• Title/Summary/Keyword: 3-Terminal Electrodes

Search Result 15, Processing Time 0.027 seconds

Analysis of the Ground Impedance of Ground Grids Combined with the Carbon Ground Electrodes (탄소접지극이 병설된 접지그리드의 접지임피던스의 해석)

  • Lee, Bok-Hee;Um, Sang-Hyun;Kim, You-Ha;Lee, Kang-Soo;Jeon, Byung-Wook;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.36-42
    • /
    • 2013
  • This paper deals with the frequency-dependent ground impedance of ground grids combined with the carbon ground electrodes. Ground grids are generally valid for multipurpose grounding systems as well as lightning protection systems. The carbon ground electrodes may be supplementarily used to reduce the high frequency ground impedance and to improve the transient response to surge currents. The frequency-dependent ground impedances of ground grids combined with or without the carbon ground electrodes were measured and their simulations with due regard to frequency-dependent soil resistivity were implemented by using EMTP program and Matlab modeling. As a consequence, the ground impedance of ground grids combined with the carbon ground electrodes is significantly reduced when the test current is injected at the terminal of the carbon ground electrode. The measured and simulated data for the test ground grids fairly agree with each other. It was found that the proposed method of simulating the frequency-dependent ground impedance is distinguished. The simulation techniques of predicting accurately the ground impedances without actual measurements can be used in the design of grounding systems based on ground grids and the carbon ground electrodes.

A New Measurement Method of Dielectric Constants Applied the Principles of Cross Capacitance (Cross Capacitance 원리를 작용한 새로운 유전상수 측정방법 제안)

  • Kim, Han-Jun;Lee, Rae-Duk;Kang, Jeon-Hong;Yu, Kwang-Min;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1084-1087
    • /
    • 2002
  • The guard-ring type 3-terminal parallel plate electrodes proposed by ASTM D 150-81 and IEC 250 have been widely used for measurement of dielectric constants of solid dielectrics. However the method using this electrodes causes many uncertainty associated with the measurement errors of the diameter of the guarded electrode. the gap between guarded and guard-ring electrode. the distance of two active electrodes(the thickness of specimen), the roughness and contamination of surface of electrode and specimen. close adherence grade of electrode and specimen. In this paper. a new electrode system of cross capacitance type based on Thompson-Lampard theorem is designed and is employed for the measurement of dielectric constant. The results of simulation of guard-ring electrode and cross capacitance electrode using FEM program show that distance measurement between two electrodes in guard-ring electrode produces large uncertainty. on the other hand this effect in cross capacitance electrode is negligible. Furthermore. the air gap effects in the cross capacitance electrode is 5.6 times less sensitive than that in guard-ring electrode by assuming air gap of $50{\mu}m$.

  • PDF

Analysis on the Diagnosis Characteristics of Electrical Insulating Oil for Power Transformer with 3-terminal Capacitive Sensor (3전극형 전기용량 센서를 이용한 변압기 절연유의 열화감지특성 평가)

  • Kim, Ju-Han;Seo, Pan-Seok;Kim, Pil-Hwan;Kim, Myung-Hwan;Park, Hung-Seok;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.89-92
    • /
    • 2004
  • This paper described the capacitive sensor for the diagnosis of deterioration of electrical insulating oils applying guard-ring type the 3-terminal electrodes. To measure stable capacitance of the sensor and to determine the design factors of the sensor, we utilized computational analysis, FEM software. This capacitive sensor discern the extent of deterioration measuring relative permittivity of electrical insulating oils. The result of measuring numerous sample, mineral oils, as serviced year, we confirmed an increase in relative permittivity of oils. Moreover, we confirmed the superior characteristics of the sensor as a species, aged pattern of oils and operating temperature.

  • PDF

Development and Evaluation of 3-terminal Type Capacitive Sensor for the Diagnosis of Electrical Insulating Oil (전기 절연유 열화진단을 위한 3-단자식 전기용량 센서 개발 및 진단특성 평가)

  • Kim, Ju-Han;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.476-482
    • /
    • 2009
  • This paper describes the development of capacitive sensor for the diagnosis of liquid dielectrics, which is widely used as the electrical insulating oil of transformer, circuit breaker, cable and etc. To survey the dielectric properties of the virgin and aged electrical insulating oils, we utilized the highly precise measuring system, using the principle of cross capacitance. The measured properties were used to determine the design factors of the sensor. Then the factors were optimized with the help of computational analysis. To evaluate diagnosis by the sensor, we performed accelerated thermal aging test about electrical insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. And to evaluate the hysteresis characteristics with the change of temperature, we constructed a testing system, which was composed with vacuum drying oven, oil chamber and measuring instruments, such as LCR meter, MUX and so forth. Through the results of this investigation, we confirmed the superior characteristics of the newly developed sensor.

Ultrastructural Changes in the Neuropil of the Anterior Thalamic Nucleus following the Lesion in the Mamillary Body (유두체 손상이 시상전핵 조직상의 미세구조에 미치는 영향)

  • Lee, Byoung-Ho;Ko, Jeong-Sik;Ahn, E-Tay;Yang, Nam-Gil
    • Applied Microscopy
    • /
    • v.18 no.2
    • /
    • pp.177-186
    • /
    • 1988
  • Degeneration of the axon terminals of mamillo-thalamic tract following the electrical coagulation of mamillary body is well known. In this study, the author investigated the ultrastructural alterations of neuropil components, initiated by terminal degenerations. Rats weighing approximately 250 gm were fixed on the stereotaxic instrument(David Kopf Inc., Heavy duty model), and NE 300 active electrode(Rhodes Med. Instr. Inc.) was introduced to the mamillary position of anterior 3.8 mm, lateral 0.5 mm, height 3.8 mm and lateral angle of $23^{\circ}$ according to De Groot's Atlas. Electric current of 20 mA was applied during 1 minute between active and inactive electrodes with Radio Frequency Lesion Generator(RFG 4, Radionics Inc.). Two hours, 2 days, 1 week and 2 weeks following the electrical coagulation of mamillary body, ipsilateral anterior thalamic nucleus was fixed in 1% glutaraldehyde-l% paraformaldehyde and 2% osmium tetroxide, embedded in Araldite mixture, cutted with LKB ultra tome V, stained with uranyl acetate-lead citrate and observed with JEOL 100 CX electron microscope. Observed results were as follows; 1. Degenerated mamillo-thalamic synapses were observed to form asymmetric axospinous or axo-dendritic types. 2. Terminal degeneration was not easily discernible at 2 hours interval after mamillary lesion, but following 2 days the terminal degeneration was apparent. 3. Postsynaptic spines, dendrites and even their cell bodies show edematic changes caused by the degeneration of postsynaptic counterpart. 4. Astrocytic territories, including perivascular processes forming glial limitans of blood-brain barrier, exhibit remarkable expansion. 5. Oligoglia and astroglia are actively engaged in the removal of degenerated elements. 6. Active forms of microglia were increased. 7. The observed results may represent typical ultrastructural alteration pattern within neuropil following the degeneration of certain input axon terminals.

  • PDF

Evaluation of Diagnosis Properties of Capacitive Sensor about Deteriorated Pattern of Electrical Insulating Oil (전기 절연유의 열화 패턴에 따른 정전용량형 센서의 열화감지특성 평가)

  • Kim, Ju-Han;Kim, Jae-Hoon;Lee, Won-Yeong;Kim, Pil-Hwan;Han, Sang-Ok;Kim, Han-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1829-1831
    • /
    • 2004
  • This paper described the capacitive sensor for the diagnosis of deterioration of electrical insulating oils applying guard-ring type the 3-terminal electrodes. To measure stable capacitance of the sensor and to determine the design factors of the sensor, we utilized computational analysis, FEM software. This capacitive sensor discern the extent of deterioration measuring relative permittivity of electrical insulating oils. The result of measuring numerous sample, mineral oils, as serviced year, we confirmed an increase in relative permittivity of oils. Moreover, we confirmed the superior characteristics of the sensor as a species, aged pattern of oils and operating temperature.

  • PDF

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Control of the Resonance Frequency of a Piezoelectric Transducer with Two Pair of Electodes - (어종식별을 위한 광대역 초음파 변환기의 설계 -I - 전극분할형 압전진동자의 주파수특성 제어 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.183-188
    • /
    • 1997
  • A method for designing a broadband transducer was investigated experimentally. Control of the resonance frequency of a Piezoelectric circular transducer with two pairs of electrodes was achieved by varying the inductance of external coil connected across the terminal of one pair of electrodes of transducer. The conductance curves of transducer in water were obtained as a function of the inductance value in mH of the coil used in the tuning. As the tuning inductance is increased in value, the resonance frequency is reduced toward the fundamental frequency of 50 kHz. This interesting result suggest that it is possible to produce a continuously tunable transducer covering a frequency range between 61.3 kHz and 121.7 kHz by varying the inductance value of external coil from 2.7 mH to 15.0 mH. One of other problems in the design and construction of such broadband transducer is the transducer efficiency, but this will be the subject of our future work.

  • PDF

Design and Implementation of Mobiel Terminal with Multi Bio-signal Measurement for u-Healthcare System (u-헬스케어 시스템에서 멀티 생체신호 측정 무선 단말기 설계 및 구현)

  • Jang, M.S.;Eom, S.H.;Kim, P.S.;Lee, E.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.27-34
    • /
    • 2013
  • Most of existing biomedical signal measurement devices measure and evaluate biomedical signal only in a single device. Also, even if the device is multi-functional, those biomedical signals can be measured by selection of the user. In this paper, we implemented wristband-style biomedical signal measurement device for u-healthcare system to solve the problem above. Implemented device uses 4 infrared sensors to measure the pulse, 2 electrodes to measure the skin conductivity, and 3-axis accelerometer to measure momentum. Also, we propose a communication packet frame for transmitting biomedical signal data to PC or mobile device, using Zigbee. Studies show that our device has the error rate of less than twice for pulse measurement, 85.6%, 84.7% reliability for momentum measurement, and the skin conductivity has changed according to the user's physical status.

  • PDF

A Study on the Bubble Deformation and Departure Under DC Electric Field (직류전기장에 의한 기포의 변형과 이탈에 관한 연구)

  • 권영철;김무환;강인석;김석준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1518-1528
    • /
    • 1995
  • The deformation and departure processes of a bubble attached to the wall are studied experimentally and numerically to understand the phenomena of the nucleate boiling heat transfer enhancement under DC electric field. An air-bubble is injected in a dielectric liquid with different electric fields generated by changing three types of electrode system (Type 1,2 and 3) in the bubble generator. Experimental variables are the electric field strength and the distance and the shape of the electrodes under DC electric field. From experimental results, it is observed that the bubble under Dc electric field is elongated in the same direction as the electric field and the contact angle increases. For the parallel plate electrode which generates a uniform electric field, bubble departure volume doesn't seem to decrease within our experimental range. However, when a needle is raised a few millimeters from the lower electrode to make a nonuniform electric field around the needle, bubble departure volume decreases continuously with the increase of an applied voltage. The reduction effect of bubble departure volume is the most effective under a strong nonuniform electric field generated with Type 3. As the nonuniformity of the electric field due to the shape of a electrode increases, the terminal velocity and the acceleration of a bubble increase largely. For the comparison with visualization results, the deformation of a bubble attached to the electrode is carried out by a numerical method. Numerical results show good agreement qualitatively with experimental results.