Study of threshold and opacity in three-dimensional CT volume rendering of oral and maxillofacial area

구강악안면영역의 3차원 CT 영상 재형성시 역치 및 불투명도에 대한 연구

  • Choi, Mun-Kyung (Department of Oral and Maxillofacial Radiology, Dental Research Institute and BK21, School Dentistry, Seoul National University) ;
  • Lee, Sam-Sun (Department of Oral and Maxillofacial Radiology, Dental Research Institute and BK21, School Dentistry, Seoul National University) ;
  • Huh, Kyung-Hoe (Department of Oral and Maxillofacial Radiology, Dental Research Institute and BK21, School Dentistry, Seoul National University) ;
  • Yi, Won-Jin (Department of Oral and Maxillofacial Radiology, Dental Research Institute and BK21, School Dentistry, Seoul National University) ;
  • Choi, Soon-Chul (Department of Oral and Maxillofacial Radiology, Dental Research Institute and BK21, School Dentistry, Seoul National University)
  • 최문경 (서울대학교 치의학대학원 구강악면방사선학교실, 치학연구소 및 BK21) ;
  • 이삼선 (서울대학교 치의학대학원 구강악면방사선학교실, 치학연구소 및 BK21) ;
  • 허경회 (서울대학교 치의학대학원 구강악면방사선학교실, 치학연구소 및 BK21) ;
  • 이원진 (서울대학교 치의학대학원 구강악면방사선학교실, 치학연구소 및 BK21) ;
  • 최순철 (서울대학교 치의학대학원 구강악면방사선학교실, 치학연구소 및 BK21)
  • Published : 2009.03.31

Abstract

Purpose: This study was designed to determine a proper threshold value and opacity in three-dimensional CT volume rendering of oral and maxillofacial area. Materials and Methods: Three-dimensional CT data obtained from 50 persons who were done orthognatic surgery in department of oral and maxillofacial radiology of Seoul National University retrospectively. 12 volume rendering post-processing protocols of combination of threshold(100HU, 150HU, 221HU, 270HU) and opacity (58%, 80%, 90%) were applied. Five observers independently evaluated image quality using a five-point range scale. The results were analyzed by receiver operating characteristic curves, ANOVA and Kappa value. And three oromaxillofacial surgeons chose the all images that they thought proper clinically in the all of images. Results: Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. The highest diagnostic accuracy appear with 100HU and 58% opacity. and the lowest diagnostic accuracy appear with 221HU and 58% opacity that are being used protocol in department of oral and maxillofacial radiology of Seoul National University. But, no statistically significant difference was noted between any of the protocols. And the number of proper images clinically that chosen by three oromaxillofacial surgeons is the largest in the cases of protocol 8 (221HU, opacity 80%) and protocol 11 (270HU, opacity 80%) in one after the other. Conclusion: Threshold and opacity in volume rendering can be controled easily and these can be causes of making an diagnostic accuracy. So we need to select proper values of these factors.

Keywords

References

  1. Roberts D, Pettigrew J, Udupa T, Ram C. Three-dimensional imaging and display of the temporomandibular joint. Oral Surg Oral Med Oral Pathol 1984; 58 : 461-74. https://doi.org/10.1016/0030-4220(84)90345-1
  2. Song NK, Koh KJ. Comparative study of three-dimensional reconsturctive images of facial bone using computed tomography. Korean J Oral Maxillofac Radiol 1992; 22 : 283-92 (in Korean).
  3. Cho BO, Lee YC, Kim TY, Yang YS. Clinical study of 3-dimensional computed tomography in oral and maxillofacial field. J Kor Oral Maxillofac Surg 1990; 16 : 33-41.
  4. Kawamata A, Ariji Y, Langlais RP. Three-dimensional computed tomography imaging in dentistry. Dent Clin North Am 2000; 44 : 395- 410.
  5. Calhoun PS, Kuszyk BS, Heath DG, Carley JC, Fishman EK. Threedimensional volume rendering of spiral CT data: theory and method. Radiographics 1999; 19 : 745-64. https://doi.org/10.1148/radiographics.19.3.g99ma14745
  6. Shimizu T, Yoshikawa S, Uesugi Y, Tabuchi K, Nakata Y, Matsui R, et al. Three-dimensional computed tomographic angiography of pulmonary vessels. Radiat Med 1999 Mar-Apr; 17 : 151-4.
  7. Yune HY. Two-dimensional-three-dimensional reconstruction computed tomography techniques. 1993; 37 : 613-26
  8. Parisi M, Mehdizadeh HM, Hunter JC, Finch IJ. Evaluation of craniosynostosis with three-dimensional CT imaging. J Comput Assist Tomogr 1989; 13 : 1006-12. https://doi.org/10.1097/00004728-198911000-00012
  9. Lee BD, Lee W. Influence of threshold value of computed tomography on the accuracy of 3-dimensional medical model. Korean J Oral Maxillofac Radiol 2002; 32 : 27-33 (in Korean).
  10. Kang BH, Kim KD, Park CS. Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull. Korean J Oral Maxillofac Radiol 2001; 31 : 1-7 (in Korean).
  11. Jing BS, Goeppert H, Close LG. Computerized tomography or paranasal sinus neoplasms. Laryngoscope 1978; 88 : 1485-503 https://doi.org/10.1002/lary.1978.88.9.1485
  12. Tadmor R, New PF. Computed tomography of the orbit with special emphasis on coronal sections: Part II. Pathological anatomy. J Comput Assist Tomogr 1978; 2 : 35-44. https://doi.org/10.1097/00004728-197801000-00005
  13. Kursunoglu S, Resnick D. Three-dimensional computed tomographic ananlysis of the normal TMJ. J Oral Maxillofac Surg 1986; 44 : 257-59 https://doi.org/10.1016/0278-2391(86)90075-3
  14. Wind G, Dvorak VK, Dvorak JA. Computer graphic modeling in surgery. Orthopedic Clinics of North America 1986; 17 : 657-68.
  15. Kraqskov J, Sindet-Pedersen S, Gyldensted C, Jensen KL. A comparison of three-dimensional computed tomography scans and sterolithographic models for evaluation of craniofacial anomalies. J Oral Maxillofacial Surg 1996; 54 : 402-11. https://doi.org/10.1016/S0278-2391(96)90109-3
  16. Fishman EK, magid D, Ney DR, Chancy EL, Pizer SM, Rosenman JG, et al. Three dimensional imaging. Radiology 1991; 181 : 321-37. https://doi.org/10.1148/radiology.181.2.1789832
  17. Ray CE, Mafee MF, Friedman M, Tahmoressi CN. Applications of three-dimensional CT imaging in head and neck pathology. Radiol Clin Am 1993; 31 : 181-94.
  18. Choi JY, Choi JH, Kim NK, Lee JK, Kim MK, Kim MJ, et al. Accuracy tests of 3D rapid prototyping (RP) medical models: its potential and clinical applications. J Kor Oral Maxillofac Surg 1999; 25 : 295- 303.
  19. Kim JD. Interpretation of Receiver Operating Characteristics (ROC). Korean J Oral Maxillofac Radiol 2000; 30 : 155-8 (in Korean).