• Title/Summary/Keyword: 3-D Contact

Search Result 987, Processing Time 0.028 seconds

Development of the Glandular Trichomes in Trapping Leaves of Drosera Species (끈끈이주걱속 점착식 포충엽의 분비모 발달)

  • Lee, Hye-Jin;Kim, In-Sun
    • Applied Microscopy
    • /
    • v.39 no.1
    • /
    • pp.57-64
    • /
    • 2009
  • The trapping leaves of Drosera capture insects by secreting sticky mucilage from numerous glandular trichomes (GTs) that are developed on the leaf epidermis. The present study examines and compares the structural features of those trichomes in Drosera binata and D. pygmy with the use of light and electron microscopy. The study focuses primarily on the development and differentiation pattern of the GTs during growth. Upon examination, the upper and lower epidermis were readily distinguishable by the features of GTs in developing leaves. In particular, the GTs were dense in the upper epidermis and along the leaf margin. In D. binata, the capitate GTs with elongated stalk and sessile peltate GTs were found most commonly, whereas only capitate GTs with varying degrees of the stalk length were observed in D. pygmy. Up to ca. $2.2{\sim}3.4\;mm$ long capitate GTs were seen in the leaf margins of D. binata and ca. $3.7{\sim}4.2\;mm$ long GTs having racket-like head with adaxial hemispheric structures, otherwise known as tentacles, were noted in the leaf margin of D. pygmy. The peltate GTs were found to be distributed in the lower epidermis of D. binata. In both species, head cells were dense with cytoplasm containing high numbers of Golgi bodies, ER, mitochondria and small vesicles. Secretory materials accumulated within numerous small vacuoles, then fused together to form a single large vacuole, which serves as a secretory cavity. Flection movement of the marginal GTs and leaf blade GTs, and increased mucilage secretion from the head cells upon contact with prey during the capturing process are considered to be major factors in their active insectivorous mechanism. The findings of this study will be useful in comparisons to similar findings in other species that form adhesive trapping leaves, such as Drosophyllum or Pinguicula., further contributing a better understanding of the function and structure of the trapping leaves of carnivorous plants.

Effect of Implant Length on the Immediate Loading at the Anterior Maxilla (즉시하중시 상악 전치부에 식립된 임플란트 길이 변화에 따른 응력 분포의 삼차원 유한요소 연구)

  • Lee, Joon-Seok;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.255-265
    • /
    • 2009
  • Recently many studies have been published on application of immediate loaded implants. However, the immediate loading protocol has not been well documented. The purpose of the present study was to evaluate the stress distribution between bone-implant interfaces and the effect of implant length in the anterior maxilla using 3 dimensional finite element analyses. The diameter 4.0 mm threaded type implants with different length(8.5 mm, 10.0 mm, 11.5 mm, 13.0 mm, 15.0 mm) were used in this study. The bone quality of anterior maxillary bone block was assumed to D3 bone. Bone-implant interfaces of immediately loaded implant were constructed using a contact element for simulating the non osseointegration status. For simplification of all the processing procedures, all of the material assumed to be homogenous, isotropic, and linearly elastic. The 178 N of static force was applied on the middle of the palatoincisal line angle of the abutment with $120^{\circ}$ angle to the long axis of abutment. Maximum von Mises stress were concentrated on the labial cortical bone of the implant neck area, especially at the cortical-cancellous bone interfaces. Compared the different length, highest peak stress value was observed at the 8.5 mm implants and the results indicated a tendency towards favorable stress distribution on the bone, when the length was increased. Presence of cortical bone was very important to immediate loading, and it appears that implants of a length more than 13 mm are preferable for immediate loading at the anterior maxilla.

Experimental Evaluation on Bond Strengths of Reinforcing Bar in Coils with Improved Machinability during Straightening Process (직선화 가공성을 고려한 코일철근의 실험적 부착강도 평가)

  • Chun, Sung-Chul;Choi, Oan-Chul;Jin, Jong-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • A new deformation of reinforcing bar in coils was proposed to improve a machinability of straightening process, which has crescent-shaped transverse ribs with an inclination angle of 50 degrees, a crest width of $0.15d_b$, and a flank inclination of 55 degrees. The proposed deformation can increase contact area between a surface of re-bar and a groove of a roller during a straightening process and, therefore, it might reduce a damage of ribs, improve a final straightness, and enhance an efficiency of the straightening process. Splice tests were conducted to evaluate bond strengths of three types of re-bar in coils including the proposed re-bar, of which the inclination angles of transverse ribs were 50, 60, and 90 degrees, respectively. Test results show that the re-bars in coils have higher bond strengths than predicted strengths by equations of Orangun et al., ACI 408, and KCI by at least 10%. Correlation coefficients of bond strengths between a straight bar and re-bars in coils are 0.94 and more. Consequently, equations of the KCI code for determining development and splice lengths can be applied to the tested re-bars in coils.

The Optimization of Ozone Solubility and Half Life Time in Ultra Pure Water and Alkaline Solution on Semiconductor Wet Cleaning Process (반도체 습식 세정 공정 중 상온의 초순수와 염기성 수용액 내에서 오존의 용해도 최적화)

  • Lee Sang-Ho;Lee Seung-Ho;Kim Kyu-Chae;Kwon Tae-Young;Park Jin-Goo;Bae So-Ik;Lee Gun-Ho;Kim In-Jung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.4 s.13
    • /
    • pp.19-26
    • /
    • 2005
  • The process optimization of ozone concentration and half life time was investigated in ultra pure water and alkaline solutions for the wet cleaning of silicon wafer surface at room temperature. In the ultra pure water,. the maximum concentration (35 ppm) of ozone was measured at oxygen flow rate of 3 liters/min and ozone generator power over 60%. The half life time of ozone increased at lower power of ozone generator. Additive gases such as $N_2$ and $CO_2$ were added to increase the concentration and half life time of ozone. Although the maximum ozone concentration was higher with the addition of $N_2$ gas, a longer half life time was observed with the addition of $CO_2$. When $NH_4OH$ of 0.05 or 0.10 vol% was added in DI water, the pH of the solution was around 10. The addition of ozone resulted in the half life time less than 1 min. In order to maintain high pH and ozone concentration, ozone was continuously supplied in 0.05 vol% ammonia solutions. 3 ppm of ozone was dissolved in ammonia solutions. The static contact angle of silicon wafer surface became hydrophilic. The particle removal was possible alkaline ozone solutions. The organic contamination can be removed by ozonated ultra pure water and then alkaline solution containing ozone can remove the particles on silicon surface at room temperature.

  • PDF

$1{times}8$ Array of GaAs/AlGaAs quantum well infrared photodetector with 7.8$\mu\textrm{m}$ peak response ($1{times}8$ 배열, 7.8 $\mu\textrm{m}$ 최대반응 GaAs/AlGaAs 양자우물 적외선 검출기)

  • 박은영;최정우;노삼규;최우석;박승한;조태희;홍성철;오병성;이승주
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.428-432
    • /
    • 1998
  • We fabricated 1$\times$8 array of GaAs/AlGaAs quantum well infrared photodetectors for the long wavelength infrared detection which is based on the bound-continuum intersubband transition, and characterized its electrical and optical properties. The device was grown on SI-GaAs(100) by the molecular beam epitaxy and consisted of 25 period of 40 ${\AA} $ GaAs well and 500 ${\AA} $ $Al_{0.28} Ga_{0.72}$ As barrier. To reduce the possibility of interface states only the center 20 ${\AA} $ of the well was doped with Si ($N_D=2{\times}10^{18} cm^{-3}$). We etched the sample to make square mesas of 200$\times$200 $\mu\textrm{m}^2$ and made an ohmic contact on each pixel with Au/Ge. Current-voltage characteristics and photoresponse spectrum of each detector reveal that the array was highly uniform and stable. The spectral responsivity and the detectivity $D^*$ were measured to be 180,260 V/W and $4.9{\times}10^9cm\sqrt{Hz}/W$ respectively at the peak wavelength of $\lambda$ =7.8 $\mu\textrm{m}$ and at T=10 K.

  • PDF

A Study on the Decisive Factors in Personal Health Maintenance Practice of Housewives Living in Younhi Area Apartments (연희지역 아파트주부의 건강관리실천의 결정요인분석에 관한 조사연구)

  • 김인숙
    • Journal of Korean Academy of Nursing
    • /
    • v.8 no.2
    • /
    • pp.89-102
    • /
    • 1978
  • Owing to the development of modern science, prolonging man's life, the sudden increase of population and betterment of the standard of living has increased health needs. In order to fulfill these health needs, more active plans for developing health should be made. Health education is one of the methods at hand that can improve the health behavior of the community and the individual through the contact of individuals with their groups. Proper understanding of the characteristics of the sampled group and participation of individuals within the community for the development of their health plan are needed for efficient health education. This study was attempted for the purpose of presenting some data helpful for pre-paring the fundamentals of a health education plan that can improve personal health maintenance practice of a community through efficient health education by investigating the relationship between the response of subjects to personal health maintenance practice and selected decisive factors in personal health maintenance practice. The subjects for this study were a systematic sample of 120 housewives selected from 600 housewives from B Zone Apt. Younhi-3-Dong in Seoul. Data was collected for 4 days from May 16th to May 19th, 1578 through personal interviews with questionnaires by well trained interviewers. Percentage, t-test and stepwise multiple regression analysis by use of EDPS were employed for statistical analysis. Results of this study can be summarized : 1. General characteristics of subjects Subjects over 20 and below 40 years of age formed 62.5% of the toed and the rest were subjects of 40 years and upward. 76.7% of the subjects have less than 4 children. 51.3% of the subjects had completed at least the senior high school course. 2. The response of subjects to personal health maintenance practice. Ratios of personal health maintenance practice to the maximum score for each category are as follows; 84.1% in the category of population and family planning, which was the highest ratio; 82.4% in the prevention of accidents; 68.0% in control of communicable disease; 67.8% in personal health care and habits of daily life, 64.3% in mental health and 52.5% in control of parasites, which was the lowest. 3. The response of subjects to selected decisive factors. in personal health maintenance practice. The arithmetic mean of the score for each decisive factor was as follows: the mutual relation between family members marked 18.33, which is under 73,3% of the maximum score; the degree of interest in health marked 34.48, 70.0% of the maximum score: the degree of utilization and demand for health care facilities marked 25.79 or 64.5% of the maximum score and health maintenance of the family marked 11.58, 43.6% of the maximum score. 4. The relationship between personal health maintenance practice and general characteristics of subjects. 1) There was a significant difference in the numbers of children. (t = 1.83, d.f. =117, p< 0.1) 2) There was a significant difference in the contact rates with mass-media, (t = 5.02, d.f. = 118, p< 0,05) 5. The multiple correlation between personal health maintenance practice and their selected decisive factors. 1) The factor“the degree of interest in health”could account for personal health maintenance practice in 43.6% of the sample. (R = 0.6602, R²= 0,4359, F = 91.1678, p< 0.001) 2) When the factor,“health maintenance of family”is added to this, it accounts for 51.2% of personal health maintenance practice. (R = 0.7158, R²= 0.5124, F = 61.4653, p< 0.001) 3) When the factor,“mutual relations between family members”is also included, it accounts for 53.7% of personal health maintenance practice. (R = 0.7324, R²= 0.5365, F = 44.7509, p< 0.001) 4) When the factor, “the degree of utilization and demand for health care facilities”is included, it accounts for 55.1% of personal health maintenance practice. (R = 0.7421, R²= 0.5507, F = 35.2430, p< 0.001).

  • PDF

Nanotube-based Dye-sensitized Solar Cells

  • Kim, Jae-Yup;Park, Sun-Ha;Choi, Jung-Woo;Shin, Jun-Young;Sung, Yung-Eun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.71-71
    • /
    • 2011
  • Dye-sensitized solar cells (DSCs) have drawn great academic attention due to their potential as low-cost renewable energy sources. DSCs contain a nanostructured TiO2 photoanode, which is a key-component for high conversion efficiency. Particularly, one-dimensional (1-D) nanostructured photoanodes can enhance the electron transport for the efficient collection to the conducting substrate in competition with the recombination processes. This is because photoelectron colletion is determined by trapping/detrapping events along the site of the electron traps (defects, surface states, grain boundaries, and self-trapping). Therefore, 1-D nanostructured photoanodes are advantageous for the fast electron transport due to their desirable features of greatly reduced intercrystalline contacts with specified directionality. In particular, anodic TiO2 nanotube (NT) electrodes recently have been intensively explored owing to their ideal structure for application in DSCs. Besides the enhanced electron transport properties resulted from the 1-D structure, highly ordered and vertically oriented nanostructure of anodic TiO2 NT can contribute additional merits, such as enhanced electrolyte diffusion, better interfacial contact with viscous electrolytes. First, to confirm the advantages of 1-D nanostructured material for the photoelectron collection, we compared the electron transport and charge recombination characteristics between nanoparticle (NP)- and nanorod (NR)-based photoanodes in DSCs by the stepped light-induced transient measurements of photocurrent and voltage (SLIM-PCV). We confirmed that the electron lifetime of the NR-based photoanode was much longer than that of the NP-based photoanode. In addition, highly ordered and vertically oriented TiO2 NT photoanodes were prepared by electrochemical anodization method. We compared the photovoltaic properties of DSCs utilizing TiO2 NT photoanodes prepared by one-step anodization and two-step anodization. And, to reduce the charge recombination rate, energy barrier layer (ZnO, Al2O3)-coated TiO2 NTs also applied in DSC. Furthermore, we applied the TiO2 NT photoanode in DSCs using a viscous electrolyte, i.e., cobalt bipyridyl redox electrolyte, and confirmed that the pore structure of NT array can enhance the performances of this viscous electrolyte.

  • PDF

A Study on Mechanical Interfacial Properties of Copper-plated Carbon Fibers/Epoxy Resin Composites (구리도금된 탄소섬유/에폭시 수지 복합재료의 기계적 계면 특성에 관한 연구)

  • Hong, Myung-Sun;Bae, Kyong-Min;Choi, Woong-Ki;Lee, Hae-Seong;Park, Soo-Jin;An, Kay-Hyeok;Kim, Byung-Joo
    • Applied Chemistry for Engineering
    • /
    • v.23 no.3
    • /
    • pp.313-319
    • /
    • 2012
  • In this work, the electroplating of copper was introduced on PAN-based carbon fibers for the enhancement of mechanical interfacial strength of carbon fibers-reinforced composites. The surface properties of carbon fibers were determined by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), and contact angle measurements. Its mechanical interfacial properties of the composites were studied by interlaminar shear strength (ILSS) and critical stress intensity factor ($K_{IC}$). From the results, it was found that the mechanical interfacial properties of Cu-plated carbon fibers-reinforced composites (Cu-CFRPs) enhanced with increasing the Cu plating time, Cu content and COOH group up to Cu-CFRP-30. However, the mechanical interfacial properties of the Cu-CFRPs decreased dramatically in the excessively Cu-plated CFRPs sample. In conclusion, the presence of Cu particles on carbon fiber surfaces can be a key factor to determine the mechanical interfacial properties of the Cu-CFRPs, but the excessive Cu content can lead the failure due to the interfacial separation between fibers and matrices in this system.

Affecting Factor Analysis for Respiration Rate Measurement Using Depth Camera (깊이 카메라를 이용한 호흡률 측정에 미치는 영향 요인 분석)

  • Oh, Kyeong-Taek;Shin, Cheung-Soo;Kim, Jeongmin;Jang, Won-Seuk;Yoo, Sun-Kook
    • Science of Emotion and Sensibility
    • /
    • v.19 no.3
    • /
    • pp.81-88
    • /
    • 2016
  • The purpose of this research was to analyze several factors that can affect the respiration rate measurement using the Creative Senz3D depth camera. Depth error and noise of the depth camera were considered as affecting factors. Ambient light was also considered. The result of this study showed that the depth error was increased with an increase of the distance between subject and depth camera. The result also showed depth asymmetry in the depth image. The depth values measured in right region of the depth image was higher than real distance and depth values measured in left of the depth image was lower than real distance. The difference error of the depth was influenced by the orientation of the depth camera. The noise created by the depth camera was increased as the distance between subject and depth camera was increased and it decreased as the window size was increased which was used to calculate noise level. Ambient light seems to have no influence on the depth value. In real environment, we measured respiration rate. Participants were asked to breathe 20 times. We could find that the respiration rate which was measured from depth camera shows excellent agreement with that of participants.

Developments of Advanced Connection Type for Improvements of Mixed Structures(I) : 3D Nonlinear Analysis of the Various Connection Types for Deriving Advanced Connection Type (혼합구조의 성능 향상을 위한 개선된 접합방식의 개발 (I) : 개선된 접합방식을 도출하기 위한 3차원 비선형 해석)

  • Yun, Ik Jung;Huh, Taik Nyung;Kim, Moon Kyum;Cho, Sung Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1A
    • /
    • pp.89-94
    • /
    • 2008
  • The problem of interaction between the structures interconnected at discrete points as like composite structures, has a attracted considerable attention for a prolonged period of time. Recently, mixed structures are applied for overcoming structural limits by developed countries. In this paper, advanced connection type of mixed structures are presented by numerical approach. Also it is performed on extensive literature review from theoretical method to numerical analysis. For analysing behaviors of mixed structures according to connection type, 2 different connections and 1 reinforced connection are compared by 3D nonlinear numerical analysis. Nonlinear analysis of mixed structures is carried out by utilizing contact elements of a general purpose structural analysis computer program(ABAQUS). By using 6 criteria, each connections are investigated. From this result, proper reinforcing and well designed connection type are proposed. And results also show that the deflections which are induced by discontinuity on mixed structures, has a linear distribution that should decrease as applying proposed connection type.