• 제목/요약/키워드: 2D grid analysis

검색결과 215건 처리시간 0.026초

비정렬격자계를 사용하는 3차원 유동해석코드 개발 (II) - 코드성능평가 - (Development of 3-D Flow Analysis Code Using Unstructured Grid System (II) - Code's Performance Evaluation -)

  • 김종태;김종은;명현국
    • 대한기계학회논문집B
    • /
    • 제29권9호
    • /
    • pp.1057-1064
    • /
    • 2005
  • A conservative finite-volume numerical method using unstructured meshes, which is developed by the authors, is evaluated for its application to several 2-D benchmark problems using a variety of quadrilateral, triangular and hybrid meshes. The present pressure-based numerical method for unstructured mesh clearly demonstrates the same accuracy and robustness as that fur typical structured mesh.

PGA (Pin Grid Array) 패키지의 응력해석 및 Lead Pin 형상설계 (Stress Analysis and Lead Pin Shape Design in PGA (Pin Grid Array) Package)

  • 조승현;최진원
    • 마이크로전자및패키징학회지
    • /
    • 제18권2호
    • /
    • pp.29-33
    • /
    • 2011
  • 솔더와 PCB Cu 패드와 솔더 경계면에서 발생하는 수직응력과 수평응력을 분석하여 PGA 패키지의 신뢰성 향상을 위한 리드핀의 형상설계에 대한 연구를 수행하였다. 이와 같은 연구를 위해 리드핀의 $20^{\circ}$ 각도 굽힘 변형과 50 ${\mu}m$ 인장조건에서 4인자 3수준의 다구찌 최적설계와 유한요소해석을 수행하였다. 해석결과에 의하면 리드핀의 헤드곡면과 PCB Cu 패드가 접촉하는 폭(d2)이 솔더에서 발생하는 응력감소에 가장 큰 영향을 미치는 인자로 계산되었다. 또한, 다 구찌법의 파라메타 설계에 의해 기존 리드핀 형상모델에 비해 약 18.7%의 등가 von Mises 응력이 감소하는 형상을 도출하였다. 한편, 최대 수직응력이 발생하는 위치가 PCB의 Cu 패드와 솔더의 외곽이 접촉하는 위치이고 최대 수평응력이 발생하는 위치가 SR 층과 솔더의 외곽표면이 접촉하는 위치임을 파악하여, PGA 패키지의 박리 불량은 솔더의 외곽부터 발생하여 내부로 진행될 것으로 예측되었다.

Eulerian-Lagrangian 방법에서 입자 및 유동 격자계 분리를 통한 2상 유동의 효율적 계산 (Efficient Computation of Two-Phase Flow by Eulerian-Lagrangian Method Using Separate grids for the Particles and Flow Field)

  • 박순일;이진규;장근식
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 추계 학술대회논문집
    • /
    • pp.43-48
    • /
    • 2003
  • When the Eulerian-Lagrangian method is used to analyze the particle laden two-phase flow, a large number of particles should be used to obtain statistically meaningful solutions. Then it takes too much time to track the particles and to average the particle properties in the numerical analysis of two-phase flow. The purpose of this paper is to reduce the computation time by means of a set of particle gird separate to the flow grid. Particle motion equation here is the simplified B-B-O equation, which is integrated to get the particle trajectories. Particle turbulent dispersion, wall collision, and wall roughness effects are considered but the two-way coupling effects between gas and particles are neglected. Particle laden 2-D channel flow is solved and it is shown that the computational efficiency is indeed improved by using the current method

  • PDF

새로운 개념의 고압 발전기 설계 및 특성분석 (The New High Voltage Generator's Design and Performance Analysis)

  • 김창화;황돈하;박도영;김용주;권영안;류동근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.696-698
    • /
    • 2000
  • A new high voltage generator is designed and basic performance analysis by 2D-FEA is performed. The new generator is able to supply electricity directly to the high voltage grid without the need for a step-up transformer. For the 2D-FEA analysis, the generator model is coupled to external circuit components with inductance and end-winding resistance.

  • PDF

Haar 웨이블릿 다중분해능 시간영역 해석법을 이용한 마이크로파 소자 해석 (Applications of Haar Wavelet Based Multiresolution Time-Domain Method to Microwave Structures)

  • 주세훈;김형훈;김형동
    • 한국전자파학회논문지
    • /
    • 제10권6호
    • /
    • pp.935-950
    • /
    • 1999
  • A multiresolution time-domain analysis scheme is derived for the analysis of microwave structures by using Haar wavelets to discretize the Maxwell's curl equation. This technique requires less computational effort than the conventional FDTD method because larger space grid can be used in the simulations. To validate this scheme, several 2-D·3-D microwave structures are simulated and the results are compared with those of the conventional FDTD scheme.

  • PDF

부하평준화 기능을 고려한 주택용 ESS의 적정 지원금 산정에 관한 연구 (A Study on the Decision of Appropriate Subsidy Levels for Energy Storage Systems Considering Load Leveling in Smart Place)

  • 김정훈;황성욱;이학주
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.211-216
    • /
    • 2014
  • Construction of power plants and T&D facilities is so difficult because of the civil complaints and the additional cost according to the concerning field conditions. Therefore, various researches and methods have been considered to get solutions in the demand side and energy storage systems have been in the spotlight because of the various functions such as peak shaving, load shifting, and power system stabilizing, and so on. Residential small size batteries are considered in this paper and the economic analysis is carried out to evaluate the reasonable subsidy levels for the deployment of energy storage systems. Various economic parties are considered to find reasonable subsidy level comparing each other, which parties consist of utilities, participants and non-participants in general. The evaluation is based on California Standard Practice Test and the results are able to be used as subsidy guidelines.

V2G 전기자동차의 부하관리 자원 활용을 위한 적정 지원금 산정에 관한 연구 (A Study on the Decision of Appropriate Subsidy Levels Regarding Electric Vehicles for V2G as Load Management Resources)

  • 김정훈;황성욱
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.264-268
    • /
    • 2016
  • Recently, various energy efficiency optimization activities are ongoing globally by integrating conventional grids with ICT (Information and Communication Technology). In this sense, various smart grid projects, which power suppliers and consumers exchange useful informations bilaterally in real time, have been being carried out. The electric vehicle diffusion program is one of the projects and it has been spotlighted because it could resolve green gas problem, fuel economy and tightening environmental regulations. In this paper, the economics of V2G system which consists of electric vehicles and the charging infrastructure is evaluated comparing electric vehicles for V2G with common electric vehicles. Additional benefits of V2G are analyzed in the viewpoint of load leveling, frequency regulation and operation reserve. To find this benefit, electricity sales is modeled mathematically considering depth of discharge, maximum capacity reduction, etc. Benefit and cost analysis methods with the modeling are proposed to decide whether the introduction of V2G systems. Additionally, the methods will contribute to derive the future production and the unit cost of electric vehicle and battery and to get the technical and economic analysis.

범용 열/유체 유동해석 프로그램 NUFLEX의 개발 (DEVELOPMENT OF GENERAL PURPOSE THERMO/FLUID FLOW ANALYSIS PROGRAM NUFLEX)

  • 허남건;원찬식;유홍선;손기헌;김사량
    • 한국전산유체공학회지
    • /
    • 제12권2호
    • /
    • pp.8-13
    • /
    • 2007
  • A general purpose program NUFLEX for the analysis 3-D thermo/fluid flow and pre/post processor in complex geometry has been developed, which consists of a flow solver based on FVM and GUI based pre/post processor. The solver employs a general non-orthogonal grid system with structured grid and solves laminar and turbulent flows with standard/RNG $k-{\varepsilon}$ turbulence model. In addition, NUFLEX is incorporated with various physical models, such as interfacial tracking, cavitation, MHD, melting/solidification and spray models. For the purpose of evaluation of the program and testing the applicability, many actual problems are solved and compared with the available data. Comparison of the results with that by STAR-CD or FLUENT program has been also made for the same flow configuration and grid structure to test the validity of NUFLEX.

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • 신재생에너지
    • /
    • 제2권3호
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

고입사각 압축기 익렬 내의 3차원 난류유동에 관한 수치적 연구 (Numerical Study for 3D Turbulent Flow in High Incidence Compressor Cascade)

  • 안병진;정기호;김귀순;임진식;김유일
    • 한국추진공학회지
    • /
    • 제6권3호
    • /
    • pp.29-36
    • /
    • 2002
  • 2차원, 3차원 비압축성 Navier-Stokes 방정식을 이용하여 DCA 압축기 익렬의 수치해석을 수행하고, 여러 가지 입사각에 대해 실험치와 비교.검토하였다. SIMPLE 알고리즘을 적용한 2차원, 3차원 코드는 대류항의 이산화에 하이브리드 도식을, 집중격자기법을 사용할 때 발생할 수 있는 압력진동해를 방지하기 위하여 PWIM을 사용하였다. 캐스케이드 유동을 예측하는데 있어서 가장 중요한 요소 중의 하나가 난류모델링이다. 이는 캐스케이드 내의 유동이 역압력구배에 의한 박리와 재부착 등의 복잡한 양상을 보이기 때문이다. 본 연구에서는 계산시간의 효율성을 고려해 $\kappa$-$\varepsilon$ 벽법칙 모델을 사용하였다.