• Title/Summary/Keyword: 2D Materials

Search Result 6,150, Processing Time 0.048 seconds

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

A mixed infection of epitheliocystis, Microcotyle sebstes and unknown aetiology in cultured rockfish (Sebastes schlegeli) from farms in Huksan Island (양식 조피볼락(Sebastes schlegeli)의 Epitheliocystis, Microcotyle sebastes 및 미동정 생물체의 혼합감염)

  • Park, Sung-Woo;Yu, Jin-Ha;Lee, Kyung-Hee
    • Journal of fish pathology
    • /
    • v.22 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Fifteen diseased rockfish (Sebastes schlegeli) were collected from 4 net-cage farms in Huksan island. Some round transparent nodules were observed on gill filaments in fish. Bacteriological and histopathological examinations on the diseased fish were performed. Any pathogenic bacteria could not be isolated from the internal tissues and histopathological alterations were not found in any of the tissues except the gills. Rock fish were infected with epitheliocystis, Microcotyle sebastes and unknown aetiology on the gills. Cysts of epitheliocystis measuring 44.1-68.9 $\mu{m}$ in diameter were mainly found in the distal portion of the gill filaments and sometimes in the middle portion. But host responses were moderate in spite of formation of the epithelial cysts. Some Microcotyle sebastes captured the secondary filaments with clamps on the opisthohaptor. Attachment of the parasites provoked epithelial proliferation and resulted in gill lamellar fusion.Cysts of unknown origins measuring 26-425 $\mu{m}$ in diameter were found in the cartilage of gill filaments. These cysts contained eosinophilic materials and proliferation of cartilage cells was confirmed around the cysts. But there was no significant pathological changes associated with the presence of the cysts except enlargement of the gill filament with the cysts.

FLEXION EFFECTS OF HEAT TREATMENT AND POST-SOLDRING OF CERAMO-METAL FIXED PARTIAL DENTURE FRAMEWORKS USING HOLOGRAPHIC INTERFEROMETRY (Holographic Interferometry를 이용한 하악 구치부 도재소부 전장관용 금속 구조물의 굴곡성향에 대한 연구)

  • Choi, Jin-Woong;Woo, Yi-Hyung;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.869-902
    • /
    • 1996
  • Flexion of a metal/ceramic fixed partial denture(EPD) frameworks under function can cause fracture of porcelain or deterioration of the cement seal. This study evaluated the flexion characteristics of three-unit mandibular FPD frameworks, repacing the second pre-molar under compressive load(200g, 400g). Testing was accompished with real-time holographic interferometry, using 6 porcelain fused-to metal frameworks. Tested alloys were non-precious alloy(Heracles, Holland), semi-precious alloy(Degudent U, Germany) and precious alloy(Degudent H, Germany). Changes of the fringe patterns according to the heat treatment(porcelain firing cycle), various loads(200g, 400g), occlusal forms(occlusal porcelain veneering, facial porcelain veneering), various alloys and post-soldering units were compared. Dental study model(Nissan dental products, Inc. D51DP-500A, Japan) and six 3-unit metal/ceramic fixed partial denture frameworks were used as experimental materials. 36 holograms were taken on fixed dental study model by using the 10mW He-Ne laser and real-time holographic interferometry. On the basis of this study, the following conclusions can be drawn : 1. In the frameworks for facial porcelain veneering, the semi-precious alloy framework was least deformed and precious alloy framework, non-precious alloy framework orderly before heat treatment, and the deformation was not shown great difference among three alloys after heat treatment and post-soldering. 2. In the frameworks for occlusal porcelain veneering, the precious alloy framework was greatest deformed and the deformation was not difference between semi-precious alloy framework and non-precious alloy framework before, after heat treatment, and the deformation was not shown great difference among three alloys after post soldering. 3. In the non-precious alloy frameworks for facial porcelain veneering and occlusal porcelain veneering, the deformation was greatly decreased after heat treatment and conversely increased after post-soldering. 4. In the semi-precious alloy framework for facial porcelain veneering, the deformation was not detectable after heat treatment and increased after post-solder. And in the frame-work for occlusal porcelain veneering, the deformation was slightly decreased after heat treatment and increased after post-soldering. 5. In the precious alloy framework for facial porcelain veneering, the deformation was greatly decreased after heat treatment and increased after post-soldering, And in the framework for occlusal porcelain veneering, the deformation was greatly decreased after heat treatment and decreased after post-soldering.

  • PDF

Effect of head positioning on the vertical and horizontal magnification in panoramic radiographs: rotation along the sagittal and transverse plane (파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향: 상하 및 좌우회전)

  • Kim, Yong-Gun;Byun, Jin-Seok;An, Seo-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the effect of head position changes on vertical and horizontal magnification in dental panoramic radiographs. Materials and Methods: Five 4 mm metal balls were placed above alveolar crest of dry skull considering extraction socket and dental arch. Panoramic radiographs were taken by OP-100D (Instrumentarium Imaging Co., Tuusula, Finland) at proper and rotated head position along the sagittal and transverse axis at 3 - $20^{\circ}$ upwardly, downwardly, to the left and to the right rotation. Images were stored in DICOM files and were measured by ruler equipped within INFINITT PACS software. Results: The mean horizontal magnification was $1.22{\pm}0.01-1.44{\pm}0.01$ and mean vertical magnification was $1.29{\pm}0.00-1.35{\pm}0.02$ at standard head position. There was statistical significance of horizontal magnification between the anterior ($1.24{\pm}0.02-1.31{\pm}0.03$) and the posterior area ($1.40{\pm}0.03-1.33{\pm}0.02$) (P < 0.05). Vertical magnification resulted in less variation ($1.24{\pm}0.01-1.37{\pm}0.02$) than horizontal magnification ($0.88{\pm}0.03-3.73{\pm}0.16$) according to the rotation. There was statistical significant difference on horizontal magnification (P < 0.05). Conclusion: In rotated head position, the horizontal magnification should be considered because these can cause distortion on panoramic radiographs.

Effect of Electropolishing on Surface Quality of Stamped Leadframe (Stamped Leadframe의 표면 품질에 미치는 전해연마 효과)

  • 남형곤;박진구
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.3
    • /
    • pp.45-54
    • /
    • 2000
  • The effect of electropolishing far stamped leadframe on the removal of the edge burr and residual stress relief was examined. The present study showed that the electropolishing could be used for enhanced surface quality of stamped leadframes. The electropolishing was performed at the condition of 60% phosphoric acid electrolyte, 5 ampere of current and 3 cm electrode gap at $70^{\circ}C$ for 2 minutes for Alloy42 type leadframe, and $50^{\circ}C$ for 1.5 minutes for C-194 type leadframe. The FWHM values from X-ray diffraction showed that residual stress of electropolished leadframe recovered to the level of as-received raw materials and surface roughness measured by using AFM tuned out to be improved by 0.079 $\mu\textrm{m}$ and 0.014 $\mu\textrm{m}$ ($R_{rms}$) far alloy 42 and C-194 type leadframes, respectively. The plated thickness using XRF showed the improved uniformity in thickness variation by 0.4~0.5 $\mu\textrm{m}$ and grain growth, which is favorable for interface adhesion, was also observed from the bake test samples. We could certify dimensional stability of leadframe with inspection by means of 3D-topography and hardness measurements.

  • PDF

Validation of a New Design of Tellurium Dioxide-Irradiated Target

  • Fllaoui, Aziz;Ghamad, Younes;Zoubir, Brahim;Ayaz, Zinel Abidine;Morabiti, Aissam El;Amayoud, Hafid;Chakir, El Mahjoub
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1273-1279
    • /
    • 2016
  • Production of iodine-131 by neutron activation of tellurium in tellurium dioxide ($TeO_2$) material requires a target that meets the safety requirements. In a radiopharmaceutical production unit, a new lid for a can was designed, which permits tight sealing of the target by using tungsten inert gaswelding. The leakage rate of all prepared targets was assessed using a helium mass spectrometer. The accepted leakage rate is ${\leq}10^{-4}mbr.L/s$, according to the approved safety report related to iodine-131 production in the TRIGA Mark II research reactor (TRIGA: Training, Research, Isotopes, General Atomics). To confirm the resistance of the new design to the irradiation conditions in the TRIGA Mark II research reactor's central thimble, a study of heat effect on the sealed targets for 7 hours in an oven was conducted and the leakage rates were evaluated. The results show that the tightness of the targets is ensured up to $600^{\circ}C$ with the appearance of deformations on lids beyond $450^{\circ}C$. The study of heat transfer through the target was conducted by adopting a one-dimensional approximation, under consideration of the three transfer modes-convection, conduction, and radiation. The quantities of heat generated by gamma and neutron heating were calculated by a validated computational model for the neutronic simulation of the TRIGA Mark II research reactor using the Monte Carlo N-Particle transport code. Using the heat transfer equations according to the three modes of heat transfer, the thermal study of I-131 production by irradiation of the target in the central thimble showed that the temperatures of materials do not exceed the corresponding melting points. To validate this new design, several targets have been irradiated in the central thimble according to a preplanned irradiation program, going from4 hours of irradiation at a power level of 0.5MWup to 35 hours (7 h/d for 5 days a week) at 1.5MW. The results showthat the irradiated targets are tight because no iodine-131 was released in the atmosphere of the reactor building and in the reactor cooling water of the primary circuit.

Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology (Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가)

  • Kim, Eun-Ji;Lee, Kyu-Bok;Jin, Myoung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.

The Eastern and Western Medical Investigation on the Relation with I.I.C.P and Kwul (두개내압상승(頭蓋內壓上昇)과 궐의(厥) 상관성(相關性)에 대(對)한 동서의학적(東西醫學的) 고찰(考察))

  • Jung, Seung-Hyun;Park, Seong-Sik;Lee, Won-Chul
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.3
    • /
    • pp.237-267
    • /
    • 1994
  • The purpose of this study is the approach to I.I.C.P. centered on the meaning of consciousness disorder and the pathological aspect of Kwul (Jose consciousness ; faint, fall into a coma). The meaning of consciousness disorder and apoplexy is evidently involved the definition of Kwul. 1. It is found that the etymological interpretation on Kwul which the energy rises back to go through blocked space and the meaning interpretation of regarding Kwul as apoplexy with medical viewpoint, are related with consciousness disorder and motor disturbance in IICP in the aspect of the rise of Kwul and the abnormal rising of vital energy and blood, In addtion, the overall of meaning of Kwul is showed in table <1-1> by reference to doctors of many generations, 2. The pathology of Kwul includes abnormal rising, sthenia-syndrome in the upper part and asthenia in the lower, the origin of Kwul, the lower, looking like Yin by too sthenic Yang and looking like Yang by too sthenic Yin. The headache, vomiting, papilledema, paralysis of nervi craniales, coma, blood pressure rising, tachycardia by I.I.C.P can be regarded as a conception of trouble of vital energy, sthenia-syndrome of Kwul. The pulse pressure, brachycardia, bradypnea can be regarded as the conception of looking like Yin by too sthenic Yang. 3. In the emergency of Kwul, the abnormal ternimal reversion of the Kwulyin channel, Kuyang channel, and three Yins are related with the phenomenon in I.I.C.P. It is considered that the reverse movement of materials, I.I.C.P. can be closely observed by giving meaning on the meridian of Kwul in Somunkwulron. And the content of phrases of Naelyung which includes consciousness disorder refered in the chapter of Kwul, is compared with I.I.C.P. 4. The followings should be considered; examination of optic symptom and abnormal posture in cerebral herniation ; understanding and working out counterplans of factors and symptoms of consciousness disorder by the observation of vital sign, check of general stages, neurologic inverstigation, clinical diagnosis, and subsidiary diagnosis; application of morphological change of opinion; addtion of the conception of demonstration centered on Yunkyung, Samyinkwulruk, asthenia and thenia of healthy energy in oriental medicine. 5. The similarity of Kwul and I.I.C.P. can be found from etiology and pathotenic factor. The similarity is clearly found by investigation of etiology, pathotenic factor, symptoms and thrapy of Kwul, disease symptom ar.d other symptoms.

  • PDF

A Study of Signal Intensity of MRA in Flow Phantom of Fusiform Aneurysm (방추형 동맥류 모형에서 자기공명 혈관조영술의 신호강도에 대한 연구)

  • 한기석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.83-88
    • /
    • 1998
  • Purpose : Authors correlated the three-dimensional time-of-flight MRA signal intensity characteristics and flow profile simulated by computer in an experimental flow phantom model. Materials and Methods : The three-dimensional time-of-flight MRA was performed in a fusiform flow phantom and analyzed the flow signal. computer assisted flow simulation was performed in same flow geometry. The MRA signal intensity and flow velocity distribution and direction was compared. Results : The flow was depicted as homogeneous signal internsity in inlet and outlet area and inhomogeneous signal intensity in fusiform area. Typically, the flow was depicted as target appearance in transition area to outlet. Whereas mean signal internsity decreased slowly in fusiform area, it rapidly dropped and resumed in transition area to outlet. In computer assisted flow simulation, Whereas there were flow velocity decrease and flow direction change to peripheral in entrance to fusiform area, ther were rapid flow velocity resuming and flow direction change to central in transition area to outlet. Conclusion : The signal loss and target appearance in transition area to outlet is characteristic of fusiform flow. These signal changes correlate with abrupt flow velocity and direction change well.

  • PDF

Three-Dimensional Brain Surface Rendering Imaging of Cortical Dysplasia (뇌피질 이형성증의 3차원 뇌표면 연출영상)

  • Hwang, Seung-Bae;Kwak, Hyo-Sung;Lee, Sang-Yong;Jin, Gong-Yong;Han, Young-Min;Chung, Gyung-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.126-133
    • /
    • 2010
  • Purpose : The study was to evaluate the localization of the abnormal gyral and sulcal patterns obtained by means of brain surface rendering imaging. Materials and Methods : Nineteen patients with cortical dysplasia who underwent brain surface rendering MR imaging were included in this study. We acquired MP-RAGE sequence and created the 3-D surface rendering MR images by using $VoxelPlus^{(R)}$. Anatomical locations and configurations of abnormal gyri and sulci were reviewed. Results : Abnormal gyral and sulcal patterns were seen 18 in 19 patients. The configuration and orientation of affected gyri and sulci were clearly evaluated in the brain surface rendering images. In a lissencephaly, the a cortex was not delineated and showed markedly thick and smooth gyral pattern. In a schizencephaly, there were wheel shaped broad gyral pattern around the cleft. In a hemimegalencephaly, an affected hemisphere were enlarged and displayed thick and wide gyral pattern. In CBPS, the insular cortex was exposed and the gyri of the lesion were thickened. In focal cortical dysplasia, there were irregular serrated or thick and enlarged gyri. Conclusion : Brain surface rendering MR imaging is useful for the evaluation of a detailed gyral pattern and accurate involvement site of abnormal gyri.