신체활동 비교를 통한 개인 맞춤형 신체활동 에너지 소비량 예측 알고리즘 (Personalized Prediction Algorithm of Physical Activity Energy Expenditure through Comparison of Physical Activity)

  • 김도윤;전소혜;배윤형;김남현
    • 대한안전경영과학회지
    • /
    • 제14권1호
    • /
    • pp.87-93
    • /
    • 2012
  • The purpose of this study suggests a personalized algorithm of physical activity energy expenditure prediction through comparison and analysis of individual physical activity. The research for a 3-axial accelerometer sensor has increased the role of physical activity in promoting health and preventing chronic disease has long been established. Estimating algorithm of physical activity energy expenditure was implemented by using a tri-axial accelerometer motion detector of the SVM(Signal Vector Magnitude) of 3-axis(x, y, z). A total of 10 participants(5 males and 5 females aged between 20 and 30 years). The activities protocol consisted of three types on treadmill; participants performed three treadmill activity at three speeds(3, 5, 8 km/h). These activities were repeated four weeks.

MEMS 임베디드 시스템 설계 (MEMS Embedded System Design)

  • 홍선학
    • 디지털산업정보학회논문지
    • /
    • 제18권4호
    • /
    • pp.47-54
    • /
    • 2022
  • In this paper, MEMS embedded system design implemented the sensor events via analyzing the characteristics that dynamically happened to an abnormal status in power IoT environments in order to guarantee a maintainable operation. We used three kinds of tools in this paper, at first Bluetooth Low Energy (BLE) technology which is a suitable protocol that provides a low data rate, low power consumption, and low-cost sensor applications. Secondly LSM6DSOX, a system-in-module containing a 3-axis digital accelerometer and gyroscope with low-power features for optimal motion. Thirdly BM1422AGMV Digital Magnetometer IC, a 3-axis magnetic sensor with an I2C interface and a magnetic measurable range of ±120 uT, which incorporates magneto-impedance elements to detect the magnetic field when the current flowed in the power devices. The proposed MEMS system was developed based on an nRF5340 System on Chip (SoC), previously compared to the standalone embedded system without bluetooth technology via mobile App. And also, MEMS embedded system with BLE 5.0 technology broadcasted the MEMS system status to Android mobile server. The experiment results enhanced the performance of MEMS system design by combination of sensors, BLE technology and mobile application.

모션 캡쳐를 위한 AHRS의 성능 향상 (Performance Improvement of an AHRS for Motion Capture)

  • 김민경;김태연;유준
    • 제어로봇시스템학회논문지
    • /
    • 제21권12호
    • /
    • pp.1167-1172
    • /
    • 2015
  • This paper describes the implementation of wearable AHRS for an electromagnetic motion capture system that can trace and analyze human motion on the principal nine axes of inertial sensors. The module provides a three-dimensional (3D) attitude and heading angles combining MEMS gyroscopes, accelerometers, and magnetometers based on the extended Kalman filter, and transmits the motion data to the 3D simulation via Wi-Fi to realize the unrestrained movement in open spaces. In particular, the accelerometer in AHRS is supposed to measure only the acceleration of gravity, but when a sensor moves with an external linear acceleration, the estimated linear acceleration could compensate the accelerometer data in order to improve the precision of measuring gravity direction. In addition, when an AHRS is attached in an arbitrary position of the human body, the compensation of the axis of rotation could improve the accuracy of the motion capture system.

Sensitivity Calibration 루틴 수행시 Tilt에 의한 방위각 측정 오차의 분석 (Analysis of Measured Azimuth Error on Sensitivity Calibration Routine)

  • 우광준;강수민
    • 전자공학회논문지SC
    • /
    • 제48권1호
    • /
    • pp.1-8
    • /
    • 2011
  • MR 센서에 의해 지구자기장의 세기를 측정하여 방위각을 결정하는 전자 Compass의 정밀도는 MR센서 및 OP-Amp.의 온도 Drift, DC Offset등 소자에 의한 오차, 측정주변 자성체에 의한 자기장의 왜곡, 및 Compass Tilt에 의한 오차 등의 영향을 받는다. 본 연구에서는 Set/Reset Pulse 방법에 의해 MR 센서 및 OP-Amp의 온도 Drift 및 DC Offset에 의한 오차를 해결하였고, 주변 자성체에 의한 자기장의 왜곡에 의한 오차를 Hard-Iron Calibration 루틴 수행에 의해 보상하였으며, Compass Tilt에 의한 오차를 Euler Rotational Equation에 의해 보상할 수 있는 3축 MR 센서 및 3축 Accelerometer를 기반으로 하는 전자 Compass 를 설계하였다. 특히 이와 샅이 설계한 전자 Compass를 가지고 3측 MR 센서의 서로 다른 Sensitivity와 OP-Amp.의 서로 다른 Gain등을 규준화하기 위한 Sensitivity Calibration 루틴 수행 시 Tilt의 발생으로 야기되는 오차를 정량적으로 분석하였으며, 이를 바탕으로 $1^{\circ}$정도(精度) Compass를 설계할 수 있었다.

3축 가속도를 이용한 활동상태 분류 시스템 구현 및 알고리즘 개발 (System Implementation and Algorithm Development for Classification of the Activity States Using 3 Axial Accelerometer)

  • 노윤홍;예수영;정도운
    • 한국전기전자재료학회논문지
    • /
    • 제24권1호
    • /
    • pp.81-88
    • /
    • 2011
  • A real time monitoring system from a PC has been developed which can be accessed through transmitted data, which incorporates an established low powered transport system equipped with a single chip combined with wireless sensor network technology from a three-axis acceleration sensor. In order to distinguish between static posture and dynamic posture, the extracted parameter from the rapidly transmitted data needs differentiation of movement and activity structures and status for an accurate measurement. When results interpret a static formation, statistics referring to each respective formation, known as the K-mean algorithm is utilized to carry out a determination of detailed positioning, and when results alter towards dynamic activity, fuzzy algorithm (fuzzy categorizer), which is the relationship between speed and ISVM, is used to categorize activity levels into 4 stages. Also, the ISVM is calculated with the instrumented acceleration speed on the running machine according to various speeds and its relationship with kinetic energy goes through correlation analysis. With the evaluation of the proposed system, the accuracy level stands at 100% at a static formation and also a 96.79% accuracy with kinetic energy and we can easily determine the energy consumption through the relationship between ISVM and kinetic energy.

빔 위치변화에 따른 4빔 압저항형 실리콘 가속도 센서의 제조 및 특성비교 (Fabrication and Characteristics Comparison of Piezoresistive Four Beam Silicon Accelerometer Based on Beam Location)

  • 신현옥;손승현;최시영
    • 전자공학회논문지D
    • /
    • 제36D권7호
    • /
    • pp.26-33
    • /
    • 1999
  • 4빔 브릿지형 압저항형 실리콘 가속도 센서에서 빔의 위치가 가속도 센서의 특성에 어떤 영향을 주는지 조사하기 위해서 빔의 위치가 서로 다른 3가지 형태의 가속도 센서를 FEM(finite element method)을 사용하여 해석하고, SDB(silicon direct bonding) 웨이퍼를 사용하여 RIE(reactive ion etching)와 KOH(potassium hydroxide) 애칭 공정으로 제조하였다. 세가지 형태의 가속도 센서에 대한 FEM 해석 경과, 첫 번째 공진 주파수와 Z축 감도는 세구조 모두 같게 나타났으나, 두 번째와 세 번째의 공진 주파수 및 X, Y축의 감도는 다른 것으로 나타났다. 제조된 가속도 센서의 특성을 살펴볼 때, 세 가지 형태의 센서는 비록 첫 번째 공진 주파수와 Z축 감도가 정확하게 일치하지는 않았지만, 첫 번째 공진 주파수는 1.3 ~ 1.7 KHz, Z축 감도는 5 V 인가시 180 ~ 220 lN/G, 타축감도는 1.7 ~ 2 %를 가지는 것으론 나타났다.

  • PDF

3축 가속도 센서를 이용한 증강현실 기반의 동적 상태변환 알고리즘 (Augmented Reality based Dynamic State Transition Algorithm using the 3-Axis Accelerometer Sensor)

  • 장유나;박성준
    • 한국콘텐츠학회논문지
    • /
    • 제10권10호
    • /
    • pp.86-93
    • /
    • 2010
  • 스마트폰의 도입으로 인하여 증강현실이 널리 알려짐에 따라 대중들의 관심은 이에 집중되고 있으며 휴대성으로 인하여 모바일기기에서의 증강현실 연구가 하나의 흐름으로 자리 잡고 있다. 기존의 증강 현실 관련 응용 기술들이 많이 연구되고 있지만 실제 게임에서 사용되고 있는 인공 지능과 결합된 연구는 이루어지고 있지 않다. 본 논문에서는 스마트 폰의 기능중 하나인 3축 가속도 센서를 이용하여 증강 현실 환경에서 3D 에이전트의 상태를 동적으로 변환하는 인공 지능 알고리즘을 제안한다. 인공지능이 적용된 에이전트의 상태를 제어하기 위한 전통적인 방식은 사용자가 직접 입력해 주거나 이를 인식하는데 마커를 사용하여 해결하였다. 정확한 상태 변환을 위하여 가속도 센서의 값에 임계값을 주었으며 임계값은 실험을 통하여 결정되었다. 본 논문에서는 증강 현실 구현을 위해 마커리스 추적 기술을 사용하였고 3축 가속도 센서를 이용하여 동적으로 에이전트의 상태를 변환하도록 하였다.

착용형 센서와 헬멧을 이용한 작업자의 작업환경 모니터링 (Work Environment Monitoring of Workers Using Wearable Sensor and Helmet)

  • 구예진;김종진;정완영
    • 융합신호처리학회논문지
    • /
    • 제20권2호
    • /
    • pp.91-98
    • /
    • 2019
  • 해상과 같이 고립된 장소에서 발생하는 작업자의 사고는 일반적인 건설 사고와는 달리 통신의 제한 등의 문제로 구조에 어려움이 따른다. 또한 CCTV의 부재로 인한 사고 현장의 수색에 어려움이 생긴다. 이러한 문제점을 개선하기 위해 이 논문에서는 작업 현장에서 필수적으로 착용해야 하는 안전모에 IoT 기술을 접목한 장치를 제안한다. 제안 장치는 기존의 안전모에 심박센서, 체온 센서, 가속도 센서 및 카메라 센서를 부착하여 설계 및 구현하며, 사용자 및 관제 센터에서 작업자의 상태를 모니터링 할 수 있게 한다. 또한 작업자에게 비정상적인 생체 신호나 낙상이 발생하면 영상을 관제센터로 전송한다. 제안 시스템을 활용하면 작업자의 상태를 실시간으로 확인할 수 있으므로 작업자의 사고에 대해 빠른 대처를 할 수 있는 장점을 가진다.

데이터 글로브를 이용한 3차원 손동작 인식 (3-D Hand Motion Recognition Using Data Glove)

  • 김지환;박진우;;김태성
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2009년도 학술대회
    • /
    • pp.324-329
    • /
    • 2009
  • Proactive computing의 핵심 기술인 손동작 인식 (Hand Motion Recognition, HMR) 기술은 인간과 컴퓨터 사이의 상호작용(Human Computer Interaction, HCI) 분야에서 많은 연구가 진행되고 있다. 본 연구에서는 3축 가속도 센서를 부착한 data glove를 제작하고, 3차원 손 모델을 구현한 후, 이를 이용한 손동작 인식 기술을 개발하였다. Data glove는 가상현실에 대한 입력 장치로써 본 논문에서는 3축 가속도 센서를 사용하여 획득된 신호를 wireless communication으로 PC에 전송할 수 있도록 구현하였다. 손 모델링은 ellipsoid를 이용한 kinematic chain 이론 바탕의 3차원 손 모델을 구현하였으며, data glove에서 얻어진 가속도 정보에 rule 기반의 알고리즘을 적용하여 구현된 3차원 손 모델을 통하여 간단한 손동작(가위, 바위, 보)을 인식하였다.

  • PDF

치과용 X-선 관구의 조정시간 (Settling time of dental x-ray tube head after positioning)

  • 윤숙자;강병철;왕세명;고창성
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.159-165
    • /
    • 2002
  • Purpose: The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. Materials and Methods: An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X -axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. Results : The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 1 I seconds for the mobile-types. Conclusion: Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after x-ray tube head positioning for better radiographic resolution.