• Title/Summary/Keyword: 3-D standard Value

Search Result 367, Processing Time 0.024 seconds

A study on the Plumbing system noise of closet bowl by water supply pressure (급수압에 따른 대변기 설비소음에 관한 연구)

  • Kim, Hang;Choi, Eun-Suk;Ko, Kwang-Pil;Gl, No-Gab;Lee, Tai-Gang;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.11-16
    • /
    • 2006
  • It appraises that use an indoor noise standard, a NC value which is a noise appraisal, a dB(A) value, a N value in foreign country because it doesn't yet ready an appraisal standard in domestic. Also, It appraises that the supply and drainage noise which could change water supply pressure, $4kg/cm^2,\;3kg/cm^2,\;2kg/cm^2,\;1.5kg/cm^2,\;1kg/cm^2$, bring about a noise and inquires how does noise level indicates according to each instruments. In case of a water supply pressure standard, $3kg/cm^2$, a C-605is $3{\sim}5dB(A)$ lower than another instruments in directly overhead stories. It appears that all of them is similar to level in directly under level except c-407(2)Analyzed the NC value, c-605is the lowest level, NC-50, of a water supply pressure, $4.0kg/cm^2$, c-407 is the highest level, NC-55.(3) In case of N value, which is one of water supply methods in Japan, it is the lowest level, N-55, of a water supply pressure, $4.0kg/cm^2$ same as NC value and C-407is the highest level, N-60.(4) In case of water supply that is likely to noise level, It appears 6dB(A) level gap each instruments, and C-605 is the lowest level, 63.9dB(A).

  • PDF

Measurement of Joint Aperture Using 3-D Laser Profilometer (3차원 레이저 측정기를 이용한 절리 간극의 측정)

  • 이희석;이연규;이희근
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.309-320
    • /
    • 2000
  • Aperture is an important parameter for determining the hydraulic characteristics of fractured media. In this study the topography of artificial rock joint surface was measured using 3D laser profilometer to analyze the aperture distribution. The initial aperture distribution was determined when the contact area became one percent of total joint surface. The initial aperture distribution of granite joint, with the mean value of 0.78 mm and the standard deviation of 0.34 mm was much different from that of the marble joint, with the mean value of 0.57 mm and the standard deviation of 0.26 mm. Apertures of both granite and marble showed normal distributions. Aperture distribution with the contact area of 25% was also analyzed. Mean value was decreased to one third compared to the initial aperture, but the standard deviation was decreased slightly. To determine the spatial correlation of the aperture distribution variogram analysis was carried out on the initial aperture data. Most experimental variograms were fitted well with exponential model. It is expected that the measured aperture characteristics can be used for stochastic analysis of fluid flow through rock joints.

  • PDF

METAMERISM IN COMPOSITE RESINS UNDER FIVE STANDARD ILLUMINANTS - D65, A, C, FCW AND TL84 (복합레진의 조건등색에 관한 연구)

  • Park, Ki-Jeong;Hwang, Yun-Chan;Kim, Sun-Ho;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.402-408
    • /
    • 2003
  • This study was done to present a criterion in selection of the most proper light sources and materials by measuring metamerism index(MI) of the light curing composite resins with spectrocolorimeter. Metamerism is defined when two objects appear to be the same color in one illuminant but different in another. This is due to the fact that they have different spectral curves that fail to match under the second illuminant. In this study, A1 & A3 shade of five light curing composite resins (Esthet-X, Filteck Z250, Filteck A110. Charisma. Vitalescence) were chosen based on Vita shade. Five samples were made for shade of each product with Teflon mold (diameter: 15mm, thickness: 2mm). Metamerism index of each samples on a Barium sulfate plate($L^{*}=96.54,{\;}a^{*}=0.19,{\;}b^{*}=0.01$) prepared for sample fixation were measured with spectrocolorimeter(Miniscan XE plus. Model 4000s. Hunter Lab. USA) by applying standard light source D^{65}, C. Fcw, TL84 and A. Standardization was done with reference standard(X=80.8, Y=85.7, Z=90.8) and light trap. The results were as follows. 1. Different resins with same Vita shade showed recognizable color difference (${\delta}E^{*}>2$). 2. All composites had MI below accepted value 0.5 between standard illuminant(D$_{65}$, C, & A) and below 1.5 under fluorescent condition (Fcw & TL84). 3. MI value between $D^{65}$ and A showed higher value than MI value between other source of light(p<0.01). 4. All resins except Z250 showed MI value that A3 is higher than A1 between $D^{65}$ and A(p<0.05).except Z250 showed MI value that A3 is higher than A1 between $D^{65}$ and A(p<0.05).

Development and Evaluation of the Usefulness for Hoffman Brain Phantom Based on 3D Printing Technique (3D 프린팅 기법 기반의 Hoffman Brain 팬텀 개발 및 유용성 평가)

  • Park, Hoon-Hee;Lee, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.441-446
    • /
    • 2019
  • The purpose of this paper is to recognize the usefulness of the Phantom produced with 3D printing technology by reproducing the original phantom with 3D printing technology. Using CT, we obtained information from the original phantom. The acquired file was printed by the SLA method of ABS materials. For inspection, SPECT/CT was used to obtain images. We filled the both Phantom with a solution mixed with 99mTcO4 1 mCi in 1 liter of water and acq uired images in accordance with the standard protocol. Using Image J, the SNR for each slice of the image was obtained. As a reference images, AC images were used. For the analysis of acquired images, ROI was set in the White mater and Gray mater sections of each image, and the average Intensity Value within the ROI were compared. According to the results of this study, 3D printed phantom's SNR is about 0.1 higher than the conventional phantom. And the ratio of Intensity Value was shown in the original 1 : 3.4, and the printed phantom was shown to be 1 : 3.2. Therefore, if Calibration Value is applied, It is assumed that it can be used as an alternative to the original.

Design and Analysis of an Interleaved Boundary Conduction Mode (BCM) Buck PFC Converter

  • Choi, Hangseok
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.641-648
    • /
    • 2014
  • This paper presents the design considerations and analysis for an interleaved boundary conduction mode power factor correction buck converter. A thorough analysis of the harmonic content of the AC line current is presented to examine the allowable voltage gain (K value) for meeting the EN61000-3-2, Class D standard while maximizing efficiency. The results of the harmonic analysis are used to derive the required value of K and therefore the output voltage necessary to meet the class D requirements for a given AC line voltage. The discussed design consideration and harmonic current analysis are verified on a 300W universal line experimental prototype converter with an 80V output. The measured efficiencies remain above 96% down to 20% of the full load. The input current harmonics also meet the IEC61000-3-2 (class D) standard.

Quantification of three-dimensional facial asymmetry for diagnosis and postoperative evaluation of orthognathic surgery

  • Cao, Hua-Lian;Kang, Moon-Ho;Lee, Jin-Yong;Park, Won-Jong;Choung, Han-Wool;Choung, Pill-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.17.1-17.11
    • /
    • 2020
  • Background: To evaluate the facial asymmetry, three-dimensional computed tomography (3D-CT) has been used widely. This study proposed a method to quantify facial asymmetry based on 3D-CT. Methods: The normal standard group consisted of twenty-five male subjects who had a balanced face and normal occlusion. Five anatomical landmarks were selected as reference points and ten anatomical landmarks were selected as measurement points to evaluate facial asymmetry. The formula of facial asymmetry index was designed by using the distances between the landmarks. The index value on a specific landmark indicated zero when the landmarks were located on the three-dimensional symmetric position. As the asymmetry of landmarks increased, the value of facial asymmetry index increased. For ten anatomical landmarks, the mean value of facial asymmetry index on each landmark was obtained in the normal standard group. Facial asymmetry index was applied to the patients who had undergone orthognathic surgery. Preoperative facial asymmetry and postoperative improvement were evaluated. Results: The reference facial asymmetry index on each landmark in the normal standard group was from 1.77 to 3.38. A polygonal chart was drawn to visualize the degree of asymmetry. In three patients who had undergone orthognathic surgery, it was checked that the method of facial asymmetry index showed the preoperative facial asymmetry and the postoperative improvement well. Conclusions: The current new facial asymmetry index could efficiently quantify the degree of facial asymmetry from 3D-CT. This method could be used as an evaluation standard for facial asymmetry analysis.

Development of a 3D Roughness Measurement System of Rock Joint Using Laser Type Displacement Meter (레이저 변위계를 이용한 암석 절리면의 3차원 거칠기 측정기 개발)

  • 배기윤;이정인
    • Tunnel and Underground Space
    • /
    • v.12 no.4
    • /
    • pp.268-276
    • /
    • 2002
  • In this study, a 3D coordinate measurement system equipped with a laser displacement meter for digitizing rock joint surface was established and the digitized data were used to calculate several roughness parameters. The parameters used in this study were micro avenge inclination $angle(i_{ave})$, average slope of joint $asperity(SL_{ ave})$, root mean square of $i-angle(i_{rms})$, standard deviation of height(SDH), standard deviation of $i-angle(SD_i)$, roughness profile $index(R_P)$, and fractal dimension(D). The relationships between the roughness parameters based on the digitzation of the surface profile were analyzed. Since the measured value varied according to the degree of reflection and the variation of colors at the measuring point, rock joint surface was painted in white to minimize the influence of the surface conditions. The comparison of the measured values and roughness parameters before and after painting revealed the better consequence from measurement on the painted surfaces. Also, effect of measuring interval was studied. As measured interval was increased, roughness parameters were exponentially decreased. The incremental sequence of degree of decrease was $SDH\; i_{ave},\; i_{rms},\; SD_i,\;and\; R_ p-1$. As a result of comparison of parameters from pin-type measurement system and laser type measurement system, all value of parameters were higher when laser-type measurement system was used, except SDH.

A Study on the Quality of Photometric Scanning Under Variable Illumination Conditions

  • Jeon, Hyoungjoon;Hafeez, Jahanzeb;Hamacher, Alaric;Lee, Seunghyun;Kwon, Soonchul
    • International journal of advanced smart convergence
    • /
    • v.6 no.4
    • /
    • pp.88-95
    • /
    • 2017
  • The conventional scan methods are based on a laser scanner and a depth camera, which requires high cost and complicated post-processing. Whereas in photometric scanning method, the 3D modeling data is acquired through multi-view images. This is advantageous compared to the other methods. The quality of a photometric 3D model depends on the environmental conditions or the object characteristics, but the quality is lower as compared to other methods. Therefore, various methods for improving the quality of photometric scanning are being studied. In this paper, we aim to investigate the effect of illumination conditions on the quality of photometric scanning data. To do this, 'Moai' statue is 3D printed with a size of $600(H){\times}1,000(V){\times}600(D)$. The printed object is photographed under the hard light and soft light environments. We obtained the modeling data by photometric scanning method and compared it with the ground truth of 'Moai'. The 'Point-to-Point' method used to analyseanalyze the modeling data using open source tool 'CloudCompare'. As a result of comparison, it is confirmed that the standard deviation value of the 3D model generated under the soft light is 0.090686 and the standard deviation value of the 3D model generated under the hard light is 0.039954. This proves that the higher quality 3D modeling data can be obtained in a hard light environment. The results of this paper are expected to be applied for the acquisition of high-quality data.

Sparkover Voltage Estimation of Standard Sphere Gaps for Negative Polarity by Calculation of Ionization Index

  • Nishikori, Yasuo;Kojima, Soji;Kouno, Teruya
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.2
    • /
    • pp.45-50
    • /
    • 2004
  • The field utilization factor (equation omitted) (the mean electric field / the maximum electric field) of standard sphere gaps was calculated by the charge simulation method, taking into account the ground plane and shanks. n changes mainly with g/r and slightly with 1$_1$, 1$_2$ and 1, where D=2r is the sphere diameter, g is the gap length, 1$_1$ and 1$_2$, respectively, are the lengths of the upper and lower shank, and t is the shank diameter. Generally, (equation omitted) increases as 1$_1$,1$_2$ and t each becomes larger. IEC standard 60052(2002) limits t$\leq$0.2D 1$_1$$\geq$1D and prescribes A=1$_2$+D+g where A is the height of the spark point on the upper sphere. Therefore, (equation omitted) is the largest when A=9D and the smallest when A=3D. The simple equation of a straight line, (equation omitted)=1- (g/3r), can generally be used as a representative value of (equation omitted) for a wide variety of sphere diameters that are permitted by the IEC standard. The maximum electric field E$_{m}$ at sparkover of standard air gaps has also been calculated by the relation E$_{m}$=V/(equation omitted)g). E$_{m}$ describes a U-curve for g/r, up to the sphere diameter of 1 m. Moreover, for 1.5-m and 2-m diameters and especially .for negative polarity, sparkover voltages have been calculated by integration of the ionization index.index.

Design of High Efficiency and Linearity Doherty Power Amplifier Using Adaptive Bias Technique and DGS for Wibro Applications (적응형 바이어스 기법과 DGS를 이용한 와이브로용 고효율 고선형 도허티 전력증폭기 설계)

  • Oh, Chung-Gyun;Son, Sung-Chan
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.8 no.1
    • /
    • pp.12-17
    • /
    • 2009
  • In this paper, We play it for the purpose of study about the power amplifier which applied DGS and adaptive bias circuit structure to general Doherty amplifier for the efficiency of a RF power amplifier and a linearity improvement in the WiBro band. As for the IMD3, 3.4dBc was improved with -26.3dBc when we did the measurement result existing Doherty power amplifier and comparison of the Doherty power amplifier which applied an adaptive bias circuit and the DGS which proposed in this paper, and the mean power efficiency verified what was increased in 37%. Also, we were able to know PAE of 36.6% with output power 34.0dBm in P1dB when magnitude of an input signal was 25.6dBm. we did 6dB back off in output P1dB in order to confirm the ACPR which was a nonlinear characteristic and measured the ACPR. we showed the -34.55dBc which was a value of -34.5dBc or below in the 4.77MHz off-set that was a transmission standard. Therefore, we were able to know that we were satisfied with a spectrum mask standard.

  • PDF