• Title/Summary/Keyword: 2DOF

Search Result 663, Processing Time 0.033 seconds

Effects of Fruits and Stems of Opuntia ficus-indica on Blood Glucose and Lipid Metabolism in Streptozotocin-induced Diabetic Rats (손바닥선인장의 열매와 줄기가 Streptozotocin으로 유발된 당뇨 쥐의 혈당 및 지질대사에 미치는 영향)

  • Yoon, Jin-A;Son, Yong-Suk
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.2
    • /
    • pp.146-153
    • /
    • 2009
  • This study was conducted to examine the effects of fruits and stems of Opuntia ficus-indica var. saboten Makino on water intake, feed intake, body weight, blood glucose level and glucose tolerance in streptozotocin (STZ)-induced diabetic rats. Forty Sprague-Dawley male rats were divided into non-diabetic control (NC), diabetic control (DC), 8% Opuntia fruit (DOF), 5% Opuntia stem (DO-5) and 10% Opuntia stem (DO-10) groups. Fruits and stems of Opuntia ficus-indica were freeze-dried and ground before use in the experiment. Animals were fed experimental diet for 3 weeks. DOF, DO-5 and DO-10 groups showed lower water and feed intake as well as less body weight loss than DC group. The fasting blood glucose levels were 100 mg/dL for NC and 379 mg/dL for DC. Fasting glucose level of DOF was a significantly low level of 28% (p<0.05), whereas DO-5 and DO-10 had a decrease of 5% and 9% compared to DC. As for the glucose tolerance test, the highest blood glucose levels for NC and DC-10 group were observed at 30 minutes after glucose injection while those of DOF and DO-5 groups were after 60 minutes. DOF and DO-5 plasma insulin level improved. Plasma total cholesterol, triglyceride, non-esterified fatty acid (NEFA) and LDL-cholesterol concentrations were also lower in DOF, DO-5 and DO-10 groups, although HDL-cholesterol level was only slightly affected by experimental diets compared to DC. These results suggest that the feeding of Opuntia ficus-indica fruits and stems improved blood glucose and lipid metabolism in STZ-induced diabetic rats.

A Design of 2 DOF PID Controller Using Performance Index (평가지표를 이용한 2자유도 PID제어기 설계)

  • 유항열;이정국;이금원;이준모
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.66-72
    • /
    • 2004
  • PID control has been well used for several decades. For PID algorithms, some tuning methods are used for selecting PID parameters and with these selected parameters, PID control system is designed. But in some cases various kinds of performance indices are used instead of well-known tuning rules, and so variable type of performance index must be tested so that the designed control system meets the some specifications. For 2 DOF PID controller design this paper presents a linear combinational type of performance indices constituting of index for robust performance, which is obtained by h infinity norm of a weighted complementary sensitivity function, including other time domain indices such as error, energy and changing rate of control input. By numerical methods, the optimal 2 DOF PID parameters are obtained. Therefore various types of 2 degree of freedom PID controllers such as I-PD controller are used so that this two degree of freedom PID controllers may give more desirable output characteristics. Simulations are done with MATLAB m file and mdl files.

  • PDF

Added Resistance and 2DOF Motion Analysis of KVLCC2 in Regular Head Waves using Dynamic Overset Scheme (동적 중첩격자 기법을 이용한 KVLCC2의 파랑중 부가저항 및 2자유도 운동 해석)

  • Kim, Yoo-Chul;Kim, Yoonsik;Kim, Jin;Kim, Kwang-Soo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.5
    • /
    • pp.385-393
    • /
    • 2018
  • In this study, the analysis of 2DOF (2 Degree Of Freedom) motion and added resistance of a ship in regular head waves is carried out using RANS (Reynolds Averaged Navier-Stokes) approach. In order to improve the accuracy for large amplitude motions, the dynamic overset scheme is adopted. One of the dynamic overset schemes, Suggar++ is applied to WAVIS which is the in-house RANS code of KRISO (Korea Research Institute of Ships and Ocean Engineering). The grid convergence test is carried out using the present scheme before the analysis. The target hull form is KRISO VLCC tanker (KVLCC2) and 13 wave length conditions are applied. The present scheme shows the improved results comparing with the results of WAVIS2 in the non-inertial reference frame. The dynamic overset scheme is confirmed to give the comparatively better results for the large amplitude motion cases than the non-inertial frame based scheme.

Design of Two-DOF Optimal Controller for Strip Gage and Tension Control of Cold Tandem Mills Using Reference Shaping Filter and Disturbance Observer (목표치 정형화 및 외란 관측기를 활용한 연속 냉간압연 시스템의 2-자유도 스트립 두께 및 장력 최적 제어기 설계)

  • Hong, Wan-Kee;Kang, Hyun-Seok;Hwang, I-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.237-244
    • /
    • 2012
  • This paper studies the design of a two-DOF optimal controller for the strip gauge-tension of cold tandem mill processes, that uses a reference shaping filter and a disturbance observer. First, a mathematical model of the strip gauge and tension system is constructed using the gauge meter equation and Hooke's law, respectively. Next, a two-DOF controller considering of a feedforward controller and a feedback controller is designed. The former is based on the reference shaping filter and the disturbance observer, and the latter is based on the ILQ optimal control algorithm. Finally, it is shown through a computer simulation that the proposed optimal controller is able to improve the strip gauge accuracy and the tension variation more than the conventional MV-AGC controller.

Design of Robust DC-DC Converter by High-Order Approximate 2-Degree-of-Freedom Digital Controller

  • Takegami, E.;Tomioka, S.;Watanabe, K.;Higuchi, K.;Nakano, K.;Kajikawa, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.232-237
    • /
    • 2004
  • In many application of DC-DC converters, loads cannot be specified in advance, i.e., their amplitudes are suddenly changed from the zero to the maximum rating. Generally, design conditions are changed for each load and then each controller is re-designed. Then, a so-called robust DC-DC converter which can cover such extensive load changes and also input voltage changes with one controller is needed. Analog control IC is used usually for the controller of DC-DC converter. Simple integral control etc. are performed with the analog control IC. However it is difficult to retain sufficient robustness of DC-DC converter by these techniques. The authors proposed the method of designing an approximate 2-degree-of-freedom (2DOF) controller of DC-AC converter. This controller has an ability to attain sufficient robustness against extensive load and DC power supply changes. For applying this approximate 2DOF controller to DC-DC converter, it is necessary to improve the degree of approximation for better robustness. In this paper, we propose a method of designing good approximate 2DOF digital controller which makes the control bandwidth wider, and at the same time makes a variation of the output voltage very small at a sudden change of resistive load. The proposed good approximate 2DOF digital controller is actually implemented on a DSP and is connected to a DC-DC converter. Experimental studies demonstrate that this type digital controller can satisfy given specifications.

  • PDF

A study on the application of the intelligent control algorithms to the flow control system (유량제어계통에 대한 지능형 제어 알고리즘 적용연구)

  • 김동화;조일인
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1792-1795
    • /
    • 1997
  • It is difficulte to control in the flow system because there are many disturbance. So it is impossible to control delicately sometimes by PI or PID. In this paper, we study on the application of intellignet control algorithms such as 2DOF PID control, neural network, Fuzzy contro, Relay feedback to the flow control system. the resultings are 2DOF-PID control is more good response.

  • PDF

Multivariable control of robot manipulators using fuzzy logic (퍼지논리를 이용한 로봇 매니퓰레이터의 다변수제어)

  • 이현철;한상완;홍석교
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.490-493
    • /
    • 1996
  • This paper presents a control scheme for the motion of a 2 DOF robot manipulator. Robot manipulators are multivariable nonlinear systems. Fuzzy logic is avaliable human-like control without complex mathematical operation and is suitable to nonlinear system control. In this paper, Implementation of fuzzy logic control of robotic manipulators shows. Algorithm has been performed with simulation packages MATRIXx and SystemBuild.

  • PDF

Haptic Device For Haptic Interaction With Virtual Environment (가상환경과 촉감적 상호작용을 위한 햅틱 디바이스)

  • 정영훈;이재원;주해호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.27-30
    • /
    • 2000
  • In this paper, we determine the design criteria of haptic device considering the human haptic system and determine the design specifications. We developed a new 2DOF haptic device based on the specifications. It has the wide workspace, statically-balanced, constant inertia matrix, well-conditioned Jacobian matrix and so on. There also is not singularity point within workspace of the device. We show that it has better performance than other 2DOF haptic device in the many aspects.

  • PDF

The Effect of Impact Absorbing System with 2 DOF Deformation According to the Variation of Cylinder Wall on Damping Coefficient (실린더 벽면 변화가 2자유도계 충격흡수장치의 감쇠계수에 미치는 영향)

  • Han, Geun-Jo;Ahn, Chan-Woo;Ahn, Sung-Chan;Shim, Jae-Joon;Kim, Sung-Youn
    • Journal of Navigation and Port Research
    • /
    • v.26 no.1
    • /
    • pp.101-105
    • /
    • 2002
  • Many malfunction take place in container crane spreader due to impact. So we designed a 2 DOF hydraulic impact absorbing equipment to absorb the impact and we studied the change of damping coefficient with respect to the variation of dimensions of oil-Cylinder wail. When we design the dimension of hydraulic cylinder wall considering the displacement on the wall, the value of it over 20m didn't affect the damping coefficient.

Laser pose calibration of ViSP for precise 6-DOF structural displacement monitoring

  • Shin, Jae-Uk;Jeon, Haemin;Choi, Suyoung;Kim, Youngjae;Myung, Hyun
    • Smart Structures and Systems
    • /
    • v.18 no.4
    • /
    • pp.801-818
    • /
    • 2016
  • To estimate structural displacement, a visually servoed paired structured light system (ViSP) was proposed in previous studies. The ViSP is composed of two sides facing each other, each with one or two laser pointers, a 2-DOF manipulator, a camera, and a screen. By calculating the positions of the laser beams projected onto the screens and rotation angles of the manipulators, relative 6-DOF displacement between two sides can be estimated. Although the performance of the system has been verified through various simulations and experimental tests, it has a limitation that the accuracy of the displacement measurement depends on the alignment of the laser pointers. In deriving the kinematic equation of the ViSP, the laser pointers were assumed to be installed perfectly normal to the same side screen. In reality, however, this is very difficult to achieve due to installation errors. In other words, the pose of laser pointers should be calibrated carefully before measuring the displacement. To calibrate the initial pose of the laser pointers, a specially designed jig device is made and employed. Experimental tests have been performed to validate the performance of the proposed calibration method and the results show that the estimated displacement with the initial pose calibration increases the accuracy of the 6-DOF displacement estimation.