• Title/Summary/Keyword: 3차원 CT

Search Result 509, Processing Time 0.022 seconds

HU Threshold Value for IV Catheter Fragment in Peripheral Vein of Volume Rendering 3D MDCT Imaging (정맥 내의 IV 카테터 조각을 3D MDCT 볼륨렌더링 영상으로 구현하기 위한 HU 임계치)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.206-212
    • /
    • 2007
  • To evaluate the HU value of the IV catheter fragment of CT on the accuracy and size in the peripheral vein. Pilot study of profile and table functions on PC by software was calculated of HU value of IV catheter fragment. This study demonstrates the utility of volume rendering technique to localize a small, subtle IV catheter, which can easily be reformatted of MDCT reformations. IV catheter fragment optimal image described as threshold range. Volume rendering of HU using a MDCT is an excellent method for evaluation the IV catheter fragment in three dimension.

The Application of 3-dimensional Surface Imaging to the Early Detection of Sacroiliitis (3차원 영상기법을 이용한 천장골염의 조기 진단)

  • Jeon, Jae-Han;Kim, Seon-Il;Lee, Du-Su
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.235-242
    • /
    • 1993
  • In the early stage of sacroilitis, it is'difficult to detect sacroiliac(Sl) abnormalities by conventional plain X-ray even though there are characteristic symptoms of ankylosing spondylitis. 3 dimensional volume rendering from the CT image was performed to make an early de tection of the structural changes of Sl joint. 2 cases who had clinical impression of ankylosing spondylitis without sacroilitis in plane X-ray and 1 case of typical ankylosing spondylitis as well as 1 case of normal control were studied. The Sl Joints were separated and each joint surface of sacrum and ilium was independently reconstructed by a special 3D manipulation program. All 2 patiant who complained of inflammatory lower back pain with no abnormal findings in the plain X-ray showed structural changes in 3 dimensionally reconstructed surface Image of the Sl joint compared to the normal control. Authors tried several parameters, such as fourler analysis of each surface and the mean and variance of Sl joint gap. We couldn't tell the statistical significance because of the limited number of cases. However, the parameters showed difference according to the progression of disease.

  • PDF

Analysis of the direction of the canine and carnassial of small dog by 3D FEM (3차원 유한요소분석에 의한 소형견의 견치와 열육치의 교합력 방향 분석)

  • Park, yujin;Choi, sungmin
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.139-145
    • /
    • 2020
  • Purpose: This study is for the prosthesis of dog. Observed the occlusal relation between the small dog canine and carnassial teeth. The direction of the bite force was analyzed by 3D FEM(finite element method). Methods: The mandibular canine and carnassial of dog were tested. The skull of dog was contact point confirmed by dental CAD. The skull of dog was scaned using CT and a 3D model was created. The 3D model was analyzed ABAQUS. Closing movement has been 100N, 200N, 300N, 500N, 1000N, 1500N. The Direction of bite force was confirmed. Results: As occlusal force increased, the direction of bite force appeared to (-y), (-x,-y,-z), (-x,-y), (-x,-y,+z), (-x,-y,+ z), (+x,-y) in mandibular left canine. And the direction was seen at (+x, -y), (+x,-y,-z), (+x,-y), (-x,-y,+z), (-x,-y,+z), (+x,-y). When the occlusal load is 100 N, 200 N, 300 N, 500 N, the direction of the mandibular carnassial appears as (-x, -y, -z), and when the occlusal load is 1000 N, 1500 N, the direction appears as (-x,-y). Conclusion: The mandibular canine showed irregularities in the coordinates of the direction of the bite force, and the mandibular carnassial showed regularity in the coordinates of the direction of the bite force.

A PREDICTION OF BONY INTERFERENCE BETWEEN PROXIMAL & DISTAL SEGMENT OF THE MANDIBLE WITH INTEGRATED 3D SOLID MODEL AND DENTAL CAST IN ORTHOGNATHIC SURGERY (턱교정 수술에서 3차원 입체 모델과 치아 석고모형의 결합을 이용한 하악 근원심 골편간 간섭의 예측)

  • Kwon, Tae-Geon;Lee, Sang-Han;Kim, Jong-Bae;Nam, Ki-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.3
    • /
    • pp.163-168
    • /
    • 2003
  • Three-dimensional solid model has not been widely used in surgical prediction of orthognathic surgery because frequent artifacts from occlusal restorations or prosthesis limited the usefulness of simulated surgery involving occlusion. We prepared three-dimensional(3D) solid model from CT data and integrated the 3D solid model with dental cast using a face-bow transfer technique combined with skeletal reference measurement and confirmation with cephalometric radiographs. With this simple and easy method, it was possible to predict bony interference between the proximal and distal segment of the mandible so that we can prevent condylar displacement after sagittal split ramus osteotomy of the mandible with prominent asymmetry. The method error was within 2mm and it seemed to be useful in preoperative planning for maxillofacial surgery with maxillo-mandibular occlusal change.

Small Bowel Sparing Effect of Small Bowel Displacement System in 3D-CRT and IMRT for Cervix Cancer (자궁경부암의 3D-CRT와 IMRT시 소장전위장치의 소장 선량에 대한 영향)

  • Kang, Min-Kyu;Huh, Seung-Jae;Han, Young-Yih;Park, Won;Ju, Sang-Gyu;Kim, Kyoung-Ju;Lee, Jeung-Eun;Park, Young-Je;Nam, Hee-Rim;Lim, Do-Hoon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.130-137
    • /
    • 2004
  • Purpose : In radiotherapy for cervix cancer, both 3-dimensioal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) could reduce the dose to the small bowel (SB), while the small bowel displacement system (SBDS) could reduce the SB volume in the pelvic cavity. To evaluate the effect of the SBDS on the dose to the SB in 3D-CRT and IMRT plans, 3D-CRT and IMRT plans, with or without SBDS, were compared. Materials and Methods : Ten consecutive uterine cervix cancer patients, receiving curative radiotherapy, were accrued. Ten pairs of computerized tomography (CT) scans were obtained in the prone position, with or without SBDS, which consisted of a Styrofoam compression device and an individualized custom-made abdominal immobilization device. Both 3D-CRT, using the 4-field box technique, and IMRT plans, with 7 portals of 15 MV X-ray, were generated for each CT image, and proscribed 50 Gy (25 fractions) to the isocenter. For the SB, the volume change due to the SBDS and the DVHs of the four different plans were analyzed using palled t-tests. Results : The SBDS significantly reduced the mean SB volume from 522 to 262 cm$^{3}$ (49.8$\%$ reduction). The SB volumes that received a dose of 10$\~$50 Gy were significantly reduced in 3D-CRT (65$\~$80$\%$ reduction) and IMRT plans (54$\~$67$\%$ reduction) using the SBDS. When the SB volumes that received 20$\~$50 Gy were compared between the 3D-CRT and IMRT plans, those of the IMRT without the SBDS were significantly less, by 6$\~$7$\%$, than those for the 3D-CRT without the SBDS, but the volume difference was less than 1$\%$ when using the SBDS. Conclusion : The SBDS reduced the radiation dose to the SB in both the 3D-CRT and IMRT plans, so could reduce the radiation injury of the SB.

A Study on Simulation Effect Technique of C.G : Focusing on the Fire Simulation Effect (CG산업에서 Simulation 표현의 기술적 활용에 대한 연구 - 불의 표현 활용사례를 중심으로 -)

  • Kim, Yong-Kwan
    • Cartoon and Animation Studies
    • /
    • s.17
    • /
    • pp.188-204
    • /
    • 2009
  • This study purpose development cg technique our nation because present Technique limit of Computer graphic R&D that the best competition of 3D Computer graphic part and present a answer of how to overcome Technique limit of Computer graphic R&D with success example of Computer graphic R&D an advanced country. if we make full of mutuality supplementation of C.T and I.T then hold a dominant position and the over the limit solution We researches on multi or group simulation of cyber character and water, fire, wind, fog Simulation System of Computer graphic and purpose development of direction Computer graphic R&D to people in Computer graphic the result of this study and introduction of project of a research institution and inflection method this time is a point of R&D time of determined and resolution instead creative part.

  • PDF

Application and effects of condylectomy in asymmetric patients with condylar hyperplasia (과두과증식을 동반한 안면비대칭 환자에서 과두절제술의 적용과 효과)

  • Lim, Kyoung-Sub;Cha, Jung-Yul;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.437-455
    • /
    • 2008
  • Condylar hyperplasia is a pathologic condition showing 3-dimensional skeletal hyperplasia of the mandible. The reason for condylar hyperplasia is not yet known, but the effects of hormone, trauma, infection, genetics, fetal condition, and hypervascularity are known as possible reasons. When we diagnose a patient as having condylar hyperplasia, it is important to decide if it is in progress or not. Treatment for facial asymmetry due to condylar hyperplasia are decided accordingly, including condylectomy, that is removal of growth site of the affected condyle, and conventional orthognathic surgery only or condylectomy with orthognathic surgery after the completion of growth. Therefore, it is important to determine the growth state of condylar hyperplasia in treatment stability. This is verified through bone scan and regular check-ups with 3D CT or PA cephalogram. This case report introduces an improved case of facial asymmetry with condylectomy together with orthognathic surgery.

Feasibility Study of Isodose Structure Based Field-in-Field Technique for Total Body Irradiation (전신조사방사선치료 시 Isodose Structure를 이용한 Field-in-Field Technique의 유용성 평가)

  • Lee, Yoon Hee;Ban, Tae Joon;Lee, Woo Seok;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: In Asan Medical Center, Two parallel opposite beams are employed for total body irradiation. Patients are required to be in supine position where two arms are attached to mid axillary line. Normally, physical compensators are required to compensate the large dose difference for different parts of body due to the different thicknesses compared to the umbilicus separation. There was the maximum dose difference up to 30% in lung and chest wall compared to the prescription dose. In order to resolve the dose discrepancy occurring on different body regions, the feasibility of using Fieid-in-Field Technique is investigated in this study. Materials and Methods: CT scan was performed to The RANDO Phantom with fabricated two arms and sent to Eclipse treatment planning system (version 10.0, Varian, USA). Conventional plan with physical lead compensator and new plan using Field-in-Field Technique were established on TPS. AAA (Anisotropic Analytical Algorithm) dose calculation algorithm was employed for two parallel opposite beams attenuation. Results: The dose difference between two methods was compared with the prescription dose. The dose distribution of chest and anterior chest wall uncovered by patient arms was 114~124% for physical lead compensator while Field-in-Field Technique gave 106~107% of the dose distribution. In-vivo dosimetry result using TLD showed that the dose distribution to the same region was 110~117% for conventional physical compensator and 104~107% for Field-in-Field Technique. Conclusion: In this study, the feasibility of using FIF technique has been investigated with fabricated arms attached Rando phantom. The dose difference was up to 17% due to the attached arms. It is shown that the dose homogeneity is within ${\pm}10%$ with the CT based 3-dimensional 4 step FIF technique. The in-vivo dosimetry result using TLD was showed that 95~107% dose distribution compared to prescription dose. It is considered that CT based 3-dimensional Field-in-Field Technique for the total body irradiation gives much homogeneous dose distribution for different body parts than the conventional physical compensator method and might be useful to evaluate the dose on each part of patient body.

  • PDF

Estimation of Natural frequencies in Osteoporotic Mouse Femur: A finite Element Analysis and a Vibration Test (골다공증에 걸린 쥐 대퇴골의 고유진동수 예측: 유한 요소 해석 및 진동 실험)

  • Kim, Yoon-Hyuk;Byun, Chang-Hwan;Oh, Taek-Yul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.239-246
    • /
    • 2005
  • In this study, a finite element analysis and a vibration test were performed to estimate the natural frequencies of mouse femurs with osteoporosis. Three groups of the femurs include the osteoporotic group, the treated group and the normal group. For the finite element analysis, the micro finite element model of the femur was reconstructed using the Micro-CT images and the Voxel mesh generation algorithm. In the vibration test, the natural frequencies were measured by the mobility test. from the results, the averaged natural frequencies in the osteoporotic group were the highest, followed by those in the treated group. The finite element models were validated within 15% errors by comparing the natural frequencies in the finite element analysis with those in the vibration test. The developed Micro-CT system, the Yokel mesh generation algorithm, the presented finite element analysis, and vibration test could be useful for the investigation of the structural change of the bone tissue, and the diagnosis and the treatment in the osteoporosis.

Study of threshold and opacity in three-dimensional CT volume rendering of oral and maxillofacial area (구강악안면영역의 3차원 CT 영상 재형성시 역치 및 불투명도에 대한 연구)

  • Choi, Mun-Kyung;Lee, Sam-Sun;Huh, Kyung-Hoe;Yi, Won-Jin;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • Purpose: This study was designed to determine a proper threshold value and opacity in three-dimensional CT volume rendering of oral and maxillofacial area. Materials and Methods: Three-dimensional CT data obtained from 50 persons who were done orthognatic surgery in department of oral and maxillofacial radiology of Seoul National University retrospectively. 12 volume rendering post-processing protocols of combination of threshold(100HU, 150HU, 221HU, 270HU) and opacity (58%, 80%, 90%) were applied. Five observers independently evaluated image quality using a five-point range scale. The results were analyzed by receiver operating characteristic curves, ANOVA and Kappa value. And three oromaxillofacial surgeons chose the all images that they thought proper clinically in the all of images. Results: Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. The highest diagnostic accuracy appear with 100HU and 58% opacity. and the lowest diagnostic accuracy appear with 221HU and 58% opacity that are being used protocol in department of oral and maxillofacial radiology of Seoul National University. But, no statistically significant difference was noted between any of the protocols. And the number of proper images clinically that chosen by three oromaxillofacial surgeons is the largest in the cases of protocol 8 (221HU, opacity 80%) and protocol 11 (270HU, opacity 80%) in one after the other. Conclusion: Threshold and opacity in volume rendering can be controled easily and these can be causes of making an diagnostic accuracy. So we need to select proper values of these factors.

  • PDF