Now a days in our society, occupation boundaries have become blurred, and come into the limelight in the prior occupation or miss about new workplace. Medical area is no exception also, So we face urgent problem about protecting and spreading RT work-sphere simultaneously. This research allow to identify on RT role area of digital environment that is obscure profession-realm specially, and open up a new field hereafter. We examined present RT role area of digital environment in the more than thirty medical facility(general or university hospital) through questionnaire/visit survey from PACS administrator. Survey sentence comprises total 29 sentence over all main quadrisection-(eX. hospital formation & treatment state and PACS team composition & organization and PACS team workplace and PACS team daily workload), We performed comparative analysis in general contents perspectively. further more, divided main 5 section based on upper analysis and then manufactured output in consideration of each medical facility's operation state. There are comparative problem of hospital policy, So we maintained information security of each facility exhaustively. First, we separated a survey output into main 5 section as follows-(eX. PACS server & maintenance manage, Client/interlock manage, PACS data conversion, 3D reconstruction, PACS data im/export)-that received by 35 medical facility. And then manufactured output with comparative analysis about RT role area each section, general IT managing team about medical environment was out of existence that fill up with RT manpower in the surveyed medical facility consequently. What is worse, hospitals that entirely fill up with another worker were 3 place amazingly. Our specific statistic results show, the respondents was 63% that agree with reorganization of formation base on independence team, and supplement of the personnel average -continuous with upper agreement simply-was about 2.64. Further more, if reorganization break out with only RT manpower, quota TO will increase by geometric progression. Protecting and spreading role workplace is much accounted of the our inevitable project surely and more than 95% PACS administrator's have confidence in this proposition unconditionally. Henceforth, look forward to meeting the RT vision of many-sided multiplayer, based on acquire a specialized IT knowledge actively and open up a new work-field with frontier spirit.
개에서 컴퓨터단층촬영술을 이용하여, 촬영 자세에 따른 정상 폐의 용적과 밀도를 정량적으로 평가하였다. 각각 6 마리의 페키니즈견과 말티즈견에서 컴퓨터단층촬영을 실시하면서 자세를 앙와위, 좌측과 우측 횡와위, 그리고 흉와위로 변경하였다. 컴퓨터단층촬영을 실시하는 동안 일정한 정도의 양압환기를 실시하였다. 폐용적과 밀도는 CT 영상의 삼차원 재구성 방식을 통해 측정하였고, 전체 폐용적 및 밀도, 좌측과 우측 폐의 용적과 밀도를 각각 측정하였다. 삼차원 재구성 결과 폐의 모양은 두 품종견에서 매우 다르게 나타났다. 폐용적과 밀도는 촬영 자세를 변경하는 동안 두 품종견에서 모두 유의적인 변화를 보이지 않았다. 오른쪽 폐용적이 왼쪽 폐에 비해 유의적으로 약 $66.91{\pm}25.1$ ml 만큼 컸다. 페키니즈 견과 말티즈 견의 체중 차이가 유의적이었으며, 체중과 흉와위로 촬영한 폐용적 간에 선형관계가 관찰되었다. 좌우측 횡와위 촬영에서 중력의 영향을 받는 쪽의 폐는 반대쪽 폐에 비해 밀도는 높고 용적은 감소되었다. 컴퓨터단층촬영으로 측정한 전체 폐용적은 폐밀도와 관련이 있었으며, 폐밀도가 정상 폐용적을 유추하는데 유용하게 사용될 것으로 생각된다.
본 연구는 임상간호사의 심폐소생술에 대한 지식과 기술을 향상시키기 위해 웹 기반의 교육 프로그램을 개발하고 평가하는 데 목적이 있다. 2002년 2월 1일부터 4월 30의 기간동안 류세앙(1999)이 수정한 프로그램 개발과정에 의해 분석, 설계, 자료수집 및 개발, 프로그래밍 및 구현, 평가를 거쳐 웹 기반의 심폐소생술 간호교육 프로그램을 개발하였다. 본 연구의 결과는 다음과 같다. 1) 본 프로그램은 심폐소생술의 의의와 중요성, 기본심폐소생술, 장기심폐소생술, 소생술 후 간호를 학습내용으로 하여 텍스트 자료, 사진, 그림, 동영상 자료 등을 나모 웹 에디터, 스캐너, Adobe photoshop 등을 이용하여 인터넷 파일 제작과 이미지 수정단계를 거쳐 FTP(File Transfer Protocol)을 이용하여 웹에 올리고 시범운영을 통해 최종 수정하여 완성된 프로그램이 개발되었다. 2) 평가단계에서는 D시내에 소재한 K대학병원에 근무하는 간호사 36명을 임의표출하여 프로그램을 사용한 후의 반응을 조사하였다. 이에 대한 결과는 다음과 같다. 학습교재 관련특성의 평점은 $4.2{\pm}.67$, 학습 시스템 관련특성의 평점은 $4.0{\pm}.79$점, 학습자 만족도 관련특성에 대한 반응에서 학습자의 만족도는 $4.2{\pm}.58$점, 다른 교육 프로그램의 개발필요성은 $4.3{\pm}.62$점을 얻어 총평점은 $4.1{\pm}.45$점이었다. 특히, 멀티미디어 자료의 적절성은 $4.3{\pm}.68$점, 다른 교육 프로그램의 개발필요성은 $4.3{\pm}.62$점이었고, 화면구성과 배색의 적절성에서 $3.8{\pm}.81$점, 화면크기와 글자크기의 적절성에서 $3.7{\pm}.81$점이었다. 이상의 결과를 볼 때 프로그램 평가에 대한 분석작업을 거쳐 교육 프로그램의 지속적인 업그레이드 작업이 이루어진다면 본 웹 기반의 간호교육 프로그램이 간호사들의 계속교육과 평생교육에 활용될 수 있는 효과적인 교육 프로그램이 될 수 있으리라 사료된다.
PET/CT 검사 시 검사 부위에 따라 적절한 액세서리의 사용이 권고되고 있다. 그 중 brain 검사에서 사용되는 액세서리인 brain holder를 사용하지 않는 경우 CT의 small FOV에 의하여 whole pallet이 AC-CT에 cover되지 않으며, 이에 따른 truncated region에 따라 count loss가 발생된다. 본 논문에서는 brain holder를 사용하지 않았을 경우 발생하는 truncated region에 의한 image quality의 변화를 평가하고자 한다. Siemens사의 biograph truepoint40 장비와 $^{68}Ge$-uniform phantom을 사용하여 $^{68}Ge$ phantom을 pallet위에서 스캔하고 brain holder위에 위치하고 스캔 하였다. brain protocol을 적용하여 holder를 사용하지 않은 경우 pallet이 AC-CT의 FOV에 포함되지 않는 것을 알 수 있었다. 획득된 영상을 FBP, OSEM, TrueX recon method를 이용하여 iteration 4, subsets 21, gaussian 2 mm와 5 mm parameter를 적용하여 재구성 후 Window level : -4200, window width : 1000으로 설정하여 영상의 uniformity를 평가하였으며, vertical profile을 생성하여 count uniformity를 평가하였고, 마지막으로 5장과 20장의 slice를 summation하여 integral uniformity를 평가하였다. AC-CT영상을 통하여 holder를 사용하지 않는 경우 FOV내에 pallet이 모두 포함되지 않는 것을 알 수 있으며, 이에 따른 truncation에 의한 부정확한 attenuation factor가 나타났다 PET corrected sinogram 영상에서 holder를 사용하지 않은 경우 truncated region에 의한 defect 부위를 확인할 수 있으며, holder를 사용한 경우 uniform한 영상을 확인할 수 있었다. Window level : 4200, window width : 1000으로 설정 시 FBP, OSEM, TrueX recon 방법 모두에서 holder를 사용한 경우 uniform한 영상이 획득되었지만, holder를 사용하지 않은 경우 하단에 defect가 관찰되었다. Holder를 사용한 경우와 사용하지 않은 경우의 영상을 각 5장, 20장씩 summation하여 NEMA method에 따라 integral uniformity를 구하였으며, 5장 slice의 summation에서 holder를 사용하지 않은 경우 11.7% holder를 사용한 경우 7.2%로 나타났다. 20장 slice의 summation에서 holder를 사용하지 않은 경우 11.1% holder를 사용한 경우 76.7%로 나타났다. brain 검사 시 holder를 사용하지 않는 경우 truncated region에 따른 phantom 하단부의 count defect가 확인되었으며, 이는 환자 검사 시 occipital lobe의 count loss를 발생하게 되며 research 검사 시 검사 결과의 오차를 발생하게 됨으로 brain PET/CT 검사 시 정확한 검사결과를 위하여 검사 액세서리가 반드시 적용되어야 할 것이다.
1-day protocol method는 DIAMOX 영상에서 basal 영상을 감산시키는 방법으로 혈관 예비능을 평가하는데 있어서 매우 유용한 검사지만, 검사시간이 길기 때문에 움직임에 의한 불가피한 재검사율이 높다. 기하학적으로 차이가 있는 fan-beam 콜리메이터와 parallel 콜리메이터 중 임상적으로 1-day protocol method에 가장 효율적인 콜리메이터가 무엇인지 알아보았다. 삼중 헤드 감마카메라인 triad XLT 9 (TRIONIX)와 세 가지 콜리메이터(low energy high resolution-parallel beam: LEHR-par, ultra resolution-fan beam: LEUR-fan, super fine-fan beam: LESR-fan)를 사용하였다. PET/SPECT performance phantom, Hoffman 3D phantom, volunteer 실험을 실시하여 세 가지 콜리메이터의 감도, 대조도, 해상력, 영상의 질을 비교 측정하였다. Pixel size를 fan-beam 콜리메이터와 동일하게 하기 위하여 parallel 콜리메이터 실험 시 zoom factor를 2.0으로 변경하였다. Scan time은 50 kcounts/frame을 만족하게 하였으며 filtered back projection (FBP)의 재구성 방법을 사용하였고 각 콜리메이터 별 최적의 영상을 위하여 cut off 값을 변화하면서 비교 측정하였다. 총 획득 계수가 동일한 조건에서 해상력과 percent background variability는 LESR과 LEUR이 LEHR보다 우수한 결과를 나타내었고, 영상의 육안평가에서 선호도는 LESR, LEUR, LEHR 순이었다. 영상 획득 시간은 LESR이 낮은 감도로 인하여 LEUR과 LEHR보다 약 2배 더 길게 소요됐다. Volunteer 실험의 결과 LESR을 사용할 때보다 LEUR 또는 LEHR을 사용 할 때 약 10-14분 정도 시간이 감소했다. 1-day protocol method는 단 한 번의 움직임에도 재검사가 불가피하기 때문에 적절한 분해능뿐만 아니라 높은 감도의 유지를 위해 적절한 검사 방법의 확립이 중요하다 할 수 있다. 본 연구에서 동일한 계수를 획득할 경우 LEUR은 LESR보다 2배의 시간을 감소시킬 수 있었고 영상의 육안평가나 해상력도 LESR과 임상적으로 큰 차이를 보이지 않았으므로 Brain SPECT의 1-day protocol method에 가장 적합할 것으로 사료된다.
Among objectives of periodontal therapy. the principal one is the morphological and functional reconstruction of lost periodontal supporting tissues. This includes de novo formation of connective tissue attachment and the regrowth of alveolar bone. The use of enamel matrix derivative(EMD) may be a suitable means of regeneration new periodontal attachment in the infrabony defects. Implant used to replace lost tooth but, implantitis occurred after installation. The purpose of this study was to investigate the effects of EMD on differentiation and growth of osteoblast in titanium disc. Twentyfive millimeter diameter and 1mm thick Ti disc which was coated 25, 50, 100, 200${\mu}g$/ml of EMD(Emdogain(R)) used as experimental group, 25, 50, 100, 200ng/d of rhBMP-2 as positive control group, and no coat as negative control group. A human osteosarcoma cell line Saos-2 was cultured in Ti disc and cell proliferation and Alkaline phosphatase (ALP) activity were measured at 1 and 6 days. PCR was performed at 2 and 8 hours. Semi-quantitative RT-PCR for mRNA expressions of various osteoblastic differentiation markers -type I collagen, ALP, osteopontin, and bone sialoprotein - were performed at appropriate concentrations based upon the results of MTT and ALP assay. Cultured cell-disc complexes were prepared for scanning electron microscopy (SEM) at 2 hour. Data were analyzed using Mann-Whitney and repeated- measures 1-way analysis of variance(SPSS software version 10,SPSS. Chicago. IL). After culture, there was more osteoblast in EMD100${\mu}g$/ml than in EMD50, 200${\mu}g$/ml on day 6. There was significant difference in experimental and positive control group compared control group, as times go by(1 and 6 days). Alkaline phosphatase activity was different significantly in EMD100, 200${\mu}g$/ml and BMP100, 200${\mu}g$/ml on day 6. The results of reverse transcriptase-polymerase chain reaction (RT-PCR) showed that expression of mRNA for ALPase, collagen type I, osteopontin. hone sialoprotein and BMP-2 was detected at 2 hour and 8 hour in EMI 200${\mu}g$/ml subgroup and BMP100ng/ml subgroup. The results of this study suggest that application of enamel matrix derivative on osteoblast attached to titanium surface facilitate the expression of bone specific protein and the differentiation and growth of osteoblast.
도미분지에 위치한 도미-1공과 소라-1공을 대상으로 와편모조류 미화석, 유기물상 분석 및 탄성파자료 해석을 통한 지층대비의 방법으로 연구지역의 층서와 고환경을 해석하고, 그 결과를 일본 북서 큐슈지역의 기존 연구결과와 비교하였다. 생물상변화를 토대로 상부에서부터 Ecozone A, Ecozone B(Barren zone), Ecozone C, Ecozone D(Barren zone)로 각각 4개의 생태층서대로 나누었다. 표준화석에 의한 지질시대는 2개 시추공 모두 하부로부터 에오세 - 올리고세, 마이오세, 플라이오세 - 플라이스토세 시기로 나타났다. 유기물상에 의한 고환경은 상부에서 시작하여 다음과 같이 5개로 나누었다; Association I(Inner neritic), Association II(Freshwater), Association III(Inner neritic), Association IV(Freshwater), Association V(Swamp). 두 개의 시추공 자료를 토대로 일본 측 생층서 자료와 비교 한 결과, Heteraluacacysta campanula, Tubiosphaera galatea 등의 에오세 - 올리고세 표준화석이 양측 연구 모두 동일하게 나타나고, 두 지역의 군집조성이 유사함을 확인하였다. 이는 도미분지와 일본의 북서 큐슈 지역의 고제3기층 발달사에 서로 연관성이 있음을 시사한다.
목적 : 자기공명영상화는 보통 긴 스캔 시간으로 인해 환자의 움직임이 큰 문제가 된다. 이러한 환자의 움직임을 보정하기 위한 한가지 방법인 영상의 엔트로피(entropy)를 이용한 후처리 방법은 다른 추가 데이터 획득 없이 효과적으로 움직임 인공물을 줄일 수 있음을 보였다. 하지만 이 방법의 가장 큰 문제는 처리 시간이 매우 길다는데 있다. 본 연구에서는 움직임 보정 처리시간을 줄이는 방법을 제안한다. 대상 및 방법 : 전체적인 보정 시간을 줄이기 위한 첫 번째 방법은, 퓨리에 변환의 분리성을 이용하여 전체적인 퓨리에 변환시간을 줄일 수 있다. 영상의 엔트로피 기준을 대신해 영상의 전체 화소의 합(pixel sum)을 움직임 보정의 기준으로 이용하여 영상 기준을 계산하는 시간을 절반 이하로 줄일 수 있다. 마지막으로 부분 퓨리에 재구성 방법을 조합하여 움직임의 영향을 보정하는 k-공간의 데이터 량을 줄임으로써 전체적인 처리 시간을 큰 폭으로 줄일 수 있다. 결과 : 제안한 방법을 사용하여 보정한 영상의 품질은 엔트로피를 이용한 보정 방법과 거의 흡사했으며, 대신 전체적인 처리 시간을 2차원 영상에서 15%로, 3차원 영상에서 30%로 줄일 수 있었다. 결론 : 제안한 방법을 병렬 영상화 기법 등과 결합하여 영상 보정 시간을 더욱 줄일 수 있을 것으로 기대한다. 제안하는 방법은 다른 보정 기법을 사용할 수 없을 때, 영상에서 움직임의 영향을 줄이는 방법으로 유용할 것으로 기대한다.
교근의 근방추에서 유래하여 단일 연접성 고유수용성 악반사에 관여하는 구심성 신경섬유를 단일 축삭내 HRP 주입기법으로 염색해서 삼차신경 운동핵에서의 type I a 및 type II 신경 섬유 종말부의 미세 구조 및 연접양상을 분석한 결과는 다음과 같았다. ${\cdot}$ 대부분의 표식 종말지는 dome, 길쭉한 형태 혹은 둥근 모양을 나타내었으며, scalloped 형태 혹은 glomerulus 형태는 관찰되지 않았다. ${\cdot}$ 표식 종말지는 다수의 균일한 형태 및 크기(49-52nm) 의 투명한 구형의 소포와 때때로 소수의 치밀소포(직경:87-114nm)를 함유하고 있었다. ${\cdot}$ 표식 종말지의 크기는 type I a가 장경($1.91{\pm}0.63{\mu}m$), 단경($0.94{\pm}0.28{\mu}m$) 및 평균 직경($1.42{\pm}0.40{\mu}m$)에서 type II보다 작았다(p<0.05). ${\cdot}$ 표식 종말지는 신경원체 혹은 가지돌기와 비대칭 연접을 이루었으며, 다형소포와 같은 연접소포들을 함유하는 종말부와의 연접은 관찰되지 않았다. ${\cdot}$ 대부분의 type I a (94.9%) 및 type II(85.9%) 종말지는 단지 1개의 neuronal propile과 연접을 이루었으며, 4개 이상의 neuronal propile들과 연접을 이루는 경우는 관찰되지 않았다. ${\cdot}$ type I a 종말지에 있어서 대부분(87.2%)은 신경원체 및 근심부 가지돌기와 연접을 이루는데 반해 type II 종말지는 다수가(64.8%) 원심부 가지돌기와 연접을 이루었으며 신경원체 및 근심부 가지돌기와 연접을 이루는 경우는 35.2%에 그쳤다. 이상을 종합해 보면 단일 연접성 악반사를 일으키는 구심성 신경섬유 종말부는 삼차운동신경핵에서, 동통 및 촉각 또는 감각분별등 복잡한 감각을 처리하는 감각핵에서 보다 연접후신경원에 강력한 흥분성 신호를 전달하며 또한 대단히 단순한 연접양상을 이루는 것으로 나타났다.
I-131의 주 에너지는 364 keV이고 이차적으로 637과 723 keV의 감마선을 방출한다. 이런 이유로 I-131 핵종을 이용한 검사에서는 일반적으로 고 에너지 조준기를 사용하고 있다. 반면 중 에너지 조준기는 과도한 격벽 투과의 영향 때문에 사용이 권고되지 않지만 I-131의 낮은 선량에 대해 계수율의 민감도를 향상시키기 위해 중 에너지 조준기를 사용하기도 한다. 이에 본 연구에서는 I-131 SPECT/CT에서 고 에너지와 중 에너지 조준기를 사용하여 조준기 선택에 대한 영상의 영향을 평가하고자 한다. I-131 점 선원과 NEMA NU-2 IQ phantom을 이용하여 Siemens symbia T16 SPECT/CT 장비로 중 에너지 조준기와 고 에너지 조준기를 사용하였다. 영상획득은 단일 에너지 창과 삼중 에너지 창으로 각각 적용하여 영상을 획득하였고, 재구성방법은 반복재구성 기법인 Flash 3D를 이용하여 CTAC, Scatter correction 적용 유무와 Iteration과 subset의 횟수를 변경하여 획득된 영상을 재구성하였다. 획득된 영상을 분석하여 두 조준기의 민감도와 대조도 그리고 잡음을 비교 평가하였다. 민감도는 중 에너지 조준기가 고 에너지 조준기보다 높게 나타났다(중 에너지 조준기: 188.18 cps/MBq, 고 에너지 조준기: 46.31 cps/MBq). 대조도는 삼중 에너지 창과 고 에너지 조준기를 사용하고 CTAC를 적용하여 16 subset 8 iteration을 적용한 재구성영상에서 가장 높은 대조도를 나타냈고(TCQI=190.64), 동일한 조건에서 중 에너지 조준기를 사용하였을 경우는 고 에너지 조준기에 비해 낮은 대조도를 나타냈다(TCQI=66.05). 잡음평가에서는 고 에너지 조준기보다 중 에너지 조준기에서 높게 나타났다 (P<0.001). 적절한 조준기의 선택은 영상의 질에 있어 중요한 사항이다. 본 연구를 통해 고 에너지 감마선을 방출하는 I-131 검사에서는 일반적으로 사용되고 있는 고 에너지 조준기를 사용하는 것이 영상의 질에 있어 가장 권고되는 바이다. 하지만 에너지 창, 매트릭스 크기, 반복 재구성 조건(subset과 iteration 수) 그리고 CTAC 및 scatter correction 여부등과 같은 조건들을 적절히 적용한다면 낮은 선량의 낮은 민감도를 갖는 조건에서는 중 에너지 조준기를 사용할 수 있을 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.