH were determined in serial arterial samples and compared with concurrent $P_{ET}CO_2$ measured with a sidestream capnography. Thirty six samples, nine cinereous vultures were tested 4 times each, were used to determine correlations coefficients between $P_aCO_2$ and $P_{ET}CO_2$, and between $P_{ET}CO_2$ and blood pH. Strong correlations were observed between $P_aCO_2$ and $P_{ET}CO_2$ (r = 0.951, P = 0.000, y = 1.679x - 30.236, $R^2=0.905$) as well as between $P_{ET}CO_2$ and blood pH (r = -0.728, P = 0.000, y = -0.024x + 8.389, $R^2=0.530$) with Pearson's correlation coefficient and simple linear regression. These results suggest that the capnography used provided a sufficiently accurate estimation of $P_aCO_2$ and blood pH. Thus, the monitoring of $P_{ET}CO_2$ can be useful method to prevent hypoventilation for cinereous vultures receiving mechanical ventilation.