• Title/Summary/Keyword: 3 Lens

Search Result 1,463, Processing Time 0.029 seconds

Effects of Some Monoterpenes on Bovine Lens Aldose Reductase Activity

  • Moon, Chang-Kiu;Choi, Soo-Young;Ha, Bae-Jin
    • Archives of Pharmacal Research
    • /
    • v.11 no.4
    • /
    • pp.312-314
    • /
    • 1988
  • Thirteen monoterpenes were examined for their effects on the bovine lens aldose reductase activity. the monoterpenes tested in this study showed mild inhibitory effects except 3-carene which did not show any significant effect. At the concentration of $10^{-3}$ M(+) Pulegon showed 42% inhibition on lens aldose reductase activity, which is the most otent effect among the tested substance.

  • PDF

The Current State of Lens Care in Contact Lens Wearer (콘택트렌즈 착용에 따른 사용자 실태조사)

  • Ryu, Geun Chang;Kim, In Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.15-20
    • /
    • 2002
  • The Hydroxyethyl methacrylate(HEMA) was developped in 1960's and later the use of contact lenses increased. At present more and more people use RGP contact lenses. Due to the wide range of optical corrections available and due to their high oxygen transmission Japanese and Korean people like them. Nevertheless one of nine CL users(beginners) stopped wearing the CL within the first year. We conducted a survey to evaluate the level of patient compliance in lens care and maintenance and to assess practitioner knowledge of contact lens information. Generally 6% of contact lens wearers drop out per year. The aim of this research was to find out what opticians can do to reduce the drop-out rate by getting information on handling, on general data of the patient and on optical prescription. Lens wearer were asked to complete a 10 question survey that focused on lens care-wear modality, lens replacement, storage, symptoms and case disinfection. There were total 180 participants in the study. Most of contact lens wearers have an inadequate understanding of contact lens care system. Therefore, it is important that contact lens specialists place more emphasis on practitioner education about general contact lens fields and reinforce patient education during the dispensing visit.

  • PDF

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

The State and Problem of the Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 실태와 문제점)

  • Kim, Douk-Hoon;Hwang, Sun-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.249-258
    • /
    • 1998
  • This study was researched the state and problem of the soft contact Lens wear by the history and inverted microscopy. The results was as follows; 1. The first use of contact lens wear was the 15 years and the last use was the 26 years. The first age of most contact lens wear was the 19 years. 2. In the almost contact lens wearers, the first visual test was the optical shop. 3. At present, almost soft contact lens purchase the optical shop 4. At present, most contact lens wearer like a soft type. 5. At present, most soft contact lens were a domestic production, and some subjects were foreign country production, but some subjects were unknown. 6. After contact lens wear, most subjects don't known the corrected visual acuity, especially, almost people don't known the binocular visual acuity. 7. At present, on soft contact lens color, the teens like the non-color contact lens, twenties like the color contact lens, but thirties was not known. 8. On the advantage of soft contact lens knowledge, most teens and twenties were only one, thirties was unknown. 9. On the disadvantage of soft contact lens knowledge, most teens and thirties were only one, twenties were two. 10. On the side effect of soft contact lens wearer, teens was one, and twenties and thirties don't known. 11. On the main symptoms of soft contact lens wearer, total kinds were seven, On these kinds, most subjects were not symptoms, the next order was unknown on the symptom. But, On the symptoms, the main symptoms was the pain and dry eye. 12. At present, the research on the surface morphology of soft contact lens by inverted microscope, the lens repture, lens folding, foreign body immersion and etc were present. Above the study, most contact lens was soft lens, and the purchase was the optical shop, on the other hand, the knowledge of soft contact lens and visual acuity was few. As a results, On the practical problems of soft contact lens wear, the optician have to the soft contact lens treatment and aftercare by law and educational supporting.

  • PDF

Comparison of In Vitro Lipid Deposition and Change of Optical Characteristics on Daily Disposable Lenses (1-day) and 3-days Lenses Over 3 days (3-days lenses와 daily disposable lenses(1-day)의 착용 시간 별 지방 침착량 및 광학적 특성 변화의 비교)

  • Song, Sun Jung;Lee, Su Yeon;Kim, Ki Hong;Chu, Byoung Sun
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.2
    • /
    • pp.67-73
    • /
    • 2020
  • The study aimed to investigate in vitro lipid deposition of oleic acid, oleic acid methyl ester and cholesterol on a daily disposable (1-day lenses) and 3-days lenses over 3 days and changes of optical characteristics is also investigated. Artificial tear solutions were prepared to simulate actual tear compositions. Two types of contact lenses (1-day lenses (Senofilcon A) and 3-days lenses (silicone tripolymer)) were soaked in the artificial tear solutions within an incubator at 37 ℃ with 150 rpm for 8, 16, 24 hours. Lipid deposition (oleic acid, oleic acid methyl ester and cholesterol) were measured using high performance liquid chromatography (HPLC) instrument. In addition, measurements of oxygen transmissibility, light transmittance and observation of lens surface were conducted. The amount of lipid deposition on the 1-day lenses were 127.55 ㎍/lens for Day 1, 302.96 ㎍/lens, for Day 2, and 353.30 ㎍/lens for Day 3. The 3-days lenses were 46.22 ㎍/lens for Day 1, 66.07 ㎍/lens for Day 2, and 67.45 ㎍/lens for Day 3. Oxygen transmissibility were 81×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 48×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 1-day lenses, it were 13.23×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 9.6×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 3-days lenses. Transmittance of each lenses were 97.21% (Baseline) and 94.25% (Day 3) for the 1-day lenses, 97.65% (Baseline) and 95.15% (Day 3) for the 3-days lenses. Observation of surface deposition indicated greatest deposition for the 3-days lenses type on Day 3. Lipid deposition for both lens types increased by day and was greater for the 1-day lenses type. Surface deposition appeared to differ as it was greatest for the 3 days lens type, which may suggest other deposits such as protein may be present.

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

Optics of the light-weight and foldable telescope based on the Fresnel lens

  • Yu, Hyungjoon;Park, Yong-Sun;Chung, Haeun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.57.3-58
    • /
    • 2016
  • We analyze an optical system of a telescope based on Fresnel type objective lens as suggested by Hyde (1999). The Fresnel objective lens can be thin, light-weight and foldable, and therefore it is possible to develop a space telescope with an aperture larger than that of traditional telescopes. Moreover a lens, whatever it is either Fresnel type or conventional, allows much larger fabrication tolerances. We design a medium-sized telescope adopting Fresnel lens as an objective lens for use in space and possibly on the ground. The well-known chromatic aberration of the Fresnel primary lens is corrected by a field lens and another Fresnel lens using Schupmann method. An additional lens is used for forming images. We analyze the chromatic and off-axis aberrations of the proposed system analytically and suggest methods for the minimization of off-axis aberrations and for the operation in wider spectral range. We also conduct ray tracing and optimize the whole optical system with commercial software. Finally we present the design parameters of a telescope with an aperture of 0.5 to 1 meters, enabling diffraction limited operation for a moderate field of view about 10 arc-minutes.

  • PDF

A Bump Mapping Method Using Camera Lens (카메라 렌즈를 이용한 범프 맵핑)

  • Koh, Wook
    • Journal of the Korea Computer Graphics Society
    • /
    • v.3 no.1
    • /
    • pp.9-15
    • /
    • 1997
  • Most rendering research has concentrated on two sub-problems: modeling the reflection of light sources, and calculating the direct and indirect illumination from light sources and other surfaces. As Kolb wrote in [1], the camera and lens model is an important key component of a rendering system. In this paper we describe a bump-mapping method using camera lens. It allows another level of control in rendering. We developed an efficient framework to develop customized bump mapping lens and combine with other sequence of lens elements to create various effects as shown in Figure 2,3,4,5.

  • PDF

Changes of Refractive Correction Value with Different Age Group: A Case for Myopia Control Lens, Single Vision Lens and Reverse Geometry Contact Lens (Myopia Control Lens, Single Vision Lens, Reverse Geometry Contact Lens의 연령에 따른 굴절교정상태 변화에 대한 추적 연구)

  • Yoon, Min-Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.75-84
    • /
    • 2013
  • Purpose: Changes of refractive correction value in different age group were investigated. Regarding the inhibitive effects against myopia progression after wearing reverse geometry contact lenses and myopia control lenses (MC lenses), the effects after wearing single vision lenses were compared. Methods: We organized children between the ages of six and fifteen into three groups by age, and distributed fifty-seven reverse geometry contact lenses, fifty-six MC lenses and seventy-eight single vision lenses among them to be worn. Group 1 consisted of children aged ten and under, Group 2 consisted of children between the ages of eleven and fifteen, and Group 3 represents all of the study participants. The aim of this study was to learn the inhibitive effects against myopia progression attained by changes of refractive correction value and to verify their statistical significance at twelve months and under, thirteen to twenty-four months and twenty-five to thirty-six months. Results: Changes of refractive correction value by each length of use in Group 3 were as follows. For the age group of under twelve months, participants using the reverse geometric contact lens showed no change, while those using the MC or single vision lens had significant changes (P<0.05) of $-0.36{\pm}0.10$ D and $-0.67{\pm}0.52$ D, respectively. Users of all three lens types displayed significant change (P<0.05), in the age group of between thirteen and twenty-four months, of $0.18{\pm}0.49$ D, $0.60{\pm}0.42$ D and $1.37{\pm}0.72$ D for users of the reverse geometry contact lens, the MC lens and the single vision lens, respectively. There were significant changes (P<0.05) of $0.29{\pm}0.61$ D, $0.93{\pm}0.57$ D and $1.72{\pm}0.78$ in the same respective order as the above in the age group of twenty-five to thirty-six months. Refractive correction value showed changes with different age group. Group 1 displayed significant changes (P<0.05) of $0.29{\pm}0.73$ D, $1.07{\pm}0.59$ D and $1.75{\pm}0.74$ D for users of the reverse geometry contact lens, MC lens and single vision lens, respectively, up to thirty-six months of lens wearing; Group 2, also up to thirty-six months, displayed significant changes (P<0.05) of $0.28{\pm}0.42$ D, $0.75{\pm}0.49$ D and $1.70{\pm}0.84$ D in the same respective order, and changes in refractive correction for the age group under ten years was significantly greater (P<0.05) for the age group of eleven and older. Conclusions: The results found in this study demonstrate that there were no changes of refractive correction value for the case of wearing reversing geometry contact lens up to twelve month or less. MC lens showed less changes in variations of visual acuity for all users which might be resulted in inhibiting progression of myoptia. When both reverse geometry contact lens and the MC lens are wearing for the period from 13 to 36 month, both lens showed less changes in variation of visual acuity for all users. The results suggested that the less changes in variation of visual acuity of both lens had an effect on inhibiting progression of myopia.