• Title/Summary/Keyword: 3^{pulsed}$

Search Result 1,293, Processing Time 0.037 seconds

Temperature Changes in Dentin upon Pulsed Nd:YAG Lasing Distance (Pulsed Nd:YAG 레이저 조사거리에 따른 상아질의 온도변화)

  • Jae-Hyung Kim;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.327-334
    • /
    • 1995
  • In order to observe the influence of pulsed Nd:YAG laser at its out-of-contact with dentin on tooth temperature, we have applied pulsed Nd:YAG laser to 2mm thick dentin sample at a point of contact and from a distance of 1mm, 2mm, 3mm and 4mm with an energy of 0.3W, 0.5W, 0.8W, 1.5W and 2.0W. They were exposed to periods of 3 seconds, 6 seconds, 9 seconds and 15 seconds respectively and measured temperature changes. The results as follows : 1. When the time ad intensity of power were constant, the temperature changes on dentin of tooth depended on the distance. The temperature increased when the laser intensity increased bu two other conditions were contact. 2. At the point of contact, the temperature has risen over $5^{\circ}C$ regrdless of intensity of the power or the time. However, there was $5^{\circ}C$ fluctuation with 0.3 W for 3 seconds treatment. 3. The temperature change was less than $5^{\circ}C$ thermal change at the distance of 1mm and 2mm respectively when lased for 3 seconds, 6 seconds, 12 seconds and 15 seconds with 0.3 W. Similar results were observed at 3 and 6 seconds treatment with 0.5 W and at 3 seconds treatment with 0.8 and 1.0W respectively. 4. It showed less than 5(C thermal change when lased for 3 seconds, 6 seconds, 9 seconds, 12 seconds and 15 seconds with 0.3W at the distance of 3mm and 4mm. The same results were seen in 3 seconds, 6 seconds and 9 seconds treatment with 0.5W and in 3 seconds with 0.8W and 1.0W respectively. As we have seen the above, the results has indicated that pulsed Nd:YAG lasing at its off contact on dentin of 2mm thickness will not cause irreversible changes if lasing intensity, lasing distance and lasing time are appropriate.

  • PDF

A Study on the Improvement in Performance of Ultrasonic Pulsed Doppler Velocimeter (초음파 펄스 도플러 속도계의 성능 개선에 관한 연구)

  • 이은방;이상집
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.3
    • /
    • pp.85-95
    • /
    • 1996
  • In the velocimeter, the ultrasonic pulse signal is used for measuring the profile velocity of moving targets distributed in space because of the merits of its high distance resolution and harmless affect to the human body. The velocity reading in conventional ultrasonic pulsed velocimeter depends on the wave pattern reflecting the spatial distribution of scatters and includes observational error due to the signal processing of analyzing pulse signal. In this paper, we evaluate an influence of the received waveform of pulsed signal on the velocity information by setting a model. Subsequently, in order to improve the distance resolution and to obtain precise velocity information without the influence of the spatial distribution of scatterers, we propose a new method for the analysis of Doppler pulsed signal, in which the pulsed signal is transformed into a phase function with local data. Finally, it is confirmed that the performance of the velocimeter is more improved in the proposed method than in the conventional one.

  • PDF

Modulated Pulsed Power를 이용한 Cr 박막의 증착과 특성 분석

  • Min, Gwan-Sik;Song, Je-Beom;Yun, Ju-Yeong;Sin, Yong-Hyeon;Cha, Deok-Jun;Hwang, Yun-Seok;Heo, Yun-Seong;Kim, Jin-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.123.1-123.1
    • /
    • 2013
  • 반도체 공정에서는 사용하는 power source의 형태는 pulse-DC이다. Pulse-DC는 DC power에 비해 증착율이 좋고, 박막의 특성도 우수한 특성을 가진다. 이러한 장점에도 불구하고 pulse-DC나 DC power는 플라즈마 내 이온이 가지는 에너지가 크고, 이온화율도 낮다. 이러한 단점을 극복하기 위해 등장한 power source가 modulated pulsed power이다. Modulated pulsed power는 이온이 가지는 에너지가 DC power의 1/2 수준이며, 이온화율은 4배 이상 높은 특징을 가진다. 본 연구에서는 modulated pulsed power를 사용하여 Cr 박막을 Si wafer 위에 증착하여 박막의 특성을 관찰하였다. 연구에 사용된 power는 5 kV (800 V, 12.5 A), 20~120 KHz, 3 step까지 설정이 가능한 장비이며, base pressure $1.5{\times}10^{-6}$ Torr에서 실험이 진행되었고, 실험에 사용된 불활성 기체는 Ar을 사용하였다.

  • PDF

Application of Pulsed Chemical Vapor Deposited Tungsten Thin Film as a Nucleation Layer for Ultrahigh Aspect Ratio Tungsten-Plug Fill Process

  • Jang, Byeonghyeon;Kim, Soo-Hyun
    • Korean Journal of Materials Research
    • /
    • v.26 no.9
    • /
    • pp.486-492
    • /
    • 2016
  • Tungsten (W) thin film was deposited at $400^{\circ}C$ using pulsed chemical vapor deposition (pulsed CVD); film was then evaluated as a nucleation layer for W-plug deposition at the contact, with an ultrahigh aspect ratio of about 14~15 (top opening diameter: 240~250 nm, bottom diameter: 98~100 nm) for dynamic random access memory. The deposition stage of pulsed CVD has four steps resulting in one deposition cycle: (1) Reaction of $WF_6$ with $SiH_4$. (2) Inert gas purge. (3) $SiH_4$ exposure without $WF_6$ supply. (4) Inert gas purge while conventional CVD consists of the continuous reaction of $WF_6$ and $SiH_4$. The pulsed CVD-W film showed better conformality at contacts compared to that of conventional CVD-W nucleation layer. It was found that resistivities of films deposited by pulsed CVD were closely related with the phases formed and with the microstructure, as characterized by the grain size. A lower contact resistance was obtained by using pulsed CVD-W film as a nucleation layer compared to that of the conventional CVD-W nucleation layer, even though the former has a higher resistivity (${\sim}100{\mu}{\Omega}-cm$) than that of the latter (${\sim}25{\mu}{\Omega}-cm$). The plan-view scanning electron microscopy images after focused ion beam milling showed that the lower contact resistance of the pulsed CVD-W based W-plug fill scheme was mainly due to its better plug filling capability.

BER Analysis of Coherent Free-Space Optical Systems with Pulsed Noise Jamming (코히런트 무선 광통신 시스템에서 펄스 재밍으로 인한 비트오류율 분석)

  • Park, Hwi-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.3
    • /
    • pp.304-306
    • /
    • 2016
  • In this letter, we investigate the performance of coherent free-space optical(FSO) systems under pulsed noise jamming conditions. In particular, we derive the average bit error probability of the coherent FSO systems with the pulsed noise jamming in a closed-form. Also, we derive the optimal fraction of symbol time of the jammer. We confirm the derived average error probability expressions by the exactly matching Monte-Carlo simulation results.

Optimized Design and Manufacture of Wideband Pulsed Gamma-ray Sensors (광대역 펄스감마선 탐지센서 최적화 설계 및 제작)

  • Jeong, Sang-hun;Lee, Nam-ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.223-228
    • /
    • 2017
  • In this paper, we are proposing an optimal design of wideband pulsed type gamma-ray sensors. These sensors were manufactured based on the design results and after word electrical properties were analyzed. The sensor input parameters were derived on the basis of pulsed gamma-ray spectrum and time-dependent energy rate, and the output current which were derived on the basis of the sensor sensitivity control circuit. Pulsed gamma-ray sensors were designed using the TCAD simulators. The design results show that the optimal Epi layer thickness is 45um with the applied voltage 3.3V and the diameter is 2.0mm. The doping concentrations are as follows : N-type is an Arsenic as $1{\times}10^{19}/cm^3$, P-type is a Boron as $1{\times}10^{19}/cm^3$ and Epi layer is Phosphorus as $3.4{\times}10^{12}/cm^3$. The fabricated sensor was a leakage current, 12pA at voltage -3.3V and fully depleted mode at voltage -5V. A test result of pulsed radiation shows that the sensor gives out the optimal photocurrent.

Enhanced Induction of T Cell Immunity Using Dendritic Cells Pulsed with HIV Tat and HCMV-pp65 Fusion Protein In Vitro

  • Park, Jung-Sun;Park, Soo-Young;Cho, Hyun-Il;Sohn, Hyun-Jung;Kim, Tai-Gyu
    • IMMUNE NETWORK
    • /
    • v.11 no.3
    • /
    • pp.182-189
    • /
    • 2011
  • Background: Cytotoxic T lymphocytes (CTLs) appear to play an important role in the control and prevention of human cytomegalovirus (HCMV) infection. The pp65 antigen is a structural protein, which has been defined as a potential target for effective immunity against HCMV infection. Incorporation of an 11 amino acid region of the HIV TAT protein transduction domain (Tat) into protein facilitates rapid, efficient entry into cells. Methods: To establish a strategy for the generation of HCMV-specific CTLs in vitro, recombinant truncated N- and C-terminal pp65 protein (pp65 N&C) and N- and C-terminal pp65 protein fused with Tat (Tat/pp65 N&C) was produced in E.coli system. Peripheral blood mononuclear cells were stimulated with dendritic cells (DCs) pulsed with pp65 N&C or Tat/pp65 N&C protein and immune responses induced was examined using IFN-${\gamma}$ ELISPOT assay, cytotoxicity assay and tetramer staining. Results: DCs pulsed with Tat/pp65N&C protein could induce higher T-cell responses in vitro compared with pp65N&C. Moreover, the DCs pulsed with Tat/pp65 N&C could stimulate both of $CD8^+$ and $CD4^+$ T-cell responses. The T cells induced by DCs pulsed with Tat/pp65 N&C showed higher cytotoxicity than that of pp65-pulsed DCs against autologous lymphoblastoid B-cell line (LCL) expressing the HCMV-pp65 antigen. Conclusion: Our results suggest that DCs pulsed with Tat/pp65 N&C protein effectively induced pp65-specific CTL in vitro. Tat fusion recombinant protein may be useful for the development of adoptive T-cell immunotherapy and DC-based vaccines.

Design and Fabrication of X-Band 50 W Pulsed SSPA Using Pulse Modulation and Power Supply Switching Method (펄스 변조 및 전원 스위칭 방법을 혼용한 X-대역 50 W Pulsed SSPA 설계 및 제작)

  • Kim, Hyo-Jong;Yoon, Myoung-Han;Chang, Pil-Sik;Kim, Wan-Sik;Lee, Jong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.4
    • /
    • pp.440-446
    • /
    • 2011
  • In this paper, a X-band 50 W pulsed solid state power amplifier(SSPA) is designed and fabricated for radar systems. The SSPA consists of a driver amplifier, a high power amplifier, and a pulse modulator. The high power stage employes four 25 W GaAs FET to deliver 50 W at X-band. To meet the stringent target specification for the SSPA, we used a new hybrid pulse switching method, which combine the advantage of pulse modulation and bias switching method. The fabricated SSPA shows a power gain of 44.2 dB, an output power of 50 W over a 1.12 GHz bandwidth. Also, pulse droop < 1 dB meet the design goals and a rise/fall time is less than 12.45 ns. Fabricated X-band pulsed SSPA size is compact with overall size of $150{\times}105{\times}30\;mm^3$.

STUDY ON HIGH SPEED WELDING IN GTA WELDING PROCESS

  • Cui Li;Jeong, Ho-Shin;Park, Byung-Il;Kim, Sung-Kab
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.89-93
    • /
    • 2002
  • A study of noticeable improvement in welding speed in thin-plate Type 304 stainless steels gas tungsten arc (GTA) welding was investigated. The welding speeds were increased to more than 3m/min, up to 8m/min. During the welding, Direct Current Straight Polarity (DCSP) and pulsed current GTA welding processes were carried out, respectively. The appropriate high speed welding parameters were established while achieving a high quality weld. After this, Erichsen test and tensile test were performed. The results obtained wert summarized as following: ultra high speed welding for thin-plate Type 304 could be satisfactorily welded with high speed from 3m/min to 8m/min in both DCSP and pulsed GTA welding; Increasing welding speed was found to decrease the ductility, tensile strength md elongation of welded joint; The optimal frequency would be 200Hz-500Hz for high speed welding in pulsed current welding; DCSP welding could obtain the better results of Erichsen test and tensile test than those of pulsed current welding obtained.

  • PDF

The Effect of Wound Healing of Pulsed Ultrasound and Chitosan in Diabetic Induced Model (당뇨유발 모델에서 맥동성초음파와 키토산의 창상치유효과)

  • Kim Gye-Yeop;Min Soon-Gyu;Cheong Mee-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.50-64
    • /
    • 2004
  • The studies have been designed to evaluate the effect of wound healing of pulsed ultrasound and chitosan application in diabetic incisive wound of rats. Mild diabetes mellitus was induced in rat used 30 mg/kg streptozotocin. Full thickness skin incision was made on the backs of Sprague-Dawley rats. We used 72 Sprague-Dawley rats which were divided into 4 groups; the subjects were divided into group of 6 rats each 3, 6, and 15 days. The results were summarized as follows; The rate of wound length of pulsed ultrasound with chitosan application groups more decreased than only pulsed ultrasound treatment group. The density of inflammatory cells in the experimental groups was more significantly decreased than diabetic control group(p<0.05). Historically, in the ultrasound with chitosan application groups, reepithelized epithelium was thicker and the collagen fiber were organized in a liner manner and connective tissue was matured faster those of the diabetic control group(p<0.05). From the conclusions above, in this study application of pulsed ultrasound and chitosan can be an effective way of promotion of wound healing in diabetic model.

  • PDF