• 제목/요약/키워드: 3-D measuring instrument

검색결과 56건 처리시간 0.023초

3차원 계측장치를 이용한 길 원형의 여유량 분석 (Analysis of the Ease in Basic Bodice Pattern Using 3-D Measuring Instrument)

  • 심규남;서정권;이원자
    • 한국의류산업학회지
    • /
    • 제2권3호
    • /
    • pp.239-245
    • /
    • 2000
  • The purpose of this study was for analysis of ease about basic bodice pattern, as the first step of the research process for the drawing method of basic bodice for women in their twenties. The five selected basic bodice were made and they were worn by FRP body The garment space of each bodice was measured by analysis of the garment space of each section in figure of polymerization of cross section by a 3-D measuring instrument. The research suggests that this compared analysis is an objective reference. This analysis not only of the area of cross section of garment space and ease but also of the girth of the body shape and wearing shape, using the PAD system and 3-D measuring instrument, can be helpful in making garment patterns.

  • PDF

하이브리드 측정기의 개발 및 성능평가 (Development and Performance Evaluation of Hybrid Measuring Instrument)

  • 이영호;박기범;조영태;이응석;정윤교
    • 한국기계가공학회지
    • /
    • 제16권3호
    • /
    • pp.69-75
    • /
    • 2017
  • There are two types of expensive measuring instruments currently on the market shape measurement and roundness measurement instruments. As they are very expensive, from tens of millions to more than 200 million won, buying them is economically burdensome for small companies or individuals. Therefore, in order to integrate the shape and roundness measurements into a single transfer device, this study aimed to reduce the trial and error by 3D modeling and simulation, and we confirmed the feasibility of operation. Based on these outcomes, a prototype hybrid measuring instrument was fabricated. As a result of performance evaluation and comparative evaluation, we verified the feasibility of implementation and application of the hybrid measuring instrument.

3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구 (Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating)

  • 권석동;설유경;이의주;김규곤;김종원
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

3D 콘텐츠 깊이 측정기를 이용한 오브젝트의 돌출거리 측정 (Measuring Perceived Depth For The Object Using 3D Content Depth Measuring Instrument)

  • 한동희;강행봉;김석호
    • 한국멀티미디어학회논문지
    • /
    • 제16권9호
    • /
    • pp.1109-1118
    • /
    • 2013
  • 최근 들어 S3D 콘텐츠가 광범위하게 대중화되고 있다. 하지만, 일부의 사람들은 3D 정보를 정확하게 인지하지 못하고 있다. 기존의 입체시 검사 도구는 입체의 인지 여부를 판단하는 테스트만 수행하고, 피험자가 인지하는 정확한 깊이 정보를 측정할 수 없다. 따라서 정확하게 측정할 수 있는 검사도구가 필요하다. 본 논문에서는 3D 콘텐츠 깊이 측정기 및 측정기에 적합한 3D 콘텐츠를 제작하고, 3D 오브젝트의 양안시차(disparity)에 대한 피험자가 인지하는 3D 오브젝트의 돌출거리를 측정하고, 이론값(예측값)과 측정값을 비교 및 관계를 분석하였다. 그 결과 측정값은 이론값보다 약간 크게 나타났으며, 돌출거리가 클수록 편차가 크게 나타났다.

착의 단면 중합도 분석에 의한 길 원형의 여유률 산출 - 3차원 형상 계측기에 의한 - (Computation of Ease-Rate in Basic Bodice Pattern by Analysis of Multiple Cross Section, Using 3-D Measuring Instrument)

  • 심규남;김진선;이원자
    • 한국의류산업학회지
    • /
    • 제2권4호
    • /
    • pp.360-365
    • /
    • 2000
  • This research is the trial for the computation of the ease-rate for the bodice pattern. The result of the analysis about the cross section figures of garment space by using a 3-D measuring instrument is that: The garment space of each bodice by each body size is definite. In the figure of cross section of the basic lines, an area of cross section of garment space and length of cross section of garment space are not increased in proportion to an area of cross section of the body. The ease rate is the same no matter that flat-rate of the body is same or different. The ease-rate is computed by length of cross section of garment space that is in proportion to the radius of the body.

  • PDF

치과 3D 프린팅용 광중합 시간에 따른 중합도 비교 (Comparison of polymerization by time of light curing for dental 3D printing)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제44권3호
    • /
    • pp.76-80
    • /
    • 2022
  • Purpose: The purpose of this study is to analyze the depth according to curing using photocurable resin for dental three-dimensional printing. Methods: A stainless mold with a height of 4 mm was prepared. Ultraviolet (UV) polymerization resin was injected into the mold. Photocuring was then performed for 5 minutes using a photopolymerizer, and the height was measured using a digital measuring instrument (first group). Second, light polymerization was also performed outside the mold for 5 minutes, and the height was measured using a digital measuring instrument. Third, light polymerization was further performed for 5 minutes, and the height was measured using a digital measuring instrument. Statistical analysis was performed with the Kruskal-Wallis test, which is a nonparametric test (α=0.05). Results: The third group had the largest measurement length, whereas the first group had the smallest. However, the difference between groups was not statistically significant (p>0.05). The color of the first group was different from that of the second and third groups. Conclusion: All of the 4-mm-thick photocured specimens had a curing reaction, but the part that was not directly irradiated with UV did not show its original color.

기계시각을 이용한 분무입자크기 측정 (Machine Vision Instrument to Measure Spray Droplet Sizes)

  • 전홍영;티안레이
    • Journal of Biosystems Engineering
    • /
    • 제35권6호
    • /
    • pp.443-449
    • /
    • 2010
  • A machine vision-based instrument to measure a droplet size spectrum of a spray nozzle was developed and tested to evaluate its accuracy on measuring spray droplet sizes and classifying nozzle sizes. The instrument consisted of a machine vision, light emitting diode (LED) illumination and a desktop computer. The illumination and machine vision were controlled by the computer through a C++ program. The program controlled the machine vision to capture droplet images under controlled illumination, and processed the droplet images to characterize the droplet size distribution of a spray nozzle. An image processing algorithm was developed to improve the accuracy of the system by eliminating random noise and out-of-focus droplets in droplet images while measuring droplet sizes. The instrument measured sizes of the three different balls (254.0, 497.8 and $793.8\;{\mu}m$) and the measurement ranges were $241.2-273.6\;{\mu}m$, $492.9-529.6\;{\mu}m$ and $800.8-824.1\;{\mu}m$ for 254.0-, 497.84- and $793.75-\;{\mu}m$ balls, respectively. Error of the measured droplet mean was less than 3.0 %. Droplet statistics, $D_{V0.1}$, $D_{V0.5}$ and $D_{V0.9}$, of a reference nozzle set were measured, and droplet size spectra of five spray nozzles covering from very fine to extremely coarse were measured to classify spray nozzle sizes. Ninety percent of the classification results of the instrument agreed with manufacturer's classification. A comparison study was carried out between developed and commercial instruments, and measurement results of the developed instrument were within 20 % of commercial instrument results.

dB과 cm/sec간의 환산실험식 (Conversion Equation dB (Rion) to PPV(cm/sec))

  • 허진
    • 화약ㆍ발파
    • /
    • 제9권2호
    • /
    • pp.3-7
    • /
    • 1991
  • The Problem of vibration Inflence to housing Construction fields has arised at the begining of 1970, at That time I used Lion(VM -l2B) which recorded only dB Demension. On the 1980's I have been used lnstantel made blastemate(DS-477), modern Instrument for measuring speed, Acc, frequency and placement. but The most of Jobsite used Lion I Carried out the empirical equation of conversion dB to cm /sec as follows. Single free face : dB = 140PPV + 30 double free face : dB = 143PPV + 20 Above equation Could apply on Rock type 3(soft rock)

  • PDF

영상 및 레이저 계측기를 통한 경사면 상황인식 시스템 (Recognition System of Slope Condition Using Image and Laser Measuring Instrument)

  • 한상훈;한영준
    • 대한임베디드공학회논문지
    • /
    • 제9권4호
    • /
    • pp.219-227
    • /
    • 2014
  • Natural disasters such as a ground collapse and a landslide have broken out due to the climate change of the Korea and the reckless expansion of cities and roads. The climate changes and the reckless urbanization have made the ground weak. Thus, it is important to keep a close eye on the highly weakened landslide and to prevent its natural disasters. In order to prevent these disasters, this paper presents a system of recognizing the road slide condition by measuring the displacements using laser scanner instrument. The previous system of monitoring the road slide has some problems as inaccurate recognition due to using only images from a camera, or expensive system such as artificial satellites and aircraft systems. To solve this problem, our proposed system uses the 3D range data from the laser scanner for measuring the accurate displacement of the road slide and optical flows from the Lucas-Kanade algorithm for recognizing the road slide in the image.