• Title/Summary/Keyword: 2D 스캐너

Search Result 166, Processing Time 0.029 seconds

A New Quantification Method of Rock Joint Roughness (I) - A Close Assessment of Problems (암석 절리면 거칠기의 정량화에 대한 연구 (I) - 문제점의 규명)

  • Hong, Eun-Soo;Nam, Seok-Woo;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.4
    • /
    • pp.269-283
    • /
    • 2005
  • To figure out the cause of underestimating the roughness and shear strength of rock joints suggested by numerous researchers, we analyzed roughness mobilization characteristics, characteristics of roughness parameters, effects of sampling interval, and waviness for roughness parameters. It was found out that lack of understanding of the roughness mobilization characteristics, inappropriate applications of roughness parameters, and effect of aliasing provide a main reasons for those problems. Several practical alternatives for improving those problems were suggested. As far as digitizing methods are concerned, we can find that using a 3D scanner can give a relatively effective result. To avoid aliasing, sampling interval should be less than one-quarter of the minimum asperities. As for the quantification of roughness, it was analyzed that the roughness parameter should be classified into two components depending on the scale of roughness to apply the shear strength model. For classifying the roughness, a framework of the criterion was suggested based on the plastic flow concept for the asperity failure, and the basis for proposing a new alternative shear strength model was established.

  • PDF

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.

Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of pitch measuring uncertainty of a nano-accuracy AFM system (XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 나노 정밀도의 원자 현미경 피치 측정 불확도 평가)

  • Kim Dong-Min;Lee Dong-Yeon;Gweon Dae-Gab
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.96-103
    • /
    • 2006
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In the long range (about several tens of ${\mu}m$), measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100{\mu}m\times100{\mu}m$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. As a result, XY scanner can have good performance. Using this AFM system, 3um pitch specimen was measured. The uncertainty of total system has been evaluated. X and Y direction performance is different. X-direction measuring performance is better. So to evaluate only ID pitch length, X-direction scanning is preferable. Its expanded uncertainty(k=2) is $\sqrt{(3.96)^2+(4.10\times10^{-5}{\times}p)^2}$ measured length in nm.

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF

Stability Test of Stone Mattress Method by Real-scale Hydraulic Experiment (스톤매트리스 공법의 실규모 수리 안정성 실험)

  • Kim, Sung Jung;Kim, Myoung Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.223-223
    • /
    • 2021
  • 호안은 유수로부터 제방과 하안을 보호하는 구조물로 태풍 또는 집중호우로 인한 홍수로부터의 안정성이 확보되어야 한다. 적정한 호안공법 또는 제품의 선정을 위해서는 유속, 소류력 등이 반영된 수리 안정성 검토가 필요하나 현재 국내에는 이와 관련한 객관적인 평가나 시험 기준이 제시되어있지 않기 때문에 국내에서는 실제 수리실험을 통한 호안제품 및 공법의 수리학적 안정성을 제공하는 경우는 찾아보기 어려운 것이 현실이다. 본 연구는 호안공법 중 친환경적 재료를 사용하여 개발된 스톤매트리스 호안공법의 수리적 안정성을 검토하기 위해 수행되었다. 스톤매트리스 공법은 상부망과 하부망의 체결을 통해 돌을 군체로 일체화 시킴으로써 치수 안정성이 매우 뛰어나며, 충분한 식생공간을 확보한 공법으로 재료의 2차 변형 방지가 가능하며 안전한 군체 유지가 가능한 공법이다. 이러한 공법에 대한 안정성 검토를 위한 실규모 실험은 안동 하천연구센터에서 수행하였다. 실험에 사용된 수로는 8°의 경사를 갖는 급경사수로에서 수행되었다. 수로의 제원은 폭 3m, 길이 30m 의 직사각형 형태의 직선수로로 이루어져 있다. 시험체는 실규모로 제작되며 2m × 10m 의 제원을 갖는 별도의 트레이에 시공되어 실험시 크레인을 이용하여 실험수로에 안착시킨다. 수리 안정성 실험은 실험대상유량을 단계별로 나누어 점차적으로 증가시키며, 시험체의 이탈, 파괴 등의 큰 변화가 발생하였을 경우 실험을 종료한다. 수리량 측정은 유속측정, 수위관측 등으로 이루어지며, 재료의 변형은 3D스캐너를 이용하여 변위를 검토하였다. 총 3회에 걸친 실험결과 실험수로에서 발생가능한 최대유량인 4.34cms 조건에서 실험체 바닥에서의 소류력은 약 300N/m2 의 소류력이 발생하는 것으로 확인되었다. 또한 재료의 수직변위는 최대 1.8mm로 계측기 오차범위에 근접한 수치를 보이는 것으로 실험체의 이동이나 석재의 파손은 발생하지 않은 것으로 나타났다.

  • PDF

A Study on Landscape Management Techniques of Cultural Heritage Designated Area Using 3D Mapping Method (3D맵핑을 이용한 문화재 지정구역 경관관리기법 연구)

  • Kim, Jae-Ung;Lee, Won-Ho;Shin, Hyun-Sil
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.1
    • /
    • pp.97-108
    • /
    • 2018
  • The purpose of this study is to propose the construction of a visibility analysis model, which is the basis of the analysis for landscape management on the heritage sites such as historic villages and scenic sites. Results of the visibility analysis using DEM and the visibility analysis of DSM based on 3D mapping data are compared as follows: Precision level of the extracted data was confirmed to be less than 6.5cm, based on RTK survey results produced by constructing orthoimage data and DSM from the digital data of 2cm-class GSD(Ground Sample Distance) obtained by using a small UAV(Unmanned Aerial Vehicle). As a result of comparing the visibility analysis data of Digital Surface Model (DSM) using a small UAV with Digital Elevation Model(DEM) applying the height of the building to the Digital Topographic Map, it was confirmed that more realistic visibility analysis can be accomplished by applying DSM, as the structures such as fences, trees, and houses are reflected in the topographic data. The visibility analysis model using the 3D mapping technique can efficiently obtain the constantly changing topographic information when needed, by immediately constructing the data by utilizing a small UAV. It seems to be possible to propose a reasonable analysis result for preservation management such as landscape evaluation of cultural property.

A Study on the Restoration of Chimi Excavated the Wangheungsa Temple Site using 3D Scanning and Computer Numerical Control (3차원 스캐닝과 컴퓨터 수치 제어 기술을 이용한 왕흥사지 출토 치미의 복원 연구)

  • Park, Min Jung;Hwang, Hyun Sung;Hong, Shin Yeon
    • Journal of Conservation Science
    • /
    • v.35 no.3
    • /
    • pp.217-225
    • /
    • 2019
  • The chimi(ridge-end tile) of Wangheungsa temple is the oldest in our country. The upper part of the chimi was excavated from the southern side of Wangheungsa temple and the lower part from the northern side. These parts are considered to be portions of the same chimi, because they are similar in shape and are excavated from two sides of the same temple structure. However, the original shape of the chimi cannot be determined owing to substantial deterioration. Hence, in this study, replicas of the deteriorated chimi portions of Wangheungsa temple were fabricated by employing 3D scanning technology and the computer numerical control machining method. While observing the bending phenomenon of the chimi, the proposed model was warped realistically on the basis of the bending direction of the actual chimi. Consequently, the restoration process was modified several times. The results indicated that no gaps can be found between the upper and lower parts, and the corresponding patterns connect naturally. Furthermore, the proposed method is contactless, safe, operable, reproducible, and appropriate for restoration of artifacts. Additionally, the modeling data is semi-permanent. Hence, if modelling data is appropriately applied as per the characteristics of artifacts, it can be utilized in various fields such as virtual exhibitions, hands-on exhibitions, cultural heritage restoration, and production of teaching aids and souvenirs.

Development of Parallel Signal Processing Algorithm for FMCW LiDAR based on FPGA (FPGA 고속병렬처리 구조의 FMCW LiDAR 신호처리 알고리즘 개발)

  • Jong-Heon Lee;Ji-Eun Choi;Jong-Pil La
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.2
    • /
    • pp.335-343
    • /
    • 2024
  • Real-time target signal processing techniques for FMCW LiDAR are described in this paper. FMCW LiDAR is gaining attention as the next-generation LiDAR for self-driving cars because of its detection robustness even in adverse environmental conditions such as rain, snow and fog etc. in addition to its long range measurement capability. The hardware architecture which is required for high-speed data acquisition, data transfer, and parallel signal processing for frequency-domain signal processing is described in this article. Fourier transformation of the acquired time-domain signal is implemented on FPGA in real time. The paper also details the C-FAR algorithm for ensuring robust target detection from the transformed target spectrum. This paper elaborates on enhancing frequency measurement resolution from the target spectrum and converting them into range and velocity data. The 3D image was generated and displayed using the 2D scanner position and target distance data. Real-time target signal processing and high-resolution image acquisition capability of FMCW LiDAR by using the proposed parallel signal processing algorithms based on FPGA architecture are verified in this paper.

Effect of mixing method and storage time on dimensional stability of alginate impressions materials (혼합 방법과 보관 시간이 알지네이트 인상재의 체적 안정성에 미치는 효과)

  • Bang, Hyun-Ji;Shim, Hyun-Ah;Cho, Young-Eun;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.86-94
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the volume stability depending on the mixing methods and storage time for the conventional alginate and extended-pour alginate. Materials and methods: An arch-shaped metal model was fabricated, and one conventional alginate and two extended-pour alginates were used to take impressions using different mixing methods (hand and automatic). 120 impressions were taken (40 per each alginate) and stone models were made in accordance with the different storage times (immediate, 2 days, 5 days, and 6 days). The models were scanned with a 3D table scanner and dimensional change was measured by superimposing the scan data. Using SAS 9.4 (SAS Institute Inc., Cary, NC, USA), the general linear model and Tukey's post hoc test was conducted for statistical analysis (P<.001). Results: There was no statistically significant difference in the dimensional accuracy between two mixing methods, and the volume change was minimum when the stone was poured immediately in all groups. Dimensional accuracy showed a statistically significant difference between groups after 2 days of storage, and extended-pour alginate showed higher accuracy after 5 days of storage comparing to conventional one. Large amounts of volume change were showed at 2 - 5 days for conventional alginate and at 5 - 6 days for extended pour alginate. Conclusion: The mixing method of alginate does not affect volume stability. Although extended-pour alginate has better volume stability than conventional alginate for a long time, it is recommended to pour stone as soon as possible.

Characteristics Analysis of Burned tree by Terrestrial LiDAR in Forest Fired Area of Pinus densiflora (지상라이다를 활용한 소나무 산불피해지의 임목 피해특성 분석)

  • Kang, Jin-Taek;Ko, Chi-Ung;Yim, Jong-Su;Lee, Sun-Jeoung;Moon, Ga-Hyun;Lee, Seung-Hyun
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_1
    • /
    • pp.1291-1302
    • /
    • 2020
  • To verify the field-effectiveness of Terrestrial Laser Scanner (TLS), a terrestrial LiDAR was deployed to examine the damage properties of woods in forest fire area, then the data was compared with the results surveyed by a forestry expert. Four sample plots (30 m × 50 m, 0.15 ha) were set from the foot to the top of the mountain, and DBH, height, clear length, burned height, and crown length were investigated. Next, TLS collected information on damage characteristics found in the sample plots. This information was then compared with that amassed by the expert. The expert and the TLS survey results showed 30.8 cm and 29.9 cm for DBH, 15.8 m and 17.5 m for tree height, 8.4 m and 8.4 m for clear length, 4.0 m, 3.5 m for burned height, and 7.4 cm and 9.1 cm for crown length. With the exceptions of height and clear length, no notable discrepancy was observed between two methods. H/D ratio, CL/H ratio, and BH/CL ratio, all of which contribute to stability and decay rate of the stand, from the two methods were also compared. The human survey rated each ratio (H/D, CL/H, BH/CL in order) 51.3%, 47.1%, and 53.6%, while the TLS presented the results of 58.8%, 52.0%, and 38.7%.