• Title/Summary/Keyword: 2D Marker

Search Result 513, Processing Time 0.025 seconds

Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker (영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구)

  • Kim, Jong-Min;Kim, Dae-Sup;Back, Geum-Mun;Kang, Tae-Yeong;Hong, Dong-Ki;Yun, Hwa-Yong;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Purpose: The effect of artifact was analyzed, which occurs from fiducial marker during the liver Image Guided Radiation Therapy (IGRT) using the fiducial marker. Materials and Methods: The size of artifact of fixed fiducial marker and length of mobile fiducial marker locus were measured using the On-Board Imager system (OBI) and CT simulator, and 2D-2D matching and 3D-3D matching were carried out, respectively, and at this time, the coordinates transition value of couch was analyzed. Results: The measurement of fixed fiducial marker artifact size indicated CT 4.90, 8.10, 12.90, 19.70 mm and OBI 5.60, 10.60, 14.70, 29.40 mm based on the reference CT slice thickness of 1.25, 2.50, 5.00, and 10.00 mm. Meanwhile, the measurement of mobile fiducial marker locus length indicated CT 42.00, 43.10, 46.50 mm, and OBI 43.40, 46.00, 49.30 mm. The coordinates transition of 1.00, 2.00, and 8.00 mm occurred between 2D-2D matching and 3D-3D matching. Conclusion: It was confirmed that the therapy error increased during IGRT due to the influence of artifact when CT slice thickness increased. Thus, it may be desirable to acquire the image less than 2.50 mm in slice thickness when IGRT is implemented using the fiducial marker.

  • PDF

Usability of 2D/2D Match for Image Guided Radiotherapy (IGRT) of Prostate Cancer with Fiducial Markers (전립선 암 환자의 영상유도 방사선 치료 시 Fiducial Marker를 이용한 2D/2D Match의 유용성에 대한 연구)

  • Bae, Sun-Myung;Yang, Oh-Nam;Song, Heung-Kwon;Back, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Purpose: To study the efficacy of marker match with using kilovoltage (KV) X-ray among multiple image guidance that referring tree fiducial marker in radiation therapy for prostate cancer patients. Materials and Methods: KV two-dimantional images (anterior-posterior, right-left) and cone-beam CT volumetric images were acquired after setup for patients with three fiducial markers. Compare the position of the fiducial marker of reference plan computed tomography (CT) and of KV, CBCT images; then decide the shift score of X, Y, and Z. This study executed 5 times on 10 patients and analyzed the shift value. Results: In the radiation therapy using fiducial marker, The function of marker match showed the same direction tendency as the CBCT, and showed X, Y, Z difference of about 0.6, 0.7, and 0.8 (unit: mm). Conclusion: Comparing to this, the result of shift value using 2D marker match showed less than 1.0 mm difference. The function of marker match is considered more useful in time-wise and effective dose rather than CBCT. Therefore, Both methods are used to treat patients for prostate cancer.

  • PDF

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Adaptive planar vision marker composed of LED arrays for sensing under low visibility

  • Kim, Kyukwang;Hyun, Jieum;Myung, Hyun
    • Advances in robotics research
    • /
    • v.2 no.2
    • /
    • pp.141-149
    • /
    • 2018
  • In image processing and robotic applications, two-dimensional (2D) black and white patterned planar markers are widely used. However, these markers are not detectable in low visibility environment and they are not changeable. This research proposes an active and adaptive marker node, which displays 2D marker patterns using light emitting diode (LED) arrays for easier recognition in the foggy or turbid underwater environments. Because each node is made to blink at a different frequency, active LED marker nodes were distinguishable from each other from a long distance without increasing the size of the marker. We expect that the proposed system can be used in various harsh conditions where the conventional marker systems are not applicable because of low visibility issues. The proposed system is still compatible with the conventional marker as the displayed patterns are identical.

The study for improve a method of Marker auto- identification (마커 자동 인식 향상 방법에 관한 연구)

  • Lee, Hyun-Seob
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.23-38
    • /
    • 2003
  • The purpose of this study is to develop an improved marker auto-identification algorithm for reduce of data processing time through improve the efficiency of noise elimination and marker separation. The maker auto-identification algorithm was programming named KUMAS used Delphi language. For the study, various experiments were conducted for the verification of KUMAS. and compared two systems of established with the KUMAS. Four different motions - cycling, gait, rotation, and pendulum -, were selected and tested. Motions were filmed 30Hz frames rate per second. ${\chi}^2$ used for statistical analysis. Significant level were ${\alpha}=.05$. The test results were as follow. 1. Increased the success ratio of marker auto-identification. 2. The efficiency of marker auto-identification was remarkably improved through marker separation, noise elimination. 3. The marker auto-identification ability was improved in 2D-image plane include the 3D motion. 4. Significant different were found between KUMAS and B-SYS(established system) with non-input the artificial noise frames, input the artificial noise frames and total frames.

The Study of Stable Child English Education Content Using Augmented Reality Solving the Hide of Marker (마커의 가려짐을 해결하여 증강현실을 이용한 안정적 영어 학습 컨텐츠에 대한 연구)

  • Jeon, Soo-Jin;Kim, Young-Seop
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.4
    • /
    • pp.99-102
    • /
    • 2010
  • In this study, the 3- dimensional (3-D) learning contents are suggested using 'Augmented Reality' instead of existing 2-dimensional (2-D) learning methods. At the present, there are some 2-D learning methods using texts, image, pictures, and videos called e-learning. However, these one-way 2-D methods have some disadvantages such as declining learner's immersion and concentration. Thus, the 3-D learning contents using 'Augmented Reality' are suggested to compensate the disadvantages. According to the development of information technology (IT), the augmented reality has many applications to the era of ubiquitous. However, there are some disadvantages when learners use these contents as following; non-augmenting by partially hiding from makers and declining concentration by patterns of the makers. In this study, the beneficial marker which can solve this non-augmenting phenomenon is suggested.

Development of a CMS-specific marker based on chloroplast-derived mitochondrial sequence in pepper

  • Jo, Yeong Deuk;Jeong, Hee-Jin;Kang, Byoung-Cheorl
    • Plant Biotechnology Reports
    • /
    • v.3 no.4
    • /
    • pp.309-315
    • /
    • 2009
  • Molecular markers developed from the flanking sequences of two cytoplasmic male sterility (CMS)-associated genes, orf456 and ${\Psi}atp6-2$, have been used for marker-assisted selection of CMS in pepper. However, in practice, the presence of orf456 and ${\Psi}atp6-2$ at substoichiometric levels even in maintainer lines hampers reliable selection of plants containing the CMS gene. In this study, we developed a novel CMS-specific molecular marker, accD-U, for reliable determination of CMS lines in pepper, and used the newly and previously developed markers to determine the cytoplasm types of pepper breeding lines and germplasms. This marker was developed from a deletion in a chloroplast-derived sequence in the mitochondrial genome of a CMS pepper line. CMS pepper lines could be unambiguously determined by presence or absence of the accD-U marker band. Application of orf456, ${\Psi}atp6-2$and accD-U to various pepper breeding lines and germplasms revealed that accD-U is the most reliable CMS selection marker. A wide distribution of orf456, but not ${\Psi}atp6-2$, in germplasms suggests that the pepper cytoplasm containing both orf456 and ${\Psi}atp6-2$ has been selected as CMS cytoplasm from cytoplasm containing only orf456. Furthermore, factors other than orf456 may be required for the regulation of male sterility in pepper.

Utility of the pat gene as a selectable marker gene in production of transgenic Dunaliella salina

  • Jung, Hyo Sun;Kim, Dong Soo
    • Fisheries and Aquatic Sciences
    • /
    • v.19 no.7
    • /
    • pp.31.1-31.6
    • /
    • 2016
  • Background: The objective of this study was to develop an efficient selectable marker for transgenic Dunaliella salina. Results: Tests of the sensitivity of D. salina to the antibiotic chloramphenicol and the herbicide Basta$^{(R)}$ showed that cells ($1.0{\times}10^6cells/ml$) treated with 1000 or $1500{\mu}g/ml$ chloramphenicol died in 8 or 6 days, respectively, whereas D. salina cells ($1.0{\times}10^6cells/ml$) treated with 5, 10, 20, or $40{\mu}g/ml$ Basta$^{(R)}$ died in 2 days. Therefore, D. salina is more sensitive to Basta$^{(R)}$ than to chloramphenicol. To examine the possibility of using the phosphinothricin N-acetyltransferase (pat) gene as a selectable marker gene, we introduced the pat genes into D. salina with particle bombardment system under the condition of helium pressure of 900 psi from a distance of 3 cm. PCR analysis confirmed that the gene was stably inserted into the cells and that the cells survived in $5{\mu}g/ml$ Basta$^{(R)}$, the medium used to select the transformed cells. Conclusions: The findings of this study suggest that the pat gene can be used as an efficient selectable marker when producing transgenic D. salina.

Effect of RFLP Marker of the Mitochondrial DNA D-Loop Region on Milk Production in Korean Cattle (한우 Mitochondrial DNA D-Loop 영역의 RFLP Marker가 산유량에 미치는 영향)

  • Chung Eui-Ryong;Chung Ku-Young
    • Food Science of Animal Resources
    • /
    • v.25 no.2
    • /
    • pp.218-225
    • /
    • 2005
  • This study was performed to determine sequence variation and RFLP of the mt DNA D-loop region using Southern blot hybridization analysis and to develop mt DNA marker affecting milk production traits in Hanwoo cows. The PCR was used to amplify an 1142 bp fragment within the D-loop region of mt DNA using specific primers. Mt DNA were digested with seven restriction enzymes and hybridized using DIG-labeled D-loop probe. The mt DNA RFLP polymorphisms were observed in the four enzymes, BamHI, RsaI, XbaI and HpaII. Nucleotide substitutions were detected at positions 441 (G/C), 469 (T/C), 503 (C/T), 569 (G/A), 614 (C/A) and 644 (C/T) of the mt DNA D-loop region between two selected lines. Significant relationship between the XbaI RFLP type and breeding value was found(p<0.05). Cows with A type had higher estimated breeding values than those with B type (P<0.05) between high and low milk production lines. Therefore, the RFLP marker of mt DNA could be used as a selection assisted tool for individuals with high milk producing ability in Hanwoo.

Expression of Microsatellite Instability (MSI) from Colorectal Carcinoma Patients

  • Lee, Jae Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.46 no.2
    • /
    • pp.59-63
    • /
    • 2014
  • The death toll of Colorectal Carcinoma in Korea was 1,826 and 7,721 in the years 1992 and 2011, respectively. This rate of increase was shown to be more than 4.23 times higher than that of any other form of cancer. Therefore, Colorectal Carcinoma requires various diagnostic methods, and Microsatellite Instability (MSI) was applied as a new diagnostic tool. From this study with several microsatellite markers, only marker #13 was detected and observed D13S160 13% (4/30), D13S292 13% (4/30), D13S153 10% (3/30) in order. From the results of amplication with microsatellite marker, D13S292 37% (11/30), D13S153 33% (10/30), D13S160 33% (10/30) in order were shown. The appearance of a genetic mutation, which depends on the loci of Colorectal Carcinoma, was shown amplication from rectal cancer (3.77) which was higher than that of right Colorectal Carcinoma (2.08) (p<0.018). The genetic mutation with lymph node (4.13) appeared higher than normal (1.93) (p<0.001). There were no great differences in the genetic mutation dependent on disease, histological classification and increased group of serum CEA. Accordingly, it is suggested that the correct primers, which can evaluate MSI well from colorectal carcinoma, should be chosen and that MSI be considered a good prognosis and quality control tool.