• 제목/요약/키워드: 3-Terminal Electrodes

검색결과 16건 처리시간 0.024초

탄소접지극이 병설된 접지그리드의 접지임피던스의 해석 (Analysis of the Ground Impedance of Ground Grids Combined with the Carbon Ground Electrodes)

  • 이복희;엄상현;김유하;이강수;전병욱;최종혁
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.36-42
    • /
    • 2013
  • This paper deals with the frequency-dependent ground impedance of ground grids combined with the carbon ground electrodes. Ground grids are generally valid for multipurpose grounding systems as well as lightning protection systems. The carbon ground electrodes may be supplementarily used to reduce the high frequency ground impedance and to improve the transient response to surge currents. The frequency-dependent ground impedances of ground grids combined with or without the carbon ground electrodes were measured and their simulations with due regard to frequency-dependent soil resistivity were implemented by using EMTP program and Matlab modeling. As a consequence, the ground impedance of ground grids combined with the carbon ground electrodes is significantly reduced when the test current is injected at the terminal of the carbon ground electrode. The measured and simulated data for the test ground grids fairly agree with each other. It was found that the proposed method of simulating the frequency-dependent ground impedance is distinguished. The simulation techniques of predicting accurately the ground impedances without actual measurements can be used in the design of grounding systems based on ground grids and the carbon ground electrodes.

Enhancement of electrical characteristics and reliability of CuGeS2/GeS2-based super-linear-threshold-switching device by insertion of TiN liner

  • Hea-Jee Kim;Hyo-Jun Kwon;Dong-Hyun Park;Jea-Gun Park
    • Journal of the Korean Physical Society
    • /
    • 제80권
    • /
    • pp.1076-1080
    • /
    • 2022
  • For preventing a sneak current in the 3D cross-point array, the selection device is essentially necessary and an n-MOSFET has been used for the selection device. However, the three-terminal electrodes of n-MOSFET make to achieve a high density of a cross-point array difficult. As a solution, using a selector having two terminal electrodes has been intensively researched. We presented that the CuGeS2/GeS2-based super-linear-threshold-switching (SLTS) selector device with the insertion of optimal TiN liner thickness exhibited outstanding electrical characteristics and reliability. The dependency of electrical characteristics and reliability on various TiN liner thicknesses were investigated. In addition, the principles of reliability and electrical characteristics improvement were understood through the energy dispersive spectroscopy elemental mapping and line profile of Cu. The adequate amount of Cu distributed in GeS2 resistive switching layer is a key factor to achieve excellent electrical characteristics and reliability for an ultra-high-density 3D cross-point array cell.

Cross Capacitance 원리를 작용한 새로운 유전상수 측정방법 제안 (A New Measurement Method of Dielectric Constants Applied the Principles of Cross Capacitance)

  • 김한준;이래덕;강전흥;유광민;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1084-1087
    • /
    • 2002
  • The guard-ring type 3-terminal parallel plate electrodes proposed by ASTM D 150-81 and IEC 250 have been widely used for measurement of dielectric constants of solid dielectrics. However the method using this electrodes causes many uncertainty associated with the measurement errors of the diameter of the guarded electrode. the gap between guarded and guard-ring electrode. the distance of two active electrodes(the thickness of specimen), the roughness and contamination of surface of electrode and specimen. close adherence grade of electrode and specimen. In this paper. a new electrode system of cross capacitance type based on Thompson-Lampard theorem is designed and is employed for the measurement of dielectric constant. The results of simulation of guard-ring electrode and cross capacitance electrode using FEM program show that distance measurement between two electrodes in guard-ring electrode produces large uncertainty. on the other hand this effect in cross capacitance electrode is negligible. Furthermore. the air gap effects in the cross capacitance electrode is 5.6 times less sensitive than that in guard-ring electrode by assuming air gap of $50{\mu}m$.

  • PDF

3전극형 전기용량 센서를 이용한 변압기 절연유의 열화감지특성 평가 (Analysis on the Diagnosis Characteristics of Electrical Insulating Oil for Power Transformer with 3-terminal Capacitive Sensor)

  • 김주한;서판석;김필환;김명환;박흥석;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.89-92
    • /
    • 2004
  • This paper described the capacitive sensor for the diagnosis of deterioration of electrical insulating oils applying guard-ring type the 3-terminal electrodes. To measure stable capacitance of the sensor and to determine the design factors of the sensor, we utilized computational analysis, FEM software. This capacitive sensor discern the extent of deterioration measuring relative permittivity of electrical insulating oils. The result of measuring numerous sample, mineral oils, as serviced year, we confirmed an increase in relative permittivity of oils. Moreover, we confirmed the superior characteristics of the sensor as a species, aged pattern of oils and operating temperature.

  • PDF

전기 절연유 열화진단을 위한 3-단자식 전기용량 센서 개발 및 진단특성 평가 (Development and Evaluation of 3-terminal Type Capacitive Sensor for the Diagnosis of Electrical Insulating Oil)

  • 김주한;한상옥
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.476-482
    • /
    • 2009
  • This paper describes the development of capacitive sensor for the diagnosis of liquid dielectrics, which is widely used as the electrical insulating oil of transformer, circuit breaker, cable and etc. To survey the dielectric properties of the virgin and aged electrical insulating oils, we utilized the highly precise measuring system, using the principle of cross capacitance. The measured properties were used to determine the design factors of the sensor. Then the factors were optimized with the help of computational analysis. To evaluate diagnosis by the sensor, we performed accelerated thermal aging test about electrical insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. And to evaluate the hysteresis characteristics with the change of temperature, we constructed a testing system, which was composed with vacuum drying oven, oil chamber and measuring instruments, such as LCR meter, MUX and so forth. Through the results of this investigation, we confirmed the superior characteristics of the newly developed sensor.

유두체 손상이 시상전핵 조직상의 미세구조에 미치는 영향 (Ultrastructural Changes in the Neuropil of the Anterior Thalamic Nucleus following the Lesion in the Mamillary Body)

  • 이병호;고정식;안의태;양남길
    • Applied Microscopy
    • /
    • 제18권2호
    • /
    • pp.177-186
    • /
    • 1988
  • Degeneration of the axon terminals of mamillo-thalamic tract following the electrical coagulation of mamillary body is well known. In this study, the author investigated the ultrastructural alterations of neuropil components, initiated by terminal degenerations. Rats weighing approximately 250 gm were fixed on the stereotaxic instrument(David Kopf Inc., Heavy duty model), and NE 300 active electrode(Rhodes Med. Instr. Inc.) was introduced to the mamillary position of anterior 3.8 mm, lateral 0.5 mm, height 3.8 mm and lateral angle of $23^{\circ}$ according to De Groot's Atlas. Electric current of 20 mA was applied during 1 minute between active and inactive electrodes with Radio Frequency Lesion Generator(RFG 4, Radionics Inc.). Two hours, 2 days, 1 week and 2 weeks following the electrical coagulation of mamillary body, ipsilateral anterior thalamic nucleus was fixed in 1% glutaraldehyde-l% paraformaldehyde and 2% osmium tetroxide, embedded in Araldite mixture, cutted with LKB ultra tome V, stained with uranyl acetate-lead citrate and observed with JEOL 100 CX electron microscope. Observed results were as follows; 1. Degenerated mamillo-thalamic synapses were observed to form asymmetric axospinous or axo-dendritic types. 2. Terminal degeneration was not easily discernible at 2 hours interval after mamillary lesion, but following 2 days the terminal degeneration was apparent. 3. Postsynaptic spines, dendrites and even their cell bodies show edematic changes caused by the degeneration of postsynaptic counterpart. 4. Astrocytic territories, including perivascular processes forming glial limitans of blood-brain barrier, exhibit remarkable expansion. 5. Oligoglia and astroglia are actively engaged in the removal of degenerated elements. 6. Active forms of microglia were increased. 7. The observed results may represent typical ultrastructural alteration pattern within neuropil following the degeneration of certain input axon terminals.

  • PDF

전기 절연유의 열화 패턴에 따른 정전용량형 센서의 열화감지특성 평가 (Evaluation of Diagnosis Properties of Capacitive Sensor about Deteriorated Pattern of Electrical Insulating Oil)

  • 김주한;김재훈;이원영;김필환;한상옥;김한준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1829-1831
    • /
    • 2004
  • This paper described the capacitive sensor for the diagnosis of deterioration of electrical insulating oils applying guard-ring type the 3-terminal electrodes. To measure stable capacitance of the sensor and to determine the design factors of the sensor, we utilized computational analysis, FEM software. This capacitive sensor discern the extent of deterioration measuring relative permittivity of electrical insulating oils. The result of measuring numerous sample, mineral oils, as serviced year, we confirmed an increase in relative permittivity of oils. Moreover, we confirmed the superior characteristics of the sensor as a species, aged pattern of oils and operating temperature.

  • PDF

어종식별을 위한 광대역 초음파 변환기의 설계 -I - 전극분할형 압전진동자의 주파수특성 제어 - (The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Control of the Resonance Frequency of a Piezoelectric Transducer with Two Pair of Electodes -)

  • 이대재
    • 수산해양기술연구
    • /
    • 제33권3호
    • /
    • pp.183-188
    • /
    • 1997
  • 어종의 식별을 위한 음향학적 정보를 추출해 내는 데 활용하기 위한 초음파 변환기를 설계하기 위한 시도의 하나로꺼 전극분할 원반형 압전진동자를 이용하여 공진주파기를 가변시켜 넓은 주파수 대역에 걸쳐 사용할 수 있는 어군탐지기용 송.수파기를 설계하였다. 본 연구에서 설계한 초음파 변환기는 전극분할형 압전진동자의 한쪽 전극에 발전기를 접속하고, 다른 쪽 전국에 2.7~15.0 mH 인덕턴스를 접속하였을 때, 경방향에 대한 공진 주파스는 49.5~ 55.7 kHz의 범위에서 가변시킬 수 있었고, 또한 외부에서 진동자에 인가한 임피던스의 영향에 의해 출현하는 공진주파수에는 61.3~121.7 kHz의 범위에서 가변시킬수 있었다. 그러나, 이들 주파수에 대한 전기음향효율을 고려 할때, 실제로 활용할 수 있는 주파수 범위는 이것보다 훨씬 좁은 폭이 될 것이라 판단된다.

  • PDF

u-헬스케어 시스템에서 멀티 생체신호 측정 무선 단말기 설계 및 구현 (Design and Implementation of Mobiel Terminal with Multi Bio-signal Measurement for u-Healthcare System)

  • 장문석;엄수홍;김평수;이응혁
    • 재활복지공학회논문지
    • /
    • 제7권2호
    • /
    • pp.27-34
    • /
    • 2013
  • 기존의 u-헬스케어 시스템의 생체 신호 측정 단말기는 단말기에서 하나의 생체 신호를 측정하여 평가하는 것이 대부분이고, 복합된 기능의 단말기이더라도 사용자의 선택에 의해서 생체 신호를 측정하도록 되어 있다. 본 논문에서는 이러한 문제점을 해결하고, u-헬스케어 시스템에 적용하기 위한 멀티 생체신호 측정 무선 단말기를 구현하였다. 구현된 단말기는 4개의 적외선 센서를 사용하여 맥박수를 측정하고, 2개의 전극을 이용하여 피부전도도를 측정하고, 3축 가속도 센서를 사용하여 운동량을 측정하였다. 뿐만 아니라, 생체신호 데이터를 무선으로 전송하기 위해 지그비를 이용하여 PC 또는 휴대단말기로 전송할 수 있는 통신 패킷 프레임을 제안한다. 무선 단말기를 구현하여 실제 테스트한 결과 맥박 수는 2회 이내의 오차 범위를 가지고, 운동량은 약 85.6%, 84.7%의 신뢰도를 보였으며, 피부전도도는 사용자의 신체 상태에 따라 변화함을 알 수 있었다.

  • PDF