• Title/Summary/Keyword: 3-dimensional CT

Search Result 591, Processing Time 0.024 seconds

Tracheal Resection and End to End Anastomosis for Tracheal Stenosis in Children (기관절제 및 단단문합술에 의한 소아 기관협착증의 치료)

  • Choi, Jong-Ouck;Chung, Keun;Kim, Young-Hwoan;Kim, Hye-Jung;Park, Chan;Choi, Geon
    • Korean Journal of Bronchoesophagology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 1997
  • Background and Objectives : In children with tracheal stenosis, operative management remains a challenging problem due to difficulties of operative techniques and postoperative care. The purpose of this study was to determine the effectiveness of tracheal resection with end to end anastomosis as operative management for tracheal stenosis in children. Materials and Methods : 6 children with severe tracheal stenosis underwent tracheal resection with end to end anastomosis. Causes of stenosis were trauma in 1 case and prolonged intubation or tracheotomy in 5 cases. The diagnoses were made by radiologic evaluation (plain X-ray, CT, 3-Dimensional CT) and confirmed by direct laryngoscopy and ventilating bronchoscopy under general anesthesia. Thyroplasty and unilateral arytenoidectomy were performed in 1 case. Suprahyoid release was done in 1 case with severe adhesion. Decanulation was achieved following postoperative endoscopic examination and pulmonary function test. Postoperative physical and radiologic examinations were given at regular intervals. Results : Stenosis were improved from grade III grade I in 4 cases and from grade II to grade I in 2 cases. Decanulation was achieved on average postoperative 6 months in 5 cases, and 10 years in 1 case due to exertional dyspnea. There were 1 each case of immediate postoperative subcutaneous emphysema, pneumothorax and wound infection. Postoperative granulomas at anastomosis site were treated with laser vaporization under suspension laryngoscope and bronchoscope in 3 cases. There was 1 each case of delayed postoperative vocal cord palsy, aspiration pneumonia and loss of cough reflex. Conclusion In tracheal stenosis of children, tracheal resection with end to end anastomosis has good result with preservation of normal airway. Preoperative evaluation of local factors such as swallowing, vocal cord movement and cough reflex and general condition was important for successful treatment. As the cases in adults, authors considered this operation to be a curable operative management for tracheal stenosis.

  • PDF

Clinical Experience of Three Dimensional Conformal Radiation Therapy for Non-Small Cell Lung Cancer (비소세포성 폐암에서 3차원 입체조형 방사선 치료 성적)

  • Choi Eun Kyung;Lee Byong Yong;Kang One Chul;Nho Young Ju;Chung Weon Kuu;Ahn Seung Do;Kim Jong Hoon;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.265-274
    • /
    • 1998
  • Purpose : This prospective study has been conducted to assess the value of three dimensional conformal radiation therapy (3DCRT) for lung cancer and to determine its potential advantage over current treatment approaches. Specific aims of this study were to 1) find the most ideal 3DCRT technique 2) establish the maximum tolerance dose that can be delivered with 3DCRT and 3) identify patients at risk for development of radiation pneumonitis. Materials and Methods : Beginning in Nov. 1994, 95 patients with inoperable non-small cell lung cancer (stage I; 4, stage II; 1, stage IIIa; 14, stage IIIb; 76) were entered onto this 3D conformal trial Areas of known disease and elective nodal areas were initially treated to 45 Gy and then using 3DCRT technique 65 to 70 Gy of total dose were delivered to the gross disease. Sixty nine patients received 65 Gy of total dose and 26 received 70 Gy Seventy eight patients (82.1$\%$) also received concurrent MVP chemotherapy. 3DCRT plans were compared with 2D plans to assess the adequacy of dose delivery to target volume, dose volume histograms for normal tissue, and normal tissue complication Probabilities (NTCP). Results : Most of plans (78/95) were composed of non-coplanar multiple (4-8) fields. Coplanar segmented conformal therapy was used in 17 pateints, choosing the proper gantry angle which minimize normal lung exposure in each segment. 3DCRT gave the full dose to nearly 100$\%$ of the gross disease target volume in all patients. The mean NTCP for ipsilateral lung with 3DCRT (range; 0.17-0.43) was 68$\%$ of the mean NTCP with 2D treatment planning (range; 0.27-0.66). DVH analysis for heart showed that irradiated volume of heart could be significantly reduced by non-coplanar 3D approach especially in the case of left lower lobe lesion. Of 95 patients evaluable for response, 75 (79$\%$), showed major response including 25 (26$\%$) with complete responses and 50 (53$\%$) with partial responses. One and two rear overall survivals of stage III patients were 62.6$\%$ and 35.2$\%$ respectively. Twenty percent (19/95) of patients had pneumonitis; Eight patients had grade 1 pneumonitis and 11 other patients had grade 2. Comparison of the average of NTCP for lung showed a significant difference between patients with and without radiation pneumonitis. Average NTCP for Patients without complication was 62$\%$ of those with complications. Conclusions : This study showed that non-coplanar multiple fields (4-8) may be one of the ideal plans for 3DCRT for lung cancer. It also suggested that 3DCRT may provide superior delivery of high dose radiation with reduced risk to normal tissue and that NTCP can be used as a guideline for the dose escalation.

  • PDF

Airway Responses to Bronchoprovocation Using High-Resolution Computed Tomography in Patients with Bronchial Asthma (기관지천식환자에 있어서 고해상도 전산화단층촬영술을 이용한 기관지유발에 대한 기도의 반응)

  • Choi, Byoung-Whui;Kang, Yoon-Jeong;Ko, Hyung-Ki;Park, In-Won;Hue, Sung-Ho;Kim, Yang-Soo;Kim, Young-Goo;Kim, Kun-Sang;Kim, Jong-Hyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.813-822
    • /
    • 1995
  • Background: Bronchial hyperresponsiveness and abnormal response such as a loss of distensibility are pathophysiologic characteristics if bronchial asthma. The only means of direct in vivo measurement of airway size had been a tantalium bronchography, until high-resolution computed tomography(HRCT) enabled to measure noninvasively two dimensional airway area more accurately and reliably. Method: To investigate airway area responses to bronchial provocation with methacholine and evaluate the major sites of bronchial constriction in patients with bronchial asthma. We examined HRCT scans in five patients with bronchial asthma who had significant bronchoconstriction(20% or more decrease in $FEV_1$) using CT scanner(5,000T CT, Shimadzu Co, Japan) before and in 3~5 min. after methacholine inhalation. Airways which were matched by parenchymal anatomic landmarks in each patient before and after methacholine inhalation were measured using film scanner(TZ-3X scanner; Truvel Co. Chatsworth CA, USA) and a semiautomated region growing method. Results: 1) We identified 9 to 12 airways in each patient which were matched by parenchymal anatomic landmarks before and after methacholine inhalation. 2) Airway responses to methacholine are quite different even in a patient. 3) The constriction of small airways(average diameter <2 mm; area < $3.14mm^2$) was 48.7%(8.3; SEM, n=43), being more prominant than that of large airways(average diameter >2 mm; area > $3.14mm^2$), 53.8% (4.4;SEM, n=10), but not significantly different(p>0.05). 4) There was no significant difference in the degree of constriction between upper(44.3% +5.8; mean + SEM, n=30) and lower lung regions(56.7% +4.5, n=23). Conclusions: Thus airway responses to methacholine bronchoprovocation is quite variable in a patient with bronchial asthma and has no typical pattern in patients with bronchial asthma.

  • PDF

A Study on Developing Customized Bolus using 3D Printers (3D 프린터를 이용한 Customized Bolus 제작에 관한 연구)

  • Jung, Sang Min;Yang, Jin Ho;Lee, Seung Hyun;Kim, Jin Uk;Yeom, Du Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.61-71
    • /
    • 2015
  • Purpose : 3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. Materials and Methods : RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$ and $V_{95%}$ in treatment plan through Eclipse. Results : Customized bolus production period took about 3 days. The total volume of air gap was average $3.9cm^3$ at the customized bolus. And it was average $29.6cm^3$ at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. Conclusion : The customized bolus developed by 3D printers was effective in minimizing the air gap, especially when it is used against the treatment area with irregular surface. However, the air gap between branded bolus and skin was not enough to cause a change in target dose. On the other hand, in the chest wall could confirm that dose decrease for small the air gap. Customized bolus production period took about 3 days and the development cost was quite expensive. Therefore, the commercialization of customized bolus developed by 3D printers requires low-cost 3D printer materials, adequate for the use of bolus.

  • PDF

The influence of occlusal loads on stress distribution of cervical composite resin restorations: A three-dimensional finite element study (교합력이 치경부 복합레진 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Chan-Seok;Hur, Bock;Kim, Hyeon-Cheol;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.246-257
    • /
    • 2008
  • The purpose of this study was to investigate the influence of various occlusal loading sites and directions on the stress distribution of the cervical composite resin restorations of maxillary second premolar, using 3 dimensional (3D) finite element (FE) analysis. Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). HyperMesh (Altair Engineering. Inc., Troy, USA) and ANSYS (Swanson Analysis Systems. Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid (Z100, 3M Dental Products, St. Paul, MN, USA) or flowable resin (Tetric Flow, Viva dent Ets., FL-9494-Schaan, Liechtenstein) and each restoration was simulated with adhesive layer thickness ($40{\mu}m$). A static load of 200 N was applied on the three points of the buccal incline of the palatal cusp and oriented in $20^{\circ}$ increments, from vertical (long axis of the tooth) to oblique $40^{\circ}$ direction towards the buccal. The maximum principal stresses in the occlusal and cervical cavosurface margin and vertical section of buccal surfaces of notch-shaped class V cavity were analyzed using ANSYS. As the angle of loading direction increased, tensile stress increased. Loading site had little effect on it. Under same loading condition. Tetric Flow showed relatively lower stress than Z100 overall, except both point angles. Loading direction and the elastic modulus of restorative material seem to be important factor on the cervical restoration.

  • PDF

Application and effects of condylectomy in asymmetric patients with condylar hyperplasia (과두과증식을 동반한 안면비대칭 환자에서 과두절제술의 적용과 효과)

  • Lim, Kyoung-Sub;Cha, Jung-Yul;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.437-455
    • /
    • 2008
  • Condylar hyperplasia is a pathologic condition showing 3-dimensional skeletal hyperplasia of the mandible. The reason for condylar hyperplasia is not yet known, but the effects of hormone, trauma, infection, genetics, fetal condition, and hypervascularity are known as possible reasons. When we diagnose a patient as having condylar hyperplasia, it is important to decide if it is in progress or not. Treatment for facial asymmetry due to condylar hyperplasia are decided accordingly, including condylectomy, that is removal of growth site of the affected condyle, and conventional orthognathic surgery only or condylectomy with orthognathic surgery after the completion of growth. Therefore, it is important to determine the growth state of condylar hyperplasia in treatment stability. This is verified through bone scan and regular check-ups with 3D CT or PA cephalogram. This case report introduces an improved case of facial asymmetry with condylectomy together with orthognathic surgery.

Development of 2.5D Electron Dose Calculation Algorithm (2.5D 전자선 선량계산 알고리즘 개발)

  • 조병철;고영은;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, as a preliminary study for developing a full 3D electron dose calculation algorithm, We developed 2.5D electron dose calculation algorithm by extending 2D pencil-beam model to consider three dimensional geometry such as air-gap and obliquity appropriately. The dose calculation algorithm was implemented using the IDL5.2(Research Systems Inc., USA), For calculation of the Hogstrom's pencil-beam algorithm, the measured data of the central-axis depth-dose for 12 MeV(Siemens M6740) and the linear stopping power and the linear scattering power of water and air from ICRU report 35 was used. To evaluate the accuracy of the implemented program, we compared the calculated dose distribution with the film measurements in the three situations; the normal incident beam, the 45$^{\circ}$ oblique incident beam, and the beam incident on the pit-shaped phantom. As results, about 120 seconds had been required on the PC (Pentium III 450MHz) to calculate dose distribution of a single beam. It needs some optimizing methods to speed up the dose calculation. For the accuracy of dose calculation, in the case of the normal incident beam of the regular and irregular shaped field, at the rapid dose gradient region of penumbra, the errors were within $\pm$3 mm and the dose profiles were agreed within 5%. However, the discrepancy between the calculation and the measurement were about 10% for the oblique incident beam and the beam incident on the pit-shaped phantom. In conclusions, we expended 2D pencil-beam algorithm to take into account the three dimensional geometry of the patient. And also, as well as the dose calculation of irregular field, the irregular shaped body contour and the air-gap could be considered appropriately in the implemented program. In the near future, the more accurate algorithm will be implemented considering inhomogeneity correction using CT, and at that time, the program can be used as a tool for educational and research purpose. This study was supported by a grant (#HMP-98-G-1-016) of the HAN(Highly Advanced National) Project, Ministry of Health & Welfare, R.O.K.

  • PDF

Finite Element Analysis of Stress Distribution in using Face Mask according to Traction Point (훼이스 마스크의 견인위치에 따른 응력분포에 관한 유한요소법적 연구)

  • Oh, Kyo-chang;Cha, Kyung-Suk;Chung, Dong-hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.171-181
    • /
    • 2009
  • The objective of this study was to analyse stress distribution of maxillary complex by use of face mask. The construction of the three-dimensional FEM model was based on the computed tomography(CT) scans of 13.5 years-old male subject. The CT image were digitized and converted to the finite element model by using the mimics program, with PATRAN. An anteriorly directed force of 500g was applied at the first premolar 45 degrees downwards to the FH plane and at the first molar 20 degrees downwards to the FH plane. When 45 degrees force was applied at maxillary first premolar, there were observed expansion at molar part and constriction at premolar part. The largest displacement was 0.00011mm in the x-axis. In the y-axis, anterior displacement observed generally 0.00030mm at maximum. In the z-axis, maxillary complex was displaced 0.00036 mm forward and downward. When 20 degrees force was applied at maxilla first molar, there were observed expansion at lateral nasal wall and constriction at molar part. The largest displacement was 0.001mm in the X-axis. In the Y-axis, anterior displacement observed generally 0.004mm at maximum. In the Z-axis, ANS was displaced upward and pterygoid complex was displaced downward. The largest displacement was 0.002mm.

Analysis of Buildability and Strength Characteristics of Cement-based Composite Materials by Manufacturing Method of Laminated Specimens (적층시험체 제작 방식에 따른 시멘트계 복합재료의 적층성능 및 강도 특성 분석)

  • Eun-A Seo;Ho-Jae Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.9-15
    • /
    • 2023
  • In this study, the lamination performance and strength characteristics of cement-based composite materials according to the laminated specimens manufacturing method were analyzed. As a result of evaluating the buildability according to the layer height, the highest dimensional stability was shown when the layer height was 10 mm in all parts. The mold casting specimen and the printing-Z specimen showed the same compressive strength performance at the age of 28 days. On the other hand, the compressive strength at 28 day of printing-X specimen was the lowest at 71.72 MPa, and 8% lower than that of the mold casting specimen and the printing-Z specimen. The split tensile strength of the laminated specimen may show similar performance to that of the mold casting specimen, but the strength performance may decrease by more than 10% depending on the direction of the layer and the number of layers in the specimen. As a result of the interface analysis of the laminated specimen through X-ray CT analysis, it was confirmed that pores of a certain size were distributed along the interface of the layer.

Comparison of CT Volumetry and RECIST to Predict the Treatment Response and Overall Survival in Gastric Cancer Liver Metastases (위암 간전이 환자의 반응평가와 생존율 예측을 위한 종양 부피 측정과 RECIST 기준의 비교 연구)

  • Sung Hyun Yu;Seung Joon Choi;HeeYeon Noh;In seon Lee;So Hyun Park; Se Jong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.876-888
    • /
    • 2021
  • Purpose The aim of this study was to compare the diameter and volume of liver metastases on CT images in relation to overall survival and tumor response in patients with gastric cancer liver metastases (GCLM) treated with chemotherapy. Materials and Methods We recruited 43 patients with GCLM who underwent chemotherapy as a first-line treatment. We performed a three-dimensional quantification of the metastases for each patient. An independent survival analysis using the Response Evaluation Criteria in Solid Tumors (RECIST) was performed and compared to volumetric measurements. Overall survival was evaluated using Kaplan-Meier analysis and compared using Cox proportional hazard ratios following univariate analyses. Results When patients were classified as responders or non-responders based on volumetric criteria, the median overall survival was 23.6 months [95% confidence interval (CI), 8.63-38.57] and 7.6 months (95% CI, 3.78-11.42), respectively (p = 0.039). The volumetric analysis and RECIST of the non-progressing and progressing groups showed similar results based on the Kaplan-Meier method (p = 0.006) and the Cox proportional hazard model (p = 0.008). Conclusion Volumetric assessment of liver metastases could be an alternative predictor of overall survival for patients with GCLM treated with chemotherapy.