• Title/Summary/Keyword: 3 section control

Search Result 657, Processing Time 0.024 seconds

Aerodynamic Design of a Canard Controlled 2D Course Correction Fuze for Smart Munition (카나드 기반의 지능탄 조종 장치 공력설계)

  • Park, Ji-Hwan;Bae, Ju-Hyeon;Song, Min-Sup;Myong, Rho-Shin;Cho, Tae-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.3
    • /
    • pp.187-194
    • /
    • 2015
  • Course correction munition is a smart projectile which improves its accuracy by the control mechanism equipped in the fuze section with canard. In this paper, various aerodynamic configurations of the fuze section were analysed by utilizing a semi-empirical method and a CFD method. A final canard configuration showing the least drag was then determined. During the CFD simulation, it was found that the k-${\omega}$ SST turbulence model combined with O-type grid base is suitable for the prediction of the base drag. Finally, the aerodynamic characteristics of the smart munition and the change of drag due to the canard installation were analysed.

A Case Study on the High-quality DCM applied to the Foundation of Breakwater (방파제 기초에 적용된 고품질 DCM공법의 설계 및 시공 사례)

  • Kang, Yeoun-Ike;Shim, Min-Bo;Shim, Sung-Hyun;Kim, Ha-Young;Shim, Jae-Bum;Chun, Youn-Chul;Yoon, Jung-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.815-826
    • /
    • 2009
  • The paper presents a case study addressing the design and construction aspects for DCM(Deep Cement Mixing) method employed as the foundation of a caisson type breakwater with heavy weight(10,700 ton/EA) and a high design wave height($H_{1/3}$=8.7m). The DCM was designed for the project(Ulsan New Port North Breakwater Phase 1) by optimizing the pattern of DCM columns with a combination of short and long columns (i.e., block type(upper 3m)+wall type(lower)) and considering overlapped section between columns as a critical section against shear force where the coefficient of effective width of treated column($\alpha$) was estimated with caution. It was shown that the value can be 0.9 under the condition with the overlapped width of 30cm. In addition to that, a field trial test was performed after improving conventional DCM equipment (e.g., mixing blades, cement paste supplying pipes, multi auger motor, etc.) to establish a standardized DCM construction cycle (withdrawal rate of mixing blades) which can provide the prescribed strength. The result of the field strength test for cored DCM specimens shows that the averaged strength is larger than the target strength and the distribution of the strength(with a defect rate of 7%) also satisfies with the quality control normal distribution curve which allows defect rate of 15.9%.

  • PDF

Health monitoring of a new hysteretic damper subjected to earthquakes on a shaking table

  • Romo, L.;Benavent-Climent, A.;Morillas, L.;Escolano, D.;Gallego, A.
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.485-509
    • /
    • 2015
  • This paper presents the experimental results obtained by applying frequency-domain structural health monitoring techniques to assess the damage suffered on a special type of damper called Web Plastifying Damper (WPD). The WPD is a hysteretic type energy dissipator recently developed for the passive control of structures subjected to earthquakes. It consists of several I-section steel segments connected in parallel. The energy is dissipated through plastic deformations of the web of the I-sections, which constitute the dissipative parts of the damper. WPDs were subjected to successive histories of dynamically-imposed cyclic deformations of increasing magnitude with the shaking table of the University of Granada. To assess the damage to the web of the I-section steel segments after each history of loading, a new damage index called Area Index of Damage (AID) was obtained from simple vibration tests. The vibration signals were acquired by means of piezoelectric sensors attached on the I-sections, and non-parametric statistical methods were applied to calculate AID in terms of changes in frequency response functions. The damage index AID was correlated with another energy-based damage index -ID- which past research has proven to accurately characterize the level of mechanical damage. The ID is rooted in the decomposition of the load-displacement curve experienced by the damper into the so-called skeleton and Bauschinger parts. ID predicts the level of damage and the proximity to failure of the damper accurately, but it requires costly instrumentation. The experiments reported in this paper demonstrate a good correlation between AID and ID in a realistic seismic loading scenario consisting of dynamically applied arbitrary cyclic loads. Based on this correlation, it is possible to estimate ID indirectly from the AID, which calls for much simpler and less expensive instrumentation.

Intratumoral Administration of Rhenium-188-Labeled Pullulan Acetate Nanoparticles (PAN) in Mice Bearing CT-26 Cancer Cells for Suppression of Tumor Growth

  • Song, Ho-Chun;Na, Kun;Park, Keun-Hong;Shin, Chan-Ho;Bom, Hee-Seung;Kang, Dong-Min;Kim, Sung-Won;Lee, Eun-Seong;Lee, Don-Haeng
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.10
    • /
    • pp.1491-1498
    • /
    • 2006
  • The feasibility of pullulan acetate nanoparticles (PAN) with ionic strength (IS) sensitivity as a radioisotope carrier to inhibit tumor growth is demonstrated. PAN was radiolabeled with rhenium 188 (Re-188) without any chelating agents. The labeling efficiency of Re-188 into PAN (Re-188PAN) was $49.3{\pm}4.0%$ as determined by TLC. The tumor volumes of mice treated with 0.45 mCi of Re-188-PAN were measured and compared with that of free Re-188 after 5 days of intratumoral injection. For the histological evaluation of apoptotic nuclei of tumor cells, hematoxylin and eosin (H&E), and terminal deoxynucleotidyl transferase biotinylated deoxyuridine triphosphate nick end labeling (TUNEL) staining were performed. The mean tumor volume of the Re-188-PAN-treated group was decreased by 36% after 5 days, whereas that the free Re-188-treated group was decreased by only 15% (P<0.05). The mean number of TUNEL-positive cells in Re-188-PAN-treated tumors at $144.3{\pm}79.9$ cells/section was significantly greater than the control ($26.7{\pm}7.9$ cells/section, P=0.03). The numbers of leukocyte and lymphocyte were decreased in both free Re-188- and Re-188-PAN-treated mice. These results indicated that the intratumoral injection of Re-188-PAN effectively inhibits the tumor growth by prolonging Re-188 retention time in tumor site induced by the IS sensitivity.

A Study on Effectiveness of the Hospital-based Home Nursing Care of the Early Discharged Surgical Patients and its Cost Analysis (조기퇴원 수술환자의 병원중심 가정간호 효과 및 비용분석에 관한 연구)

  • 박경숙;정연강
    • Journal of Korean Academy of Nursing
    • /
    • v.24 no.4
    • /
    • pp.545-556
    • /
    • 1994
  • Medical insurance and health care delivery system enabled Korean people to get the necessary medical service, but it caused increased needs for medical service, and resulted in the occurence of some problems such as a lack of manpower and medical facilities. In order to solve these problems, many countries, which already had medical insurance system had developed home care system and it has been regarded effective both in reducing costs and in increasing the rates of turnover of bed. Recently, Korea has included home nursing care in its health care delivery system, and some models of the hospital based home nursing care had been tried and its effects had been evaluated. So, author tried to run a home nursing care for the Cesarean section mothers and evaluate Its effects both in the mother's health and costs. This study was designed as a Quasi-experimental study. Subjects were thirty mothers who got Cesarean section operation in hospital in Seoul. Experimental group consisted of 15 volunteers, and control group were selected by means of matching technique. Data were gathered from February 1st to March 26th by two assistants who were trained by author. Experimental group were discharged on the 4th day after their operation, and got nursing care and assessment about their home three times on the 5th, 6th, and 7th day. Control group stayed in the hospital until 7th day as usual and were checked on the same day as above mentioned To evaluate the state of physiological recovery, vital signs, H.O.F, presence of edema in the legs, bathing, appetite, sleep, presence of pain or discomfort in the breasts, amount of lochia, color of lochia, defecation urination. To compare incidence of complication in experimental group with that in control group, specific assessment was done such variables as smell of lochia, presence of inflammation of operation wound, dizziness, and presence of immobilization in the extremities. The activities of daily living were checked Satisfaction of nursing were checked To calculate costs, author asked subjects to specify expenditure including hospital charge, traffic enpenses, and food expenses. The results were as fellows. 1. On effectiveness of home nursing careThere were n significant differences between experimental and control group in incidence of abnormal symptoms and any complication. The number of taking a bath [POD #5 P=0.001, #6 P=0.0003, #7 P=0.001] and the degree of appetite [POD #5 P=0.03, #6 P=0.02, #7 P=0.013] were significantly higher in experimental group than in control group. Contrary to author's expectation, the degree of the activities of daily living in experimental group was not higher than that of control group. All of the experimental group said they were satisfied with the home nursing care. 2. Cost analysis 1) Hospital charge of experimental group was lower than that of control group. [P=0.009] By taking home nursing care, average period of hospitalization was shortened to 3.1 days, and family members could save 22.8 hours. Total amount of money saved by early discharge was 3,443,093 Won. It is estimated that total amount of money saved by early discharge in a year will be 40,398,956 Won. 2) Home nursing care charge of 15 mothers was 1,781,633 Won. It is estimated that total amount of money Saved by it in a year Will be 20,904,493 Won. It was lower altogether than hospital charge of the three days which is 5th, 6th, 7th day of operation. The average cost of single home visit was calculated 10,940 Won. It took 87 minutes per round and it costed 1,017.3 Won. The average hour of home care was 39.0 minutes. 3) It is expected that early discharge can bring forth the increase of hospital income. On the condition that the rate of running bed is 100%, the expected increase of hospital income will be 202,374, 026 Won in a year. Suggestions for further study and nursing practice are as follows : 1. For the welfare of patients and the increased rates of running bed, home nursing care system should be included in the hospital nursing care system. 2. Studies to test effect of home nursing care on the patients with other diseases are needed. 3. Establishment of law on the practice of home nursing care is strongly recommended.

  • PDF

Lamellar Body Counts in Fetal Rabbits' Experimental Diaphragmatic Hernia and Tracheal Ligation (기도결찰을 시행한 토끼 태자의 실험적 횡격막탈장에서 Lamellar body counts)

  • Chun, Yong-Soon;Jung, Soo-Jin;Lee, Jeong-Nyeo
    • Advances in pediatric surgery
    • /
    • v.17 no.2
    • /
    • pp.179-187
    • /
    • 2011
  • Experimental tracheal ligation (TL) has been shown to reverse the pulmonary hypoplasia associated with congenital diaphragmatic hernia (CDH) and to normalize gas exchange. The purpose of this study was to determine whether the TL would correct the surfactant deficiency present in the fetal rabbit model of CDH by using lamellar body count. Lamellar bodies are synthesized and secreted by the type II pneumocytes of fetal lung. The phospholipids present in these bodies constitute the major component of pulmonary surfactant. Twenty-one pregnant New Zealand rabbits underwent hysterotomy and fetal surgery on gestational day 24. Two fetuses of each pregnant rabbit were operated. In the fetus of one end of bicornuate uterus, left DH was created by excision of fetal diaphragm through open thoracotomy (DH Group). In the fetus of the other end of bicornuate uterus, left DH and TL were created (TL Group). The fetuses were delivered by Cesarean section on gestational day 31. Fourteen in control group, 12 in the DH group and 13 in TL group were born alive. En bloc excision of lungs, bronchi and trachea was done in all newborn rabbits. A five Fr catheter was inserted through trachea and repeated irrigations with 10 cc normal saline were done. The irrigated fluid was centrifuged at $280{\times}g$ for 5 minutes and the lamellar bodies were counted with the upper level fluid in platelet channel of electronic cell counter. The average lamellar body counts were $37.1{\pm}14.2{\times}10^3/{\mu}L$ in control group, $11.5{\pm}4.4 {\times}10^3/{\mu}L$ in DH group, and $6.5{\pm}0.9{\times}10^3/{\mu}L$ in TL group. Lamellar body count in DH group was lower than in control group and did not increase after TL. This study shows TL has no therapeutic effect on decreased surfactant level of CDH and the pregnant rabbit is appropriate for the animal model of CDH.

  • PDF

Changes of Air Permeability and Moisture Absorption Capability of the Wood by Organosolv Pretreatment

  • Kang, Chun-Won;Jang, Eun-Suk;Jang, Sangsik;Kang, Ho-Yang;Li, Chengyuan;Choi, In-Gyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.6
    • /
    • pp.637-644
    • /
    • 2018
  • The air permeability of yellow poplar log cross section before and after organosolv pretreatment was investigated, and the moisture absorption of control and organosolv pretreated rectangular parallelepiped specimens was investigated in this study. It was revealed that the diameters of through pores were enlarged and the number of bigger pore was increased by the organosolv pretreatment. The air permeabilities of the cross sections of yellow poplar log were changed from 1.61 darcy to 23.30 darcy, but their weights were reduced by 5 percent. The equilibrium moisture content of control wood specimen at the exposed relative humidity were 5.9 % at 32 %, 9.7 % at 58 %, 14.8 % at 80.5 %, 19.7 % at 90 %, 25.7 % at 95 % and 29.9 % at 100%. The equilibrium moisture content of the specimens pretreated with the parameter of sulfuric acid catalyst of 0.5 % (w/w) were 19.5 % at 32 %, 29.3 % at 58 %, 39.6 % at 80.5 %, 59 % at 90 %, 111.3 % at 95 % and 111.3 % at 100 %, while those pretreated with the parameter of sulfuric acid catalyst of 1.0 % (w/w) were 17.4 % at 32 %, 23.9 % at 58 %, 27.7 % at 80.5 %, 40.6 % at 90 %, 68.8 % at 95 % and 110.0 % at 100 %. The moisture absorption of organosolv pretreated rectangular parallelepiped specimens was higher than that of control specimen.

Development of VSL Control Algorithms for Various Traffic Conditions in Tunnels (교통상황별 터널부 VSL 표출제어 알고리즘 개발)

  • Lee, Soo-Yang;Lee, Sang-Soo;Lee, Choul-ki
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.3
    • /
    • pp.84-94
    • /
    • 2019
  • This paper developed the VSL control algorithms for various traffic conditions in tunnels. Various algorithms determining control speed, buffer speed, and display time were suggested in order to apply three gantry locations. The algorithms were evaluated by constructing simulation environments using python and VISSIM Com-Interface. Results show that speed difference between congested flow and normal flow was 50 km/h without algorithm application, but the difference was reduced to 20 km/h with algorithm application. In addition, the length of congested region in the exit section of the tunnel was also reduced from 800m to 300m with algorithm application. It is expected that the traffic accidents in tunnels may be reduced since the average and standard deviation of the speed are greatly reduced after applying the algorithms suggested.

Development and validation of reactor nuclear design code CORCA-3D

  • An, Ping;Ma, Yongqiang;Xiao, Peng;Guo, Fengchen;Lu, Wei;Chai, Xiaoming
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1721-1728
    • /
    • 2019
  • The advanced node core code CORCA-3D is one of the independent developed codes of NPIC for the nuclear reactor core design. CORCA-3D code can calculate the few-group cross section, solve the 3D diffusion equations, consider the thermal-hydraulic feedback, reconstruct the pin-by-pin power. It has lots of functions such as changing core status calculation, critical searching, control rod value calculation, coefficient calculation and so on. The main theory and functions of CORCA-3D code are introduced and validated with a lot of reactor measured data and the SCIENCE system. Now, CORCA-3D code has been applied in ACP type reactor nuclear cores design.

Influence of nuclear data library on neutronics benchmark of China experimental fast reactor start-up tests

  • Guo, Hui;Jin, Xin;Huo, Xingkai;Gu, Hanyang;Wu, Haicheng
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3888-3896
    • /
    • 2022
  • Nuclear data is the basis of reactor physics analysis. This paper aim at studying the influence of major evaluated nuclear data libraries, CENDL-3.2, ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0u, on the neutronics modelling of CEFR start-up tests. Results show these four libraries have a good performance and consistency in the modelling CEFR start-up tests. The JEFF-3.3 results exhibit only an 8 pcm keff difference with the measurement. The difference in criticality is decomposed by nuclide, which shows the large overestimation of CENDL-3.2 is mainly from the cross-section of 52Cr. Except for few cases, the calculation results are within 1σ of measurement uncertainty in control rod worth, sodium void reactivity, temperature reactivity, and subassembly swap reactivity. In the evaluation of axial and radial reaction distribution, there are about 65% of relative errors that are less than 5% and 82% of relative errors that are less than 10%.